Automatically or individually calculated.

Similar documents
ProSoft Technology, Inc. Summary Regarding Alberta Energy and Utilities Board Directive 017 of May 2007

Applied Fluid Mechanics

Enter your parameter set number (1-27)

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

What is pressure relief valve? Pressure relief valve

GLOSSARY OF TERMS. Adiabatic Compression Compression process when all heat of compression is retained in the gas being compressed.

Gas Measurement Fundamentals Certification. Curriculum

Operational Settings:

CENTER PIVOT EVALUATION AND DESIGN

1800C and 1800C-HC Service Regulators

Pressures MAOP MOP OP

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources

A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 14.3/AGA REPORT NO. 3 - PART2 Paul J. LaNasa CPL & Associates

COMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item:

SB AXIAL FLOW VALVES

1800CPB2 Service Regulators

INTRODUCTION TO REGULATOR AND RELIEF VALVE SIZING. Introduction

UNIQUE ADVANTAGES OF PIPENET

General Specifications

Type 299 Pressure Reducing Regulators

299H Series Pressure Reducing Regulators

TOTAL CAPABILITIES IN THE PIPELINE INDUSTRY. UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

ASHRAE made significant changes in 2001 to the calculations. Fundamentals of Safety Relief Systems

1800CPB2 Pilot-Loaded Service Regulators

IRC 2011 All Rights Reserved

General Specifications

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

Chapter 22 Testing Protocols

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Tutorial. BOSfluids. Relief valve

North American 7339 High Pressure Gas Regulators

Safety Shut-off Valve SSV

LECTURE 20 FLOW CONTROL VAVLES SELF EVALUATION QUESTIONS AND ANSWERS

General Specifications

1805 Series Relief Valves

General Specifications

OVERVIEW OF THE CONVAL 10 SERVICE RELEASES

CONVAL HISTORY 07/09/2012

ERZ 2000-NG Flow Computer

Software Applications

Application Worksheet

Experiment 8: Minor Losses

Modeling a Pressure Safety Valve

SPRING-LOADED GAS PRESSURE REGULATOR

Hydronic Systems Balance

Industrial Regulator Series 1800/2000

Using the CONVAL software for the petrochemical plant control valves checking. Case study

SELECTION CRITERIA FOR SAFETY VALVE

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC

Research and optimization of intake restrictor for Formula SAE car engine

Excellent Vortex Flowmeter INSERTION Type BATTERY POWERED EX DELTA

INTRODUCTION TO GAS METERING

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

DESIGN DATA. Dry 105a. September 5, 2008

299H Series. 1% Accuracy for Fixed Factor Billing (PFM) I nlet Pressure up to 175 psig / 12.1 bar. Rugged Construction. Compact.

STANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK /J.02/0006-A4

ENGINEERING FLUID MECHANICS

I. CHEM. E. SYMPOSIUM SERIES NO. 85

Date of Issue: July 2016 Affected Publication: API Specification 16C, Choke and Kill Equipment, Second Edition, March 2015 ADDENDUM 1

Model 1800 PFM Series Regulator. Technical Bulletin

PE 2708 CTS & IPS GAS PIPE

Level MEASUREMENT 1/2016

Dimensioning of Safety Valves Auditorium Tecnimont

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

The flow direction must be observed during installation. It can be recognized by the following features: Flow direction. Gasket

SFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES:

DAV - P. Product Catalogue DAV - P. Air release & Vacuum Break Valves. (Plastic Air Valves) DAV - P. Edition 2012

Gerald D. Anderson. Education Technical Specialist

MODEL 240 GAS PRESSURE REGULATOR

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

The water supply for a hydroelectric plant is a reservoir with a large surface area. An outlet pipe takes the water to a turbine.

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Radar, Ultrasonic and RF Level Transmitters

Greenup Lock Filling and Emptying System Study

SIZING AND CAPACITIES OF GAS PIPING

The ERCB Directive 017 Overview

Pressure on Demand. Air Pressure Amplifiers

Model TB 3-16 TECHNICAL BULLETIN. Secure-Gard Pilot Operated Vent Valve (POVV) BENEFITS TYPICAL APPLICATIONS FEATURES

Type R622 Pressure Reducing Regulator

Subpart E. Pressure Testing

Part 192 Subparts J & K. Testing & Uprating

1213B2 Service Regulators Maximum Inlet Pressure 125 PSIG

Cover Page for Lab Report Group Portion. Head Losses in Pipes

FUEL GAS FIRING CONTROL RJ (Dick) Perry Safety Systems Consultant 6 June 2016

Experiment (13): Flow channel

MODEL 273PL GAS PRESSURE REGULATOR

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Vapor Recovery from Condensate Storage Tanks Using Gas Ejector Technology Palash K. Saha 1 and Mahbubur Rahman 2

SOFTWARE APPLICATIONS DETAILS. Abstract This document is the calculation details for working with KELTON Standard Calculation Package (FLOCALC.

