Valve Closure Systems for 1-Ton Containers or 150-Pound Cylinders

Similar documents
Valve Closure Systems for Plug-Type Angle Valves or Ball-Type Angle Valves

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

CAPITAL CONTROLS SERIES NXT3000

ChlorTainer is the safest, most reliable technology available for processing and preventing a chlorine gas release.

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

ACV-10 Automatic Control Valve

Goulds 3296 EZMAG. Chemical Process Pump

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Complying with NFPA 58 Transfer Area and Bulk Plant Liquid Opening Requirements

Float Operated Level Controllers

Petro-Chemical & Analyzer Sampling Systems

Petro-Chemical & Analyzer Sampling Systems

TRANSFER SYSTEM DESCRIPTION...3

Highest Quality. Gas Chlorination Systems

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Simplicity in VRU by using a Beam Gas Compressor

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Model 4000 Pressure Controller

Manual Actuated Boiler Blowdown Valves

Alkylphosphines. Storage and Handling Recommendations

CONTROL VALVE TESTING

Model VR6 System. Installation, Operation & Maintenance

Chemical Injection Technologies Installation/Service Bulletin

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

MEDICAL EQUIPMENT CATALOG

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

Choosing the right miniature instrument and control valve is a snap

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SANITIZERS SANITIZERS SANITIZERS FOR POOLS & SPAS

AutoDrill s OUTSTANDING FEATURES

Autocalibration Systems For In Situ Oxygen Analyzers

Life Sciences. Pressure control solutions for your industry.

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Inert Air (N2) Systems Manual

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

Manifolds & pressure reducing sets

Valve Proving System VDK 200 A S06*

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Valve Proving System VDK 200 A S02

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Autocalibration Systems for In Situ Oxygen Analyzers

64 Series Pressure Reducing Regulators

Model: AT-1000 L.P.G. FREEZE VALVE

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

Air Amplifiers & SYSTEMS

MUD 1. Vent check valves. Instruction and maintenance manual.

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

Safe Handling. of Chlor Alkali Products

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

INSTALLATION INSTRUCTIONS FOR FUME SCRUBBERS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

BERMAD Fire Protection Hydraulic Control Valves

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

Series 2G Diaphragm Actuators

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

Unit 24: Applications of Pneumatics and Hydraulics

MEGR-1912 Instruction Manual

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

V43 Pressure Actuated Water Regulating Valve

Chlorinator MODEL MK-I

INSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW

Hip Air Operated Valves

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

Automatic Valve Proving Control

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

Liquid Level Controllers

RAM 4021 Operation Manual

ANDERSON GREENWOOD TANK BLANKETING REGULATORS

Pressure Regulator B-95

Model: AT-1000 L.P.G. FREEZE VALVE

HORIZONTAL BLADDER TANK

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves.

Rosemount 3159 Nuclear Qualified Remote Diaphragm Seal

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified


Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

LPG DRIVER ATTENDED TRANSPORT LOADING

TECHNICAL DATA. than the water inlet pressure to the concentrate

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

Transcription:

Powell Valve Closure Systems for 1-Ton Containers or 150-Pound Cylinders MaxPro TM RA Pneumatic Valve Closure System E-Pro Electric Valve Closure System

The Information contained herein is, to our best knowledge, true and accurate, but all recommendations or suggestions are made without guarantee, since the conditions of use are beyond our control. Powell Fabrication & Manufacturing, Inc. disclaims any liability incurred in connection with the use of this information. Furthermore, nothing contained herein shall be construed as a recommendation to use any product in conflict with existing patents covering any material or its use. Table of Contents Powell Valve Closure System...2-3 MaxPro RA Valve Closure System...4-5 MaxPro RA Major Components...6-7 E-Pro Electric Valve Closure System...8-9 E-Pro Electric Major Components...10-11 Complimentary Equipment...12-13 Powell Product Line...14 2

