TTL Flash Interface connections

Similar documents
TTL Converter for Nikon DSLR with Nikonos N5 Connector (Version 2)

Underwater Housing for Canon EOS 100D Rebel SL1. Housing Kit for Canon EOS 100D Rebel SL1. Product Registration. Product Number 6970.

Connections The C20B can be connected either using the Molex locking socket, or by connection to four plated through holes. The plated through

200DLM/A Underwater Housing for Canon EOS M50, EOS Kiss M

200DLM/A Underwater Housing for Canon EOS M5 Mirrorless Digital Camera

TH-1800-T TRX-700-CNG Converter

Electronic Automatic Transmission for Bicycle

AMS 2710 PCB pressure sensor module with V output

REASONS FOR THE DEVELOPMENT

200DLM/B Underwater Housing for Panasonic Lumix G85, G80 Mirrorless Micro Four-Thirds Digital Camera

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

Underwater with the RX-100 By Neal Katz

SECTION 2 SMART PAYOUT MANUAL SET FIELD SERVICE MANUAL

Underwater TTL Housing for Panasonic Lumix LX100, Leica D-Lux (Typ 109)

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certifi cate of Secondary Education

DIY - PC - Interface for Suunto Cobra/Vyper/Mosquito

Underwater Housing for Sony Alpha a6300 Mirrorless Camera

e2c 20 - easy to connect

OC508 Programmable mv Calibrator

GATE 2 Part No

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

GasSense NDIR User Manual

Stand-Alone Bubble Detection System

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

AUTO PUMP STATUS CENTER

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual

Underwater Housing for Sony Alpha A6000

STARLOG. Capacitive Water Depth Probe

Mass Flow Controller (MFC) for Gases

MANUAL KPS Pressure Control Valve

A4s Operation Manual

Pneumatic Outflow Control

INSTRUCTION MANUAL. Lesker Model KJL615TC-K Lesker Model KJL615TC-H. Digital Vacuum Gauge/Controller. KJL615TC K/H Ranges

Variable Area Flow Meters

UNDERSTANDING, ACCELERATED

Mass Flow Controller (MFC) for Gases

Fantasea F580EX Mark II Flash Housing for Canon 580EX Mark II Speedlite

AD500 INSTRUCTION MANUAL. Product #20080

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

Mass Flow Controller (MFC) for Gases

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

SVEA II GSM Connector User Manual

GV Standard X-Vent. Setup, Commissioning & Installation Guide

RG2 Gripper Datasheet Version 1.6

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

CONTROL and INSTRUMENTATION

AN-140. Protege WX SALLIS Integration Application Note

GOLT! RED LIGHT DISTRICT

MES Flowmeter Sizes - Specifications. ManuFlo (c) Manu Electronics 2015

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

3.0 Pressure Transmitter Selection

Installation and operating instructions. Controller MO 36. for swing gate operators with 24Vdc motors with pulser

Transmitter CS 21 Operation Manual

When buying one of our prototypes you agree with this!

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

NEW. Mallia TM modular. These products are part of Power Line Carrier technology system > See p

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Technical Data Sheet MF010-O-LC

Sensoric 4-20 ma Transmitter Board Operation Manual

Maintenance of the Electronic ( EPC ) Pressure Controllers on GCs

IECEx Certificate of Conformity Annexe

JUMO dtrans p30 Pressure Transmitter

OMNISPORT 2000 SWIMMING QUICK REFERENCE

Mass Flow Meter (MFM) for gases

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

! Warning, refer to accompanying documents.

CBC2 performance with switched capacitor DC-DC converter. systems meeting, 12/2/14

Electrical Shore Connections

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

Evaporative Emissions (EVAP) system, checking

D Issue E Original. Instruction Manual. TIC Instrument Controller

Mass Flow Controller (MFC) for Gases

APA software instruction manual

Oxymax COS61/COS61D. Technical Information

AMT-Ex Dewpoint Transmitter

Quick Start Installation Guide

660 Multipoint Electronic Level Switch

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

82C288 BUS CONTROLLER FOR PROCESSORS (82C C C288-8)

OEM Manual. MODEL ½ Digit DRUM SCALE

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

LEVIFLOW INTEGRATED FLOWMETER LFIF USER MANUAL

Datasheet: K-30 ASCII Sensor

INSTRUCTION MANUAL. process. Ultrasonic Flowmeter Range

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Relay Judging Platforms with Speedlights

Summary of Architecture Parallel Session. G. Hallewell/CPP Marseille P. Piattelli/ LNS Catania

INSTALLATION INSTRUCTIONS AND REFERENCE HANDBOOK

Roller AC Servo System

Columbus Instruments

Mass Flow Controller (MFC) for Gases

Features. RP011 - Compact Multimedia X-Slim Keyboard. Brief Specification Product Dimension: Keyboard:320(L) 160(W) 14.5(H)mm

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Water Level Indicator Project

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

Instruction and Maintenance Manual

Transcription:

TTL Flash Interface connections Nikon TTL Hot-shoe Interface Gnd = Ground, Earth, Mass, Common. X = X (trigger) contact. Q = Quench or TTL stop. Rdy = Ready to fire SP = Speedlight present (Monitor). The Nikonos interface (below) is electrically identical. Nikonos TTL flash interface Nikonos bulkhead socket. Nikonos camera. Nikonos plug on sync.cable. Nikon interface connections and signals (analogue) Rdy (strobe ready to fire): When the strobe asserts a +3 V active high signal to the Rdy contact, a Nikon or Nikonos film camera switches to X-sync speed if a higher speed has been selected. Rdy high also turns-on the viewfinder lightning-bolt symbol. The Nikonos and some other cameras draw a few ma from the Rdy line, the viewfinder LED being powered directly through a resistor. The ready line can therefore be used as a power supply for low-power circuits that can run on 3 V (but the Sea & Sea strobes with Duo connector and the YS60N are a special case, see below). X (Trigger): The camera shorts the X-contact to ground when the shutter is fired. Electronic SLR cameras use a thyristor for this function, and the X-terminal short-circuit output current from the strobe(s) must be limited to no more than about 1.5 ma to allow the thyristor to de-latch after firing. The strobe input is typically a logic-gate with a pull-up resistor to the logic B+ rail, and the value of the pull-up resistor sets the X-terminal current in the logic-low state. Up to 2 strobes can be connected in parallel, so strobe designers should choose the pull-up resistor so that the X-terminal short-circuit current is no more than about 750 μa (e.g., the pull-up resistor for 5V logic is 6.8 kω). Earlier strobes that use 3.3 kω pull-up resistors (or less) must be modified for dual-strobe use with electronic cameras. Q (Quench / TTL stop): In a conventional TTL flash system, the camera integrates the light falling on the film (using a phototransistor and a capacitor), and when the integrated level reaches a threshold determined by the film ISO (ASA) setting, the Quench line is shorted to ground via a transistor. The Quench signal tells the strobe to switch-off the flash-tube current. The camera calibration specification is that for ISO100, an aperture of f/5.6, and constant LV15 (K=1.16) from a light box, the time between X going low and Q going low (txq) is 820μs. This is slightly shorter than the 'ideal' 977 μs (1/1024 s), to allow the strobe some time to switch off. Out of ISO range: When the camera ISO setting is too high for accurate TTL flash operation, a Nikon film camera holds the Q line low as a warning signal, and TTL control is unavailable. The Nikonos V holds Q down for ISO 400 or higher. Since Q low with X high is a warning signal, this

situation should never be allowed to occur during the normal firing sequence, i.e., after firing the strobe, Q should be returned high before X is returned high. In Nikonos SB-series strobes, and original Ikelite Substrobes, Q low with X high causes the Rdy output to pulse on and off (i.e., it causes the viewfinder ready symbol to flash). The SP (Monitor) function: ("speedlight present" is probably not what SP stands for, but is a good enough way of remembering what it does). If the interface is implemented as Nikon intended, when a TTL capable camera is connected to a TTL capable strobe, a current of around100-250 μa flows along the SP line (camera positive). Since the SP input of a Nikon SB-series strobe is the base of a bipolar transistor, a voltage of 0.6 V - 0.7 V will be seen at the SP terminal of a Nikon strobe when the current is flowing. If the Camera cannot detect a current flowing in the SP line, it will not output a Quench signal. Why this feature was included is not clear. It seems to serve no useful purpose and makes the system less reliable. Independent users of the Nikon interface often disable the SP function by grounding the camera terminal via a resistor. A resistor of value between about 3.3 kω - 11 kω works well for Nikon film SLR cameras. 3.3 kω - 6.8 kω works well for the Nikonos V and RS-AF. Drawing a small amount of current from the SP line fools the camera into believing that a TTL strobe is connected. Note: The SP connection serves a different function with the later Nikon digital SLR cameras (The dttl and ittl systems). The interface protocol has changed completely and, unless an adapter module is used, such cameras will only operate in manual flash mode and SP must be left disconnected when using non-nikon non-dttl compatible strobes. Hence the camera information given here applies mainly to the Nikonos, Nikon 35 mm film SLRs, and the Fuji S2 (which uses the ordinary analog Nikon protocol). In the Inon Z220, the SP signal from the camera (activated when the shutter is half-pressed) is used to operate the focusing light. Note that the strobe must be in Nikon mode for this functionality, i.e., the magnet must be in the 'N' hole. Ikelite overrides the SP function by placing a 3.3 kω resistor from SP to ground inside the Nikonos plug of its ICS5 to Nikonos TTL sync cables.. Hence only 4 wires are needed in an Ikelite TTL Nikonos cable. The Sea & Sea YS50TTL/N overrides the SP function by placing a 6.8kkΩ resistor from SP to ground inside the strobe. Hence 5 wires are needed in the cable. Sea & Sea YS-Duo series strobes (including the YS90A) and the YS60N will not assert Rdy until SP is asserted. SP in this case is used to determine whether a Nikonos TTL or a Sea & Sea TTL camera is connected, but this deviation from standard practice makes Duo strobes partially incompatible with the Nikonos IVa (The IVa must be switched to the X-sync speed manually). TTL quenching is still possible with SP disconnected, but the ready line always stays low. If you want to activate the Rdy function, connect a 100K resistor from X to SP (but note that the Rdy line voltage obtained is only about 2.1 V). Nikonos Speedlights and true clones feed the SP line to the strobe, and the strobe will not function in TTL mode if SP is left un-connected. In these cases the strobe can be fooled into thinking a TTL camera is present by connecting the strobe SP terminal to a positive supply via a resistor. A resistor in the range 22 kω - 47 kω from SP to Rdy is usually sufficient.

