OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Similar documents
Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Optical Dissolved Oxygen Meter

Heavy Duty Dissolved Oxygen Meter

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Optical Dissolved Oxygen Meter

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Operating manual. Oxi 3205 O mg/l C. [Sal] Dissolved oxygen (D.O.) meter

Pneumatic high-pressure controller Model CPC7000

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Dissolved Oxygen/Temp Waterproof Tester

Pneumatic high-pressure controller Model CPC7000

Instruction Manual Dräger MSI P7 and MSI P7 plus

Oxymax W COS51D. Technical Information. Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor

Operating manual. TA 197 Oxi. Dissolved Oxygen Depth Armature

Precision digital pressure gauge Model CPG1000

Hand-held pressure calibrator with integrated pump Model CPH6600

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

User Manual PTW-DensiX. D / Di/Zi

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

NEULOG OXYGEN LOGGER SENSOR GUIDE

Pressure transmitter PASCAL Ci4

LogIT Dissolved Oxygen Probe

SensoDirect Oxi200 Dissolved Oxygen Meter Operating instructions

Technical Information Conducal CLY421

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

OxiQuant S. Operating Instructions

GasSense NDIR User Manual

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

PRELIMINARY DATASHEET

HumiSys HF High Flow RH Generator

Electronic gas volume corrector model DGVC-04

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Instruction Manual DO 6. Economy Hand-held Dissolved Oxygen Meter. 68X Rev 2 Apr 08. Technology Made Easy... Part of Thermo Fisher Scientific

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Pocket Oxygen Meter FireStingGO 2

KERN EG/EW Version /02

Oxygen Meter User Manual

Handheld meter Oxi 3150i

AMS 6916 Board mount pressure sensor with ratiometric analog output

STERILIZABLE DISSOLVED OXYGEN SENSORS

We measure it. For gas and water installers. testo hpa. bar

HI 9143, HI 9143M HI 9145

Oxymax H COS21D. Technical Information

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

Bante904 Benchtop Conductivity/Dissolved Oxygen Meter Instruction Manual

MARTINI. instruments. THANK YOU FOR CHOOSING. Sales and Technical Service Contacts:

Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Additel 761 Automated Pressure Calibrators

LM6 LEATHER MOISTURE METER

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Precision level sensing with low-pressure module MS

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

Columbus Instruments

D Issue E Original. Instruction Manual. TIC Instrument Controller

AMS 2710 PCB pressure sensor module with V output

PCDY01 Dissolved Oxygen Meter

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

Pressure Calibrators. Series PC..., PM...

Oxymax COS61/COS61D. Technical Information

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

T02.0.3X.6C-06 Page 1 of 6. Operating Manual for Dissolved Oxygen-Measuring transducer OXY 3610 MP

Additel 780 Series Pressure Controller

Oxygen Sensor with Electrode

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

Additel 761 Automated Pressure Calibrators Selection Guide

Precision pressure sensor Basic version Model CPT6020

Additel 761 Automated Pressure Calibrators

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

EC214 EC215 - EC215R Bench Conductivity Meters

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

High-speed pressure sensor Model CPT6140

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Additel 761 Automated Pressure Calibrators

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

Industrial pressure controller Model CPC4000

Mass Flow Meter (MFM) for Gases

Instruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s

YSI Model 52 Dissolved Oxygen Meter

Technical Data Sheet MF010-O-LC

HI 2314 HI 2315 HI 23151

OC508 Programmable mv Calibrator

628 Differential Pressure Decay Leak Tester

SAUTER FK Version /2016 GB

Digital pressure gauge Model CPG500

Transcription:

OxyScan Graphic Operating Instructions UMS Micro-oxygen sensor 501 Microprocessor instrument

Introduction Thank you for choosing the UMS Micro Oxygen Sensor 501 - a highly advanced product! Please read these operating instructions carefully to avoid damaging the sensor and the measuring instrument. Contents 1. Scope of delivery 2 2. Instructions for handling the instrument 2 3. Description of the control elements 2 4. Commissioning 3 5. Calibration 3 6. Measuring 4 7. Description of the display in measuring mode 4 8. Description of the menu items 5 8.1. Settings 5 8.2. Continuous measurement 6 8.3. Measured values 6 8.3.1. Data transfer 7 9. Storing the sensor 7 10. Additional functions / firmware update 8 11. Operating principle of the sensor 8 12. Liability and warranty 8 13. Technical data 9 14. Appendix 10 1

