INSTALLATION & OPERATION MANUAL. Dual Duct VAV Terminals. Redefine your comfort zone.

Similar documents
KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation Instructions

Installation Instructions

BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

GM Series Dual-Block Multi-Function Gas Control Valves

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

INSTRUCTION MANUAL. January 23, 2003, Revision 0

INSTALLATION & OPERATION MANUAL AORCS ATLAS OPERATING ROOM CEILING SYSTEM. Redefine your comfort zone.

Instruction Manual. PE-25/32/37 Tapping Machines. POLYTAPP Valves

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Operating Instructions for Cobra and Lynx Duct Leakage Testers

92831 TEL: (714) FAX:

Natural Gas to L.P. Gas Conversion Kit

USER MANUAL. JET TST and JET TST S.

MAYHEM MAYHEM OWNERS MANUAL. Paintball Guns International. Manufactured by

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Operator: Save these instructions for future use!

200 A, 15 and 25 kv class loadbreak bushing insert installation instructions

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Model 130M Pneumatic Controller

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

TV-114 TV-114-A Wind Speed Sensor User s Manual

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Installation Instructions

Operating Instructions Part No

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

Operator Manual Gas Griddle / Cheesemelter

36H SERIES Combination Gas Valve

Natural Gas to L.P. Gas Conversion Kit

COOPER POWER SERIES. 600 A 15, 25 and 35 kv class bushing adapter installation instructions. Deadbreak Apparatus Connectors MN650058EN

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

! Warning, refer to accompanying documents.

OPERATOR S MANUAL SPREADER. CSS, VNQ [For Combine Harvester AW82V] Original instructions

10 DRIP NOZZLE WATERING DRIP KIT Model / Model 46095

ATS430 turbidity sensor Retractable insertion assembly

G R AV I T Y B I K E S TA N D OWNER S MANUAL

TWB Shoulder Retractors

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

G96 Series BASOTROL Dual Operator Valve

Installation, Operation, and Maintenance Manual

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

Air Intake Snorkel Kit

installation instructions

Constant Pressure Crude Oil Container Model CPCCP

Pressure Dump Valve Service Kit for Series 3000 Units

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

RGC-IR Remote Gas Calibrator for IR400

The World s Best Adductors

DTG - LCD Digital Temperature Gauge USER MANUAL

Wilo Triple Duty Valve / Triple Service Valve Installation and operating instructions

Medial Hardware USER MANUAL MTMD-42. Stealth s User Manual and Maintenance Guide for Medial Thigh Support

VERTICAL SURFBOARD CARRIER READ ME! IMPORTANT WARNING!

CSA Sample Draw Aspirator Adapter Operator s Manual

OC Panel High Limit Aquastat Kit, Manual Reset p/n

DT400/436 Tee Connector Installation Instructions

Pressure Dump Valve Service Kit for Series 2300 Units

Tire Inflation Cage Kit For servicing only single piece automotive, and most light truck tire/wheel assemblies

TWB Shoulder Retractors

Your safety and the safety of others are very important.

Dual Solenoid Gas Valve Installation

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

CTC 1000 Series One-Pipe, Pneumatic Room Thermostat, Single Temperature

Medical Gas Control Panel

Upper Extremities USER MANUAL ARMS-ESF3GP. Stealth s User Manual and Maintenance Guide for the 3G Fixed Elbow Stop

COOPER POWER SERIES. 600 A 15, 25, and 35 kv class PUSH-OP bushing adapter cap installation instructions. Deadbreak Apparatus Connectors MN650050EN

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

GAS FUEL VALVE FORM AGV5 OM 8-03

Chapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

MEGR-1912 Instruction Manual

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Air Operated Hydraulic Pumping Systems to 50,000 psi

Installation, operating and maintenance Instructions for Seemag bypass level indicator

MODEL 300 BACKLAPPER OWNERS MANUAL

709 and 710 Stud Punches

Product Safety Information

Operator: Save these instructions for future use!

