Sirocco Equipment Spares & Accessories

Similar documents
12V MINI AIR COMPRESSOR

Rack Mounted Products

12V Mini Air Compressor

Y:\Machine Manuals & Spare Parts Lists\PARTS BREAKDOWN\Commercial CW Gas\HD850WS Page 1

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

STRAIGHT CONNECTOR 5 80 N N N N N N N. Copyright 2016 by K-net All Rights Reserved

MODEL NUMBER: AS18-2 USER GUIDE

MODEL CALIBRATION GAS DELIVERY SYSTEM

Operating Instructions Part No

START UP MANUAL MADE IN USA REV US and Foreign patents and patents pending see

Digital Mini Compressor 12V

ATS430 turbidity sensor Retractable insertion assembly

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Instruction Manual for Configura Cushionair Portable Pump

P/N for 1.25" SDR P/N for 1.50" SDR P/N for 2.00" SDR

SILENTAIRE TECHNOLOGY

Model ASSEMBLY and OPERATING INSTRUCTIONS

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

INFLATABLE RESCUE RAFT 4 MANUAL

AIR COMPRESSOR 12V INSTRUCTION MANUAL SPECIFICATIONS. ozito.com.au AMC-3000 WHAT S IN THE BOX. Mini Compressor. Accessories x 3

Hydraulic hand test pump Models CPP700-H and CPP1000-H

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

Two-port seat valves

Pump On Demand. Skimmer System

JUMO dtrans p30 Pressure Transmitter

8-GALLON AIR-OPERATED OIL CHANGER

Automatic Control Unit. Controlmatic E. Type Series Booklet

User Manual MFCS TM -EZ

outdoor CoCkpit

TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection

COMPACT AIR COMPRESSOR MODEL NO OWNER S MANUAL

Replacing the Reverse Osmosis ( RO ) Membranes

How to Order. Applicable tube O.D. Thread. 8 ø8. ø10. ø12. ø16. Tube (Rod) Straight union. T Different dia. straight. F Female connector TX Male elbow

Connection Thread M, R(PT), Rc(PT) How to Order. Applicable tube O.D. Thread. 8 ø8. ø10. ø12. ø16. Tube (Rod)

Life Raft - Product Information

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

Design Features. General Description

80 Litre Suction Oil Drainer

Vertex VP Operation and Maintenance

Workshop Compressors CLASSIC Series

Type overview. R B2 en-gb subject to changes 1

RANGER PRO 12V AIR COMPRESSOR 560W RANGER PRO 12V AIR COMPRESSOR LPM MOTOR 150PSI MAX K13010 COILED AIRHOSE. ED1 July 17 POWERFUL DEFLATOR FUNCTION

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

(51) Int Cl.: A61B 1/00 ( )

Sanitary pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

COMPRESSOR REPLACEMENT PROCEDURE (R-134A)

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

Water Flow Regulators. The Leading Water Flow Regulator Worldwide. Essential Equipment For every injection and blow molding machine

SILENTAIRE TECHNOLOGY

abc OPERATING, INSTALLATION & MAINTENANCE MANUAL FOR MKIII CONSTANT PRESSURE CYLINDER

COMPRESSOR AND INFLATOR WITH TORCH

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Automatic Control Unit. Controlmatic E.2. Type Series Booklet

C MICRO-DUCT TUBE BLOWING MACHINE

WARRIOR 30 & 60 AIR COMPRESSOR OPERATING & MAINTENANCE INSTRUCTIONS

Damao Range. Single & Double Line Pressure Regulator - 4 or 8 bar

Junction Boxes Series 8118

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512

SCK01 AIR COMPRESSOR KIT WITH QUICK FITTINGS - SPRAY/BLOW/OIL GUN, TYRE INFLATOR & HOSE

-Filling rig Type TS150

COPPER TUBE COPPER AND BRASS FITTINGS SOFT DRAWN COPPER CAPILLARY COUPLER CAPILLARY NOMINAL OD WALL ROLL (M) R410A STOCK CODE CAA0020 1/

BSS 2 Bottle Sampling System. Instruction manual Version 1.8

Workshop Compressors CLASSIC Series

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

Air Mortar User Manual

Spare parts list ( ) Spare parts list HD 1.8/13 C Ed

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

4/2 way Pneumatic Solenoid Valve

2016 /17 Catalog. distributed exclusively throughout the U.S by

Airbrush Diaphragm Compressor AS06

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

Operation Manual Airbrush Compressor AS196A ARTICLE 34207

Code AWC20HP Air Compressor

[MSA The Safety Company] TURBO-FLO. Blowers. Replacement Parts. Accessories. Masks. Exploded Diagrams. safetyscope. Product Portfolio for FABA

HP-104 & HP-106 Tapping Machine OPERATIONS MANUAL

FX134, FX1234, FX3030 Problem and Solutions

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

Airtester HP for compressed air according to EN 12021

CAM & GROOVE COUPLINGS (for Liquid, Bulk and Chemical Transfer)

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

Soot Buster. Operating and Maintenance Instructions. Fire Tube Boiler Cleaner

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Soot Buster. Operating and Maintenance Instructions. M

