Quiz for Module 2: Aquarius Training (Rev. 1) Lesson 1: Introduction to Aquarius

Similar documents
Module 2: Aquarius Training

AQUARIUS Continuous Renal Replacement Therapy Competency

Troubleshooting Guide Aquarius

AQUARIUS Continuous Renal Replacement Therapy with Regional Citrate Anticoagulation (RCA) Competency

Contacts. Quick Start Guide

HAEMOFILTRATION GUIDELINES

CRRT with Prismaflex LEADS TO More Flexibility, Ease of Use and Safety

AQUADEX FLEXFLOW SYSTEM QUICK REFERENCE GUIDE

INTERNATIONAL MARKETING. 61, avenue Tony Garnier Lyon France Tel.: 33 (0) Fax: 33 (0)

MANITOBA RENAL PROGRAM

Liberty PDx Cycler Handi-Guide

Liberty Cycler Handi-Guide

- Repeat calibration until desired results are reached otherwise set SW2 and SW1-8 open.

Indications for Use: Caution: Note:

Liberty Handi-Guide. A Patient s Reference to the Most Commonly Asked Questions About the Liberty Cycler

Introduction. Medley TM Medication Safety System. Alaris Medical Systems

Liberty Handi-Guide A Patient s Reference to the Most Commonly Asked Questions About the Liberty Cycler

Handi-Guide A Patient s Reference to the Most Commonly Asked Questions About the Liberty Select Cycler

CircuFlow Quick Setup Guide

Blood Pressure Monitoring: Arterial Line

New. The high security connection

Negative Pressure Wound Therapy

1.060 Set-Up and Priming of the Bypass Circuit. Perfusion Technology Department. Perfusionists

Alaris Pump module FAQs

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

MANITOBA RENAL PROGRAM

extricare 3600 Operating Manual

A complete family of Pediatric Perfusion Systems

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

Heart/Lung Perfusion Packs INSTRUCTIONS FOR USE

Reverse Osmosis System Installation Guide and Operation Manual.

Nimbus II PainPRO Ambulatory Infusion Pump

Bloodlines, Tubing Systems, Accessories

Alfred ECMO Circuit Priming and Storage Guide

Compatible Baxter IV Sets

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

User Manual Article number: I

2008T Hemodialysis Machine with CLiC Device Training Guide

Shared Haemodialysis Care Handbook. Name Hospital number: Shared HD Care Nurse: Date: Machine type: Dialysis Unit:

Liberty Cycler User s Guide

EASYPUMP II THE FLEXIBLE SOLUTION FOR SHORT AND LONG TERM INFUSION THERAPIES

Peristaltic Infusion Pump AP 31P OPERATOR S MANUAL

Nimbus II PainPRO Ambulatory Infusion Pump

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

CADD-Micro. Model 5900 Operator s Manual. Note: Colors are Black and Cyan (as second color) Deltec. Ambulatory Infusion Pump

1 Introduction on the appearance, configuration and function

IV IV Training Guide

S/5 Aespire. Quick Reference Guide

100 Series Dialyzer Reprocessing System MODEL RS8310 MODEL RS SERIES S/N S 1,000 - UP

Liberty PDx Cycler User s Guide

Liberty Select Cycler User s Guide

Operation of Oxylog 3000 ventilator

MyoSure Setup Simplified

NEXUS TKO. Specialty Neonatal/Pediatric. Safety Infusion Sets. Blood Reflux Protection 24/7! Anti-Reflux Technology Provides

InFlow Modular perfusion bioreactor

The Univentor 1250 Anaesthesia Unit

Patient Home Care Information

Instructions for Use

Redesign - ATMOS S 201 Thorax. Digital thoracic drainage systems. ATMOS Thorax MOBILITY SAFETY COMFORT FLEXIBILITY

Innovation at its best

CCT-7320/ROC-2313 Reverse Osmosis Controller

Chest Drainage Systems for Cardiac & Thoracic Surgery. Including portable suction with Digital Air Leak Monitoring

