BIOPAC Blood Flow Monitor

Similar documents
Contact BIOPAC Systems, Inc. for replacement of any damaged component.

PRODUCT SHEET

Blood FlowMeter Owner s Guide

Improved Algorithm for Measurement of Blood Pressure based on a Laser Doppler Flowmetry Signal

Oxygen Saturation Monitors & Pulse Oximetry

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

Modeling a microvascular network with tubing

Solutions for transcutaneous monitoring

Best Practice for Calibrating LTH Conductivity Instruments

Exradin Ion Chambers. What attributes make Exradin the smart choice? EXRADIN Ion Chambers

SOLUTIONS Homework #1

Underwater measurement of photosynthetically active radiation

Respiration. Figure 22: Schematic representation of the respiratory system

Simultaneous two-photon imaging of oxygen and blood flow in deep cerebral vessels. Supplementary figure 1

Columbus Instruments

TSE Blood Pressure Monitor Invasive series

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Drilling Efficiency Utilizing Coriolis Flow Technology

Name. Lab Partners. The Dive Response. In this lab exercise, you will be designing and conducting your own experiments!

The physiological functions of respiration and circulation. Mechanics. exercise 7. Respiratory Volumes. Objectives

as provided by other available near infrared oximeters. Moreover, OxiplexTS complements the pulse oximeter in

TABLE OF CONTENTS 1 Overview Appearance Name and Model Intended Use Feature List Important Acroynms...

CHAPTER 3: The respiratory system

Photoplethysmographic sensors for perfusion measurements in spinal cord tissue

Lead Extraction Overview

Basic - Peripheral Vascular Assessment VASCULAR DOPPLER PHOTO-PLETHYSMOGRAPHY PULSE VOLUME RECORDING ANKLE AND TOE BRACHIAL INDEX

Cover Page for Lab Report Group Portion. Pump Performance

Lung Volumes and Capacities

SVENSK STANDARD SS-ISO :2005

Astral in AirView: Improving patient care through connectivity. ResMed.com

What is perfusion, and how do we measure it? Richard B. Buxton

Low-Flow Purging Procedure with MicroPurge basics Equipment. MP10 Bladder Pump Controller MP15 Control. MP30 Drawdown Meter.

Time-dependent blood flow and oxygenation in human skeletal muscles measured with noninvasive near-infrared diffuse optical spectroscopies

MR Advance Techniques. Functional MRI. Class IV

Instructions to User

Lucid System In-Service Training

Instruction Manual. Pipe Friction Training Panel

HI 2314 HI 2315 HI 23151

CHAPTER 7 : SMOKE METERS AND THEIR INSTALLATIONS

MEASURING BLOOD PERFUSION IN BONE USING NIRS BONE OPTICAL SPECTROSCOPY. A Thesis Presented. Ali Ibrahim Alneami. The Department of

CHAPTER 6. Oxygen Transport. Copyright 2008 Thomson Delmar Learning

Digiquartz Water-Balanced Pressure Sensors for AUV, ROV, and other Moving Underwater Applications

Collin County Community College. Lung Physiology

Figure 2: Principle of GPVS and ILIDS.

STARLOG. Capacitive Water Depth Probe

Introduction to AAE520 Forebody/LDV Lab

Leadership in Fluid Management

The Next Generation. Pulse Duplicator HDT-500. Medical Device Testing & Equipment Simulation Platforms Silicone Vessels

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.

Design of an Automated Perfusion Pump James J Higham

The Respiratory System

Respiratory System Physiology. Dr. Vedat Evren

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

PTC INSTRUMENTS 2301 Federal Ave Los Angeles CA Phone: Model 500 Automatic Operating Stand Type 3

FAS-W. Features. Applications. Automatic condensation hygrometer

Introduction to AAE520 Forebody/LDV Lab

Figure 1. A schematic diagram of the human respiratory system.

Research Grade Blood Pressure Transducer User's Manual

Fingertip Pulse Oximeter

DEPARTMENT OF THE NAVY DIVISION NEWPORT OFFICE OF COUNSEL PHONE: FAX: DSN:

Sampling Equipment Catalog. MicroPurge Low-Flow Pump Control

Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index

Astral in AirView: Improving patient care through connectivity. ResMed.com

ACV-10 Automatic Control Valve

NEULOG OXYGEN LOGGER SENSOR GUIDE

OptonPro. High-power laser up to 7000 mw. Laser therapy natural healing with the power of light

Real-time Analysis of Industrial Gases with Online Near- Infrared Spectroscopy

InFlow Modular perfusion bioreactor

Diacan and Diacan S. The safe and gentle vascular access for dialysis

TRANSCUTANEOUS CO2 MONITORING (TCpCO2) PURPOSE

OxyMon MkIII Optical Imaging made easy and affordable

Subsonic Wind Tunnel 300 mm

Patent Foramen Ovale and Fitness

CHAPTER 3: The cardio-respiratory system

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

VividTrac R. Video Intubation Device. INSTRUCTIONS FOR USE. English

_ pressure transducers. User Manual

FLUORESCENCE DETERMINATION OF OXYGEN

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

780S Ultra High Purity Series

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Impulsive Pressurization of Neuronal Cells. M. Nienaber, J.S. Lee, R. Feng and J.Y. Lim

The Lung Model. P16084 Alice D, Dakota B, Jade E, Meaghan E

Test Plans & Test Results

CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.

