CPR MEDICAL DEVICES INC. OPERATING MANUAL

Similar documents
CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

AUTOVENT 4000 VENTILATOR

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

2 PRE USE FUNCTION CHECK 3 OPERATING PROCEDURE 4 SERVICING. 5 CAREvent ALS ACCESSORIES 11

Virginia Beach EMS. Oxylator EMX. Debra H. Brennaman, RN, MPA, NREMT-P

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

Operation and Maintenance of the EPV200 Portable Ventilator

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

O-Two Self-Study Guide. Equinox Relieve

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

BOC: Living healthcare. Manual. LIV IQ BOC Integrated Valve with digital display portable delivery system for Medical Oxygen. BOC: Living healthcare

Rev. B. Operating Instructions

Equinox II NITROUS OXIDE / OXYGEN ADMINISTRATION EQUIPMENT 01EQ7000E

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

USER MANUAL (For G2005 Model)

USER MANUAL AUTOMATIC AND MANUALLY TRIGGERED RESUSCITATOR. O-TWO MEDICAL TECHNOLOGIES INC. Innovation in Resuscitation

Emergency Transport and Ventilation

User Instruction Manual

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

Oxygen Dialflow Meter. Instructions for Use

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

OXY-life TM. Oxygen Resuscitator OPERATING MANUAL

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Yoke Block Instruction Manual

Oxygen Dialflow Meter. Instructions for Use

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL

Yoke Block Instruction Manual

LRS(H)4 Pressure-Reducing Regulator User Manual

45A, Armthorpe Road, Brampton, Ontario, Canada, L6T 5M4. Made in Canada by O-Two Medical Technologies Inc.

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT

Mirage Vista Nasal Mask

CSA Sample Draw Aspirator Adapter Operator s Manual

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

MODEL NUMBER: P PORTABLE COMPRESSOR

Hospital and Transport for Controlled Breathing

Product Information News

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

OXY-VIVA 3 RESUSCITATOR OPERATING INSTRUCTIONS

MACS Mask CPAP System

English USER GUIDE User guide

Vapotherm Q50 Compressor. Instructions for Use

PERFORM Operating Document

Budget Range Operators Handbook

Dialflow Regulator. Instructions for Use

MODEL NUMBER: P PORTABLE COMPRESSOR

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

PORTER INSTRUMENT COMPANY, INC.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

OPERATION MANUAL NTF-15

444C DUAL PERFORMANCE VALUE PACK

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

200 PSI COMPRESSORS - MODEL NUMBERS

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

Micro Dial-Flowmeter. Instructions for Use

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

OPERATION MANUAL NTF-60 Plus

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Pressure Regulator. Instructions for Use

RAM 4021 Operation Manual

Aluminum 13 cu tank Includes regulator Fill pressure: 3,000 psi (200 bar) Output: 1,100 psi +/- 10% (75bar)

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Stroller. Sprint S T R O L L E R S P R I N T

NeoNatalie Resuscitator Oxygen kit

MMR Air Mask With. with Quick-Connect Hose

Mass Casualty Ventilator Models: MCV100 & MCV100-B

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

1200B2 Series Service Regulators. Instruction Manual

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

RecoverXLT Oil-Less Universal Refrigerant Recovery System. (For serial numbers and higher)

PERFORM Operating Document

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

100C Air Compressor Kit

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

C-1 C-7. C-6 Short air tubing Upper Velcro straps. C-a C-5 C-2 C-4 C-3 B-1 B-9 B-10 B-2 B-7 B-8 B-3 B-6 D-1 D-2 D-13 D-3 D-12 D-10 D-11 D-4 D-5 D-8

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

NeoNatalie Resuscitator Oxygen kit

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

RG3100 and RG3100Ice Regulator System

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

AND OPERATION INSTRUCTIONS

PC1131 Electric Air Compressor

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Transcription:

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR OXYLATOR EMX RESUSCITATION AND INHALATION SYSTEM

Symbols used in the Operating Manual for the OXYLATOR EMX and/or on the OXYLATOR EMX unit: WARNING! Do not use grease or oil! Do not use near open flames or while smoking! Do not use a wrench! Do not autoclave! O Oxygen Release Button SN Serial Number INH Inhalator Button Caution! Warning! Consult accompanying documentation! The OXYLATOR EMX contains patented technology developed by CPR Medical Devices Inc., 161 Don Park Road, Markham, Ontario, L3R 1C, Canada U.S. Patent No. 5,30,330 Global patents and further U.S. patents pending The OXYLATOR EMX Operating Manual is published by: CPR Medical Devices Inc., Vol. I, 1/00 Applies to Series "H (fourth character of serial number)

TABLE OF CONTENTS Page Table of Contents ----------------------------------------------------- 3 Section 1 --- Information for the User ---------------------------- 4, 5 Section --- Technical Description and Features --------------- 6, 7 OXYLATOR EMX Components (Diagram) ---------------- 8, 9 Section 3 --- Modes of Operation ---------------------------------- 10 Section 4 --- Operating Instructions ------------------------------- 11 Section 5 --- Cleaning and Disinfecting -------------------------- 1, 13 Section 6 --- Maintenance ------------------------------------------ 14 Section 7 --- Warranty ---------------------------------------------- 14 Section 8 --- Specifications ----------------------------------------- 15 CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.

SECTION 1... INFORMATION FOR THE USER ------------------------------------------- Indication for Use: The OXYLATOR EMX is an oxygen powered resuscitator intended to provide emergency ventilatory support for individuals weighing more than 10 kg ( pounds). Ventilation may be performed using a mask or an endotracheal tube. Warnings: - The OXYLATOR EMX should be used only by individuals who have adequate training in CPR techniques and the operation of oxygen powered resuscitators. - Do not use any type of one-way valve between the OXYLATOR EMX and the patient; its use will cause the system to malfunction. - Do not expose the OXYLATOR EMX to MRI (magnetic resonance imaging) environments. - Do not use grease or oil on the OXYLATOR EMX for any reason. - Do not use the OXYLATOR EMX in oxygen deficient atmospheres or near open flames. - Do not autoclave the OXYLATOR EMX. - Ensure that the OXYLATOR EMX is completely dry before exposing it to freezing conditions. Liquid or water in valves may cause them to malfunction in freezing conditions. See Section 5: Cleaning and Disinfecting, pages 1 & 13. - Do not smoke while using the OXYLATOR EMX or any other oxygen equipment. - Do not use wrenches or any other tools on the OXYLATOR EMX. Hand-tighten all parts including the hose while connecting or disconnecting it to the unit. - Do not dismantle or attempt to remove any components other than those required for routine cleaning. Any tampering with the OXYLATOR EMX may cause the unit to malfunction, and will automatically void the warranty. 4

Precautions: - The OXYLATOR EMX should be connected to a pressurized source supplying a minimum constant flow of 30 litres per minute and between 45 psig to 80 psig or 3.0 bar to 5.5 bar. - When an operator observes an abnormally long inspiratory phase (greater than seconds in adults and greater than 1 second in a child), the OXYLATOR EMX should only be used in manual mode and the inspiratory phase restricted to approximately seconds for an adult and 1 second for a child. See page 10, 1. - When ventilating an intubated patient, higher pressure release settings may be required. Select a pressure setting of 30 cm HO to start and adjust if necessary. - An audible, rapid clicking sound or buzzing sound and rapid movement of the tip of the main valve indicates airway obstruction. Clear the airway, and then resume the ventilation procedure. - The OXYLATOR EMX should be subjected to high level cold disinfection or boiling water after each patient use. - Replace the filter after each patient use and/or if the valve becomes contaminated with vomitus during a CPR attempt. - Please review and follow the instructions and observe the warnings in this manual before using the OXYLATOR EMX - If the use or operation of the OXYLATOR EMX is unclear, contact your dealer or agent for clarification. - The OXYLATOR EMX is a resuscitation management system and should not be used as an unattended automatic ventilator. - When several OXYLATOR EMX are cleaned simultaneously, assure that the serial number on the valve (8) and the pressure release selector (10) match when reassembling the unit. See Section 5, Cleaning and Disinfecting, pages 1 & 13. 5