1. Scope of delivery - the measuring device - the sensor and protective cap - the calibration chamber - the power supply for charging the integrated accumulator - the carrying case - these operating instructions Carefully unpack the measuring system and check that all components have been supplied. 2. Instructions for handling the instrument The delicate sensor tip forms the core component of the oxygen sensor. The membrane at the tip of the sensor of the oxygen electrode can be damaged if it is accidentally struck against an object. If the values displayed on the screen constantly increase, this indicates that the membrane is damaged. If this is the case, the sensor must be replaced or regenerated. 3. Description of the control elements 1 On / off switch 2 Calibration button 3 Menu/Enter: For confirming a selection or to enter the menu 4 Up : Button for moving up within a menu 5 Down : Button for moving down within a menu 6 F - key: Only for customer-specific options, see enclosed sheet where available 2

4. Commissioning The connections for - the measuring cable of the sensor (connection in the centre - 5 pin), - the charger (connection on the left 7 pin) are located at the top of the measuring device. Plug the sensor cable plug into the connection at the measuring device (middle connection 5 pin). Connect the charger with the charger socket on the left at the top of the measuring device to charge the accumulators. The charging circuit will then operate independently until the accumulator has reached its full charge capacity. We recommend turning the measuring device off during the charging process. The measuring device can be kept connected to the charger when the measuring device is not being used to keep the integrated accumulator fully charged. The charging circuit integrated in the measuring device controls the charging process. If the red LED on the keypad is on, the accumulator is being charged. 5. Calibration To calibrate the sensor, place the sensor inside the calibration chamber and press the CAL button on the measuring device. The calibration process then starts automatically and stops once a sufficiently stable calibration value has been reached. The bottom part of the calibration chamber is fitted with a black plug, which holds a plastic sponge. The sponge must be moistened approx. every 4 weeks. To do so, proceed as follows: - Pull out the black plug. - Sprinkle a few drops of water onto the plastic sponge until it is damp. - Close the calibration chamber. - The unit can be used for calibrating after about 15 minutes. The sensor can also be stored in the calibration chamber. When doing so, it must be ensured that the sponge in the calibration chamber is always damp (see above). 3

Note: This oxygen measuring system is a highly advanced product. Your contribution to achieving accurate oxygen content measurements consists of calibrating the system. Frequent calibration increases the accuracy of your measurements! 6. Measurement Once the measuring system has been calibrated, the oxygen content of the respective medium can be measured. Note: The tip of the sensor must be positioned at a medium depth inside the container (although at a minimum depth of 5 cm below the surface). The sensor always requires either a minimum level or constant flow. Please also take this into account when permanently installing the sensor in a system! 7. Description of the display in measuring mode 1: Oxygen content in % saturation 2: Oxygen content in mg/l 3: Temperature in C 4: Air pressure in hpa 5: Bar chart showing the charge level of the integrated accumulator (0..100 %) 6: Diagram of the last 30 measuring values in % saturation (0..160 %sat) 7: Diagram of the last 30 measuring values in mg/l (0..16 mg/l) 8: Diagram of the last 30 temperature measuring values (0..48 C ) 9: Bar chart showing the free capacity level of the measuring value memory (0..5000 values) 10: Current time 4

8. Description of the menu items You can enter the main menu, from which the submenus described in the following can be selected, by pressing the MENU/ENTER button. The submenu items can be selected by using the Up and Down buttons. Once the relevant submenu item has been selected, it can be opened by pressing MENU/ENTER. Pressing CANCEL will bring you back to the measurement screen. Items within the submenus are selected in the same way as described above. 8.1. Settings This menu can be used to configure the following functions: Adjust time: The current time shown by the clock can be adjusted as follows: 1. Move the cursor to the number that is to be adjusted by using the arrow keys 2. Press MENU/ENTER 3. Adjust the number using the arrow buttons 4. Press MENU/ENTER 5. Go back to point 1 and repeat the process or select BACK and press MENU/ENTER NTC correction: Pressure correction: Device information: Language: For adjusting the temperature correction value using the arrow keys, then press MENU/ENTER. For adjusting the air pressure correction value using the arrow buttons, then press MENU/ENTER. Displays the serial number of the device and supplied sensor, the firmware version and important device information for use in error diagnostics. Languages available are German and English. These operating instructions refer to the English version. Note: The value used for the NTC correction depends on the sensor that is being used and has been adjusted at the factory to the supplied sensor. This value normally only requires changing if a sensor other than the one supplied is being used. The value used for the air pressure correction does not normally require changing. 5