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

CERTIFICATES OF COMPETENCY IN THE MERCHANT NAVY MARINE ENGINEER OFFICER

Software Applications

44 (0) E:

CHAPTER 7 : SMOKE METERS AND THEIR INSTALLATIONS

1800C & 1800C-HC Service Regulators

Generating Calibration Gas Standards

Transcription:

GASCalc 5.0 GASCalc 5.0 is a Windows based suite of calculation tools for the natural gas professional. Routines are provided for calculating numerous parameters associated with the design and operation of natural gas gathering, transmission, distribution, plant, or fuel piping systems. Its robust set of calculation routines and features include... GASCalc 5.0 Calculations & Features GAS PROPERTY VALUES Physical Properties Calculates various physical properties including heating value, specific gravity (ideal or real), specific heat ratio, and viscosity for a specified gas composition. Supported Heating Value Methods: AGA 8-1992 GPA 2172-1986 GPA 2172-2009 GPSA - 1998 Thermodynamic Properties Calculates various thermodynamic property values including enthalpy, entropy, constant pressure and volume specific heat values for a specified gas composition at specified pressure and temperature conditions. Supported Heating Value Methods: AGA 10-2003 Compressibility Calculates compressibility, density, and supercompressibility of a gas composition at specified pressure and temperature conditions. Automatically or individually calculated. AGA 8-1985 AGA 8-1992 AGA NX19 GERG - 1988 GPA 2145-2009 GPSA Sonic Velocity Pressure, Volume, Temperature (P, V, T) Atmospheric Pressure Average Pressure Average Temperature METER VALUES Fixed Pressure Factor Standard Volume Calculates the speed of sound value for User specified pressure and temperature conditions and gas composition. Calculates associated pressure, temperature, and volume values for specified conditions. Calculates the atmospheric pressure for a given elevation or an elevation based on pressure value. Automatically or individually calculated. Calculates the average pressure in a pipe segment or pair of values. Calculates the average temperature in a pipe segment or pair of values. Calculates required adjustment factor for gas measured using a fixed pressure factor. Calculates the equivalent standard (base) volume for a volume measured at nonstandard conditions. AGA 10-2003 GPSA AGA Measurement ASHRAE - 2009 Handbook Of Chemistry & Physics ISHM NOAA - 1976

Base Conditions Conversion Volume Comparison Converts a volume at one set of standard (base) conditions to the equivalent volume at another set of standard (base) conditions. Calculates the difference in volumes at different standard (base) conditions. Useful for calculating lost and unaccounted for values. Orifice Meter Calculates values associated with measurement by an orifice meter. Includes calculation of orifice diameter, pressure differential, and flow values. AGA 3-1985 AGA 3-1992 ISO - 5167 Diaphragm Meter Rotary Meter Turbine Meter diaphragm displacement meters. rotary meters. turbine meters. GRI/SWRI Rockwell Sprague Cone Meter Calculates values associated with measurement by a v-cone meter. Pulse Output Meter Calculates values associated with measurement by a pulse output meter. McCrometer AGA 7 Meter MatchMaker Flow Limiting Device PIPE VALUES Pipe Flow Service Line Sizing Blowdown Time Pipe Volume Finds appropriate meters based on specified sizing criteria. Calculates values associated with sizing flow limiting orifices and nozzles. through a single or series of pipe segments. Allows calculation of diameter, length, flow rate, roughness, pressure drop, and downstream temperature. Allows fittings to be attached. through a service line - from main tap to termination riser. Allows fittings to be attached and inclusion of EFV. Calculates various EFV values including maximum protected length and reset time. Calculates the estimated time required to vent a line to the atmosphere. Calculates the volume of gas contained in a single or series of pipe segments at specified beginning and ending conditions. AGA 7 AGA partially and fully turbulent Colebrook Cox Darcy-Weisbach IAPMO low and high IGE3 low, medium, general IGT-Improved IMC high and low Mueller high and low Oliphant Panhandle A and B Pole LP Spitzglass high and low Weymouth