SECTION... TECHNICAL DESCRIPTION AND FEATURES --------------------------------------------------------------- Description: The OXYLATOR EMX is an oxygen powered resuscitator/ inhalator which requires no power source (i.e. battery) other than the supply of compressed oxygen in an appropriate cylinder or wall outlet. The oxygen supply hose of the OXYLATOR EMX should be connected to its pressurized source supplying a minimum constant flow of 30 litres per minute and between 45 psig to 80 psig or 3.0 bar to 5.5 bar. During the continuous cycling mode, the inspiratory flow of oxygen will be initiated upon complete, continuous depression of the OXYGEN RELEASE BUTTON. A sensing chamber in the OXYLATOR EMX allows airway pressure to increase to the maximum limit set, at which point the system shuts off the inspiratory flow, allowing passive exhalation to take place. Upon sensing the completion of the exhalation phase, the valve automatically resets and allows the inspiratory flow to start a new cycle. Cycling continues as long as required, provided the OXYLATOR EMX is connected to pressurized oxygen and its OXYGEN RELEASE BUTTON is continuously, fully depressed. The inhalation mode is activated by rotating the INHALATOR KNOB counterclockwise allowing the oxygen flow to be mixed with ambient air with a patient's own inspiratory effort. The flow in the inhalation mode vents out of the valve and does not subject the patient's airway to any pressurization, permitting patients to breathe unassisted. If a return to automatic cycling mode is needed, full and continuous depression of the OXYGEN RELEASE BUTTON is required. This automatically overrides the inhalation mode. Gauge Port (Optional): A gauge (optional) can be connected to the OXYLATOR EMX at the gauge port connection (19) to verify pressure readings in the airway. 6

Features: - Meets ISO, Resuscitators Intended for Use with Humans - Meets American Heart Association Guidelines 000 for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Part 6: Advanced Cardio- Vascular Life Support, Section 3: "Adjuncts for Oxygenation, Ventilation, and Airway Control - Extremely light-weight, impact resistant and durable - Simple to learn - Easy to use - Single use, quick change filter element - Few moving parts, minimal maintenance required - Adjustable airway pressure limiting from 0 cm to 45 cm of H O - Constant maximum flow rate of 30 litres per minute - Manual and continuous cycling - Built-in inhalator capability - Compatible with oxygen supply tanks and regulators supplying between 45 and 80 psig inlet pressure and constant minimum flow rate of 30 litres per minute - Hold-down oxygen release mechanism - PEEP capability - Eliminates the risk of "air trapping" or "stacked breath" - FIO of 1.0 during resuscitation - Oxygen powered, no waste of O supply for operation - Audible and visual indication of airway obstruction 7

OXYLATOR EMX COMPONENTS 14 Top Cap 11 Exhaust Ports 1 Oxygen Hose Connection - DISS 19 Gauge Port Connection Patient Connector Oxygen Release Button 7 Patient Connector Patient Connector 18 13 Inhalator Knob Indicator Eye 8

OXYLATOR EMX COMPONENTS 10 Pressure Release Selector 18 Indicator Eye 9 Valve Stem 1 5 Ports 17 Valve Tip 15 Venting Ports Spring 8 Main Valve 4 Primary Sensing Chamber 6 3 Filter Secondary Chamber 16 Cartridge 9