Powell Valve Closure Systems for 1-Ton Containers and 150-Pound Cylinders Valve Closure Systems from Powell represent today s best available technology to prevent catastrophic releases of hazardous gases from containers. Powell Valve Closure Systems, designed to shut off at the container valve within seconds of detection, are available in pneumatic or electric versions. Either system can be configured to automatically close the valve in the event of a leak, security breach, fire alarm, seismic event or other circumstance. Alternatively, the systems can be activated manually from the main control panel or from remote-mounted emergency stop panels located inside or outside the room. Powell Valve Closure Systems for 1-ton containers and 150-pound cylinders, available in both pneumatic and electric versions, accommodate the complete range of application requirements. Each system offers unique benefits and numerous advantages to the user. MaxPro RA Pneumatic Valve Closure System The MaxPro RA Pneumatic Valve Closure System requires nitrogen or dry air (-40 F or C dewpoint at 100 psig) to operate. In some facilities, this mode of power is more readily available than electric power. If a pneumatic system best meets your application conditions, you ll want to consider the Powell MaxPro RA Pneumatic Valve Closure System. E-Pro Electric Valve Closure System The E-Pro Electric Valve Closure System is perfect for plants that do not have compressed air or nitrogen available. It operates on standard 120 VAC power. If an electric system best meets your application conditions, you ll want to consider the Powell E-Pro Electric Valve Closure System. Figure 1: Six Reasons to Install a Powell Valve Closure System Fewer Reportable Releases Protection for Community Safer Conditions for Site Workers Alternative to Emergency Scrubber System A Powell Valve Closure System stops a leak long before the RQ (Reportable Quantity) established by the EPA is released. A Powell Valve Closure System protects the surrounding community from the dangers of a hazardous chemical leak. A Powell Valve Closure System activates automatically, or manually from a remote location, eliminating the need for workers to enter a hazardous environment to shut off a gas leak. A Powell Valve Closure System can be an alternative to a more costly emergency scrubber system. More Protection at Lower Cost Improve RMP Scenarios A Powell Valve Closure System can be used in combination with a Powell Sentry Emergency Scrubber System to provide complete facility protection at a lower cost. Many times, the integration of a valve closure system means the scrubber can be downsized. Risk Management Planning (RMP), mandated several years ago, requires that facilities with on-site above specified amounts submit scenarios detailing the anticipated impact of a hazardous gas release. A Powell Valve Closure System can significantly reduce the consequences in these scenarios. Designed and Built by Industry Leader Powell Valve Closure Systems are designed and built by Powell, leaders in the chlor-alkali industry since 1964. Powell equipment and technology are used extensively in the US and throughout the world in both municipal and industrial applications. The MaxPro RA Pneumatic Valve Closure System and the E-Pro Electric Valve Closure System draw on a longstanding and thorough understanding of chlorine, one of the most corrosive elements to metals and electronics. Powell has built chlorine scrubbers since 1975 and is the leading supplier of sodium hypochlorite processing equipment, roughly 80% of the sodium hypochlorite produced in North America is made on Powell equipment. Powell s extensive understanding of chlorine and related chemicals and compounds have enabled it to develop equipment to safely and cost effectively produce, mix, contain, and transport a wide variety of extremely hazardous chemicals. 3 Powell

MaxPro RA Pneumatic Valve Closure System for 1-Ton Containers and 150-Pound Cylinders Pneumatic technology is often preferred for its uncomplicated concepts, basic components, and low maintenance requirements, adding up to a reliable, trouble-free system. Simply because it is a basic technology, pneumatics offers several advantages in a critical valve closure application. For example, in addition to attractive economics, the pneumatic motor is capable of hundreds of thousands of cycles, and operating pressure (force or torque) can be increased. Pneumatic drives can also easily handle the breakway torque that may be required if the system is activated at irregular intervals or left stationary for extended periods of time. These benefits and functionality, inherent in a pneumatic system, are taken full advantage of in the Powell MaxPro RA Pneumatic Valve Closure System*. To enhance functionality and reliability even further, the complete MaxPro RA Pneumatic System incorporates several components to support the pneumatic drive. Each system component is engineered, designed, tested, and built by Powell to ensure proper performance and reduced installation time, labor, and material cost. * US Patent #6,840,503 4

