MESP-202H INSTALLATION INSTRUCTIONS AND OWNER S MANUAL. HF and HF FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS

Similar documents
STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE

Chapter 10: Bidirectional Flow Controls

Full Range Pressure Compensating Variable Flow Control

PRESSURE COMPENSATORS TECNORD

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

Lesson 6: Flow Control Valves

Electro-Proportional Valves. Selection Guide HYDRA FORCE

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

MADILL 24.7" 365 TILT SET-UP PROCEDURE WITH REXROTH VALVE ON MACHINE

Copyright, 2005 GPM Hydraulic Consulting, Inc.

BACK PRESSURE / SUSTAINING

Hydraulics. Hydraulic Pressure Control

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

P.C. Flow Regulator Valve Series FR101. General Description

BACK PRESSURE / SUSTAINING

PTS1120TSJB PTS2120TSTSJB

P r o d u c t R a n g e Data sheet: P

SINGLE VALVE WITH LOW-FLOW BYPASS

Hydraulic Reliability & Preventive Maintenance Report

Models 106-RF / 206-RF Rate of Flow Control Valve

PVK OPEN LOOP PUMPS. Bulletin E

IFP C175-* REMOTE CONTROL RELIEF VALVE

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

ANTI SHOCK RELIEF VALVE

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Waterous Relief Valve

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

CASH VALVE TYPE KP BACK PRESSURE VALVES

Cartridge Valves Technical Information Motor Mount HICs Quick Reference

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

MWEA MAINTENANCE SEMINAR SPECIALTY VALVES POWER GLOBES

PVQ 13 A2 R SE 1 S 20 C-11 D

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

WORKHOLDING APPLICATION BOOKLET

Electrically Operated Pressure-Relief Cartridge, Size 10

Bulletin 2537-M2/USA Service Bulletin Series PRM

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Whisper Pump Service and Repair Guide

Monoblock Directional Control Valve RMB 202

Axial piston pumps type PVC

Axial piston pumps type PVC

Priority (Swing) Motors Data and Specifications

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

[You may download this article at: ]

Pilots Specifications

SDM to 8 sections monoblock valve D1WWDA02A

TECHNICAL DATA. than the water inlet pressure to the concentrate

Document How to Set Single Stage Press Pressures

Linde Hydraulics Corporation, P.O. Box 82, Canfield, Ohio 44406

Reverse Osmosis System Installation Guide and Operation Manual.

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

Inverse Proportional Pressure-Relief Cartridge, Size 10

Proportional Directional Valve System

TANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING

Hydronic Systems Balance

PVV Open Loop Pumps. Bulletin E

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

SERVICE INSTRUCTIONS PVWJ A-FRAME PUMPS -011/-014/-022 FOR TYPE P-C AND P-K SOFT START PRESSURE COMPENSATING CONTROLS

Proportional Valve Group PVG 32 minibooster

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump

Leak free Pipe Rupture Valve for Excavators

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Directional Controls

Discharge Relief Valve Operation & Maint.

Section 2 Proportional Quick Exhaust

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

WW-730. Pressure Sustaining/Relief Control Valve

Leak-Free Load-Control Valve SAE ½ psi flange

(Refer Slide Time: 0:26)

Cover headline. Cover subheadline. Check Valves

Proper Pump Installation Practices

Inverse Prop. Pressure-Relief Cart., Size 2 4

SC HYDRAULIC ENGINEERING CORPORATION

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

Pressure Independent Control Series

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

SINGER MODEL 106/206-RPS-L&H

Directional Control valves

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

LINDGREN-PITMAN, INC. LS-3 / LS-4 Line Setter

AS0403 Aircraft Systems & Instruments G.Mahendra Perumal

Bobtail DOT 407 / 412 Vacuum

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40

SERVICE INSTRUCTIONS P-2 DUAL PRESSURE COMPENSATOR, SERIES F1U CONTROL

MANUAL BE SERIES Test Benches

Bulletin 2533-M3/USA Service Bulletin. Series PR25MA, PR25P, PR25S, PR32P, PR32S. Effective: July 1, Pilot Operated Pressure Reducing Valves

SERVICE INSTRUCTIONS P-A OR P-B ELECTRONIC PRESSURE COMPENSATOR, SERIES F1U CONTROLS

Inert Air (N2) Systems Manual

Proportional Pressure-Relief Cartridge Valve, Size 2...4

SERVICE INSTRUCTIONS P-C SINGLE PRESSURE - SOFT START, SERIES F1U CONTROL

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Accu-Tab Systems 1000 Series by Axiall Corporation

Transcription:

MESP-202H INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS HF42407-07 and HF51912-09 Muncie Power Products, Inc.