SECTION 3... FOUR MODES OF OPERATION OF THE OXYLATOR EMX -------------------------------------------------------------------------------------- 1. MANUALLY ACTIVATED CYCLE FOR NON BREATHING PATIENT - The inhalator knob (13) is closed. Inspiratory flow can be initiated for a single cycle by depressing the oxygen release button (1) and holding it down until the OXYLATOR EMX releases at the end of the inspiratory phase, or until chest expansion is considered sufficient for adequate ventilatory exchange and the oxygen release button (1) is let go. Passive exhalation will then take place. The inspiratory phase should be restricted to seconds in an adult and 1 second in a child. The level of pressure release is set by rotating the pressure release selector (10) to the desired value. A new inspiratory cycle can then be initiated by depressing the oxygen release button (1) once again upon completion of exhalation. This mode will not maintain a baseline pressure (PEEP) and upon complete exhalation the airway pressure will be at 0 cm HO. The OXYLATOR EMX will cycle as in "continuous mode" if the oxygen release button (1) is held depressed constantly as in mode.. CONTINUOUS CYCLE WITH BASELINE PRESSURE (PEEP) FOR NON BREATHING PATIENT - (should only be engaged when the inspiratory time does not exceed seconds in an adult or 1 second in a child) The inhalator knob (13) is closed. The system will cycle continuously when the oxygen release button (1) is either continually depressed or held down and then rotated clockwise to seal and activate oxygen flow. This function overrides the inhalation mode automatically. The OXYLATOR EMX will cycle from an inspiratory to expiratory cycle maintaining positive airway pressure throughout the cycle with a baseline pressure (PEEP) value of to 4 cm HO. The system will end the inspiratory cycle upon reaching the preset maximum airway pressure level indicated by the pressure release selector (10). This allows unassisted passive exhalation to take place until the expiratory flow diminishes to a level of to 4 cm H O PEEP. Then, OXYLATOR EMX will automatically start a new inspiratory cycle. When an operator observes an abnormally long inspiratory phase (greater than seconds in an adult or greater than 1 second in a child), the OXYLATOR EMX should only be used in manually activated cycles. See mode 1. 3. MANUALLY ACTIVATED CYCLE WITH BASELINE PRESSURE (PEEP) FOR NON BREATHING PATIENT - system will maintain a baseline pressure (PEEP) if the inhalator knob (13) is opened counter-clockwise and the OXYLATOR EMX is operated as in mode 1. This will provide a baseline pressure (PEEP) of to 4 cm HO. 4. INHALATION OF OXYGEN ENRICHED AMBIENT AIR FOR BREATH- ING PATIENT - system can be used in this mode by rotating the inhalator knob (13) counter-clockwise which will allow the air to be enriched with oxygen as a patient breathes on his/her own. The oxygen release button (1) cannot be in a depressed position in the inhalation mode. 10

SECTION 4... OPERATING INSTRUCTIONS ----------------------------------------- The following instructions are for the proper use of the OXYLATOR EMX They are to be followed to provide adequate ventilation when attempting Cardiopulmonary Resuscitation. The user of this device must have knowledge of cpr techniques. The instructions deal strictly in the proper use of the device. 1. The OXYLATOR EMX hose must be connected to the available oxygen supply, a wall outlet or a pressurized cylinder.. When using a pressurized cylinder, open main valve and ensure regulator indicates a reading of between 40 psig and 80 psig; adjust if necessary. 3. Attach suitable mask or endotracheal tube to patient connection (7), make sure mask is rotated into proper position so that an effective seal can be achieved. 4. Ensure inhalator knob (13) is fully closed, and depress oxygen release button (1) briefly to test for oxygen flow. 5. Rotate maximum airway pressure release selector (10) to desired setting simply by aligning pressure value with the indicator eye (18). The pressure can be adjusted from 0 to 45 cm H O. It should be initially set at 0 cm H O and increased if the operator in his or her opinion determines that the patient needs greater airway pressure. When used with an endotracheal tube, select a maximum airway pressure of 30 cm H O to start, then adjust as required. 6. After positioning person and establishing a proper airway, place mask on person's face so as to achieve a complete seal with one hand; using the other hand, depress oxygen release button (1) completely while maintaining mask seal against the person's face. Hold down oxygen release button (1) FIRMLY, or if appropriate, depress, then turn oxygen release button (1) clockwise for continuous oxygen flow. The unit will start cycling continually. OXYGEN RELEASE BUTTON (1) MUST BE HELD MANUALLY DEPRESSED OR KEPT IN LOCKED-IN POSITION AT ALL TIMES FOR CONTINUOUS CYCLING. CAUTION; WITHOUT A PROPER MASK SEAL THE DEVICE CANNOT CYCLE. A NON-CYCLING DEVICE INDICATES THAT IMPROVEMENT IN AIRWAY MANAGEMENT INCLUDING A PROPER MASK SEAL IS NEEDED. 7. An audible, rapid "clicking" or buzzing sound indicates airway obstruction, STOP!, take necessary steps to clear airway, then reposition person to continue. REPEAT step # 6. An obstruction is also confirmed by observing the rapid movement of the valve tip (17) of the main valve (8). 8. A natural breathing pattern will ensue as the OXYLATOR EMX continually cycles. Ensure that the inspiratory phase does not exceed seconds in an adult or 1 second in a child at any maximum airway pressure setting selected. Switch to manual mode if necessary. see page 10. 9. To stop flow of oxygen, let go of the oxygen release button (1) or, if oxygen release button (1) is in locked-in position, rotate it counter-clockwise. 10. If the OXYLATOR EMX stops cycling during continuous cycling, release the OXYGEN RELEASE BUTTON (1) and restart after increasing the pressure by rotating the PRESSURE RELEASE SELECTOR (10) by 5 cm HO. In some patients, higher cycling pressures are required to overcome increased airway resistance. 11