The MaxPro RA Pneumatic Valve Closure System is designed in accordance with guidelines established by The Chlorine Institute, Inc. for valve closure systems. The MaxPro RA Pneumatic Actuator has an easy-mount bracket that attaches to the cylinder valve just below the packing nut. The unit can be quickly and easily attached and detached from the cylinder by a single operator. No tools are required for assembly or disassembly. When the MaxPro RA Pneumatic Actuator is installed, the right angle design of the gearbox allows manual operation of the valve with a standard wrench. The MaxPro RA Pneumatic Actuator can accommodate the installation of many common vacuum regulators. The MaxPro RA Pneumatic System is designed to function with 90 psig air or nitrogen pressure. The MaxPro RA Pneumatic Valve Closure System can be used with vacuum or pressurized systems and can use air or nitrogen as the operating gas. 5 Powell

MaxPro TM RA Pneumatic System Major Components MaxPro RA Pneumatic Actuator The MaxPro RA Pneumatic Actuator is the basis of the system. The unit, which weighs just 5.5 pounds, includes a pneumatic drive with a spring-loaded coupler designed to accommodate cylinder valve stems of varying lengths. The actuator is held in place on the container valve stem with a mounting bracket that attaches directly to the valve stem. The mounting bracket does not rely on the packing nut, yoke assembly, or other external component for support. When the pneumatic actuator is in place, the right angle design of the gearbox allows manual operation of the valve with a standard wrench. The MaxPro RA Pneumatic Actuator is easily attached and detached with a hitchpin and can be installed and removed by one person without the use of tools. Control Panel A basic control panel automatically activates the MaxPro RA Pneumatic System in the event of a gas leak, security breach, fire alarm, seismic event or other pre-determined circumstance. A single control panel can activate up to 8 containermounted MaxPro RA Pneumatic Actuators to simultaneously close all 8 valves within 3 seconds. The system can also be activated manually from the control panel. UL listed (Underwriters Laboratory) panels are available and Powell can also supply custom panels. The 6-foot air supply hose included with the unit connects the pneumatic actuator to the operating gas supply. The hose connects easily to the pneumatic actuator with an Oetiker swing coupling. The swivel fitting ensures a secure connection between actuator and gas supply and helps to prevent kinks or tangles in the hose. 6

MaxPro TM RA Pneumatic System Major Components Remote Emergency Stop Pushbutton Panel Operators can use the Remote Emergency Stop Pushbutton Panel (E- Stop Panel) to manually activate the system from a safe remote location. The E-Stop Panel can be installed wherever appropriate for operators to reach in an emergency. These allow an operator to activate the MaxPro RA Pneumatic Valve Closure System from a safe location. Air Control Unit The MaxPro RA Air Control Unit is a group of components designed to work together to supply the proper amount of clean pressurized air to the system. This equipment is pre assembled for simple installation. Air Receiver The MaxPro RA Air Receiver stores compressed air to enable the system to function even if power or air pressure is lost. Uninterruptible Power Supply The uninterruptible power supply prevents the MaxPro RA Pneumatic Valve Closure System from activating when AC supply voltage is lost or fluctuates. In the event of a sustained power loss, the valve closure system will activate to close container valves after approximately 30 minutes. The system can also be configured to activate the system as soon as plant power is lost. 7 Powell

