General Specifications

Similar documents
General Specifications

General Specifications

General Specifications

Chapter 22 Testing Protocols

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

TABLE OF CONTENTS LIST OF FIGURES

ProSoft Technology, Inc. Summary Regarding Alberta Energy and Utilities Board Directive 017 of May 2007

Flow Vision I MX Gas Blending Station

ISO INTERNATIONAL STANDARD

Gas Measurement Fundamentals Certification. Curriculum

Injection Controller Program User Manual (for FloBoss 107 and ROC800-Series)

ISO INTERNATIONAL STANDARD. Natural gas Calculation of compression factor Part 2: Calculation using molar-composition analysis

ERZ 2000-NG Flow Computer

Discovery HP-TGA 75/750. Site Preparation Guide

Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA

Gas Billing Factors Guideline

vj.i GUIDELINES --.- PETROLEUM (EXPLORATION & PRODUCTION) (MEASUREMENT) REGULATIONS, 2016 (L.I. 2246)

1 PIPESYS Application

* William A. Sala, Jr. John A. Roscher. Columbia Gas Transmission, LLC * Sorana Linder 700 Louisiana Street, Suite 700 Director, Regulated Services

Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter

Features. Description

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

Agilent 490 Micro GC Natural Gas Analyzer

Operational Settings:

GAS CONTRACTS MEASUREMENT LANGUAGE AND ITS EVOLUTION. Lohit Datta-Barua, Ph. D. Enterprise Products

analytical bulk flow distance FLOW level pressure temperature industrial communication

Yokogawa Systems and PCI Training

ISO INTERNATIONAL STANDARD. Flow-metering devices for connection to terminal units of medical gas pipeline systems

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources

Vehicle- or rack-mounted liquefied gas meters, pump supplied

Excellent Vortex Flowmeter INSERTION Type BATTERY POWERED EX DELTA

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

ISO 2503 INTERNATIONAL STANDARD

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Bubble Tube Installations

Technical Bulletin, Communicating with Gas Chromatographs

Discovery TGA 55, TGA 550, TGA Site Preparation Guide

molbox1+ Flow Terminal ± % of reading lowest uncertainty for gas flow calibration

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

Technical Data Sheet MF010-O-LC

ISO 6570 INTERNATIONAL STANDARD. Natural gas Determination of potential hydrocarbon liquid content Gravimetric methods

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

HEALTH AND SAFETY PROGRAM 201 HOT TAP PERMIT/FILLET WELD REPAIRS

PMI Pulse Decay Permeameter for Shale Rock Characterization Yang Yu, Scientist Porous Materials Inc., 20 Dutch Mill Road, Ithaca NY 14850

CAMASS. Calibration Centre. Gas flow technology and services

Automatically or individually calculated.

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Norval Pressure regulator

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

Slam Shut Valves SCN

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

ISO INTERNATIONAL STANDARD. Welding consumables Gases and gas mixtures for fusion welding and allied processes

ISO INTERNATIONAL STANDARD

UNIT 10 - GASES. Notes & Worksheets - Honors

780S Ultra High Purity Series

Chemistry 51 Chapter 7 PROPERTIES OF GASES. Gases are the least dense and most mobile of the three phases of matter.

Thermal flow sensor TA Di with integrated transducer for measuring mass flow, standard flow rate and air / gas consumption

The University of Hong Kong Department of Physics Experimental Physics Laboratory

Micro Motion Advanced Phase Measurement

Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

CAMASS. Calibration Centre. Gas flow technology and services

Measurement & Analytics Wet gas monitoring

Standard Operating Manual

Part 6: Critical flow orifices

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

Dräger X-dock Frequently Asked Questions

Ultra High Purity Model 780S

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Differential Pressure Level Solutions. Bulletin 01C25A04-01EN-Y

Mass Flow Controller (MFC) for Gases

Discovery SDT 650. Site Preparation Guide. Revision G Issued December Page 1

MATHESON s LaserPro Gases and Gas Delivery Equipment

Mass Flow Meter (MFM) for Gases

AGW SYSTEMS. Blue Clock W38X

Improved Reliability in Natural Gas Energy Measurement with the Revised ISO Standard. Gerard Nieuwenkamp - VSL

Instrument Performance Evaluation, comparing ISO and NORSOK I-106 Dr Paul Holland, EffecTech Group & Jon Carlsen, Norsk Analyse North Sea Flow

Calibrating and Monitoring MUSMs in Natural Gas Service

ASX 176 Axial Pressure regulator

Products Solutions Services. Gas Flow Measurement

Meter Data Distribution User Manual

Gas Mass Flow Meter SUS/SUS316

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Example: 25 C = ( ) K = 298 K. Pressure Symbol: p Units: force per area 1Pa (Pascal) = 1 N/m 2