8.2. Continuous measurement Select this submenu item to perform continuous measurements. This submenu can be used to configure the following functions: Measuring interval: For adjusting the time intervals between individual measurements. Start now: Start time: Stop measurement: To start a continuous measurement immediately. To specify a time at which a continuous measurement is to be started. This time is selected in the same way as described under point 8.1. Adjust time. To stop the continuous measurement. Note: The continuous measurement will continue even if the measuring device is turned off, although this will result in higher power consumption and hence a reduction in the accumulator s operating time. The shorter the selected measuring intervals, the faster the accumulator will use up its charge. 8.3. Measuring values You can select this menu item to view or further process the measuring values recorded during the continuous measurement: Display values: Display diagram: Delete values: Send IR: Displays the recorded measuring values in tables. Specific measuring values can be selected by using the arrow keys. Press MENU/ENTER to return to the menu. Displays the recorded measuring values as a diagram. Press MENU/ENTER to return to the menu. Deletes all measuring values. To transmit the recorded measuring values via the IR interface (optional). See section 8.3.1. Note: The Send IR menu item is only available on measuring devices that are equipped with an IR interface (optional). 6

8.3.1. Data transfer Only available for units equipped with an IR interface! The supplied IR adapter also enables data to be transferred to non-ir capable devices. In principle, this means that data can be transferred to all devices that enable the following configuration: 19.2 kbps, 8 data bits, no parity, 1 stop bit (= 8N1 ) The measuring device can also be connected to a printer as it transmits data as tables in text format. Use a terminal program for transmitting data to a PC and save the transmitted data in a text file. As the individual measuring values are separated by tabs, and the rows of measuring values by additional lines, the text file can be further processed in most spread sheets (e.g. MS Excel) and databases. It is absolutely vital that the space between the measuring device and the IR adapter is not blocked. If the distance between the measuring device and the IR adapter is greater than 50 cm, the devices may have to be aligned with one another. If the devices are precisely aligned, the distance between them can be increased to up to 5 metres. Caution: Never look directly into the infrared windows! Looking into the infrared windows can cause eye damage! 9. Storing the sensor The sensor is supplied inside the calibration chamber. It must be ensured that the calibration chamber is always kept damp (see point 5, Calibration ). If it is not possible to regularly check the calibration chamber, the sensor can also be stored in another container, in which case it must be ensured that the tip of the sensor is always immersed in water. 7

10. Additional functions / firmware update Depending on its equipment, the microprocessor-controlled measuring device may have additional functions that are not listed in these operating instructions. If this is the case, the description of these functions is usually provided on a separate enclosed sheet. The measuring device can also be equipped with additional functions at a later date. Due to the special microcontroller technology used in the device, we are also able to equip the device with customer-specific functions. Please get in touch for further information on this option! All of the measuring device s functions are controlled by a microcontroller in accordance with a program developed by UMS. This program (= firmware) is stored in a memory module which should only be replaced by UMS or other authorized personnel. The firmware used in the measuring device has been thoroughly tested. We are nonetheless constantly working on upgrades and improvements. If you would like to obtain our latest firmware, just give us a call and tell us your current firmware version (see point 8.1, Device information ). We will then be able to tell you what additional functions a firmware update would provide. 11. Operating principle of the sensor The oxygen sensor is based on the Clark principle and measures the dissolved oxygen in the water. The oxygen diffuses through the membrane at the tip of the sensor and is reduced at the cathode. The electrons released during this process flow to the anode and generate a current that can be electronically analysed in the measuring device. The current flow in the sensor is, however, not only determined by the oxygen content of the water, but also by the temperature of the water and the air pressure. In order to compensate for those factors, the measuring device for our oxygen sensor is equipped with an automatic temperature and air pressure compensation function. 12. Liability and warranty We reserve the right to make technical changes! We do not accept any liability for any damage caused by improper use, incorrect application or functional failures of the device. The entire measuring system is covered by a statutory 6 month guarantee. If the device fails during the warranty period, please return the sensor or measuring device to us together with the test certificate. 8