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

COOPER POWER SERIES. UltraSIL Polymer-Housed Distribution-Class MOV Surge Arrester Installation Instructions. Surge Arresters MN235006EN

RTD Temperature sensor TH11

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

XpressFill XF4500C Counter Pressure Can Filler. Operating Instructions

H4802, H4802-1, H , and Pole Tampers

Arbor Terminator Press Operation Manual For IDT Connectors Order No Engineering No: AM

Interface Devices, Inc. Hydraulic Mini Mule

Incorrect installation, adjustment, or misuse of this burner could result severe personal injury, or substantial property damage.

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

ACCESSORY KIT INSTALLATION INSTRUCTIONS

HYDRAULIC WINCH FOR AUGERS UP TO WR10 X 71 / W130 X 41 ASSEMBLY & OPERATION MANUAL

Cover Page for Lab Report Group Portion. Pump Performance

CentriFlow Meter Integrated Air Entrainment System

Installation and Service Manual

RG1200 Service and Repair Manual

Transcription:

INSTALLATION & OPERATION MANUAL Dual Duct VAV Terminals

IOM Dual Duct VAV Terminals IMPORTANT! READ BEFORE PROCEEDING! GENERAL SAFETY GUIDELINES This equipment is a relatively complicated apparatus. During installation, operation maintenance or service, individuals may be exposed to certain components or conditions including, but not limited to: refrigerants, UV, materials under pressure, rotating components, and both high and low voltage. Each of these items has the potential, if misused or handled improperly, to cause bodily injury or death. It is the obligation and responsibility of operating/service personnel to identify and recognize these inherent hazards, protect themselves, and proceed safely in completing their tasks. Failure to comply with any of these requirements could result in serious damage to the equipment and the property in which it is situated, as well as severe personal injury or death to themselves and people at the site. This document is intended for use by owner-authorized operating/ service personnel. It is expected that these individuals possess independent training that will enable them to perform their assigned tasks properly and safely. It is essential that, prior to performing any task on this equipment, this individual shall have read and understood this document and any referenced materials. This individual shall also be familiar with and comply with all applicable governmental standards and regulations pertaining to the task in question. Safety Symbols The following symbols are used in this document to alert the reader to areas of potential hazard: danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. caution identifies a hazard which could lead to damage to the machine, damage to other equipment and or environmental pollution. Usually an instruction will be given, together with a brief explanation. warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. note is used to highlight additional information which may be helpful to you. 2 IOM - Dual Duct VAV Terminals

CHANGEABILITY OF THIS DOCUMENT In complying with Titus policy for continuous product improvement, the information contained in this document is subject to change without notice. Titus makes no commitment to update or provide current information automatically to the manual owner. Updated manuals, if applicable, can be obtained by contacting the nearest Titus office or accessing the Titus website. CHANGE BARS Revisions made to this document are indicated with a line along the left or right hand column in the area the revision was made. These revisions are to technical information and any other changes in spelling, grammar or formatting are not included. Operating/service personnel maintain responsibility for the applicability of these documents to the equipment. If there is any question regarding the applicability of these documents, the technician should verify whether the equipment has been modified and if current literature is available from the owner of the equipment prior to performing any work on the unit. IOM - Dual Duct VAV Terminals 3

IOM Dual Duct VAV Terminals Table of Contents General Safety Guidelines...2 Safety Symbols...2 Changeability of this Document...3 Table of Contents...4 Figure(s)...4 Section 1 - Installation Procedure...5 Inspection...5 Supporting the Assembly...5 Duct Connections...5 Field Wiring...6 Control Start-up, Operation...6 Calibration Instructions...6 Replacement Parts...6 Figure(s) Figure 1 - Dual Duct Recommended Hanger Bracket Locations...5 4 IOM - Dual Duct VAV Terminals

