GAS DELIVERY PRESSURE AND MEASUREMENT

Similar documents
SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING Reserved

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING

1800CPB2 Pilot-Loaded Service Regulators

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

Your safety and the safety of others are very important.

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

Residential and Small Commercial

1800CPB2 Service Regulators

Installation Instructions

I. Subject: Compressed gas cylinders, regulators, and portable liquid systems.

GAS SUPPLY APPLICATION GUIDE

Overview EUSDSG3.6. Gas tightness testing and direct purging

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

ACCESSORY KIT INSTALLATION INSTRUCTIONS

KC Series Gas Components and Supply Design Guide

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Committee Input No. 59-NFPA [ Section No. 5.9 ]

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators

Noth American 7347 High Pressure Gas Regulators

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

WARNING: FOR OUTDOOR USE ONLY

MEGR-1912 Instruction Manual

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

Pressure Regulators. Operating Instructions. Instrumentation

Overview EUSSAM12. Carry out tightness testing and direct purging of gas installations

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

INSTALLATION & OPERATION MANUAL FOR Stockpot Range

Certified LP/Propane Line Pressure Regulator Guidebook

LINE PRESSURE REGULATOR GUIDEBOOK 7TH EDITION

September 2018 Pressure Test

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

627 Series Pressure Reducing Regulators

GAS SUPPLY DESIGN GUIDE

Types 749B and R130 Changeover Manifolds

1805 Series Relief Valves

/2004 US/CA

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

MEGR-1627 Instruction Manual

What is pressure relief valve? Pressure relief valve

1805 Series Relief Valves

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

OPERATING INSTRUCTIONS

Thank You for Attending Today s Webinar. Today s Featured Speaker

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT. Number: 2015 IFC Effective Date: February 1, 2017 Page 1 of 5

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Principle of Operation. Features. Applications. CL34 Operating Schematic

Type 299 Pressure Reducing Regulators

RE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE

First Stage Regulators

ACCESSORY KIT INSTALLATION INSTRUCTIONS

LNG Regulator Test Kit

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

Service Regulator Requirements

Installation Instructions For Natural Gas Conversion

TOTAL CAPABILITIES IN THE PIPELINE INDUSTRY. UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson

ACCESSORY KIT INSTALLATION MANUAL

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Installation Instructions For Propane Gas Conversion (Kit Part No ) This kit is designed for conversion to Propane Gas

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

v. Size shall be specified on drawings.

Types S100K and S102K Pressure Regulators

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators

64 Series Pressure Reducing Regulators

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

Commercial and Industrial Aluminumcase Diaphragm Meters Capacity Ratings from 800 scfh to 5000 scfh

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS

New Hampshire Public Utilities Commission CFR 49 Part 192 Regulations. MINIMUM Pipeline Safety Regulations

B34 Series Regulator Commercial and Industrial Regulator

TOTAL CAPABILITIES IN THE PIPELINE INDUSTRY. UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson

G REQUIREMENTS FOR THE INSTALLATION OF GAS BOOSTERS, MICROTURBINES AND ASSOCIATED SYSTEM PROTECTIVE DEVICES

DESIGN AND INSTALLATION GUIDE

299H Series Pressure Reducing Regulators

Natural Gas to L.P. Gas Conversion Kit

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

1 Exam Prep. Tabs and Highlights

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

High-Pressure Boiler Inspection Procedures: A Complete Checklist

S300 Series. Valve Link. Features. Fisher Controls

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Page 1 of 18 Gastite Quiz Part 2

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

Natural Gas to L.P. Gas Conversion Kit

INSTALLATION & OPERATION MANUAL FOR Teppan-Yaki Griddles

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

Standard Pneumatic Test Procedure Requirements for Piping Systems

1800C and 1800C-HC Service Regulators

Overview EUSDSG3.12. Install gas meters and regulators (2.5 to 16.0m3/hr)

INTERLOCKED METAL HOSE

MEDICAL EQUIPMENT CATALOG

Transcription:

GAS DELIVERY PRESSURE AND MEASUREMENT I. PURPOSE: To establish a uniform basis on which to provide gas measurement and pressure regulation facilities on customers premises. II. DELIVERY PRESSURES AND PROVISIONS: The measurement base for billing purposes is six (6) inches w.c. pressure at the meter outlet. Elevated regulated pressures, if provided, will be supplied at two (2) pounds, five (5) pounds or at unregulated intermediate line pressures (i.e., at the same pressure as the distribution main serving a given meter setting). Any deviation from the delivery pressures listed above shall be approved by the Director of Engineering and Gas Supply or, in their absence, the Superintendent of Gas Operations Services. A. Gas Pressure Regulators. A gas pressure regulator or gas equipment pressure regulator shall be installed where the gas appliance is designed to operate at a lower pressure than the fuel gas system. Access shall be provided to pressure regulators. Pressure regulators shall be protected from physical damage. Regulators installed on the exterior of the building shall be approved for outdoor installation (IMC Sec. 1307.1, IRC Sec. G2420.1). * Gas pressure regulators that require a vent shall have an independent vent to the outside of the building (IMC Sec. 1307.4, IRC G2420.3) B. Equipment Shutoff Valve. Every gas outlet shall have an individual shutoff valve. The shutoff valve shall be in the same room and within 6 feet of the appliance served. Access shall be provided to the shutoff valve (IMC Sec. 1305.1). For multiple lines, follow procedures outlined in IMC 1305.2. Each appliance shall be provided with a shutoff valve separate from the appliance. The shutoff valve shall be located in the same room as the appliance, not further than 6 feet form the appliance, and shall be installed upstream from the union, connector or quick disconnect device it serves. Such shutoff valves shall be provided with ready access (IRC Sec. G2419.5).