Ikelite TTL Interface The original Ikelite TTL flash interface is a subset of the Nikon interface with the SP function omitted. ICS5 bulkhead connector (strobe or housing) ICS5 plug on sync cable T- and B+6.5V On an early Ikelite TTL Substrobe (pre DS-series), the pin labeled T- is provided for compatibility with non-ttl cables. Such cables fire the strobe by shorting between X and T-, whereas a TTL cable fires the strobe by shorting between X and ground. For historical reasons (Ikelite solid-state triggering (SST) system), T- is not grounded, but connects via resistor to the gate of the tube-trigger thyristor. This means that the strobe can also be triggered by applying a currentlimited (~1 ma) positive pulse between T- and ground. On an Ikelite film SLR housing, the T- pin is not connected. The T- receptacles are likewise not connected (N/C) in a #4103 Ikelite to Ikelite TTL cable or in a #4104.6 Ikelite to Nikonos TTL cable. In the Ikelite DS-series interface, the T- function has been removed and replaced with a poweroutput connection (B+ 6.5 V) for the strobe-powered 4100.5 slave unit, the 4100.6 EV controller, and hot-shoe protocol conversion modules in digital camera housings. Hence Ikelite digital housings with TTL converters (e.g., Olympus TTL housings, Canon ettl housings) require a special 5-core sync cord #4103.51 (marked with a blue band), the extra wire being for the power supply connection. Note: Given that the T- function has disappeared, old 2-core manual Nikonos leads must not be used with DS-series Substrobes. SP: In an Ikelite film-slr housing, the SP function is disabled by connecting SP to ground via an 11 kω resistor (it varies) inside the hot-shoe connector. In non-ikelite SLR housings, the SP connection us usually brought out to a Nikonos bulkhead connector for compatibility with Nikon SB-series speedlights and clones. Ikelite wire colour codes Black = Gnd. White = X-contact, Green = Quench, Red = Ready, Grey = T- or B+ 6.5 V.

Sea & Sea Duo flash Interface This is a non-standard Nikonos interface, its behaviour being dictated by the additional requirements of the Motormarine II system: The Rdy line serves as the S (start integration) signal for the MM2 interface if SP is not asserted. Hence the strobe with a Nikonos V connector cannot switch a Nikonos IVa camera to X-sync mode (Nik III and IVa cameras do not connect SP). In the MM2 protocol, the Q line also serves to light the TTL OK LED in the camera viewfinder. Hence, if SP is not asserted, the Q line is only pulled-up when X is pulled low; or, after firing, when the green TTL OK light on the strobe is lit. In the MM2 protocol, the X line is only pulled up when the red Rdy light on the strobe is lit. Voltage on the X line is sensed to light the red Rdy LED in the camera viewfinder. If a 100 kω resistor is connected from X to SP, the Rdy line becomes active, the TTL OK function via the Q line is disabled, and the Q line is pulled up continuously rather than only when X is low. The Rdy line output voltage is sub-standard however (~2.1 V), and so protocol conversion modules powered from the Rdy line must be of very low voltage design if Sea & Sea compatibility is required.

Sea & Sea Motormarine II/EX (and SX-1000) Flash Interface The principal differences between the Sea & Sea MM2 and the Nikonos interface protocols are as follows: X: The flash ready function is provided by a positive voltage (+5.6 V nominal) appearing on the X terminal (i.e. the X-terminal is at 0V when the flash is not ready). S: Integration of light falling on the film is initiated when the flash unit places +3 V to +4 V on the S (start integration) terminal. This +3 V serves as the power supply for a 2903 comparator in the camera (see circuit below). Phototransistor (PT) current charges a capacitor, and when the capacitor voltage exceeds the ISO (Film DX coded) set-point, the comparator shorts the Q-line to ground. The leading edge of the S pulse momentarily turns on a transistor (Q4) which discharges the indicates ground. integration capacitor to initialise the system. Q: Two-way communication occurs on the Q line. The pull-up resistor for the Q input of the strobe is only powered while the X line is low. When X goes low, Q is pulled up (goes high). The camera then pulls the Q line low when integration is complete. The flash unit asserts a high on the Q line (via a resistor) for a few seconds if quenching is successful, to light the TTL OK LED in the camera viewfinder. D W Knight Cameras Underwater 2004. Converted to pdf: 2017-08-16