RAI-M series RUDDER ANGLE INDICATOR SYSTEM

Similar documents
660 Multipoint Electronic Level Switch

Installation and Operation Manual

OPERATION AND INSTALLATION MANUAL

TS-202 FFU Lever Remote Part Number & Operation & Installation Instructions Version 2.1

High-performance submersible pressure transmitter For level measurement Model LH-10

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

INSTRUCTION MANUAL. January 23, 2003, Revision 0

INSTALLATION MANUAL 2001 AUTOPILOT

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

Preferred Instruments Danbury, CT USA

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

ATOC Meteorological Tower (6 meter-4 level) Guide

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

GV Standard X-Vent. Setup, Commissioning & Installation Guide

Installation, operating and maintenance Instructions for Seemag bypass level indicator

High-performance submersible pressure transmitter For level measurement Model LH-10

Constitution Instructions

OEM Manual. MODEL ½ Digit DRUM SCALE

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Sideshift SS230 Installation on a 2006 Bayliner 265SB

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MODEL GT820 OXYGEN SENSOR

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

Installation Guide, MPower Echelon Console

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL

LVU2800 Series. Ultrasonic Level Transmitter

OWNER'S MANUAL LOCK-N-LOAD BULLET FEEDER (PISTOL)

Pressure Dump Valve Service Kit for Series 2300 Units

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

Masthead Sensor Installation Guide

INTRODUCTION TO NETWORK WIND 3 MOUNTING THE UNIT 14 SELECTING THE DISPLAY MODE 5 ABBREVIATIONS AND DEFINITIONS 17

VK/VP SERIES : Sealless Vertical Pump. Assembling Instructions 2010

Spectrum AquaLight (SAL ) Color Underwater Light Owner s Manual

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

Maintenance of the Electronic ( EPC ) Pressure Controllers on GCs

1420 Autopilot System. Installation & Operation Manual

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Sensoric 4-20 ma Transmitter Board Operation Manual

Technical Bulletin. Parts and Service News. LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6

Row Marker OEM /

MAINTANCE MANUAL CNC ROTARY TABLE MODEL: DMNC-5C YUASA INTERNATIONAL.

MODEL WEIGH MODULE

I.H.S INSTALLATION INSTRUCTIONS

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

P900. P900, Datenblatt Seite 1 DESCRIPTION

QUICK START GUIDE CB-450 DATA BUOY PLATFORM

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

a division of Enviro Safety Products

Operating Instructions

Lectric Cycles Mid-Drive Electric Motor Installation

DIRECT DRIVE DIXIE DOUBLE SEAMER Model 25D

Air Differentail Pressure Switch

CLEANROOM GEL GRID CEILING SYSTEM PRODUCT DATA Division

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

icreasepro Creaser Operators Manual

BUTTERFLY VALVES Series 800

Electro-Pneumatic Converter YT-940 SERIES

RC 195 Receiver-Controller

SX150A. Features. Typical Applications. Description

Magnetic level switch type MR783 Instruction Manual

Flow Sensors & Hydrometers Specification Sheet

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Low Wind High Yields Series

SEADUCER BOATS GAS MONO COME VISIT US ON THE WEB AT

Installation, Compensation and Maintenance Instructions for. RITCHIE Compasses. Made In U.S.A

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

INSTRUCTION MANUAL COMPACT PRESS. SWITCHES SERIES PCS & PCA

RTD Temperature sensor TH11

Model PSI Compressor with 3-Gallon Air Tank 12VDC

QUALITY ALUMINUM BOAT LIFTS, INC. INSTRUCTIONS. Dominator Lake Lift

MoveRoll Conveyor Operating and Maintenance Manual

RUDDER KIT INSTRUCTIONS

Instructions for Installing and Operating Clark Reliance EA101 Series Levalarm

How To: Install a 1 Body Lift using Hockey Pucks A CFans Members Mod Project by grandmastrblastr

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

User Manual Important, read before use!