C. Piping Materials. Piping materials and specifications shall be in accordance with the IMC Sec. 1303 and IRC Sec. G2413. Corrugated Stainless Steel Tubing (CSST) systems shall be tested, listed and installed in compliance ANSI/AGA LC 1 (IMC Sec. 1303.3, IRC Sec. G2413.5.3). CSST may be used for pressures up to 5 psig. D. Identification. For other than black steel pipe, exposed piping shall be identified by a yellow label marked Gas in black letters. The marking shall be spaced at intervals not exceeding 5 feet. The marking shall not be required on pipe located in the same room as the equipment served (IMC Sec. 1301.5, IRC Sec.G2411.5). All tubing carrying medium-pressure gas shall be marked with a label at the beginning and end of each tubing section (IMC Sec. 1301.5). E. Maximum Design Operating Pressure. The maximum design operating pressure for piping systems located inside buildings shall not exceed 5 psig except where one or more of the following conditions are met: 1. The piping system is welded (IRC Sec. G2412.5; welded steel pipe IMC Sec. 1306.5). 2. The piping is located in a ventilated chase or otherwise enclosed for protection against accidental gas accumulation (IRC Sec. G2412.5). 3. The piping is a temporary installation for buildings under construction (IRC Sec. G2412.5). 4. The piping is located inside buildings or separate areas of buildings used exclusively for (IMC Sec. 1306.5): 4.1 Industrial processing or heating, 4.2 Research, 4.3 Warehousing, or 4.4 Boiler or mechanical equipment rooms. However, Citizens Gas & Coke Utility recommends (but does not require) all elevated pressure lines 2 ½ " or larger be of welded construction. III. PIPE SIZING PRACTICES: A. General Considerations. Piping systems shall be of such size and so installed as to provide a supply of gas sufficient to meet the maximum demand without undue loss of pressure between the point of delivery and the gas utilization equipment (IRC Sec. G2412.1). All pipe utilized for the installation, extension and alteration of any gas piping system shall be sized to supply the full number of outlets for the intended purpose (IMC Sec. 1302.1).

B. Maximum Gas Demand. The volume of gas to be provided in ft 3 per hour shall be determined directly from the manufacturers input ratings of the gas utilization equipment served. Where input rating are not indicated, the gas supplier, equipment manufacturer, or an approved agency shall be contacted for estimating the volume of gas to be supplied (IRC Sec. G2412.2). The total connected hourly load shall be used as the basis for piping sizing assuming that all equipment could be operating at full capacity simultaneously (IRC Sec. G2412.2). The hourly volume of gas demand at each outlet shall not be less than the maximum hourly demand, as specified by the manufacturer of the appliance served (IMC Sec. 1302.2). C. Allowable Design Operating Pressure. The design pressure loss in any piping system under maximum probable flow conditions, from the point of delivery to the inlet connection of the equipment, shall be such that the supply pressure at the equipment is greater than the minimum pressure required for proper equipment operation (IRC Sec. G2412.4). Piping sizes shall be determined by the use of approved accurate gas flow, computer or pressure drop charts. The maximum pressure drop for point of delivery to any appliance shall not exceed 0.5 inch of water column (IMC Sec. 1302.8) D. Sizing. Gas piping shall be sized in accordance with IMC Sections 1302.5, 1302.6, 1302.7, 1302.8 and IRC Sec. G2412.3 Tables 1 through 6 or other approved engineering methods. IV. METERING PRACTICES: A. Overpressure Protection. Overpressure protection devices shall be provided to prevent the pressure in the piping system from exceeding that value that would cause unsafe operation of any connected and properly adjusted gas utilization equipment. Each pressure limiting or pressure relieving device shall be set so that the pressure shall not exceed a safe level beyond the maximum allowable working pressure for the piping and appliances connected. B. Temperature Compensation. Temperature compensation shall be applied to all loads. All settings metered at line pressure, shall include a correcting device for temperature, pressure, and supercompressibility. C. Pressure Correction. Pressure correction for billing purposes shall be in accordance with General Instruction #80, Standard Unit of Volume for

Gas Measurement (see attached Pressure Factor Table). Intermediate or higher line pressure delivery shall be corrected to base conditions by suitable instrumentation. D. Meter setting design shall be the responsibility of the Engineering Standards & Measurement Section. V. EXCEPTIONS: A. Exceptions to the elevated delivery pressures may be approved by the Director of Engineering and Gas Supply with the following submitted in advance: 1. Plans for the installation. 2. Equipment specifications. 3. Other necessary information. * IMC = International Mechanical Code IRC = International Residential Code

ATTACHMENT A PRESSURE FACTOR TABLE (Includes Supercompressibility) Metering Pressure Factor 6 1.000 7 1.002 8 1.005 9 1.007 10 1.010 11 1.012 12 1.015.5# 1.019 1# 1.054 2# 1.123 3# 1.192 4# 1.261 5# 1.330 6# 1.399 7# 1.468 8# 1.537 9# 1.606 10# 1.675 11# 1.744 12# 1.813 13# 1.882 14# 1.952 15# 2.021 Consult Engineering Standards & Measurement Section for Pressure Factors higher than those listed.