1. Introduction Why use the Flow-Through Cell? Component Identification... 1

CLARK 200 Series Vortex Flow Transmitter Frequency Output, 1/4 to 1.0 Pipe Sizes, Rugged Molded PPA Construction

SEALED CONNECTORS FOR THE LIMIT SWITCHES

DIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG

HD 9/18-4 ST. Adaptation according to requirements thanks to retrofitting capability. Individual configurability saves investment costs

Upgradable balancing valves USV

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

AREA VALVE SERVICE UNITS

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

SIMPLAIR PIPING TOOL. JXT Company

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

Operating Instructions Part No

AIR COMPRESSOR 12 V DIRECT DRIVE MULTI-FUNCTION INSTRUCTION MANUAL. Model no

Transcription:

Sirocco Equipment Spares & Accessories Prysmian Part Number: See Individual Descriptions 2 & 4 Fibre Guide Part No. XBFSC00056 Used in the Sirocco Blowing Head when installing either 2 or 4 fibre units. 8 & 12 Fibre Guide Part No. XBFSC00057 Used in the Sirocco Blowing Head when installing either 8 or 12 fibre units. This must be used in conjunction with XBFSC00050. 8 & 12 Fibre Seal Part No. XBFSC00050 Used in the Sirocco Blowing Head when installing either 8 or 12 fibre units. This must be used in conjunction with XBFSC00057. Usage 1 per Blowing Head. Pack of 6 8 Fibre Brass Guide Part No. XBFSC00174 Used in the Sirocco Blowing Head when an 8 fibre unit. The wear characteristics of this guide are superior to that of XBFSC00057 & XBFSC00050. 5mm Duct Insert Part No. XBFSC00058 Used in the Sirocco Blowing Head when installing a fibre unit into a 5/3.5mm tube. Page 1 of 4

5mm Duct O Ring Part No. XBFSC00097 Used in the Sirocco Blowing Head when installing a fibre unit into a 5/3.5mm tube. This must be used in conjunction with XBFSC00058. Usage 1 per Blowing Head. Pack of 6. Drive Wheel Tyre Part No. XBFSC00059 Used in the Sirocco Blowing Head to drive the fibre unit into the tube. Idle Wheel Part No. XBFSC00060 Used in the Sirocco Blowing Head to drive the fibre unit into the tube. This wheel contains the magnets that operates the length counter. Blowing Head Control Unit Part No. XBFSC00109 This controls the speed and direction of the drive wheel within the blowing head. Blowing Head Air Connector Adapter Part No. XBFSC00051 This enables the Blowing Head to be connected directly to the compressor. It is used when working in a confined space. Page 2 of 4

Air Stone Part No. XBFSC00052 This is connected to the remote end of the installation route and is designed to collect any debris that may be blown through the tube. Pressure Indicator to 5mm Tube Connector Part No. XBFSC00053 When recovering an installed fibre unit this is used to connect the Pressure Indicator to the 5mm tube. Air Hose to 5mm Tube Connector Part No. XBFSC00054 When recovering an installed fibre unit this is used to connect either the Compressor Air Hose or the Compressor to the 5mm tube. Speed & Length Counter Part No. XBFSC00235 This indicator displays distance, speed and cumulative distance. This unit can only be fitted to a blowing head that has had one fitted previously. Airflow Gauge Part No. XBFSC00278 This gauge is used to measure the airflow through a BF tube. Page 3 of 4

24v dc Power Plug Part No. XBFSC00283 Used to connect the blowing head control unit to the power socket on The compressor.

Nominal Dimensions & Weights Item Description Item Code Length (mm) Max. Dia (mm) Weight (gms) 2 & 4 Fibre Guide XBFSC00056 155.0 8 & 12 Fibre Guide XBFSC00057 130.0 8 & 12 Fibre Seal lxbfsc00050 7.5 (dia) x 3.5 (h) 0.13 8 Fibre Brass Guide XBFSC00174 151.0 5mm Duct Insert XBFSC00058 75.0 127.0 5mm Duct O Ring XBFSC00097 11.0 (dia) x 3.0 (h) 0.25 Drive Wheel XBFSC00059 102 (dia) x 12.3 (h) 32.0 Idle Wheel XBFSC00060 50.0 (dia) x 13.0 (h) 52.0 Blowing Head Control Unit XBFSC00109 130 x 130 x 108 450.0 Blowing Head Air Connector Adaptor XBFSC00051 87.0 23.0 130.0 Air Stone XBFSC00052 77.0 25.0 39.0 Pressure Indicator To 5mm Tube Connector XBFSC00053 59.0 21.0 57.0 Air Hose To 5mm Tube Connector XBFSC00054 56.0 21.0 55.0 Speed & length Counter XBFSC00235 112 x 47 x 37 200.0 Airflow Gauge XBFSC00278 210 x 27 x 50 250.0 24v dc Power Plug XBFSC00283 135.0 50.0 150.0 Prysmian Telecom Cables & Systems UK Ltd, Chickenhall Lane, Bishopstoke, Hants SO50 6YU, UK Technical Enquiries +44 (0) 2380 608760 Fax Number +44 (0) 2380 608769 PRYSMIAN 2007. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian. Issue 03, July 2007 Ref: SI010 Page 4 of 4