ANALYSIS OF MALT WHISKEY

Similar documents
Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Copyrights: Restek Corporation

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

Carrier Gases in Capillary GC

Converting Helium Carrier Gas GC Methods Nitrogen and Hydrogen

Carrier Gases in Capillary GC

A Column-Flow Independent Configuration for QuickSwap. Application. Authors. Abstract. Introduction

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

Retention Time Locking: Concepts and Applications. Application

Comparative analysis of mass spectral matching for confident compound identification using the Advanced Electron Ionization source for GC-MS

Experiment GC : Analysis of BTEX by GC-FID

CHEMTRACE Fremont Blvd. Fremont, CA 94538, Tel: (510) Fax: (510)

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

Low-Pressure Retention Time Locking with the 7890A GC. Application. Authors. Abstract. Introduction HPI

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Impact of Air Leaks on the Productivity of GC and GC/MS Systems

Automated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek

May 1, By John Heim,Doug Staples

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

Sorbent Pens. For Next Generation Headspace Analysis

Rapid and Reliable Detection of Dissolved Gases in Water

Trace-Level Analysis of Metanephrines in Plasma by HILIC LC-MS/MS

Quantitative Analysis of Hydrocarbons by Gas Chromatography

Analysis of Benzenesulfonic Acid and P-Toluenesufonic Acid Esters in Genotox Monitoring using UPLC/UV-MS

GCMSD-Headspace Analysis SOP

GUIDE TO ULTRA-FAST HPLC. Quick Tips for Converting Conventional Reversed-Phase HPLC Separations to Ultra-Fast Separations

Automated Determination of Dissolved Gases in Water Anne Jurek

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Considerations and Best Practices for Maintaining Your Agilent GC s Split/Splitless Injection Port

Super-Clean Gas Filters from Restek

no peaks missing peaks too small peaks increasing retention decreasing retention

Extend the time window for the detection of low level anabolic androgenic steroids and their metabolites

Gas Chromatographic Applications of the Dielectric Barrier Discharge Detector

During today's webinar we're going to look at the following topics:

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

Office VOC Mixture Test Report

Multiple Gas#5 GC configuration Jan 2016

Addressing the World Shortage of Helium

CHM Gas Chromatography: Our Instrument Charles Taylor (r10)

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

Tips and Tricks of Injector Maintenance. Abby Folk Agilent GC Technical Support August 2009

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

A New GC/MS System Designed for Helium Carrier Gas Conservation

Agilent G3185B QuickSwap Accessory

3 Flow and Pressure Control

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Technical Procedure for Drug Chemistry Gas Chromatograph/Mass Spectrometry (GC-MS)

System Overview. TCD Detector temperature setpoint Regulator

Agilent G Rebuilt Electron Capture Detector

Zebron Gas Management

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013

Your local gas generation partner. Precision series Modular gas generation solution for GC.

APPLICATION NOTE. GC Integrated Permeation Device

Best Practice for Identifying Leaks in GC and GC/MS Systems

Development of DMS and Acetonitrile, and Formaldehyde gas standards. Gwi Suk Heo, Yong Doo Kim, Mi-Eon Kim, and Hyunjin Jin

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

5890II GC Standard Operating Procedure 9/2/2005

Products Designed to Solve Nagging GC Problems

The Preparation of Low Concentration Hydrogen Sulfide Standards Gulf Coast Conference September 12, 2002 Galveston, TX Paper 050,12:45 pm Moody F

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Varian 3300 Gas Chromatograph Abbreviated Operating Instructions

Determination of capsaicinoid profile of some peppers sold in Nigerian markets

TESTOSTERONE AND ESTERS* Latest Revision: June 23, 2005

Longterm Detection of Anabolic Steroid Metabolites in Urine

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

M/s. Thermo fisher Scientific

Agilent 7697A Headspace Sampler

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

Weiyi Zheng, Xiaoxia Dong, Evan Rogers, Jimmie C. Oxley, and James L. Smith*

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Simultaneous Determination of a Panel of 22 Steroids in Urine and Serum by SPE and LC-MS/MS

Operating Manual. AC OxyTracer Analyzer on 7890 GC Manual part number version 2011/1.0

Dionex IonPac AS19-4µm

3. Coupled Techniques in Thermal Analysis

Buck Scientific, Inc.

EMERGENCY PHONE: or (651) (24 hours)

GC Accessories Inlet Liners Sky Inlet Liners Other Deactivations Inlet Liner Accessories

NCASI METHOD IM/CAN/WP IMPINGER/CANISTER SOURCE SAMPLING METHOD FOR SELECTED HAPS AND OTHER COMPOUNDS AT WOOD PRODUCTS FACILITIES

Space product assurance

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

The instrument should have a mass range from 2 to 2000 m/z or better Interface

Operation of the Perkin Elmer TGA-GC/MS

Extended Application Note

Quick Reference Guide. OPTIC 3 - PTV on Shimadzu GC-2010 Gas Chromatograph

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Improved detection and monitoring of beetle pests in stored grain through use of a multi-species lure (LK0929)

Gas chromatographic determination of 1,4-dioxane at the

TANK LINING RESISTANCE GUIDE I-19

DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

instrumentation Pulsed Discharge Detectors Non-Radioactive, Multiple Mode Electron Capture / Helium Photoionization

Ultimate Performance in Gas Chromatography

SUPPORTING INFORMATION

Recent Advances to Ensure Simple, Leak Free GC Column Connections. Ken Lynam R&D/Application Chemist Agilent Consumables and Supplies Division

H 2. Sensor Series Take no risk! Install a Hydrogen Sensor in your Gaschromatograph

POB 1778 Greer, SC West Poinsett Street Greer, SC Ph: Fax:

Transcription:

Optimizing the Capillary GC Separation of Acids, Esters, and Other Flavor Components in Distilled Liquor Products REBECCA E. WITTRIG 1, KEVIN MACNAMARA 2, & NEIL MOSESMAN 1 ( 1 Restek Corporation, 110 Benner Circle, Bellefonte, PA 16823 2 Irish Distillers Ltd, Bow Street Distillery, Smithfield, Dublin 7, Ireland) ABSTRACT Distilled liquor products contain a wide range of volatile and non-volatile compounds in an ethanol/water matrix. The most abundant fusel alcohols and esters can be determined by simple split injection, which also minimizes the amount of matrix ethanol and water transferred to the column. However, many additional trace fatty acids and their esters, which often are used to indicate product quality in alcoholic beverages such as whiskey and rum, cannot be determined by this approach. Capillary gas chromatography is a powerful tool for the analysis of these compounds, but the large ranges in volatilities and acidities can make it difficult to quantitate all of the components in a single chromatographic separation. In addition, because the concentrations can vary widely, splitless injection techniques with some type of preconcentration step often are necessary. One example of this is a large volume injection with a venting step, which can be optimized to remove most of the matrix ethanol and water. Using a bonded polyethylene glycol (PEG) capillary column, flavor compounds in distilled liquor products can be quantitated in a single splitless injection. The Stabilwax -DA column was selected for this application. To improve peak shape and reproducibility of acidic components on this column, an acidic functionality has been added to the backbone of the PEG stationary phase. This results in less adsorption of acidic components and significantly less peak tailing. In addition, the chromatographic separation of these compounds has been optimized to allow for the rapid analysis of fatty acids, esters, and other trace level components. An optimized configuration of 30m, 0.18mm ID, 0.18µm allows for significantly reduced analysis times. An interesting application is in the determination of flavor compounds in alcoholic beverages such as malt whiskeys and grappas. PROCEDURE To optimize the chromatographic conditions for this analysis, a test mixture containing acids, esters, and flavor compounds typically found in alcoholic beverages was prepared (see Figure 1). A computer modeling program, ezgc, was used to optimize the column configuration, temperature program, and inlet flow for this system. Based on this, an optimized configuration of 30m, 0.18mm ID, 0.18µm was developed. To test the applicability of this column in these dimensions, the critical pair of caproic acid and ethyl laurate was studied. These components can be very difficult to resolve on standard Carbowax -type columns. This is especially true if peak tailing or broadening occurs, or if one component is present at a significantly higher concentration. The Stabilwax -DA column achieves baseline resolution of these two compounds within a reasonable analysis time of 13 minutes (Figure 2). Because alcoholic beverage samples often are injected via splitless mode, the stability of the Stabilwax -DA column when exposed to aqueous injections is important. We verified stability by performing a splitless injection of the alcoholic beverage test mix, followed by five 1µL injections of water. This process was repeated 10 times, followed by a final injection of the test mix. The final test mix injection can be seen in (Figure 3). Even after repeated splitless injections of 100% water, very little degradation occurs in the peak shapes of the test mix components. Over the course of the study, the variation in the peak retention times was 0.08-0.22% RSD. This includes the polar free fatty acids, which can be difficult to analyze under ideal conditions. The excellent stability of this stationary phase is proven by the reproducibility of the retention times over the course of the water stability study. ANALYSIS OF MALT WHISKEY Whiskey is distilled from a fermented mash of grain, such as corn, rye, barley, or wheat. Aging of the whiskey takes place within barrels or casks, and it is during the aging process that whiskey obtains its characteristic color, flavor, and aroma. Factors that influence the flavor of the final product include the characteristics of the grain, recipes, and how the whiskey is distilled. The flavor profile of a whisky contains hundreds of compounds, including fatty acids, esters, alcohols, and aldehydes. An example of a malt whiskey profile, as determined by GC/MS, can be seen in (Figure 4). 1

ANALYSIS OF GRAPPA Grappa is the spirit produced from grape marc, or the skins of the grapes after they have been pressed during wine production. This grape marc is fermented and distilled either directly or by water vapor. Grappas generally do not require the same amount of aging as other alcoholic beverages, although, for example, Italian law requires at least six months of aging. Flavored grappas can be produced by adding ingredients such as herbs and fruits. The flavor profile of grappas contains hundreds of compounds at a wide range of concentrations. The chromatographic profile of a sample of grappa can be seen in (Figure 5). SUMMARY The Stabilwax -DA column is an excellent choice for the analysis of acids, esters, and other flavor components in alcoholic beverage products. This highly stable column has been optimized for the analysis of acidic compounds, making it possible to analyze a wide range of compounds in a single injection. In addition, the column configuration shown in this article allows fast, efficient analysis of complex products such as malt whiskeys and grappas. Large volume injection techniques allow for the analysis of a wide range of concentrations in a single run. As shown in this paper, analytes at higher concentrations such as alcohols and esters and trace level flavor compounds can be analyzed simultaneously. Large volume injections on the order of 10-100µL can be used for analyses of this type. The venting step during the large volume injection can be optimized to remove most of the ethanol/water matrix. Since some water will enter the chromatographic column, a stabilized phase such as the Stabilwax -DA should be used. Figure #1 Alcoholic beverage test mixture on the Stabilwax-DA capillary column. Peak List Conc. (ppm) 1. ethyl octanoate 100 2. acetic acid 100 3. propionic acid 100 4. isobutyric acid 100 5. decanol 3 50 6. ethyl decanoate 50 7. ethyl laurate 50 8. cis-lactone 100 9. 2-phenylethanol 50 10. trans-lactone 100 11. methyl myristate 50 12. ethyl myristate 50 13. octanoic acid 100 14. ethyl palmitate 50 15. decanoic acid 100 16. dodecanoic acid 100 17. vanillin 100 GC_FF00500 Stabilwax -DA 30m, 0.18mm ID, 0.18µm (cat.# 550752) 1µL splitless (hold 0.5 min.) at conc. shown in peak list, in ethyl acetate, 4mm ID splitless liner w/wool (cat.# 20814-202.1) Inj. temp.: 240 C Carrier gas: hydrogen Make-up gas: nitrogen Linear velocity: 28psi @ 240 C Oven temp.: 70 C to 240 C at 12 C/min. (hold 3 min.) Det.: FID 2

Figure #2 Complete resolution of caproic acid and ethyl laurate can be achieved in 13 minutes. 1 Peak List Conc. (ppm) 1. caproic acid 100 2. ethyl laurate 100 2 GC_FF00525 Stabilwax -DA 30m, 0.18mm ID, 0.18µm (cat.# 550752) 1µL splitless (hold 0.5 min.) at conc. shown in peak list, in ethyl acetate, 4mm ID splitless liner w/wool (cat.# 20814-202.1) Inj. temp.: 240 C Carrier gas: hydrogen Make-up gas: nitrogen Linear velocity: 28psi @ 240 C Oven temp.: 80 C to 230 C at 5 C/min. Det.: FID Figure #3 Injection of the test mixture following fifty 1µL injections of water. 1 2 3 5 4 6 11 9 7 12 8 10 0 2 4 6 8 10 12 14 16 GC_FF00526 13 14 15 16 17 min. Peak List Conc. (ppm) 1. ethyl octanoate 100 2. acetic acid 100 3. propionic acid 100 4. isobutyric acid 100 5. decanol 3 50 6. ethyl decanoate 50 7. ethyl laurate 50 8. cis-lactone 100 9. 2-phenylethanol 50 10. trans-lactone 100 11. methyl myristate 50 12. ethyl myristate 50 13. octanoic acid 100 14. ethyl palmitate 50 15. decanoic acid 100 16. dodecanoic acid 100 17. vanillin 100 Stabilwax -DA 30m, 0.18mm ID, 0.18µm (cat.# 550752) 1µL splitless (hold 0.5 min.) at conc. shown in peak list, in ethyl acetate, 4mm ID splitless liner w/wool (cat.# 20814-202.1) Inj. temp.: 240 C Carrier gas: hydrogen Make-up gas: nitrogen Linear velocity: 28psi @ 240 C Oven temp.: 70 C to 240 C at 12 C/min. (hold 3 min.) Det.: FID 3

Figure #4 Flavor profile of malt whiskey by GC/MS using a large volume injection technique and a Stabilwax -DA capillary column. 1. acetic acid 2. ethyl decanoate 3. ethyl dodecanoate 4. 2-phenylethanol 5. octanoic acid 6. decanoic acid 7. dodecanoic acid 8. vanillin 9. hexadecanoic acid 10. syringealdehyde GC_FF00554 GC_FF00555 GC_FF00556 GC_FF00557 4

Figure #4 (cont.) GC_FF00555 GC_FF00556 1. ethyl octanoate 2. acetic acid 3. siloxane 4. 1-hydroxy-2,3-butadione 5. 1-hydroxy-2-propanone acetate 6. furfural 7. formic acid 8. propionic acid 9. isobutyric acid 10. dimethyl sulfoxide 11. 5-methyl furfural 12. methyl decanoate + unknown 13. butyric acid 14. siloxane 15. ethyl decanoate 16. furfuryl alcohol + isoamyl octanoate 17. isovaleric acid + 2-methylbutyric acid 18. diethyl succinate 19. 3-methyl-2(5H)-furanone (possible) 20. valeric acid 21. ethyl undecanoate 22. isobutyl decanoate 23. 2(5H)-furanone 24. unknown 25. diethyl pentanedioate 1. di(ethyleneglycol) butyl ether 2. siloxane 3. methyl dodecanoate 4. phenylethyl acetate 5. methylcyclopentenolone 6. hexanoic acid 7. ethyl dodecanoate 8. isoamyl decanoate + guaiacol 9. dodecyl acetate (possible) 10. whiskey lactone (1) 11. 2-phenylethanol 12. heptanoic acid 13. siloxane 14. dimethoxybenzene or 4-methylguaiacol 15. whiskey lactone (2) 16. dodecanol 17. unknown 18. phenol 19. methyl tetradecanoate 20. nerolidol 21. diethyl malate 22. ethyl tetradecanoate 23. octanoic acid 24. unknown 25. p-cresol 26. siloxane 27. diethyl octanedioate 28. monomethyl succinate 29. 3,5-dimethyl-2,4(5H) furandione 5

Figure #4 (cont.) GC_FF00557 1. nonanoic acid 2. diethyl 2-hydroxyglutarate 3 unknown 4. tetradecanol 5. 4-vinylguaiacol 6. diethyl nonanedioate 7. methyl hexadecanoate 8. ethyl γ-lactone 2-hydroxyglutarate 9. ethyl hexadecanoate 10. decanoic acid 11. ethyl 9-hexadecanoate 12. triacosan 13. unknown 14. phthalide 15. diethylphthalate 16. hexadecanol 17. 4-hydroxycinnamic acid (decomp.) 18. methyl stearate 19. benzoic acid 20. methyl 8-octadecenoate 21. ethyl stearate 22. dodecanoic acid 23. hydroxymethylfurfural 24. ethyl linoleate 25. 4-allyl-2,6-dimethoxyphenol 26. diisobutyl phthalate 27. vanillin 28. sinapic acid (decomp.) 29. 2-phenylethyl decanoate + 2 unknowns 30. 2-propenyl-2,6-dimethoxyphenol 31. ethyl vanillate 32. acetovanillone 33. vanillin methyl ketone 34. tetradecanoic acid 35. ethyl homovanillate 36. propiovanillone 37. fatty acid ester 38. (similar to 4-allyl-2,6-dimethoxyphenol) 39. unknown Figure 4 conditions: Stabilwax -DA 30m, 0.18mm ID, 0.18µm (cat.# 550752) Std. conc.: Gerstel CIS Injector: Helium vent flow: Carrier gas: Linear velocity: Oven temp.: Det.: Transfer line temp.: 240 C Quadrupole temp.: 150 C MS source temp.: 230 C Scan range: Ionization: Mode: 10µL large volume injection (splitless), at 10µL/min. neat 35 C (hold 2 min.), to 300 C @ 10 C/sec. (hold 5 min.) 600mL/min with 1.8 min. vent end time helium 45cm/sec. 60 C (hold 2 min.) to 100 C @ 20 C/min., to 240 C @ 5 C/min. (hold 10 min.) MSD 30 400amu 70eV EI Chromatogram courtesy of Kevin MacNamara, Ph.D., Irish Distilleries, Ltd. 6

Figure #5 Flavor profile of grappa by GC/MS using a large volume injection technique and a Stabilwax -DA capillary column. 1. acetic acid 2. ethyl decanoate 3. ethyl dodecanoate 4. 2-phenylethanol 5. octanoic acid 6. decanoic acid 7. dodecanoic acid 8. dibutyl phthalate GC_FF00559 GC_FF00560 7

Figure #5 (cont.) GC_FF00559 GC_FF00560 1. ethyl octanoate 2. acetic acid 3. siloxane 4. furfural 5. propionic acid 6. benzaldehyde + linalool 7. isobutyric acid 8. methyl decanoate 9. butyric acid 10. siloxane 11. ethyl decanoate 12. isoamyl octanoate 13. isovaleric acid + 2-methylbutyric acid 14. susquiterpene (shoulder) 15. diethyl succinate 16. ethyl 9-decenoate 17. α-terpineol 1. (possible 3-methyl-2(5H)- furanone) 2. valeric acid + susquiterpene 3. linalool oxide 4. susquiterpene 5. isobutyl decanoate 6. 1-decanol 7. β-citronellol 8. susquiterpene 9. methyl salicylate + unknown 10. siloxane 11. methyl dodecanoate 12. hexyl octanoate + 2-tridecanone 13. trans-2, trans-4-decadienol 14. 2-phenylethyl acetate 15. hexanoic acid 16. ethyl dodecanoate 17. unknown 18. isoamyl decanoate 19. benzyl alcohol 20. unknown 21. 2-phenylethanol 22. 2-ethylhexanoic acid 23. heptanoic acid 24. dodecanol 25. phenol 26. γ-nonalactone 27. octanoic acid 28. siloxane 29. ethyl cinnamate 30. decalactone + unknown 31. nonanoic acid 32. phenylethyl hexanoate 33. diethyl nonanedioate 34. methyl hexadecanoate 35. dimethyl naphthalene 36. ethyl hexadecanoate 37. decanoic acid 38. ethyl 9-hexadecenoate 39. geranic acid 40. phenylethyl octanoate 41. dodecanoic acid 42. ethyl linoleate 43. diisobutyl phthalate 44. ethyl linolenate 45. phenylethyl decanoate Figure 5 conditions: Stabilwax -DA 30m, 0.18mm ID, 0.18µm (cat.# 550752) Std. conc.: Gerstel CIS Injector: Helium vent flow: Carrier gas: Linear velocity: Oven temp.: 10µL large volume injection (splitless), at 10µL/min. neat 35 C (hold 2 min.), to 300 C @ 10 C/sec. (hold 5 min.) 600mL/min with 1.8 min. vent end time helium 45cm/sec. 60 C (hold 2 min.) to 100 C @ 20 C/min., to 240 C @ 5 C/min. (hold 10 min.) Det.: MSD Transfer line temp.: 240 C Quadrupole temp.: 150 C MS source temp.: 230 C Scan range: 30 400amu Ionization: 70eV Mode: EI Chromatogram courtesy of Kevin MacNamara, Ph.D., Irish Distilleries, Ltd. 8