E-Pro Electric Valve Closure System for 1-Ton Containers and 150-Pound Cylinders An electric valve closure system is often the choice in an application where air supply lines and components are simply not available. In addition to air availability and quality, an electric system offers convenience, simplified installation, and ability to integrate effortlessly into existing computer controlled processes. As a result of this practicality and ease of use, an electrical valve closure system is often the emergency shut-off system of choice for smaller plants or those who don t have compressed air or nitrogen available. The Powell E-Pro Electric Valve Closure System* is an ideal selection when an electric system is preferred. It s designed to automatically close the valves on 1- ton containers and 150-pound cylinders in the event of gas leak, seismic activity and process shutoffs, as well as virtually any other condition that may be required or desired. * Patent Pending, Powell 8

The E-Pro Electric Valve Closure System uses standard 120- volt AC power and requires no other tools or fixtures to operate. The electric actuator is designed to deliver 40 lb-ft of torque to a standard valve stem, in both opening and closing directions. When installed on a ton container, the E-Pro Electric Actuator protrudes less than 9 inches beyond the valve stem. This helps keep the unit away from passing equipment and personnel. The E-Pro Electric Actuator can accommodate the installation of a vacuum regulator. Any non-leaking valve that has been closed by the E-Pro Electric Actuator can be reopened using the Open button on the end of the actuator. The E-Pro System will respond to any alarm input and close the container valves in less than 5 seconds. The E-Pro Electric Valve Closure System is designed in accordance with guidelines established by The Chlorine Institute, Inc. for valve closure systems. 9 Powell

E-Pro Electric System Major Components E-Pro Electric Actuator The E-Pro Electric Actuator is the key component of the electric system. The unit weighs 8.5 pounds and mounts on the container valve as the yoke/vacuum regulator is attached. A single operator can easily attach and detach the unique two-piece mounting bracket onto or off the valve stem in seconds, without the use of tools. The E-Pro Electric Actuator is reversible and the Open button on the end of the electric actuator can be used to re-open any non-leaking valve the unit has closed. The E-Pro Electric Actuator is solidly made from quality materials of construction and components, some of which were developed specifically for this unit. The actuator housing is sealed to prevent intrusion of wind or water in outdoor applications. Control Panel 13 The E-Pro Control Panel automatically activates the E-Pro Electric Valve Closure System in the event of a gas leak, seismic activity, process shutoff or other monitored condition. When activated, the control panel automatically shuts off the power to the actuator when the valve has been closed to the appropriate torque. An operator can manually activate the system by depressing the emergency stop pushbutton on the panel. Remote emergency stops are also connected to the control panel, allowing for remote, manual system activation. Valve Adapter 10

E-Pro Electric System Major Components Remote Emergency Stop Pushbutton Panel Operators can use the Remote Emergency Stop Pushbutton Panel (E- Stop Panel) to manually activate the system from a safe remote location. The E-Stop Panel can be installed wherever appropriate for operators to reach in an emergency. These allow an operator to activate the E-Pro Electric Valve Closure System from a safe location. Uninterruptible Power Supply The uninterruptible power supply prevents the -Pro Electric Valve Closure System from activating when AC supply voltage is lost or fluctuates. In the event of a sustained power loss, the valve closure system will activate to close container valves after approximately 30 minutes. The system can also be configured to activate the system as soon as plant power is lost. The E-Pro Electric Actuator mounts on the body of the valve, not the yoke. In yoke mounted designs, the full torque applied by the actuator to the valve stem is transferred through the yoke, trying to turn the yoke on the body of the valve. This could result in failure of the lead gasket between the yoke and the container valve, leading to a leak. Once installed and leak checked, the E-Pro Electric Actuator can be used to routinely open and close the valve without concern for the integrity of the lead gasket. 11 Powell