Using the Akta Prime plus October 22, 2012

Haemodialysis. Bloodlines, Tubing Systems, Accessories Product Range. Product name / Headline Subline

Contents. 6. Infusion Mode...10

BiPAP A30. Set-up guide. Connection to oximetry. Getting started. Guidelines for ventilation set-up. Main screen. Menus.

ila ACTIVVE SYSTEM PLATFORM

WARNING: All medications should be closely monitored to detect any alterations in the effective concentration due to the ultrafiltration process.

Checking a Breathing System

FAULT CODE TROUBLESHOOTING INDEX

OPERATOR S MANUAL. P/N GB Rev. 008

A4s Operation Manual

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

WARNING FOR YOUR SAFETY

THE UNIVENTOR 400 ANAESTHESIA UNIT

Digital Display large color coded LED display is easy to read precise measuring shows actual cuff pressure

NOTICE. Issued: February 12, 2010 AO# Dundas Street West, Oakville, ON CANADA Phone: (905) Fax: (905)

Volumat Agilia _Volumat_Presentation_customer.ppt

HEALTH SERVICES CODE A.6 CATEGORY: RN - SNP

Hemoglobin Reference Failure Troubleshooting

Ventilator Training Module

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

C O L O G Y. New. g u O N. l o t a C a. The high security connection

AKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by:

Micro-X Dialyzer Reprocessing Concentrate

CDI System 500. Blood Parameter Monitoring System. Continuous blood parameter monitoring for improved blood gas management

Company building TOTAL SOLUTION OF AIR COMPRESSION THERAPY SYSTEM. New second factory. Main office & Factory Stories house

Roller AC Servo System

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Accutorr. Quick Reference Guide

Blood Parameter Monitoring System 550

Xcela Hybrid PICC. Clinician Reference Tool

Device overview. 6 Breathing circuit connection. Note: When the remote control foot pedal is connected, the manual switch is disabled.

1020 Industrial Drive, Orlinda, TN fax

Armfield Distillation Column Operation Guidelines

AUTOVENT 4000 VENTILATOR

HemoCue Hb Procedure Template

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr


User manual CF8-D/W-IN

Transcription:

Quiz for Module 2: Aquarius Training (Rev. 1) Lesson 1: Introduction to Aquarius page 1 of 2 Name: Date: Score: Instructor: Location: Please circle the correct answers: 1. Select the answer(s) that represent design concepts used for Aquarius: A. Patient safety and innovation B. Flexibility and simplicity C. Consistent messaging 2. Select the answer that BEST describes the purpose of the Main selector button on Aquarius: A. It allows access to the screen B. It is used in conjunction with a touch screen to program parameters C. It is used to select and confirm different functions and to modify treatment parameters 3. Select the answer that is NOT correct regarding Are you sure messages on Aquarius: A. The default selection is YES B. The default selection is NO C. The Are you sure is in a red message box D. The operator must acknowledge and confirm the choice 4. Aquarius has three status lights at the top of the monitor. Select the answer that BEST describes what is happening when the green and yellow lights are flashing: A. Aquarius is in Preparation mode B. Heater self-test is still running C. System test is running D. A bag change is required 5. Aquarius has three status lights at the top of the monitor. Select the answer that describes what is happening when ONLY the green status light is illuminated. A. Aquarius is in Preparation mode B. Aquarius is in Treatment mode C. System test is running D. An alarm has occurred