Section 1 - Installation Procedure RECEIVING INSPECTION After unpacking the terminal, check it for shipping damage. If any shipping damage is found, report it immediately to the delivering carrier. Store units in a clean, dry location prior to installation. note Do not insert duct work inside the inlet collar. Inlet duct should be installed in accordance with SMACNA guidelines. caution Do not use the flow sensor, connecting tubing, or damper shaft linkage as a handle to lift or move assembly. Damage to the flow sensor or controls may result. SUPPORTING THE ASSEMBLY Dual duct terminals are not light enough to be supported by the duct work itself. The terminal should be supported directly. Straps screwed directly into the side of the terminal, threaded rod through the optional hanger brackets (see Figure 1), or the method prescribed for the rectangular duct on the job specifications may be used. The bottom should be left clear where there are access panels. Important: If equipped with pneumatic controls, the terminal must be mounted right side up. It must be level within+ or -10 degrees of horizontal, both parallel to the air flow and at the right angle of air flow. The control side of the terminal is labeled with an arrow indicating UP. The first letter of the model number (P) indicates pneumatic controls. Most electronic units (A-analog controls and D-digital controls) can be installed in any orientation. Check with the local TITUS representative for verification. The outlet end of EDV and MDV series units are designed for use with slip and drive duct connections. A rectangular duct the size of the terminal outlet should be attached. Inspect the Aerocross inlet flow sensor for shipping damage, and ensure that the high (green) and low (red) tubes are attached. Provide at least 1½times the inlet duct diameter of straight duct for optimum control accuracy. For more information on our Aerocross, see the Aerocross Flow Sensor Application Guide. D 2 Typical DUCT CONNECTIONS Slip each inlet duct over the inlet collar of the terminal. Fasten and seal the connection by the method prescribed by the job specification. Hanger Strap Location or Hanger Bracket Option. The diameter of the inlet duct D in inches must be equal to the listed size of the terminal; e.g. a duct that actually measures 8 inches must be fitted to a size 8 terminal. The inlet collar of the terminal is made 1/8 inch smaller than listed size in order to fit inside the duct (see Figure 1). The supply ductwork must be insulated up to the face of the terminal unit even if inlet adapters are used. Figure 1 - Dual Duct Recommended Hanger Bracket Locations 1/2 IOM - Dual Duct VAV Terminals 5

IOM Dual Duct VAV Terminals Section 1 - Installation Procedure FIELD WIRING All field wiring must comply with the local codes and with the National Electrical Code (ANSI/NFPA 70-1981). Electrical, control, and piping diagrams are shown on the exterior labeling or on the diagram on inside of control enclosure cover. CONTROL START-UP, OPERATION Detailed information regarding power, accessory and communications connections, start-up and operating procedures for the controls provided by TITUS are available from your local TITUS representative. For specific information on controls by other manufacturers, contact that manufacturers local branch or dealer. Important: Units with digital controllers may incorporate specific communication addresses based on Building Management Systems Architecture, and original engineering drawings. Installing the terminal in a different location than noted on unit label may result in excessive start-up labor. CALIBRATION INSTRUCTIONS For Pneumatic Controls, see PNEU-IOM: Operations Manual for Pneumatic Controls. For Analog Controls: Titus TA1, see ANA-IOM: Analog Controller Calibration. For Digital Controls: see control manufacturer s manual REPLACEMENT PARTS Description Part Number Primary Damper Assembly Size 4-5-6 31171301 Size 7 31171302 Size 8 31171303 Size 9 31171304 Size 10 31171305 Size 12 31171306 Size 14 31171307 Size 16 31171308 Damper Shaft Extension Short Stub all sizes 70300301 Long Ext. Sz. 4-6, 14, 16 70300302 Long Ext. Sz. 7-12 70300303 Shaft Bearing -All 70324901 Control Tube Red Stripe 1/4 O.D. 61510035 Green Stripe 1/4 O.D. 61510234 Red Stripe 3/8 O.D. 61510279 Green Stripe 3/8 O.D. 61510280 Yellow Stripe 1/4 O.D. 61510260 White Stripe 1/4 O.D. 61510261 Blue Stripe 1/4 O.D. 61510262 Tees for sensor taps Plastic 1/4 42150011 Plugs for tees 1/4 42160081 AeroCross TM Multipoint Velocity Sensors Size 4 3151520001 Size 5 3151520001 Size 6 3151520002 Size 7 3151520003 Size 8 3151520004 Size 9 3151520005 Size 10 3151520006 Size 12 3151520007 Size 14 3151520008 Size 16 3151520009 6 IOM - Dual Duct VAV Terminals

Notes IOM - Dual Duct VAV Terminals 7