ALFRED HYPERBARIC SERVICE. Service and Care. Information for Patients

ASAHI Neurovascular Guide Wire

Heat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams.

AMS 2710 PCB pressure sensor module with V output

Instructions for Use for CAIMAN Instrument (12 mm x 44 cm) Item #: US731SU

Vitrex Steriheel Baby Sterile Cutting Safety lancet

BAPI Pressure Line of Products - FAQs

AUK Environmental Sensor. Determining the refractive index of the air. AUK Environmental Sensor

(fig. 3) must be at the same temperature as the water in this chamber CALORIMETRIC STUDIES OF THE EXTREMITIES

Micro Motion 3098 Gas Specific Gravity Meter

Chemistry - Scale-up F.32. Lara TM - Controlled - Lab Reactor. The Concept

Pressure in Human Body

EC214 EC215 - EC215R Bench Conductivity Meters

Gerald D. Anderson. Education Technical Specialist

Transcription:

BIOPAC Blood Flow Monitor Technique - Laser Doppler Flowmetry (LDF) The LDF100C is a laser Doppler blood perfusion monitor used to measure real-time micro-vascular red blood cell perfusion in tissue. LDF100C Blood Perfusion Blood Flow Blood Flux Laser Doppler signals from the tissue are recorded in BPU (Blood Perfusion Units) which is a relative units scale defined using a carefully controlled motility standard comprising a suspension of latex spheres undergoing Brownian motion. Perfusion is sometimes also referred to as micro-vascular blood flow or red blood cell flux.

What does LDF measure? What volume of tissue does the LDF100C measure? LDF defines a perfusion parameter from information contained in the optical spectrum of light remitted from the tissue. The actual measurement sampling volume or depth can only be determined by identifying precisely which blood vessels and erythrocytes have interacted with the remitted light, which in turn, is principally dependant on two parameters; namely the optical scattering and optical absorption coefficients of the tissue under observation. Since both of these coefficients are entirely dependent on the site of observation and perfusion of the microvasculature at the time of measurement, it is impossible to determine the actual sampling volume/depth at any tissue site. Generally speaking however, we have estimated that for well-perfused tissue such as muscle, the mean sampling depth is in the region 0.5-1.0 mm with a concomitant sampling volume in the region 0.3-0.5 mm3. For cutaneous measurements, the sampling depth is likely to be in the range 1.0 1.5 mm. These estimates have been obtained heuristically through many years of experience and are based on both in vitro observations and mathematical modelling of photon diffusion through 'imaginary tissues using Monte-Carlo techniques

What does LDF measure? Blood Perfusion and the BPU The primary function of the a Laser Doppler Flow meter is to produce a blood perfusion output signal that is proportional to the red blood cell perfusion (or flux). This represents the transport of blood cells through microvasculature and is defined as: Microvascular Perfusion Red Blood Cell Flux) = Number of blood cells moving in the tissue sampling volume x Mean velocity of these cells Microvascular blood perfusion therefore, is the product of mean blood cell velocity and mean blood cell number concentration present in the small measuring volume of tissue under illumination from the probe. Probes are individually calibrated against a constant, known motility standard so that, for a given perfusion situation, all LDF probes will read the same value of blood perfusion expressed in blood perfusion units (BPU).

What does LDF measure? Microvascular Blood Perfusion (BPU) = Number of moving blood cells in volume sampled X Mean velocity of moving cells Volume of tissue sampled 0.5-1 mm 3 No measure of volume in LDF BPU is an arbitrary unit (not ml/min/g tissue) Used to measure RELATIVE changes in perfusion

How does LDF work? Tissue is illuminated by low power laser light; the light is scattered by the static tissue structures and moving blood cells Portion of the light is Doppler shifted Adjacent fiber optic detects un-shifted and Doppler-shifted light Signal is processed to give a parameter related to tissue blood perfusion

What are the advantages of LDF? The LDF technique offers substantial advantages over other methods (e.g. microbeads ) in allowing the continuous measurement of microvascular blood perfusion. The LDF may be used non-invasively (since the probe is not actually required to touch the surface of the tissue) and in no way harms or disturbs the normal physiological state of the microcirculation. LDF is both highly sensitive and responsive to local blood perfusion and is also versatile and easy to use for continuous monitoring. Continuous/real-time response time 0.15s Sensitive to small changes May be used non-invasively, On skin or organ surface where exposed Small probe dimensions Minimal trauma where used invasively