Model B Wire Wet Oxidant Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

PRO1030 Bi-Directional Assembly Replacement

Parts Manual STRIKER Striker 2840 Parts List - PN Printed in USA 03/18/08

ULTIMATE 12 RUDDER INSTALLATION INSTRUCTIONS

SPWE Series. Setup Instructions. Version 2.0

Model 130M Pneumatic Controller

QUICK START GUIDE CB-150 DATA BUOY PLATFORM

Eurostyle Terminal Blocks Focus Product Stock List

˵à Êé OPERATOR'S MANUAL. Autopilot

Model 106 DPI "Micro-switch" Installation and Operating Instructions

Cleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes.

KING-GAGE. Calibration Instruction Manual. D/P LiquiSeal Purge Control and D/P Purge Control

Wellhead Mast. Installation and Operation Guide. Nanometrics Inc. Kanata, Ontario Canada

H-DIL Hydrogen/Oxygen Sample-Draw Detector Operator s Manual

INSTALLATION AND OPERATION MANUAL 2001 AUTOPILOT

Powder Measure. Care & Usage Instructions. Instructions # Product # Revision: A

Review of. Bell B206 Replica Torque Pedals. Manufactured by OE-XAM

STEYR evo 10 E STEYR evo 10 E Compact

Variable Area Flow Meters

PX3005. Rangeable Industrial Pressure Transmitter M-5721/1018

Transcription:

RUDDER ANGLE INDICATOR SYSTEM RAI-M series SEAFIRST ENGINEERING CO 45-16, Ga Um Dong, Chang Won, Kyong Nam Korea Tel : 82 55 267 1645 Fax ; 82 55 266 1646 http://www.seafirst.co.kr

GENERAL Seafirst Rudder Angle Indicator ( RAI-M ) System consists of a Rudder Angle Sensor, Distribution Box and Rudder Angle Indicator. This system ( RAI-M) is capable of operation up to 15 Seafirst Rudder Angle Indicators in total. Figure 1 : Installation Rudder Angle Indicator : DSR-104, DSR-104P Rudder Angle Sensor : DSR-110 Distribution Box : DSR-106

RUDDER ANGLE SENSOR 1) Rudder Angle Sensor is installed in the stern of the vessel, close to tiller arm. 2) A mounting base may have to be fabricated by installer to position the rudder angle sensor properly. 3) Mount the linkage supplied with the rudder angle sensor at 90 degree from tiller arm like Figure 2. Bolt the ball joint to the tiller arm. 4) The rudder angle sensor arm is same height A as the rudder tiller arm A like Figure 2. 5) B dimension should be same like Figure 2 Figure 2 : Installation of Rudder Angle Sensor Figure 3 : Dimension of Rudder Angle Indicator If the locking screw in the rudder angle sensor arm has been loosened, or the arm removed from the rudder angle sensor, re-attached the arm and check the potentiometer centering. When the rudder is dead ahead, the electrical resistance between the black wires and the white, the black wires and the red wires should be equal. The potentiometer can also be centered mechanically be aligning the notch on the sensor shaft. See Figure2 Be careful to check the installation for any mechanical obstructions or binding of the linkage, and correct it now, before it becomes a problem. The rudder angle sensor is supplied with 5 meter of shield cable. Run the cable from the rudder angle sensor towards the distribution box, ensuring that it is protected by a hose or conduit wherever it passes through fish or cargo holds, or any other area where it could be damaged.

DISTRIBUTION BOX Remove the cover from the distribution box. Mount the box in any convenient dry location using four screws through the holes ( 4.5mm diameter). The O ring seal and cable glands are splash and drip proof when properly compressed. Make the connections to the distribution box by threading cables through the appropriate size watertight glands, then stripping the insulation and inserting the cooper wires into the terminals as shown in Table1. Twist the stranded wires tightly and insert them into the terminal socket, being careful that no strands miss the opening and touched on another wires or circuit components. Use a small screwdriver to depress the wire clamp inside the terminal socket. After each wires has been connected, tighten the cable glands. Figure 4 : Dimension of Distribution box