TABLE OF CONTENTS DESCRIPTION PAGE Features... 3 Hydraulic Specifications... 3 Original MESP 202H Workports... 4 Revised MESP 202H Workports... 5 Original Cartridge Designations, Function, and Part Numbers... 6 Original Open Center Schematic... 7 Original Load Sense Schematic... 8 Revised Cartridge Designations, Functions, and Part Numbers... 9 Revised Open Center Schematic... 10 Revised Load Sense Schematic... 11 Relief Valve Adjustment... 12 Detailed Description of MESP-202H...13-15 Original MESP202H HF42407-07 Revised MESP202H HF51912-09 * Changes to revised model: 1. Eliminated CV2 (HF42407-07) 2. Moved PGP gage port from side (on HF42407-07) to front face. 2

MESP-202H FEATURES FOR GEAR PUMP APPLICATIONS Unloader for low pressure loads when not operating equals low heat and low energy consumption. DIRECT ACTING SOLENOID PROPORTIONAL VALVES For consistent and predictable flow control. POST PRESSURE COMPENSATION Flow stability under varying load. VERSATILE 2 DESIGN OPTIONS Load Sense (variable displacement pumps) or Open Center (fixed displacement pumps). 2 ADJUSTABLE RELIEF VALVES One inlet relief and one output relief. HYDRAULIC SPECIFICATIONS Maximum Inlet Flow... 30 GPM Maximum System Pressure...3,000 PSI Unloaded Pressure Drop... 40 PSI AT 25 GPM Auger Flow (Proportional)... 15 GPM (Pressure Compensated) Spinner Flow (Proportional)... 7 GPM (Pressure Compensated) Main Relief... Factory Setting 2,200 (PSI Adjustable) Spreader Relief... Factory Setting 2,000 (PSI Adjustable) 3

ORIGINAL MESP-202H WORKPORTS T2 LS PGP P2 T P A S HF42407-07 DESIGNATION DESCRIPTION SIZE (SAE) T TANK 12 T2 TANK 12 P PUMP 12 P2 PUMP 16 A AUGER 12 S SPINNER 12 LS LOAD SENSE 4 PGP PUMP GAGE PORT 6 4

REVISED MESP-202H WORKPORTS APRIL 1, 2009 A T S P HF51912-09 DESIGNATION DESCRIPTION SIZE (SAE) T TANK 12 T2 TANK 12 P PUMP 12 P2 PUMP 16 A AUGER 12 S SPINNER 12 LS LOAD SENSE 4 PGP PUMP GAGE PORT ¼" NPTF 5

ORIGINAL MESP-202H MANIFOLD CARTRIDGE DESIGNATIONS, FUNCTIONS, & PART NUMBERS PV1 Spinner Pressure Compensated Flow Control NXPV7030A0N00 PV2 Auger Pressure Compensated Flow Control NXPV72200N00 EV1 Pump Unloader NXEV16S340N10 LS1 Load Sense Shuttle NXLS08300N00 RV2 Main System Relief NXRV0820H0N3322 CV2 LS Check Valve NXCV04200N05 CV1 Boost Pressure Check NXCV08200N270 RV1 Auger/Spinner Relief NXRV0820H0N1820 SV1 Pump Unloader Pilot NXSV08210N00 HF42407-07 6 COIL SV1 PV1 PV2 PART NUMBERS NX4303612 NX4303212 NX4303212

ORIGINAL MESP-202H OPEN CENTER P2 SCHEMATIC P S PGP CV1 PV1 LS1 A ORF1 PV2 EV1 SV1 RV2 CV2 RV1 T T2 HF42407-07 VALVES LS HF42407-07 PORTS HF42407-07 DESIGNATION DESCRIPTION SIZE (SAE) T TANK 12 T2 TANK 12 P PUMP 12 P2 PUMP 16 A AUGER 12 S SPINNER 12 LS LOAD SENSE 4 PGP PUMP GAGE PORT 6 7

ORIGINAL MESP-202H LOAD SENSE P2 SCHEMATIC P PGP CP2 PV1 LS1 S A ORF1 PV2 EV1 CP1 RV2 CV2 RV1 T T2 LS HF42407-07 VALVES HF42407-07 PORTS CV1 Replaced with CP2 (NXCP0820N) in LS Configuration SV1 Replaced with CP1 (NXCP0820N) in LS Configuration HF42407-07 DESIGNATION DESCRIPTION SIZE (SAE) T TANK 12 T2 TANK 12 P PUMP 12 P2 PUMP 16 A AUGER 12 S SPINNER 12 LS LOAD SENSE 4 PGP PUMP GAGE PORT 6 8