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ISO INTERNATIONAL STANDARD

Field Instrumentation Training Strategy

Oracle Utilities Meter Data Management Release Utility Reference Model MDM.Manage VEE and VEE Exceptions

The ERCB Directive 017 Overview

1805 Series Relief Valves

ISO INTERNATIONAL STANDARD. Transportable gas cylinders Inspection and maintenance of cylinder valves

Totalflow Web Interface (TWI) software Help notes v1.0 Oct. 3, 2014

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

ISO 9539 INTERNATIONAL STANDARD. Gas welding equipment Materials for equipment used in gas welding, cutting and allied processes

VERIFYING GAS CHROMATOGRAPH OPERATION AT CUSTODY TRANSFER LOCATIONS Murray Fraser Daniel Measurement & Control

ISO INTERNATIONAL STANDARD. Cryogenic vessels Pressure-relief accessories for cryogenic service Part 1: Reclosable pressure-relief valves

Technical Information

Transcription:

General Specifications Gas Flow Calculation Portfolio GS 34P02P31-01E GENERAL This general specification document describes the Gas Flow Calculation Portfolio on FCN/FCJ autonomous controllers. Using this portfolio, gas flow rate is calculated on robust and hazardous certified STARDOM controllers FCN/FCJ while control logics are running. FEATURES High Speed and Volume Calculation 32bit high speed processor achieves a number of flow meter runs for many gas wells and responds to quick change of gas composition. Control with Flow Calculation Control logics, programmed with IEC 61131-3, run with gas flow calculation. Regulatory control function blocks NPAS based on Yokogawa DCS expertise are adaptable for gas flow control such as valve control. (*1) Parameter Setting Window Parameter Setting Window is prepared for easier parameters setting. Via OPC server, parameters can be set to SCADA as well. Meet the requirement of API21.1 Gas Flow Calculation Portfolio meets the requirement of API21.1. *1: To use NPAS function blocks, PAS portfolio license is required. Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5616 URL: http://www.stardom.biz GS 34P02P31-01E Copyright Apr. 2008(YK) 6th Edition Aug. 9, 2012(YK)

2 PORTFOLIO COMPONENTS Gas flow calculation portfolio consists of several components. Gas Flow Calculation POU Gas flow calculation POU calculates the gas flow rate and provides the functions meeting to the API21.1 requirement. Gas flow calculation Averaging Data Hourly and Daily Quantity Record Creation Configuration Log Generation Parameter Setting Window can be set to POU and the calculated gas flows are monitored on Web-based parameter setting windows. Those windows do not require any PC based software apart from a web browser. (*1) Logging Logging Portfolio logs the quantity transaction record created by Gas Flow Calculation POU (*2) and alarms and messages. SCADA Parameter Setting Window COTS PC Logging Offline Report file read Report and Event Parameter Set Read Record OPC DA Communication Parameter Set Read Record HTTP Online Report file read Automatic File Transfer Tool Process Data FCN/FCJ Gas Composition Valve Control Gas Flow Calculation POU IEC Application Process Data Quantity Transaction Record Logging Report and Event Pressure Transmitter Gas Chromatography Valve Gas Flow Calculation POU F01E.ai *1: Parameter Setting Windows are included in Application Portfolio Software Media. FCN/FCJ Basic Software License for Single CPU with Java function is required to use parameter setting windows. Parameter Setting Windows use InfoWell technologies. If modification of the parameter setting windows is required, Web Application Portfolio License (InfoWell) is required. TI34P03A51-01E (Gas Flow Calculation Portfolio) describes the modification methods. *2: Logging Portfolio is included in Application Portfolio Software Media. Logging Portfolio license is bundled with Gas Flow Calculation Portfolio. FCN/FCJ Basic Software License for Single CPU with Java function is required to use Logging Portfolio. All Rights Reserved. Copyright 2008, Yokogawa Electric Corporation GS 34P02P31-01E Dec. 25, 2008-00