DISTRIBUTION BOX Table 1 : Distribution box connection table : Terminal # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PCB label + VE -VE - VE PWR POSN COM N.C + M1 -M1 + M2 -M2 + M3 -M3 + 20mV -20mV N.C Wire Positive ( 8VDC to 36VDC) Negative Group ( 8VDC to 36VDC) No connection Rudder Angle Sensor White wire ( +5 Volt Power ) Rudder Angle Sensor Black wire ( Wiper Position ) Rudder Angle Sensor Red wire (Common Ground) No Connection Indicator Group 1 ( positive/signal ) Indicator Group 1 ( Negative/return ) Indicator Group 2 ( positive/signal ) Indicator Group 2 ( Negative/return ) Indicator Group 3 ( positive/signal ) Indicator Group 3 ( Negative/return ) 20millivolts per degree output (positive) 20millivolts per degree output (return) No connection Figure 5 : Example of Wiring.

Rudder Angle Indicator DSR 104 indicator by itself can be mounted simply by drilling 86mm hole and securing with supplied mounted bracket. DSR-104P indicator is supplied with SS plate. Bolt on 4 holes on the plate. Figure 6 : DSR-104 Figure 7 : DSR-104P Up to 15 Rudder Angle Indicators can be wired to the three sets of terminals in the distribution box labeled +M1/-M1, +M2/-M2 and +M3/-M3 but with a few minor restrictions : At least one rudder angle indicator must be connected to the terminal +M1/-M1 To connect an indicator to M3, M2 terminal must have an equal number of indicators as M3. No more than 5 rudder angle indicators can be connected in series. For example For one indicator installation, connect the indicator to M1. For two indicators installation, connect the indicator to M1 and M2 each. For three indicators installation, connect the indicator to M1, M2 and M3 each. For four indicators installation, connect two indicators in series to M1. One indicator to M2 and one indicator to M3. For five indicators installation, connect three indicators in series to M1. One indicator to M2 and one indicator to M3. For ten indicators installation, connect four indicators in series to M1. three indicator in series to M2 and three indicators in series to M3. Figure 7 : How to make a connection in series

TESTING After wiring the rudder angle sensor, Rudder Angle Indicators and power supply and then checking that all wiring conforms to what is shown in Table 1, switch on the master switch or breaker supplying power to the rudder angle indicator system. Move the rudder to determine if the rudder angle indicators move in the correct direction. 1) If all rudder angle indicators move the wrong direction, reverse the white and red wires coming from the rudder angle sensor to the distribution box terminals. 2) If one group ( M1, M2 or M3) of indicators goes in the wrong direction, reverse the wires going to that group s respective terminals in the distribution box. 3) If any one Rudder Angle Indicator is going the wrong direction, reverse the wires going to the indicator s own terminals. 4) If any Rudder Angle Indicator differ in readings, check the connection rules given previously. Rudder angle indicator of the same type and wired in series should agree to within three degrees as verified from the factory final tests. ADJUSTMENTS : Move the rudder to the dead ahead position. If the deal ahead is precisely known and the Rudder Angle Indicator is off, adjust the length of linkage by rotating the ball joints on the both ends of the linkage. Move the rudder to hard over port and starboard and check the indication is as expected. Two factory pre-calibrated trim controls are provided on the distribution circuit board The offset control allows some adjustment of the dead ahead rudder indication, making it easier to adjust the system while on sea trials. If the indication is more than 10 degree off, adjust the rudder angle sensor linkage rather than the offset trim control. The span control allows some adjustment of the Rudder Angle Indicator indication at the hard over rudder position. This system is calibrated at the factory to be accurated within 3 degree if installed as per instruction. If the Rudder Angle Sensor linkage geometry is not correct ( rudder tiller arm and rudder angle sensor arm are not equal in height, parallel or linkage rod is not 90 degrees when centered), indication of the hard over positions will be off. It is better to correct the linkage but, if this is not possible, the span control can be used. Making a large correction for the linkage problem by using the span control can introduce errors in indication at the half deflection position and unequal indication at the hard over position.