REVISED MESP-202H MANIFOLD 4/1/09 CARTRIDGE DESIGNATIONS, FUNCTIONS, & PART NUMBERS PV1 Spinner Pressure Compensated Flow Control NXPV7030AM0N00 PV2 Auger Pressure Compensated Flow Control NXPV7220M0N00 EV1 Pump Unloader NXEV16S340N10 LS1 Load Sense Shuttle NXLS08300N00 RV2 Main System Relief NXRV0820H0N3322 CP1 Cavity Plug NXVC042 CV1 Boost Pressure Check NXCV08200N270 RV1 Auger/Spinner Relief NXRV0820H0N1820 SV1 Pump Unloader Pilot NXSV0821K0N0 HF51912-09 COIL SV1 PV1 PV2 PART NUMBERS NX4303612 NX4303212 NX4303212 9

REVISED MESP-202H OPEN CENTER P2 SCHEMATIC 4/1/09 P S PGP CV1 PV1 LS1 A ORF1 PV2 EV1 SV1 RV2 CP1 RV1 T T2 LS HF51912-09 10

REVISED MESP-202H LOAD SENSE P2 SCHEMATIC 4/1/09 P S PGP CP3 PV1 LS1 A ORF1 PV2 EV1 CP2 RV2 CP1 RV1 T T2 LS HF51912-09 SV1 Replaced with CP2 (NXCP0820N) in LS Configuration CV1 Replaced with CP3 (NXCP0820N) in LS Configuration 11

MESP-202H RELIEF VALVES HF402407-07 To Decrease the Pressure Settings HF51912-09 1. The tools required to adjust the relief valves include a 5 ¹ 6" Allen drive and a ¼" Allen drive. 2. Remove the caps from both of the relief valves. Oil may seep out of these cartridges when the caps are removed and the system is operating. 3. Place A gage in the PGP port. If not accessible, tee a gage in between the Pump Outlet and the Pressure Port (P) of the MESP202H. 4. Start the truck and Deadhead flow at either the Auger or Spinner. 5. Observe the gage in the L.S. port and adjust the auger/spinner relief CCW to the desired pressure. 6. Observe the Gage in the (PGP) port. Adjust the main relief CCW until it is approximately 200 P.S.I. higher than the L.S. gage. To Increase the Pressure Settings (3,000 P.S.I. Max.) 1. The tools required to adjust the relief valves include a 5/16 Allen drive and a ¼ Allen drive. 2. Remove the caps from both of the relief valves. Oil may seep out of these cartridges when the caps are removed and the system is operating. 3. Place A gage in the PGP port. If not accessible, tee a gage in between the Pump Outlet and the Pressure Port (P) of the MESP202H. 4. Start the truck and Deadhead flow at either the Auger or Spinner 5. Both reliefs will need to be adjusted in small increments together. 6. Adjust the Auger/Spinner relief CW while observing both gages stop turning when there is no change in the gage. 7. Adjust the main relief CW while observing both gages stop turning when there is no change in the gage. 8. Repeat steps 5 and 6 until you arrive at desired P.S.I. 9. The main relief (PGP pressure) should have final setting about 200 P.S.I. higher than the spinner/auger relief (L.S. pressure). 12

DETAILED DESCRIPTION OF THE ORIGINAL AND REVISED MESP-202H HF42407-07 AND HF51912-09 REFERENCE CIRCUIT SCHEMATIC FOR HF42407-07 OR HF51912-09 Pump Gage Port (PGP) Indicates the inlet pressure from the pump. This pressure will be approximately 300 PSI higher than the actual pressure at the motors due to the load-sensing operation of the valve network. Load Sense (LS) Indicates the pressure of the load (motor). If more than one function is operating concurrently then the higher load pressure is seen. There will only be a pressure from the LS port if a function is operating. The LS port can be used to adjust the spinner/auger relief. Remember, the PGP will display a pressure approximately 300 PSI higher than the pressure in the LS port while a function is operating. EV1 Pump bypass and pre-pressure compensation cartridge. EV1 is a normally closed -two position - two way -pilot cartridge. It can provide a very low pressure path for pump flow to escape to tank. This is its primary function when no functions are operating. The bypass pressure of the pump in this state will vary from about 20-60 PSI depending upon the pump flow. This pressure will show at PGP. The path to tank is opened by pump pressure being applied to the left side pilot of EV1 which forces it open. The right side pilot line of EV1 is drained to tank through SV1 (Unloader Solenoid Valve) to allow this to happen. Solenoid Valve (SV1) Unloader solenoid valve. SV1 is a normally open- two position - two way solenoid operated cartridge. When its solenoid is not energized it provides a drain path for the pilot pressure on the right side of EV1. This allows for pilot pressure on the left side of EV1 to push it open and expose a low pressure path for the pump flow to escape to tank. SV1 will energize whenever any function of the MESP 202H is operating. This closes the pilot drain on the right side of EV1 and that in-turn cause EV1 to begin shutting off the pump flow escape to tank. Pump flow is now forced to move toward motor valves as required. If SV1 was energized or manually overridden (if equipped) without any other system valves functioning, the pressure at PGP would be approximately 300 PSI. The L.S. port would not have pressure. Check Valve (CV1) Boost pressure check valve. CV1 is a simple spring biased ball check cartridge. Its purpose is to raise the differential or boost pressure between PGP and LS by a margin of approximately 300 PSI. It comes into play when SV1 is energized. At that point the pilot 13