Quiz for Module 2: Lesson 1 cont. page 2 of 2 6. Aquarius has three status lights at the top of the monitor. Select the answer that describes what is happening when the green and yellow status lights are illuminated and solid: A. Aquarius is in Preparation mode B. Aquarius is in Recirculation or Connection mode C. A bag change is required 7. Aquarius allows the operator to mute alarms using the Mute function key. Alarms can be muted for: A. 5 minutes B. 3 minutes C. 2 minutes D. 1 minute 8. The Blood pump function key is used to immediately stop the blood pump. Select the answer that also describes a function(s) of the Blood pump function key: A. Green LED is solid when the Blood pump is running B. This key is used to reset alarms C. Pressing the Blood pump function key during treatment will also stop the fluid pumps 9. Select the answer that BEST describes the purpose of the Balance Start/Stop key? A. Controls the weight on the scales B. Monitors the weight on the scales C. Starts and stops the substitution, dialysate and anticoagulant pumps D. Starts and stops the substitution, dialysate and filtrate pumps 10. The Clamp function key is used to manage air detection in the Aquarius circuit. Select the answer that describes the features of the Clamp key during an Air detected alarm A. The LED is the key is red when air is detected in the circuit B. The LED will flash green when the air is removed form the circuit C. Pressing the Clamp key will permit a temporary opening of the line clamp, but will not allow the blood pump to start Edwards Lifesciences S.A. Ch. du Glapin 6 1162 Saint-Prex Switzerland +41 21 823 4300 www.edwards.com Edwards Lifesciences, Aquarius and Aqualine are trademarks of Edwards Lifesciences Corporation.

Quiz for Module 2: Aquarius Training (Rev. 1) Lesson 2: Preparing Aquarius page 1 of 3 Name: Date: Score: Instructor: Location: Please circle the correct answers: 1. Select the answer that BEST describes the Aquarius system test A. The test is conducted at the start of treatment and intermittently throughout the treatment B. The test is not mandatory C. The test takes approximately four minutes and must be completed before bags, tubings or solutions are placed on the machine 2. The blood flow rates available with Aquarius during a regular treatment are A. 50 400 ml/min B. 10 200 ml/min C. 30-450 ml/min D. 20 400 ml/min 3. On the Aqualine each pump segment has a colored indicator that determines which pump it belongs to. What is the correct position for these indicators? A. The top of each pump B. The bottom of each pump C. All of the above D. None of the above 4. Select the answer(s) that BEST apply to the Automatic degassing chamber (ADU) located on the right front panel of the Aquarius: A. The ADU is under the green pumps B. The line with the hydrophobic filter attaches to the ADU sensor with the clamp closed C. The line with the hydrophobic filter attaches to the ADU sensor with the clamp open D. A and C

Quiz for Module 2: Lesson 2 cont. page 2 of 3 5. Aquarius has four pressure sensors located on the front of the machine. Select the answer that identifies these sensors: A. Pre-filter, Arterial, Venous, Filtrate B. Pre-filter, Access, Venous, Filtrate C. Filter, Arterial, Return, Filtrate D. Pre-filter, Access, Return, Filtrate 6. Aquarius primes the circuit with the blood pump running counter clockwise (backwards). Select the answer that correctly indicate the connection of the blood line to the priming solution A. Red end of blood line to priming solution B. Blue end of blood line to priming solution C. Both red and blue ends are connected to the priming solution D. The blood line is not connected to the priming solution 7. When attaching the Aqualine to the hemofilter the filtrate line is ALWAYS attached to A. Red top port of the hemofilter B. Luer-lock side port near the top of the hemofilter C. Luer-lock side port near the bottom of the hemofilter D. Blue bottom port of the hemofilter. 8. When using Aquarius, the free line connection determines the type of therapy performed. Select the answer that describes the correct connection for the free line during CVVHD and CVVHDF: A. Connected to the dialysate port near the bottom of the hemofilter B. Connected to the filtrate port near the top of the hemofilter C. Connected to the luer-lock port located on the Aqualine just above the hemofilter D. None of the above 9. Select the answer that correctly describes the choices in the Prepare anticoagulant screen during Aquarius set up: A. Select volume in syringe B. Prime anticoagulant line C. Program Heparin

Quiz for Module 2: Lesson 2 cont. page 3 of 3 10. Priming Aquarius takes approximately nine minutes. At the end of priming the operator has two choices, Next or Reprime. After the operator confirms Next, select the answer that correctly identifies the next step. A. Go to programming B. Go to connection C. Go to Clamp and Pressure test D. Go to recirculation 11. Aquarius allows the operator the opportunity to reprime the circuit. Choose the correct steps to reprime if there is a need to flush another 800 ml of priming solution through the circuit. Hang a new bag of priming solution then: A. Select Next and continue B. Select Reprime and Filtrate Line C. Select Reprime and Blood circuit D. Select Post-dilution and continue Edwards Lifesciences S.A. Ch. du Glapin 6 1162 Saint-Prex Switzerland +41 21 823 4300 www.edwards.com Edwards Lifesciences, Aquarius and Aqualine are trademarks of Edwards Lifesciences Corporation.

Quiz for Module 2: Aquarius Training (Rev. 1) Lesson 3: Treatment Mode page 1 of 2 Name: Date: Score: Instructor: Location: Please circle the correct answers: 1. Select the answer that indicates the DEFAULT highlighted parameter on the Treatment screen: A. Heparin B. Blood flow C. Go to programming D. Help 2. The Aquarius Treatment screen provides information regarding several therapy parameters. Select the answer that is NOT part of the information displayed on this screen: A. Blood flow rate and access pressure B. Fluid loss and substitution/dialysate totals C. Options and Help D. UF variation and filtration fraction 3. Selecting and confirming the More choice from the Treatment screen will allow the operator to: A. Program and make changes B. View additional parameters with no ability to make changes C. Access Help and History screens D. Change therapy 4. Select the answer that BEST describes the Aquarius History screens: A. Available from Options screen or directly from Help B. Available in graphic and list format C. Available for three consecutive treatments 5. The patient may be disconnected from Aquarius by selecting and confirming Recirculation or End treatment from the Options screen. Select the answer that BEST describes when Recircultion might be selected during a treatment: A. The circuit has clotted and the operator needs to change the complete circuit B. The patient has been receiving treatment for a few hours and needs to go for an MRI C. The patient s renal function is improving and the physician has written an order to discontinue therapy D. The physician has written an order to change the therapy from CVVH to CVVHD.

Quiz for Module 2: Lesson 3 cont. page 2 of 2 6. The patient may be disconnected from Aquarius by selecting and confirming Recirculation or End treatment from the Options screen. Select the answer that BEST describes when End Treatment might be selected during a treatment. A. The circuit has partially clotted and the operator needs to change only the hemofilter B. The patient has been receiving treatment for a few hours and needs to go for an MRI C. The patient s renal function is improving and the physician has written an order to discontinue therapy D. The physician has written an order to change the therapy from CVVH to CVVHD. 7. Select the answer that BEST describes what happens when the operator selects and confirms End Treatment from the Options screen A. This selection terminates the treatment and leads to disconnection B. This selection starts a temporary disconnection C. This selsctioin allows the operator to return to the Treatment screen 8. Select the answer that BEST describes the procedure for turning off Aquarius at the end of a treatment: A. Remove the solution bags and confirm Aquarius OFF B. Confirm Aquarius OFF then remove tubing set and solutions C. Completely remove the tubing set and solutions, then confirm Aquarius OFF D. It doesn t matter how it s done. 9. Certain events during a treatment may cause excessive pressure to build inside the blood circuit. If excessive pressures are present at the end of any treatment, Aquarius displays a message indicating pressures inside the circuit exceed 400 mmhg. Select the answer that BEST describes the correct procedure for removal of the tubing set: A. Select Aquarius OFF and remove the tubing set B. Use a syringe to decrease the pressure before removing the tubing set, then turn Aquarius OFF C. Clamp all the lines and remove the tubing set Edwards Lifesciences S.A. Ch. du Glapin 6 1162 Saint-Prex Switzerland +41 21 823 4300 www.edwards.com Edwards Lifesciences, Aquarius and Aqualine are trademarks of Edwards Lifesciences Corporation.