3 GAS FLOW CALCULATION POU Gas flow calculation POU calculates the gas flow and creates the quantity transaction record. Gas Flow Calculation Gas flow calculation POU calculates gas flow following AGA publication. Table Supported Gas Calculation Report Number Title Remark AGA Report No. 3 Orifice Metering of Natural Gas Part 3: Natural Gas Applications (1992) AGA Report No. 7 Measurement of Natural Gas by Turbine Meters (1996) AGA Report No. 8 Compressibility Factor of Natural Gas and Related Hydrocarbon Gases (1992) AGA Report No. 9 Measurement of Gas by Multipath Ultrasonic Meters (2007) Pulse input only AGA Report No. 10 Speed of Sound in Natural Gas and Other Related Hydrocarbon Gases (2003) AGA Report No. 11 GPA 2172 V-Cone V-Cone (2006) Measurement of Natural Gas by Coriolis Meter Calculation of Gross Heating Value, Relative Density and Compressibility Factor for Natural Gas Mixtures from Compositional Analysis (1996) Averaging Data The following two averaging method are supported. Flow-dependent time-weighted linear average (*1) Flow weighted linear average *1: Average is calculated using production time. Hourly and Daily Quantity Transaction Record Creation Gas flow calculation POUs calculate the following value Table Calculated quantity record Time Category Calculated Value Today, yesterday, current hour, previous hour Average Total Current month Total Total flow Dry only Static pressure, differential pressure, temperature, flow rate, mass flow rate, energy Total flow, total mass, total uncorrected flow, total energy, total flow time, total shutin time, total pulse Configuration Log When the configuration parameters are changed, Gas Flow Calculation POUs notify the configuration change by setting the configuration flag ON. Generation Process HH/LL/HI/LO messages are generated when process input (Static Pressure, Differential Pressure and Temperature) exceeds the specified limitations. Scan Period of Task and Maximum POU number Item Scan Period of Task Table Scan Period of Task and Maximum POU number Specification Limited to 1 second when using Gas Flow Calculation POU Maximum POU number 12 POUs for FCN and FCJ, 8 POUs for FCN-RTU when using logging portfolio (*1) *1: The metering numbers are depending on the total CPU performance. All Rights Reserved. Copyright 2008, Yokogawa Electric Corporation GS 34P02P31-01E Aug. 9, 2012-00

4 PARAMETERS SETTING AND MONITORING WINDOW The following parameters can be set on Web-based windows. Table Setting (1/2) Common Flow Conditions Base Conditions Heating Value Compressibility Gas Composition Orifice V-Cone Meter name Contract hour Meter type Unit Unit Switch Static pressure Atmospheric pressure Base temperature Base pressure Heating Value calculation method Compressibility Gas composition input Normalize Gas composition Relative density Gross heating value for gross heating value for relative density Reference pressure for relative density for molar density Reference pressure for molar density Differential pressure cutoff Orifice Plate Pipe Tap location Correction factor Differential pressure cutoff V-Cone Pipe Correction Factor Meter identifier (Meter Name) Report file closing time Orifice / Turbine / Ultrasonic (Pulse input only) /Coriolis US / SI unit Switch changing unit volume Absolute / Gauge Calculated / Manual Atmospheric pressure is calculated based on Latitude and Altitude in case of Calculated. Base temperature Base pressure Manual / GPA 2172 Heating value is calculated on condition that base temperature is equal 60degF in case of GPA2172. AGA 8 Detail Characterization Method / Gross Characterization Method 1 / Gross Characterization Method 2 Manual / Live Gas composition is set manually in case of Manual. Gas composition is set to POU inputs in case of Live. Yes / No Each gas composition is normalized if total mole fraction is not equal to 1 in case of Yes. Nitrogen, Carbon dioxide, Hydrogen sulfide, Methane, Ethane, Propane, i_butane, n_ Butane, i_pentane, n_pentane, n_hexane, n_heptane, n_octane, n_nonane, n_decane, Water, Oxygen, Carbon monoxide, Helium, Argon Calculated / Fixed Relative density calculated based on the gas composition incase of Calculated. Relative density can be set manually in case of Fixed. Gross heating value can be set manually. Gross method reference temperature for gross heating value Gross method reference temperature for relative density Gross method reference pressure for relative density Gross method reference temperature for molar density Gross method reference pressure for molar density Differential pressure cutoff Bore diameter, material Internal diameter, material for plate and pipe Upstream / Downstream Flow rate correction factor Differential pressure cutoff V-Cone diameter, material Pipe internal diameter, material Flow rate correction factor All Rights Reserved. Copyright 2008, Yokogawa Electric Corporation GS 34P02P31-01E Jun. 3, 2010-00