pressure on the right side of EV1 can only drain through CV1. CV1 s internal bias spring is set for 270 PSI. That means the pressure of EV1 s pilots (both sides) must build to at least 270 PSI before the right side pilot can drain through CV1 and allow EV1 to begin to open. This boost pressure is required to allow flow to get through other cartridge valves in the system to operate functions. When CV1 has a load-sense pressure applied to its right side which is communicated from LS1 (Load Shuttle) this will add to the pressure required for EV1 to drain its right side pilot and open. For example, if the load-sense pressure for a spreader motor is 1000 PSI, this will be added to the (270 PSI) spring bias pressure of CV1. Now EV1 cannot begin to open its path to tank until the pump pressure has achieved something slightly higher than 1,270 PSI. PGP would display 1,270 + PSI and L.S. port would display 1,000 PSI. In this way the system will always attempt to sustain a differential or boost pressure of approximately 300 PSI. Relief Valve (RV2) Main system relief valve. RV2 is an adjustable relief cartridge that is used in conjunction with EV1 to limit the maximum pump pressure. RV2 is located in the pilot path on the right side of EV1. It is preset from the factory at 2,200 PSI. This can be adjusted to a maximum of 3,000 PSI. When RV2 opens it begins to drain the pilot on the right side of EV1 at whatever pressure RV2 has been set. The pressure of the pump and the left side of EV1 will build slightly higher and force EV1 to begin to open and provide a tank path for the pump. Orifice (ORF1) Load sense drain orifice. ORF1 provides a controlled drain for the load-sense pilot line/ev1 control pilot. Its function is to ensure that the pressure cannot be trapped in this pilot and result in EV1 not being able to fully open at low pressure when required. Check Valve (CV2) (ONLY HF42407-07) Load-sense check valves. This check valve only allows flow to travel in one direction back to the pump. Proportional Valve (PV1) Spinner flow control valve. PV1 is a proportional solenoid flow control valve that also incorporates pressure compensation. In its unenergized state it provides a blocked path between the pump flow and the spinner work port. When it is energized it provides an increasing orifice opening to flow as a result of increasing electric current to its solenoid coil. Its range of flow control is 0-7 gallons-perminute. A second internal stage of PV1 provides pressure compensation of the flow control. This stage will react to changes of pump pressure conditions relative to the spinner load pressure demands. If the pressure difference goes too high the compensator stage will squeeze down to prevent extra flow from shooting through the proportional valve orifice setting. The basis of stable flow control requires this feature. Proportional Valve (PV2) Auger/Conveyor flow control valve. PV2 is a proportional solenoid flow control valve that also incorporates pressure compensation. In its non-energized state it provides a blocked path 14

between the pump flow and the auger/conveyor work port. When it is energized it provides an increasing orifice opening to flow as a result of increasing electric current to its solenoid coil. Its range of flow control is 0-15 gallons-per-minute. A second internal stage of PV2 provides pressure compensation of the flow control. This stage will react to changes of pump pressure conditions relative to the auger/conveyor load pressure demands. If the pressure difference goes too high the compensator stage will squeeze down to prevent extra flow from shooting through the proportional valve orifice setting. The basis of stable flow control requires this feature. Relief Valve (RV1) Spreader pressure relief. RV1 limits the pressure of the spreader motor circuits. This gives independent protection to the motors from the rest of the system. Load Sense (LS1) Load shuttle cartridge. LS1 is similar to two check valves set back-to-back. Its purpose is to communicate the load pressure of the highest spreader motor pressure back to CV1. 15

A Member of the Interpump Group IN09-05 (Rev. 02-18) 201 East Jackson Street Muncie, Indiana 47305 800-367-7867 Fax 765-284-6991 info@munciepower.com www.munciepower.com Specifications are subject to change without notice. Visit www.munciepower.com for warranties and literature. All rights reserved. Muncie Power Products, Inc. (2009)