SECTION 5... CLEANING AND DISINFECTING --------------------------------------------- The components of the OXYLATOR EMX are made from acetal, aluminum and stainless steel. This enables the unit to be cleaned and disinfected routinely after each use. The OXYLATOR EMX must be cleaned, disinfected and the filter replaced after each use. CLEANING THE OXYLATOR EMX. 1. Separate the OXYLATOR EMX from oxygen hose connection ().. Detach patient connection (7) by rotating its knurled rim in a counterclockwise direction. 3. Remove and DISCARD the USED FILTER (6) from its place in the patient connection (7). 4. Detach top cap (14) by unscrewing in a counter-clockwise direction; pull out main valve (8) from its chamber. 5. Use a mild soap solution to wash out the four components. Then rinse the four components thoroughly with distilled water. 6. Wipe off the water from all components. Firmly tap the components of the unit against the palm of the hand and wipe off the water. Perform for both ends of the valve body, the main valve (8), top cap (14) and the patient connection (7). Repeat this step as necessary until no water droplets are observed. 7. Insert main valve (8) into its chamber and screw on top cap (14) clockwise. DO NOT OVERTIGHTEN! HAND-TIGHTEN ONLY. Assure that serial number on main valve (8) is identical to serial number on the pressure release selector (10) when cleaning more than one OXYLATOR EMX at a time. 8. Attach hose to oxygen hose connection () by hand. Depress oxygen release button (1) to check for flow. Cover the patient connection end (7) of the valve body with the palm of the hand and depress oxygen release button (1) for a short burst to clear away any trapped water residue. Blot any resulting water droplets. Remove top cap (14) and main valve (8) and blot out any visible liquid in the valve body, on the main valve (8) and top cap (14). Repeat this step of blowing oxygen/ drying until no moisture is visible in the main body, the main valve (8) and top cap (14) and that all components are dry. Reassemble main body, main valve (8) and top cap (14). 9. Insert a new filter (6) into its position in patient connection (7). Screw patient connection (7) clockwise onto unit.! DO NOT OVERTIGHTEN! HAND-TIGHTEN ONLY. 10. Remove hose connection from pressure source. DISINFECTING THE OXYLATOR EMX. 1. Follow steps 1 through 4 above, wash out and rinse the four components, then disinfect components using a disinfecting solution; or boiling water. Then rinse the four components thoroughly again with distilled water.. Continue with steps 6 to 10 above. 1

INSTRUCTIONS FOR CLEANING THE OXYLATOR EMX AFTER CONTAMINATION BY VOMITUS. ----------------------------------------------------------------------------------- 1. Remove mask from patient connection (7).. Detach patient connection (7) by rotating its knurled rim in counter-clockwise direction. 3. Remove and discard the used filter (6) from its place in the patient connection (7). 4. If necessary, wipe clean inside secondary chamber (3), depress the oxygen release button (1) to blow out any possible materials that may have penetrated through the particle filter (6), wipe secondary chamber (3), clean again if necessary. 5. Insert new filter (6) into its position in patient connection (7). Screw patient connection (7) clockwise onto unit. DO NOT OVERTIGHTEN! Press the oxygen release button (1) for a quick burst of oxygen to check for flow. 6. Attach mask (new or cleaned) to patient connection (7). 7. The OXYLATOR EMX is ready for use again. NOTE: A filter change should normally take approximately 0 seconds. DISASSEMBLY FOR CLEANING THE OXYLATOR EMX 7 PATIENT CONNECTION 6 FILTER VALVE BODY 8 MAIN VALVE 14 TOP CAP ***WARNING*** ENSURE THAT THE OXYLATOR EMX IS DRY BEFORE EXPOSING THE UNIT TO FREEZING CONDITIONS. LIQUID OR WATER IN VALVES MAY CAUSE THEM TO MALFUNCTION IN FREEZING TEMPERATURES. DO NOT AT ANY TIME USE GREASE OR OIL FOR ANY PURPOSE ON THE OXYLATOR EMX. DO NOT USE THE UNIT IN OXYGEN DEFICIENT ATMOSPHERES OR NEAR OPEN FLAMES. DO NOT SMOKE WHILE USING THE OXYLATOR EMX OR ANY OTHER OXYGEN EQUIPMENT. DO NOT AUTOCLAVE THE OXYLATOR EMX. 13 13

