Residential Meters. Available innov8 Outputs 900 MHz Radio Virtual Network 3W Standard AMR 2W AMR 2W Standard Touchpad Scalable Pulse 4-20mA SCADA

Similar documents
Applications. Features AWWA ULTRASONIC WATER METER

500 Series IIS Magnetic Drive Positive Displacement Disc Meters Sizes 1-1/2 & 2

Flow Sensors & Hydrometers Specification Sheet

WATER METERS.

Residential Pressure Booster Systems

TECHNICAL ACCESSORIES

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

SonoSelect 10 and SonoSafe 10 energy meters

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Level MEASUREMENT 1/2016

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

SonoMeter 30 Energy Meters

Ultrasonic level transmitter and indicator

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

SINGLE VALVE WITH LOW-FLOW BYPASS

C Lite CAD SERIES. ACS Approved. Patented CAD-2 diaphragm technology. Rugged copolymer polypropylene base. Quality brass air stem with o-ring seal

LUGB Vortex Flowmeter

DS06D,G Dial Set Pressure Regulating Valve

Float Operated Level Controllers

CALEFFI. Reduced pressure zone backflow preventer. 574 series 01022/18 NA D E C F B D E. Function

Expert Hydrostatic Level Transmitters

TECHNICAL DATA. Page 1 of 12

RESIDENTIAL REGULATORS

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Variable Area Flow Meters

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

CAST IRON VALVES FLOAT VALVE

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pneumatic dead-weight tester Model CPB3500

Drum-Type Gas Meters Series TG (Wet-Test)

Vehicle- or rack-mounted liquefied gas meters, pump supplied

Commercial and Industrial Aluminumcase Diaphragm Meters Capacity Ratings from 800 scfh to 5000 scfh

Liquid Level Controllers

ROYTRONIC EXCEL TM Series AD Electronic Metering Pumps

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

TECHNICAL DATA NOTICE

FIREFIGHTING EQUIPMENT

B L A C K H A L L. larner-johnsonvalve presentation

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Laboratory Flowmeters

Geotech 1.66 Reclaimer

FIREFIGHTING EQUIPMENT

TECHNICAL DATA CAUTION

the strength behind the products you trust

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

Type 4708 Supply Pressure Regulator

COMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist

TECHNICAL DATA. Q = C v P S

Section GAS CHLORINATION SYSTEM

TECHNICAL DATA. Q = C v P S

Pressure Regulators Pressure regulation to maximize steam system efficiency

VACUUM REGULATORS CONTENTS

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

HORIZONTAL BLADDER TANK

pren CEN standard-draft pr EN 12261

T EK-COR 1100A Coriolis Mass Flowmeter

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

Geotech 3.5 Reclaimer Installation and Operation Manual

INDOOR CYCLING. FREEMOTION FITNESS toll free or [+1] INDOOR CYCLING FreeMotion Fitness

CASH VALVE TYPE KP BACK PRESSURE VALVES

Water Pressure Reducing Valves

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA Q= C. Table 1 - Specifications

C-Flow Coriolis Mass Flow Meters

Pressure Regulating Valves. Models 44, 77 & 68 PS\ UL. Pressure Relief Valve. Dorot Fire Protection Division. Certification & compliance by design

Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO

my SYSTEM A guide to common applications in water distribution systems

Make sure it s a Magnetrol

Geotech 1.66 Reclaimer Installation and Operation Manual

Reasons of Domestic Gas Meter Failures

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

DAV - P. Product Catalogue DAV - P. Air release & Vacuum Break Valves. (Plastic Air Valves) DAV - P. Edition 2012

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

Type 4708 Supply Pressure Regulator

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

VERTICAL BLADDER TANK

Specification For Water Meters. Pr10068

3M Electrial Markets Division EMS. Electronic Marker System

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

THERM-O-MIX STATION/WWM TEMPERED WATER SUPPLY

MES Flowmeter Sizes - Specifications. ManuFlo (c) Manu Electronics 2015

INDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS

Aquavar SOLO 2 Frequently Asked Questions

Electro-Magnetic Flowmeters Electromagnetic Sensor

Turbine Flowmeters for Liquid Applications

MODEL UM UNIVERSAL MANIFOLD ASSEMBLY (With or Without Control Valve) 1¼", 1½", 2", 2½", 76.1mm, 3", 4", 6",165.1mm, 8"

shutoff valves 900 Series psig Manual Shutoff Valves

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Hydraulic pressure balance Model CPB5800

LARGE R/W GATE VALVES

Transcription:

The Spectrum Single-Jet Meter is the widest range, single measuring element meter available to U.S. utilities. They have been designed to replace limited range displacement and multi-jet meters. The Spectrum meters can accurately measure much lower flow rates than modern displacement meters of comparable size. The Spectrum models 15D, 25D, 30D, S30DB and S30DL are a single-element meter which utilizes the innov8 electronic register. A composite (reinforced plastic) and lead-free bronze models are available. This combination of design simplicity, superior grade materials, and high quality manufacturing standards allows for years of virtually new meter performance with no maintenance. Residential Spectrum features include: High accuracy exceeding high and low range of AWWA residential standards Starting flow below 1/16 gpm Single moving element No maintenance Excellent performance in adverse water conditions Unaffected by sand or small debris in line No straight pipe requirements upstream or downstream of meter High resistance to freezing Lightweight, compact design for simple installations No strainer requirement Utilizes the innov8 electronic register 10-year materials and workmanship warranty 10-year AWWA New Meter Accuracy Guarantee Environmental Specifications Fluids measured Potable cold and reclaim water Flow Range See Table 1. Accuracy ± 1.5% See Figure 1. Repeatability 0.5 % of flowrate Pressure Loss See Figure 1. Max Operating Pressure 230 PSI Max Operating Temperature 140 F (60 C) Residential Meters Physical Specifications Model MP-5 Composite Body Reinforced Nylon (Polyamide 12) Bronze Body - EcoBrass Impeller Polypropylene Impeller Shaft Tungsten Carbide Impeller Bearing Nivaflex Impeller Pivots Sapphire End Connections NPSM Threads Dimensions Compliant with AWWA residential standards - See Table 2 Weight 1.0 lb (0.45kg) Available innov8 Outputs 900 MHz Radio Virtual Network 3W Standard AMR 2W AMR 2W Standard Touchpad Scalable Pulse 4-20mA SCADA Applicable Standards AWWA C712-15 NSF-61/372 (Composite) 1 Residential Spectrum Rev 4.0 Dec2015 Specifications subject to change

Operation Incoming water rotates a suspended impeller with an embedded magnet on the top. The offset impeller allows the meter to pass sand and other particulates through the measuring chamber with no effect. Installation To maintain accuracy, the Spectrum meters should be installed horizontally (±10 ) in the direction of water flow, with the register face up. In most applications, no straight pipe length, upstream or downstream is necessary. Under normal usage conditions the Spectrum meter is not affected by sand or suspended particles and does not require a strainer. The Spectrum meter body has a hexagonal shape for a wrench to be used during installation. A low friction sapphire pivot bearing supports the floating impeller at low flow rates while a thrust bearing provides the support at high flow rates. This patented dual bearing design provides unparalleled accuracy and durability at both high and low flows. @ low flow @ high flow Design & Materials The composite body is made of a material with additives chosen for high strength, toughness, dimensional stability, and full compliance with no lead standards (NSF 61 / annex G). The bronze body is made from a proven lead-free material, Ecobrass. Threads The NPSM threads of the Spectrum meters have been tested in comparison to typical brass meter threads. The reinforced composite material is comparable in tensile strength and has improved hardness over common leaded and unleaded brass alloys. Thanks to a unique design, the meter withstands higher water pressures (over 1000 PSI) than most other residential meters. The residential Spectrum meters can withstand freezing and the measuring chamber is protected from impacts, UV radiations or other external disturbances. Detailed reference sheets for meter installation can be provided by Metron-Farnier upon request. 2

Accuracy Testing For optimal performance during meter accuracy tests observe the following: Register is level to the horizontal Upstream pipe should be the same diameter or larger than meter connection Upstream valve should be fully opened during test, use downstream valve to regulate flow rates Inspect for leaks between the Spectrum and downstream volumetric tank or reference meter Time low flow test to confirm accuracy of flowrate indicator The innov8 register has a test mode for accuracy tests. This mode automatically sets the LCD display for higher display resolution and isolates the test volumes from the customer total. Detailed reference sheets for meter testing can be provided by Metron-Farnier upon request. The next revision of the AWWA M6 manual will include testing methods and recommendations for single-jet meters. Register The Spectrum 30D water meter uses the innov8 electronic register. The innov8 register utilizes a magnetic sensor to track the impeller rotation and exerts no drag on the measurement. This ensures the optimum meter accuracy. Tamper-Proof Features The Spectrum meters employ a tamper-resistant and tamper-evident register housing. The innov8 register is fixed to the meter body with a plastic housing and a tamper-proof screw. Installers can obtain the special tamperproof bits from their Metron representative. Unauthorized removal will break the snap ring and indicate tampering. The Spectrum 30D has an interference ring to protect the sensor from external magnetic fields. The innov8 register is a replaceable register with tamperproof features. Consult Metron for innov8 technical and installation information. Available Outputs The innov8 electronic register can be utilized within virtually any AMR/AMI system. The innov8 employs defacto communication standards for 2-wire (touchpad), 3-wire (radio) interfaces and a scalable pulse. The innov8 will also have options for embedded M2w 900 MHz datalogging radios with either integral or remote antennas. 3

Reference the innov8 technical specifications and AMR application notes for more information. Flow Specifications Table 1 4

Accuracy Curves S15D Pressure Drop Curves S15D S25D S25D S30D / S30DB / S30DL S30D / S30DB / S30DL 5

Meter Dimensions Spectrum 15D 5/8 Short Spectrum 25D - 5/8 6

Spectrum 30D and 30DB 5/8 x ¾ Spectrum 30DL ¾ 7

Register Information Innov8 Default Residential Configuration Meter Identification Each Spectrum meter will have a unique serial number laser etched into the meter body. Attached innov8 registers will also have an identification number engraved into the top lid. Consult your Metron representative for more information. 8