Fill Time Vent Time Purging & Clearing Steel Pipe Design Formula Plastic Pipe Design Formula Maximum Allowable Operating Pressure (MAOP) Bending Stress - Span Hoop Stress External Loading Thermal Expansion Total Pipe Stress Buoyancy Permeation Hydraulic Diameter Flow Area VALVES & FITTINGS Regulator & Monitor System Regulator & Relief Valve System / 2-Stage filling a single or series of pipe segments at specified beginning and ending conditions. venting a single or series of pipe segments at specified beginning and ending conditions. purging and/or clearing a pipe segment. Calculates design values for steel pipe segments. Calculates design values for plastic pipe segments. Calculates the MAOP value for a pipe segment based on User specified values and conditions. Calculates values associated with a pipe span. Supports pinned and fixed end conditions. Calculates hoop stress and SMYS comparison for User specified conditions. Calculates stress values associated with roadway, railway, and unclassified crossings. Calculates stress and change in length values associated with the temperature change of a pipe segment. Calculates the total combined stress for a pipe segment. Calculates buoyancy and weight requirements for wet environment crossings. Calculates the volume gas lost by way of permeation through a pipe wall. Calculates the hydraulic diameter of plastic pipe based on dimensional values and tolerances. Calculates the flow area of a pipe or opening based on User specified conditions. associated with flow through a regulator and monitor pressure control station. associated with flow through a regulator and relief valve pressure control station. Supports single or two stage stations. API 15LE API 1102 ASME - GPTC Generic

Regulator Values Fitting Values Valve Values Relief Valve Values Relief Valve & Piping System Station MatchMaker Device MatchMaker MISCELLANEOUS CALCULATIONS Gas Loss From Damage Compressor Values Well Flow Pipe Tap Velocity Reynolds Number Container Volume UTILITY CALCULATIONS Unit Conversions through a regulator. through a line fitting (elbow, tee, or valve) using equivalent length values. through a line valve. through a relief valve. associated with flow through a relief valve system. Finds appropriate stations based on specified design and operating conditions. Finds appropriate devices based on specified sizing criteria. Estimates the volume of gas lost from a punctured or severed line. through a compressor unit. through a well casing. through a pipe side wall tap. Calculates the flow velocity through an opening. Calculates the Reynolds Number associated with User specified flow conditions. Calculates the volume of various shaped containers. Calculates dimensional equivalent of User specified value. Supports over 100 different dimensional units. American Meter American Meter AFV Equimeter/Rockwell Fisher Grove 80 Grove 900 ISA - S75.01 Mooney Table Based Values American Meter AFV API 520 ASME BPV Equimeter/Rockwell Fisher Mooney Table Based Values

Energy Conversions Value Interpolation Value Extrapolation Calculates energy equivalent of User specified energy unit. Supports 30 different energy types. Calculates an intermediate value from a set of specified table values. Automatically or individually calculated. Calculates an extended value from a set of specified table values. SELECTED PROGRAM FEATURES Dimensional Units - Supports standard US, metric, and diverse unit systems. Includes a wide range of industry related units. Applications - Allows external applications to be executed directly from the main menu. User Interface - Provides intuitive and easy to understand and use fill-in-the-blank data screens for interacting with the many calculation routines. Pipe & Device Property Tables - A comprehensive set of tables provides values required by the various pipe, fittings, devices and equipment calculations. Property Table Editor - An extensive editor is provided for modifying the Fitting, Compressor, Pipe, Valve, Regulator, Well, Relief Valve, Meter, and EFV Property Tables which support the various calculation routines. The User can add, delete, and modify the models contained in the various Property Tables to meet their individual specific requirements. Value Selection Tables - An extensive set of tables are provided to assist in the selection of certain required calculation values. Such as SMYS, HDB, HDS, MOE, Material Density, and Thermal Expansion Coefficients. Device Selector - A handy device selection utility is provided to allow efficient selection of regulators and relief valves by selecting the Manufacturer, Model, Size, Orifice etc. Many of the calculation routines are also available through the GASCalc 5.0 Application Program Interface (API). The API allows access to the supported calculation routines by way of programmatic function calls, allowing the User to create and access the calculation routines through their own or a custom developed user interface. The API is available at additional charge.