Complimentary Equipment Chlorine Line Equipment Chlorine Transfer Hoses Metallic and non-metallic chlorine transfer hoses designed, manufactured, and tested to The Chlorine Institute, Inc. Pamphlet 6, Appendix A guidelines. Fully traceable back to manufacturer for 5 years. Handlebar Union The Powell Handlebar Union is a 3000# ASTM forged steel plated handlebar union with a Viton O-ring that allows for quick attachment of chlorine transfer hoses to stub pipes from tank truck angle valves. For longer product life, lubricate threads and Viton O-ring prior to each use. Chlorine Pressure Gauge Assemblies The Chlorine Pressure Gauge Assembly consists of a 4½ 30/0/300 pressure gauge mounted on a welded design diaphragm seal. Carbon steel upper housing with ½ NPT instrument connection tantalum diaphragm, nickel/chrome plated carbon steel lower housing on threaded seal, welded Hastelloy C lower housing on flanged seal. Gauge face and seal is filled with halocarbon oil. Chlorine Automatic Ball Valve Assembly This valve assembly consists of a 1 threaded ball valve with carbon steel body and Monel trim combined with a fail closed (air to open, spring to close) actuator with position indicator. Note: 80 psi instrument air required. Used in pressurized vapor, and line depressurizing applications. Chlorine Platform Automatic Plug Valve This 1 300# flanged, cast steel body, Hastelloy C trim, plug valve has vented plug and high cycle low emission stem seal with air to open, spring to close, fail closed actuator. Includes limit switch and visual position indicator. 80-psig air required. Used in pressurized liquid chlorine applications. 12

Gas Detection Equipment Complete gas detection systems are available for chlorine, sulfur dioxide and other gases. A typical system consists of an 8 or 16 channel controller, universal transmitters, individual gas sensors and the equipment required to calibrate the system. The controller is wall-mounted in a NEMA 4X enclosure, which can be centrally located. Recommended Spare Parts and Maintenance Items 3/16 X 2 Hitch Pin To secure MaxPro RA Mounting bracket to cylinder. Debris Screen For MaxPro RA Pneumatic Actuator; located in inlet of air motor. Control Panel Pilot Light Bulbs 130V Control Panel Control Panel Fuse Relay 115 Vac 4 pole Man 5 13 Powell

Complete Line of Powell Equipment Sodium Hypochlorite Process Systems For the Continuous Production of Sodium Hypochlorite. Chlorine Line Equipment Chlorine Pressure Switches, Transfer Hoses, Expansion Tanks, Pressure Gauge Assemblies, and More. Batch Sodium Hypochlorite System Produce 1,000 Gallon Batches of Sodium Hypochlorite. Sodium Hypochlorite Filter Systems Produce the Highest Quality Sodium Hypochlorite Available on the Market. Dilution System For the Dilution of Sodium Hypochlorite, Sodium Hydroxide, and Methanol. Emergency & Equipment Scrubbers Proven Performance - for use with Chlorine, Sulfur Dioxide, or Phosgene. Complete Chlor-Alkali Process Make chlorine, caustic soda, and hydrogen on-site for the production of sodium hypochlorite, ferric chloride, calcium hypochlorite, hydrochloric acid, and other chlorine derivatives, or to produce feed stocks for a variety of other chemicals. Instrumentation & Controls Controls and Equipment to Maximize Your Processes. Oxidation Reduction Potential Electrodes Automatically determine how much chlorine to add to a caustic solution to make sodium hypochlorite; Neutralize a solution of bleach with hydrogen peroxide or sodium sulfite; Measure the amount of chlorine in a brine solution; Neutralize chlorine with sodium sulfite; Use with Scrubber Systems to measure the reagent strength (caustic strength) of the caustic solution. Chlorine Unloading Equipment Railcar Padding Systems, Sophisticated Control Panels, and Eductors, and More. F o r m o r e i n f o r m a t i o n v i s i t w w w. p o w e l l f a b. c o m 14

Powell www.powellfab.com Powell 740 East Monroe Road St. Louis MI 48880 Phone: 888.800.2310 (Toll Free) 989.681.2158 (Local) Fax: 989.681.5013 email: info@powellfab.com website: www.powellfab.com www.valveclosures.com 7125.12312009 I:\Intranet\Marketing\SalesLit\PrintPDF s\valve Closure\MaxPro\SalesLiterature 2010, Powell All rights reserved.