VASCULAR DOPPLER PHOTO-PLETHYSMOGRAPHY PULSE VOLUME RECORDING ANKLE AND TOE BRACHIAL INDEX Vscular Specialist Angiologist Phlebologist Cardiologist Diabetologist The newest technology in a space-saving designideal for clinics or hospitals Bosco Medical Australia Pty Ltd 2/49 Borthwick Ave, Murarrie, QLD 4172 P: + 61 7 3399 1799 F: + 61 7 3395 6736 Email: orders@boscomed.com.au Website: www.boscomed.com.au
Atys has been a leading manufacturer of vascular assessment and diagnostic equipment for more than 25 years. It is renowned for designing innovative world beating products that fit the purpose and budget of busy clinicians. All our products are designed to achieve a balance of simplicity, ease of use and flexibility. The six BASIC devices range from vascular Doppler or photo-plethysmograph (PPG) to comprehensive systems incorporating all standard physiological measurements to diagnose peripheral arterial disease (PAD). FEATURES BASIC L BASIC 1 BASIC 2 BASIC 3.1 BASIC 3.2 BASIC 3.4 4 & 8 MHz Doppler Bilateral Venous Reflux Test (VRT) Bilateral PPG Bilateral PVR Doppler pressure Simultaneous PPG pressures 2 4 Doppler ABI PPG ABI 2 4 PPG TBI 2 4 PWV (Option) 2 4 PPG = PhotoPlethysmoGraphy, PVR = Pulse Volume recording, PWV = Pulse Wave Velocity. In the above table, the numbers are the numbers of channels. The small size of the BASIC makes it well adjusted for measurements by bedside, physician office, mobile service or anywhere space is at a premium. PORTABILITY, MOBILITY BASIC1, BASIC 2 and BASIC 3.1 are portable devices. As all the BASIC units, they are powered by the mains supply. They can also operate on an internal rechargeable battery and be fitted with a comfortable handle for optimized portability. The BASIC can be placed on an easily movable and ergonomic support. Two supports are available: Trolley I and Trolley Z. The trolleys are positioned precisely where they are needed and without effort. Trolley Z is especially recommended for BASIC 3.2 and BASIC 3.4. It offers facilities for the storage of the cuffs, sensors and probes. When not used, the cuffs can be placed on the handle shape dedicated storages.
Taking your Doppler device one step further. All the functions are fully integrated in the device. The BASIC is intuitive and easy to use. DOPPLER 4 MHz & 8 MHz continuous Doppler Bidirectional Doppler Arterial & venous Doppler Real-time colour spectral analysis Audio output: - Two loud speakers - Stereo, separated reverse and forward flows Six indices displayed in real time (Vs, Vd, Vm, Hr, RI, PI, S/D) Display of the curve or spectrum PHOTO-PLETHYSMORGRAPHY Ultrasensitive PPG sensors Record of the arterial waveform from the digits Diagnosis of venous insufficiency SYSTOLIC PRESSURE Automatic inflation and deflation of the cuff Automatic measurement The measured pressure remains adjustable USER INTERFACE 7 WVGA touch screen (TFT colour) Foot switch pedal RESOURCES Embedded PC Configurable protocols Configurable reports Storage of examination reports Direct and high-quality printing of full-page colour reports Export of the examination reports to a USB memory stick Vessel labelling Patient data input The BASIC is a portable device. The BASIC can be placed on an easily movable and ergonomic support. Two supports are available. The «trolley I» and «trolley Z» that can support a printer. Bosco Medical Australia Pty Ltd 2/49 Borthwick Ave, Murarrie, QLD 4172 P: + 61 7 3399 1799 F: + 61 7 3395 6736 Email: orders@boscomed.com.au Website: www.boscomed.com.au
FUNCTIONS CW vascular Doppler 4 MHz & 8 MHz Artial and venous Bidirectional Spectral analysis Display of curve and/or the spectrum Bilaterial arterial photo plethysmography Bilaterial venous photo plethysmorapy Venous Reflux Test Measurement of systolic pressure with Doppler This procedure is automatic. While the user holds the probe on the patient, a single click on the foot switch pedal allows the measureme nt of the systolic pressure. The cuff is inflated by the BASIC up to the proper occlusion pressure. The cuff is deflated slowly by the BASIC for an enhanced accuracy. The return of the blood flow is determined automatically by the BASIC. The software automatically places a cursor at the time location which is suspected as being the time of the return of the blood flow. The cuff pressure at this time is displayed. It is systolic pressure. However, it is the total responsibility of the system operator and the medical staff to modify the cursor location according to their medical training, and define the correct segmental pressure. FEATURES All functions come with automatic indices calculation User interface Foot switch Deflate Rates: Protocols: 7 WVGA touch screen display (colour) Foot switch 7 WVGA touch screen display (colour) Unlimited, fully configurable Save: Automatic Summary Screen: Interactive Export: ODT (open document text) report. The report can be open by WORD or LIBRE OFFICE on any PC. Reports: Useer defined templates Direct printing of high-quality, full-page, colour reports Advanced side-to-side and ipsillateral blood pressure comparison table Internal memory Capacity: 50 examination reports
MICROFLOWS - Pocket Doppler Vascular Specialist Angiologist Phlebologist Cardiologist Diabetologist FEATURES Detection of blood flow Functional study of the arterial network of the lower limbs Follow-up of diabetic foot Diagnosis of peripheral arterial disease Diagnosis of hand ischemia induced by arterio venous access Surveillance of graft patency Measurement of the penile pressure and flow rate Study of the venous flow in the lower limbs Bosco Medical Australia Pty Ltd 2/49 Borthwick Ave, Murarrie, QLD 4172 P: + 61 7 3399 1799 F: + 61 7 3395 6736 Email: orders@boscomed.com.au Website: www.boscomed.com.au
MICROFLOWS - Pocket Doppler FUNCTIONS BASIC 3.1 Product Number Description Basic 3.1 20 965 1 Peripheral Doppler Two channels photo-plethysmography module Systolic pressure measurement module with Doppler 15 561 4 MHz hand held probe 16 568 8MHz hand held probe 2 arterial sensors 18 690 1 arm/ankle n 4 cuff 1 arm/ankle n 5 or 6 cuff 05 663 Double foot switch pedal 14 140 200 double sided sticky pads for arterial PPG sensors 19 271 Trolley I 19 229 Trolley Z (supports printer) BASIC 3.2 Product Number 20 965 Description Basic 3.2 1 Peripheral Doppler Two channels photo-plethysmography module Systolic pressure measurement module with Doppler Channel Pulse Volume Recording module Channel systolic pressure measurement with PPG 15 561 4 MHz hand held probe 16 568 8MHz hand held probe 18 690 2 arterial sensors 2 arm/ankle n 4 cuff 2 arm/ankle n 5 or 6 cuff 2 toe/finger cuffs (120 x 25mm) 05 663 Double foot switch pedal 14 140 200 double sided sticky pads for arterial PPG sensors 19 271 Trolley I 19 229 Trolley Z (supports printer)