What are the limitations of LDF? Sensitive to tissue and cable movement Site-to-site variation as probe is moved Due to variation in tissue optics Relative, arbitrary units Measurements obtained by LDF are intrinsically of a relative nature. Although such measurements are proportional to perfusion, the factor of proportionality will be different for different tissues. All limitations may be minimized by experimental design

LDF Experimental Design Limit movement artifacts Probe selection Maintain probe position Change due to provocation Site-to-site variation

How to use Arbitrary Units? Occlusion and Hyperemia Occlusion = an obstruction or a closure of a passageway or vessel (blocked flow) Hyperemia = an increase in the quantity of blood flow to a body part; engorgement Valsalva maneuver Valsalva maneuver = expiratory effort against a close glottis (the opening between the vocal cords at the upper part of the larynx). which increases pressure within the thoracic cavity and thereby impedes venous return of blood to the heart.

Using arbitrary units -- hyperemia (HP) (RF) (BZ) Hyperemic Index = (HP - BZ) / (RF BZ)

Research Applications of LDF Cerebral monitoring (stroke, injury...) Transplantation surgery (skin grafts, free flaps...) Vital organ monitoring (organ viability...) Tumor vascular research (angiogenesis...) Peripheral vascular disease (diabetes...)

Probes and Applications Surface and Digit Probes Suturable and Miniature Surface Probes Needle and Pencil Probes Single Fiber Probes

Surface and Digit Probes TSD140 General purpose surface probe Primarily useful with largely flat surfaces TSD142 Specifically designed to be used with on human digits. The radius of curvature is designed to reduce probe pressure and reduce the risk of the probes detaching Applications: Skin, large organ, Noninvasive, Adhesive ring

Suture & Miniature Surface Probes TSD143 TSD146 Applications: Small organ, non invasive e.g. Flap monitoring

Needle Probes TSD144 & TSD145 Diameter 0.5 mm Applications: Invasive tissue measurement; e.g. Cerebral monitoring Ideally suited to Stereotactic setup Using manipulator to position

Pencil Probes All the probes are constructed from medical grade stainless steel tubing. The default length is 25 mm long TSD custom TSD custom Diameter 1.0 mm Diameter 1.0 mm Custom lengths Applications: Noninvasive, Clamped over tissue

Single Fiber Probes TSD147 TSD148 Flexible Fiber; Diameter 0.5 mm Applications: Chronic Implantation e.g. fetal brain

Smart probes Probe Features Calibration automatically loaded MRI-compatible Surface probes contain no metallic parts Autoclavable Where sterility required, up to 20 cycles

Practical Aspects of LDF Calibration Laser Doppler signals from the tissue are recorded in BPU (Blood Perfusion Units) which is a relative units scale defined using a carefully controlled motility standard comprising a suspension of latex spheres undergoing Brownian motion.

Practical Aspects of LDF Meaning of zero flow (zero BPU)? The zero (0000) reading of the LDF has been obtained by calibrating the system against a special static scattering material where no movements occur. In such cases the back-scattered light processed by the LDF contains no Doppler shifted frequency components and a true zero is obtained. A zero reading therefore indicates zero motion both in the measuring volume under examination and artefactual motion arising from relative movements between the probe and the measuring volume. During in vivo measurements, rarely is an absolute zero obtained. Even during total occlusion of tissue blood perfusion, there is often some small, residual motion of blood cells trapped in the vessels, as well as some small muscle and tissue movement in the measuring volume. Even after surgical removal of tissue, localised cell movement and Brownian motion may still occur in the severed blood vessels.

Practical Aspects of LDF Definition of the Backscatter Signal (BS) The LDF also produces a signal, which is proportional to the total light remitted or backscattered from the tissue. This is called the Backscatter Signal (BS) and is available as an analogue voltage output from the back panel of the LDF monitor. The backscatter is expressed as a percentage fraction of the laser light remitted from the tissue from the total amount of laser light incident on the tissue. For example, in highly perfused tissues, the BS will be low due to increased photon absorption. Situations where the BS signal is close to zero may indicate that the probe has come into contact with whole blood, this could cause the BPU reading to saturate since the system is no longer monitoring microvascular perfusion.

Calibration Motility Standard Latex spheres under Brownian Motion Probes have individual calibrations Instrument recognizes Probe ID Customers should avoid using probes with the same Probe ID

The Backscatter Signal Diagnostic Signal A Step in the Backscatter signal Suggests probe location changed Low backscatter Flow signal is cut out Probe has become detached Faulty probe High backscatter Probe detached, facing a reflective surface (e.g. bone)

Summary LDF is a sensitive technique for monitoring changes of micro-vascular blood flow in real time Wide range of applications from basic physiology teaching to research studies The BIOPAC LDF100C is a full-feature LDF instrument Probes available for a wide range of applications (BIOPAC TSD140 series)