Quiz for Module 2: Aquarius Training (Rev. 1) Lesson 4: Pressures, Alarms & Fluid Balance page 1 of 3 Name: Date: Score: Instructor: Location: Please circle the correct answers: 1. Aquarius uses four pressure sensors to monitor and control the system. Pressures from the blood and fluid sides of the circuit are used in combination to manage the treatment safely and effectively. Select the answer that BEST describe the pressures used to monitor only the blood side of the circuit: A. Filtrate, Transmembrane pressure (TMP), Pressure Drop (PD) and Access B. Transmembrane pressure (TMP), Pressure Drop (PD), Access and Return C. Access, Return, Pressure Drop (PD), and Pre-filter D. Pre-filter, Transmembrane pressure (TMP), Access and Filtrate 2. Select the answer that BEST describe features that apply to the Access pressure on Aquarius: A. Monitors the negative pressure generated to remove blood from the patient B. The pressure may be affected by the patient s access catheter and the blood flow rate C. The pressure is displayed on the Treatment screen 3. Select the answer that BEST describes the Filtrate pressure on Aquarius: A. Monitors a pressure on the blood side of the circuit B. Blood flow rates and fluid flow rates do not affect this pressure C. Monitors both positive and negative pressure in the filtrate compartment of the hemofilter D. Clotting in the hemofilter does not affect this pressure 4. Transmembrane pressure (TMP) is calculated using Return pressure, Access pressure and Filtrate pressure. The primary role of TMP is to provide information on the condition of the hemofilter throughout the therapy. TMP is displayed on the: A. End treatment screen B. Treatment screen C. Options screen D. More screen

Quiz for Module 2: Lesson 4 cont. page 2 of 3 5. Aquarius safety mode is determined by the nature of occurring alarms. Select the answer that correctly identifies the types of alarms that occur: A. Alarms in the blood circuit B. Alarms in the filtrate/dialysate circuit C. System errors 6. Select the answer that BEST describes what happens during an Aquarius blood circuit alarm: A. A visual and audible alarm is generated, all pumps stop and the line clamp closes B. An audible alarm is generated and the blood pump stops C. An audible alarm is generated and the fluid pumps stop D. Only an audible alarm is generated 7. Messages related to alarm types are displayed in color-coded message boxes and are also indicated by illumination of status lights on the display monitor. Select the answer that BEST describe these parameters during a blood circuit alarm A. Message box is red and the red and yellow status lights are illuminated B. Message box is yellow and the red and yellow status lights are illuminated C. Message box is yellow and yellow status light is illuminated D. Message box is yellow and red status light is illuminated 8. Select the answer that correctly identifies characteristics of alarms on Aquarius: A. Alarms may be silenced for two minutes using the Mute key B. Blood circuit and System alarms are cleared by pressing the Blood Pump key C. Fluid circuit alarms are cleared by pressing the Balance Stop/Start key 9. Aquarius uses a system of scales and pumps to ensure accuracy in patient fluid removal. Select the answer that correctly identifies when a balance alarm occurs if the treatment is performed using a regular Aqualine. A. 25 milliliters B. 20 milliliters C. 60 milliliters D. 50 milliliters

Quiz for Module 2: Lesson 4 cont. page 3 of 3 10. Aquarius uses a system of scales and pumps to ensure accuracy in patient fluid removal. Select the answer that correctly identifies when a balance alarm occurs if the treatment is performed using a low volume Aqualine. A. 25 milliliters B. 20 milliliters C. 60 milliliters D. 50 milliliters Edwards Lifesciences S.A. Ch. du Glapin 6 1162 Saint-Prex Switzerland +41 21 823 4300 www.edwards.com Edwards Lifesciences, Aquarius and Aqualine are trademarks of Edwards Lifesciences Corporation.