5 Table Setting (2/2) Turbine Ultrasonic Coriolis Calculation condition Average Maintenance K-Factor Pulse Cutoff K-Factor Pulse Cutoff K-Factor Pulse Cutoff Deadband Average method Mode Pulse K-Factor Pulse cutoff Pulse K-Factor Pulse cutoff Pulse K-Factor Pulse cutoff Gas flow is calculated when process input exceeds the specified deadband. Deadband of static pressure, differential pressure and temperature deadband can be specified. HH/HI/LL/LO limits of static pressure, differential pressure and temperature can be specified. s are generated when process inputs exceed limits. Flow-dependent time-weighted linear / Flow-weighted linear Average method can be selected for static pressure, differential pressure, temperature and pulse count. The specified data is used instead of process data when maintenance mode is set. Maintenance mode of static pressure, differential pressure and temperature can be set. Table Monitoring Current data Average Total Time Process input Calculation status Calculated data Data item Time span Data item Time span Data item Time span Static pressure, differential pressure and temperature Calculation status Flow rate, raw flow rate (uncorrected flow), mass flow rate(coriolis only) energy, compressibility, compressibility at base condition, super compressibility, ideal relative density, ideal heating value, real heating value, Speed of sound (Ultrasonic only) Static pressure, differential pressure, temperature, flow rate, mass flow rate(coriolis only) Today, yesterday, previous hour Flow rate, energy Today, yesterday, previous hour Production time, shut-in time Today, yesterday, previous hour LOGGING Quantity Transaction Record Logging Quantity transaction records are logged on the controllers using Logging portfolio (*1) Table Default Logging File Format File Type File Closing Timing Default Hourly Quantity Transaction Record CSV File Hourly quantity transaction record file Daily quantity transaction record file Contract hour or configuration change date, time, specified data items *1: Please refer to GS 34P02P53-01E STARDOM Logging Portfolio (InfoWell) for the details of logging portfolio specifications. All Rights Reserved. Copyright 2008, Yokogawa Electric Corporation GS 34P02P31-01E Jun. 3, 2010-00

6 and Message Logging The alarms and events are logged in the controllers using Logging portfolio (*1) File Format CSV File Table Default Logging logging file Process alarm, system alarm File Type Audit trail (configuration change) Event logging file User event, event message *1: Please refer to GS 34P02P53-01E STARDOM Logging Portfolio (InfoWell) for the details of logging portfolio specifications. OPERATING ENVIRONMENT Autonomous Controller FCN/FCJ (Except FCN-RTU) Hardware Table Hardware Model (CPU) NFCP100 (FCN) or NFJT100 (FCJ) (*1) Style (CPU) System card S2 or later More than 128 MB *1: Only single CPU can be used when using setting windows and logging portfolio. Software Basic Software FCN/FCJ basic software (*1) Revision R3.10.01 or later Table Software *1: Java function is required as suffix code when using parameter setting windows and logging portfolio Autonomous Controller FCN-RTU Table Hardware Model (CPU) Style (CPU) Hardware NFCP050 S1 or later Table Software Software Basic Software Revision License FCN/FCJ Basic Software R3.10.01 or later For FCN-RTU, the licenses are bundled with CPU module (Model: NFCP050). Select CPU modules with the portfolio licenses required. PC for Configuration Operating environment of the PC for Parameter Setting Window follows the operating environment described in InfoWell GS (GS 34P02P51-01E). PC for Logging follows the operating environment described in Logging Portfolio GS (GS 34P02P53-01E). All Rights Reserved. Copyright 2008, Yokogawa Electric Corporation GS 34P02P31-01E Feb. 2, 2011-00

7 STYLE OF SOFTWARE SUPPLY Media Programs and Help for Gas Flow Calculation Portfolio are supplied with FCN/FCJ Application Portfolio Media. Gas Flow Calculation Portfolio License Autonomous Controller FCN/FCJ (Except FCN-RTU) A Order ID Sheet with the order ID and password comes with the Gas Flow Calculation Portfolio License. After purchase, access the specified YOKOGAWA Web site page and enter the order ID number and password to obtain the license ID number. To use Gas Flow Calculation Portfolio, register the license ID number with the FCN/FCJ system card. Low Power Autonomous Controller FCN-RTU For FCN-RTU, the licenses are bundled with CPU module (Model: NFCP050). Select CPU modules with the Gas Flow Calculation Portfolio License required. MODEL AND SUFFIX CODES (EXCEPT FCN-RTU) Model NT8105J Gas Flow Calculation Portfolio License Suffix Codes -L License W 1 Always 1 Issued online via the Internet 1 Always 1 A Standard Note: To use Parameter Setting windows and Logging Portfolio, FCN/FCJ Basic Software License for Single CPU with Java function is required. Logging Portfolio license is bundled with Gas Flow Calculation Portfolio. If modification of the parameter setting windows is required, Web Application Portfolio License (InfoWell) is required. Web Application Portfolio License (InfoWell) can not be added FCN-RTU NFCP050-S0 ORDERING INFORMATIONS Specify the model and suffix codes when ordering. For the type of software media supplied, refer to the separate GS, Application Portfolios (GS 34P02P20-01E). RELATED DOCUMENTS GS 34P02P51-01E GS 34P02P53-01E TI 34P03A51-01E InfoWell Logging Portfolio (InfoWell) Gas Flow Calculation Portfolio TRADEMARKS STARDOM is a trademark of Yokogawa Electric Corporation. Java is registered trademark of Oracle and/or its affiliates. Other company and product names appearing this document are trademarks or registered trademarks of their respective holders. All Rights Reserved. Copyright 2008, Yokogawa Electric Corporation GS 34P02P31-01E Feb. 2, 2011-00 Subject to change without notice.