HAMILTONC1 HAMILTONC1 Technical specifications The HAMILTONC1 is fullfeatured intensive care ventilator, providing outstanding noninvasive performance. Due to its very compact design, it offers maximum flexibility in various user environments, be it intensive care, long term acute care, emergency, or respiratory care. The HAMILTONC1 ventilator s compact, powerful design also increases the availability of appropriate modes of therapy for ventilated hospital patients. Minimum size for maximum performance Adult, pediatric, and neonatal ventilation More than 4 hours of battery operating time Independent air supply Noninvasive ventilation and high flow oxygen therapy option Advanced ventilation modes, including ASV For more information, visit our website: www.hamiltonmedical.com/c1 Optional not available in all markets
Ventilation Cockpit Dynamic Lung Vent Status ASV target graphics Monitoring Realtime waveforms Others Realtime visualization of the lungs with representations of tidal volume, lung compliance, resistance, and patient activity Visual representation of ventilator dependence, grouped into oxygenation, CO2 elimination, and patient activity Graphic display of target and current parameters for tidal volume, frequency, pressure, patient activity, and minute ventilation Display of more than 50 monitoring parameters Paw, Flow, Volume, Plethysmogram, and Capnograph SpO2, volumetric CO2, sidestream CO2, Loops: PV, VFlow, PFlow, VCO2, Trends: 1, 6, 12, 24, and 72 hours Alarms Operator adjustable Low/high minute volume, low/high pressure, low/high tidal volume, low/high rate, apnea time, low/high oxygen, low/high PetCO2, low/high SpO2, low/high pulse, low/high perfusion index, flow, low/high PVI, low/high SpCO, low/high SpMet, low/high SpHb Special alarms O2 cell, disconnection, exhalation obstructed, loss of PEEP, pressure not released, flow sensor, expiratory valve, pressure limitation, performance limited, CO2 and SpO2, battery, power supply, gas supply, oxygen concentration, check patient interface (HiFlowO2, SpeakValve) Loudness Adjustable (1 10), configurable minimum loudness Ventilation Modes Mode Description Adult/Ped. Neonatal Closedloop control ASV Adaptive Support Ventilation. Guaranteed minute volume based on user setting and application of lungprotective rules. Pressure PCV+ Pressurecontrolled ventilation. Biphasic breathing PSIMV+ Pressurecontrolled synchronized intermittent mandatory ventilation SPONT Pressure support ventilation APRV Airway pressure release ventilation DuoPAP Duo positive airway pressure Volume (S)CMV+/APVcmv (Synchronized) controlled mandatory ventilation SIMV+/APVsimv Synchronized intermittent mandatory ventilation Noninvasive NIV Noninvasive ventilation NIVST Spontaneous / timed noninvasive ventilation ncpap Nasal continuous positive airway pressure ncpappc Nasal continuous positive airway pressure pressure control HiFlowO2 High flow oxygen therapy Maintenance Blower lifetime Dynamic lifetime surveillance, typically 8 years. 5year warranty. Optional not available in all markets 2
Standards IEC 606011, IEC 6060112, ISO 80601212, CAN/CSAC22.2 No. 606011, ES606011 Configurations Trolley accessories Options Humidifier support, cylinder holder, tubing support arm Volumetric mainstream capnography, sidestream capnography, DuoPAP/APRV, NIV/NIVST, Trends/Loops, Neonatal application, ncpap/ncpappc, SpO2, Masimo rainbow SET, PVI, HiFlowO2, SpeakValve Electrical and pneumatic specifications Input voltage Power consumption Backup battery time Oxygen supply Low pressure oxygen Air supply Peak flow 100 to 240 V AC 15/+10, 50/60 Hz 50 VA typical, 150 VA maximum Typical 4 h, maximum 4 h 30 min 2) 280 to 600 kpa (41 to 87 psi), V max 200 15, max. 600 kpa (87 psi) for low pressure Integrated turbine 260 (adult / pediatric), 40 (neonatal) Environment Temperature Operating: 5ºC to 40ºC Storage: 20ºC to 60ºC Humidity Altitude Degree of protection 10 to 95 noncondensing (operating and storage) Up to approx. 4,000 m (13,120 ft), 1,100 to 600 hpa IP21 Interface connectors USB, COM1 (RS232), nurse call, CO2, SpO2 Event log Storage and display of up to 1,000 events with date and time stamp IntelliTrig Automatic response to varying leaks and configurable trigger sensitivity in all modes Inspiratory leakage up to 85, expiratory leakage up to 40 PSync Guaranteed rate ventilation SpeakValve SpeakValve function makes the pressure controlled ventilation modes (PCV+, SPONT, PSIMV+) compatible with speaking valves Optional not available in all markets 2) Reduced display brightness 3