13. Technical data Measuring ranges Concentration Range: 0.0 19.99 mg/l Resolution: 0.01 mg/l Accuracy: ± 0.1 mg/l +/- 1 digit Saturation index Range: 0.0 199.9 %sat Resolution: 0.1 %sat Accuracy: ± 0.5% ± 1digit Temperature Range: 0.0 50.0 C Resolution: 0.1 K Accuracy: 0.5 K ± 1digit Air pressure Range: 800 1150 mbar Resolution: 1 mbar Accuracy: 10 mbar Temperature compensation automatic, range: 0... 50 C Air pressure compensation automatic, range: 800... 1150 mbar Ambient temperature 0 C - 70 C (Measuring device) Display Electrode Power supply graphics capable LCD 128 x 64 pixels Pt cathode, Ag anode integrated accumulator 3.6 V / 2.1 Ah, NiMH Measuring device dimensions 223 x 105 x 40 (LxWxH, mm) Sensor dimensions 200 x 4,7 (Lx, mm) Measuring device weight Sensor weight Polarization voltage Polarization time Sensor response time approx. 500 g approx. 20g 750 mv max. 5 min approx. 30s The useful life of the electrolytes amounts to approx. 2 years. The sensor is miniaturized and can therefore not be regenerated by the user. This also eliminates a number of potential error sources that can arise as a result of the regeneration process. 9

14. Appendix (The following tables only apply in reference to the outlined conditions) Table and diagram Oxygen content of freshwater at saturation in dependence on the water temperature Sauerstoffgehalt in mg/l 15 14 13 12 11 10 9 8 7 6 5 0 5 10 15 20 25 30 35 40 45 50 Temperatur in C Maximum dissolved oxygen content in freshwater in mg/l at different temperatures and normal pressure (1013hPa = 760Torr) C mg/l C mg/l C mg/l C mg/l 0 14.64 10 11.25 20 9.08 30 7.55 1 14.23 11 10.99 21 8.90 31 7.42 2 13.83 12 10.75 22 8.73 32 7.30 3 13.45 13 10.51 23 8.57 33 7.18 4 13.09 14 10.28 24 8.41 34 7.06 5 12.75 15 10.06 25 8.25 35 6.94 6 12.42 16 9.85 26 8.11 36 6.83 7 12.11 17 9.64 27 7.96 37 6.72 8 11.81 18 9.45 28 7.82 38 6.61 9 11.53 19 9.26 29 7.69 39 6.51 10 11.25 20 9.08 30 7.55 40 6.41 10

Oxygen content of seawater at saturation in dependence on salt content (density) and temperature at normal pressure (1013hPa = 760Torr) Density 10 C in g/cm 3 O 2 in mg/l 15 C O 2 in mg/l 20 C O 2 in mg/l 25 C O 2 in mg/l 30 C O 2 in mg/l 1.000 11.25 10.06 9.09 8.26 7.49 1.005 10.81 9.69 8.76 7.96 7.21 1.010 10.38 9.32 8.44 7.65 6.93 1.015 9.94 8.95 8.11 7.35 6.65 1.020 9.51 8.58 7.79 7.05 6.38 1.025 9.07 8.21 7.46 6.74 6.10 1.030 8.64 7.85 7.14 6.44 5.82 Salt content (salinity in g/l = ) of seawater in dependence of temperature and density Density 10 C in g/cm 3 salinity in 15 C salinity in 20 C salinity in 25 C salinity in 30 C salinity in 1.000 0 0 0 0 0 1.005 6.7 7.5 8.5 10.8 13.1 1.010 13.2 14.4 15.6 17.2 18.8 1.015 19.6 20.9 22.1 23.6 25.1 1.020 26.0 27.3 28.6 30.6 32.6 1.025 32.5 33.9 35.3 37.1 38.9 1.030 38.8 40.4 42.0 44.2 46.4 If you have any technical queries or want to order additional accessories or sensors, please contact your distributor or get directly in touch with UMS GmbH & Co. KG Wolfsgrube 7 D-98617 Meiningen Germany Phone: +49-36 93-94 03 50 Fax: +49-36 93-94 03 59 info@ums-gmbh.de 11