SECTION 6... MAINTENANCE ----------------------- Due to the revolutionary new design and functional characteristics of the OXYLATOR EMX, minimal maintenance is required! The OXYLATOR EMX will function for millions of cycles without requiring any form of maintenance. However, the unit should be periodically subjected to short "bursts" of a few seconds (1 - seconds). This can be accomplished simply by depressing the oxygen release button (1) with the unit connected to its pressure supply. If for ANY REASON the unit malfunctions, remove the device from service and contact your sales person, distributor, or agent for help. If the problem cannot be solved, the device should be returned to CPR MEDICAL DEVICES INC. or its distributor in your territory for repair or replacement. DO NOT DISMANTLE OR ATTEMPT TO REMOVE ANY COMPONENTS OTHER THAN THOSE REQUIRED FOR ROUTINE CLEANING! ANY TAMPE- RING WITH THE OXYLATOR EMX WILL VOID THE WARRANTY AND MAY CAUSE THE UNIT TO MALFUNCTION! SECTION 7... WARRANTY ------------------ CPR MEDICAL DEVICES INC. warrants this product to be free from any defects in material and workmanship for a period of five (5) years from the date of purchase to the initial purchaser. Warranty card must be completed to validate warranty. The warranty will be void if any filters are used other than the ones supplied by CPR MEDICAL DEVICES INC. or its distributors. All shipping charges for returned goods should be prepaid. Upon inspection and evaluation of the returned unit by CPR MEDICAL DEVICES INC. or its distributors, the OXYLATOR EMX will be either replaced or repaired to conform to the required standards. Any evidence of tampering or disassembly of the valve for any purpose other than routine cleaning and maintenance shall void this warranty. CPR MEDICAL DEVICES INC. shall in no event be liable for any consequential damages, nor for loss, damage or expenses directly or indirectly arising from the use of the OXYLATOR EMX. 14

SECTION 8... SPECIFICATIONS ------------------------- Model - OXYLATOR EMX Weight Dimension dia * length Material of housing Required source pressure Required flow (source) Dead Space Inspiratory flow rate Minute volume delivered Min. time of oxygen supply I : E ratio PEEP Ventilatory frequency Range of pressure relief Expiratory resistance - 0.5 kg; 0.55 lbs -.5 in. * 4.5 in., 57mm * 108mm - Acetal - between 45 psig to 80 psig, or between 3.0 bar and 5.5 bar - min. 30 litres per minute - 0 millilitres - 30 litres per minute (max) - 10 to 1 litres per minute in auto mode - Cylinder vol. divided by 1 l/min - 1 : 1 to 1 : or manually controlled - to 4 cm H O in auto mode - Auto-adjusting to lung capacity in auto mode - 0 to 45 cm H O, 14.5 to 35 mm Hg - approximately 5 cm H O in manual mode Suitable body mass range - 10 kg+, lbs + Inhalator flow - 0 to 15 litres per minute of 100% O Oxygen concentration Filter Mask/airway connections Usage temperature range Storage temperature range Obstructed airway warning Oxygen inlet connection - 100% during resuscitation mode - Single use, disposable - 15mm internal / mm external - - 30 C - + 60 C, - F - +140 F - - 40 C - + 70 C, - 40 F - +158 F - Rapid cycling, audible and visual - DISS, ISO standard or quick connect NOTE: Data on functional characteristics can fluctuate under varying conditions. Please OBSERVE INSTRUCTIONS AND WARNINGS in this operating manual. 15