Controls Adult / Pediatric Neonatal Special functions Ventilation modes Patient groups Patient height Patient gender Patient weight (S)CMV+/APVcmv SIMV+/APVsimv+ PCV+ NIVST PSIMV+ DuoPAP APRV ncpappc Tidal volume PEEP/CPAP Oxygen I:E ratio MinVol (ASV) Inspiratory time (TI) Flow trigger Pressure control Pressure support Pressure ramp P high (APRV/DuoPAP) P low (APRV) T high (APRV/DuoPAP) T low (APRV) Expiratory trigger sensitivity (ETS) Flow (HiFlowO2) PSync SpeakValve Manual breath, O2 enrichment, standby, sigh, screen lock, apnea backup ventilation, inspiratory hold, print screen, suctioning tool, dimmable screen, configurable quickstart settings, startup settings based on patient height and gender, integrated pneumatic nebulizer, O2 consumption display See page 2, Ventilation modes adult / pediatric 30 to 250 cm male / female 4 to 80 b/min 4 to 80 b/min 5 to 80 b/min 5 to 80 b/min 20 to 2,000 0 to 35 cmh2o 21 to 100 1:9 to 4:1 (DuoPAP 1:599 to 149: 25 to 350 0.1 to 12 s off, 1 to 20 5 to 60 cmh2o, added to PEEP/CPAP 0 to 60 cmh2o, added to PEEP/CPAP 0 to 2,000 ms 0 to 60 cmh2o 0 to 35 cmh2o 0.1 to 40 s 0.2 to 40 s 5 to 80 of peak inspiratory flow 2 to 80 on/off on/off Manual breath, O2 enrichment, standby, screen lock, apnea backup ventilation, inspiratory hold, print screen, suctioning tool, dimmable screen, configurable quickstart settings, startup settings based on body weight, O2 consumption display See page 2, Ventilation modes neonatal 0.2 to 30 kg 15 to 80 b/min 15 to 80 b/min 15 to 80 b/min 15 to 80 b/min (without PSync 5 to 80 b/min) 10 to 80 b/min 2 to 300 3 to 25 cmh2o 21 to 100 1:9 to 4:1 (DuoPAP 1:599 to 149: 0.1 to 12 s off, 0.1 to 5 0 to 45 cmh2o, added to PEEP/CPAP 0 to 45 cmh2o, added to PEEP/CPAP 0 to 600 ms 0 to 45 cmh2o 0 to 25 cmh2o 0.1 to 40 s 0.2 to 40 s 5 to 80 of peak inspiratory flow 2 to 12 on/off Optional not available in all markets 4
Monitoring parameters Parameter Unit Description Numeric monitoring Waveforms Vent Status Dynamic Lung Pressure Paw Ppeak Pmean Pinsp PEEP/CPAP Realtime airway pressure Peak airway pressure Mean airway pressure Inspiratory pressure Positive end expiratory pressure/ continuous positive airway pressure Flow Volume Pplateau Flow Insp Flow Exp Flow Volume VTE/VTE NIV VTI/VTI NIV ExpMinVol/MinVol NIV MVSpont/MVSpont NIV Leak/MV Leak ; Plateau or end inspiratory pressure Realtime inspiratory flow Peak inspiratory flow Peak expiratory flow Realtime tidal volume Expiratory tidal volume Inspiratory tidal volume Expiratory minute volume Spontaneous expiratory minute volume Leakage minute volume Time Lung mechanics Oxygen Carbon dioxide Vt/IBW (adult/ped) Vt/Weight (neonatal only) I:E ftotal fspont TI TE fspont Cstat AutoPEEP RCexp Rinsp RSB PTP P0.1 O2 CO2 FetCO2 PetCO2 SlopeCO2 VTalv VTalv/min V CO2/min VDaw VDaw/VTE VeCO2 ViCO2 /kg /kg b/min b/min s s /cmh2o s cmh2o*s/l 1/l*min cmh2o*s;mbar*s mmhg;;kpa mmhg;torr;kpa CO2/l /min Leakage percentage at the airway Tidal volume/ibw ratio Tidal volume/weight ratio Inspiratoryexpiratory ratio Total breathing frequency Spontaneous breathing frequency Inspiratory time Expiratory time Percentage of spontaneous breathing rate Static compliance AutoPEEP or intrinsic PEEP Expiratory time constant Inspiratory flow resistance Rapid shallow breathing index Pressuretime product Airway occlusion pressure Airway oxygen concentration (FiO2) Realtime CO2 measurement Fractional endtidal CO2 concentration Endtidal CO2 partial pressure V/Q status of the lung Alveolar tidal ventilation Alveolar minute ventilation CO2 elimination Airway dead space Dead space fraction measured at the airway opening Exhaled volume of CO2 Inspired volume of CO2 Optional not available in all markets 5
Monitoring parameters Parameter SpO2 Plethysmogram SpO2 Pulse Perfusion index SpO2/FiO2 PVI SpCO2 SpMet SpHb SpOC Physical dimensions Size Weight Display Main patient outlet Oxygen inlet Low pressure oxygen inlet 24 cm (9.4 in) 31 cm (12.2 in) Unit Description Realtime plethysmogram Arterial oxygen saturation in blood 1/min Heart rate /dl Calculation of the oyxgen content Calculated approximation of PaO2/FiO2 Pleth variability index Carboxyhemoglobin Methemoglobin g/dl Total hemoglobin /dl Oxygen content See illustrations below 4.9 kg (10.8 lb) without trolley 8.4 in, TFT color, backlit, touch screen ISO 53561; 22OD/15ID DISS or NIST CPC quick coupling, 3.2 mm ID 21 cm (8.3 in) Numeric monitoring 63 cm (24.8 in) Waveforms Vent Status 136 cm (53.5 in) Dynamic Lung 689333.05 Specifications are subject to change without notice. ASV and IntelliTrig are trademarks of Hamilton Medical. 2016 Hamilton Medical AG. All rights reserved. Optional not available in all markets Hamilton Medical AG Via Crusch 8, 7402 Bonaduz, Switzerland ( +41 58 610 10 20 info@hamiltonmedical.com www.hamiltonmedical.com Your contact: