Mixers. Venturi proportional mixers EMM & EMMTR (E2351 rev /07/2017)

Similar documents
Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010)

Accessories. Combustion ratio regulators FCR-REG-II (E5106 rev /04/2014)

Accessories. Pressure regulators Zero Governors (EN88/1) BZR-REG-II (E5102 rev /11/2017)

Accessories. Flexible Compensators FN & ESA FLEX & INOXESTENS (E5603 rev /03/2015)

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010)

Accessories. Orifice flow meters with measuring ring chambers POP-U-S (E5719 rev /06/2014)

Burners. Blast pilots PBC & PBST (E3280 rev /04/2018)

THE WAY THE VENTURI AND ORIFICES WORK

Electronics. Portable differential pressure gauge ESA DPG-E (E7220 rev /10/2015)

CHAPTER 5 COMBUSTION AND NOZZLES PILOT BURNER V F. Fig. 11B FIG11A

CAST IRON SAFETY VALVE TYPE 6301

V5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK

Incorrect installation, adjustment, or misuse of this burner could result severe personal injury, or substantial property damage.

Flow controller Type ED/CCB311 Instruction manual

GM-7000 Series CE Approved Gas Control Valve

BURNERS NOZZLE MIX SINGLE TUNNEL MULTIPLE TUNNEL

6301 TYPE CAST IRON SAFETY VALVES

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

H15 Series BASO 100% Shutoff, Automatic Pilot Valve

Dual Solenoid Gas Valve Installation

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH...

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

Declaration of Conformity as per Directive 97/23/EC

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

North American Orifice Metering System

Jupiter Type 4 Tube Owner s Manual

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

BURNERS NOZZLE MIX SINGLE TUNNEL MULTIPLE TUNNEL

Series MG Mixing Tubes

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

BGA158 Series CE Approved Class A Shutoff Gas Valve

CARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition

453 Series Steam Heated Vaporizing Regulator

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref:

Instruction Manual Contact Pressure Vacuum Gauge

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

BGA158 Series CE Approved Class B Shutoff Gas Valve

G96 Series BASOTROL Dual Operator Valve

GAS SUPPLY DESIGN GUIDE

Dri-Line Mk3 Monnier Compressed Air Drain Trap

FLOMIXERS SELECTION DATA ALL GASES

Manual Actuated Boiler Blowdown Valves

ML3M Monnier Miniature Compressed Air Lubricator

Siphon vessel / Priming aid

G92 Series BASOTROL Automatic Pilot Gas Valve

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

Manual. Gas burners gas burners without flame protection gas burners with flame protection.

OPERATION MANUAL NTF-15

Declaration of Conformity as per Directive 97/23/EC

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

GAS SUPPLY APPLICATION GUIDE

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Radiator valves VDN1.. VEN1..

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

USER MANUAL. JET TST and JET TST S.

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

Operating manual. LINDOFLAMM Acetylene special burner LF-H series.

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

Instruction Manual No. 742, 8/98

Valves for Biogases and Recycling Gases

Glass tube flowmeters Series 2000

VGF... VGH... Building Technologies Division Infrastructure & Cities Sector VGG... VGF... VGH...

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve

6-5 Maintenance Manual

ISO INTERNATIONAL STANDARD. Small craft Liquefied petroleum gas (LPG) systems

Radiator valves VDN2.. VEN2.. VUN2..

Operating manual for Material pressure tanks Vol./1 and Vol./2

FIREFIGHTING EQUIPMENT

IPG IGNITION GAS PILOTS BACK-LOADED GAS

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

VMR VMR-OTN VMR 6 bar

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

ACCESSORY KIT INSTALLATION INSTRUCTIONS

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

NORMAL OPERATING PROCEDURES Operating Parameter Information

Declaration of Conformity as per Directive 97/23/EC

3-port seat valves with externally threaded connection, PN 16

MT-239-E ENGLISH PRESSURE REGULATOR STAFLUX MINI TECHNICAL MANUAL INSTALLATION, COMMISSIONING AND MAINTENANCE INSTRUCTIONS

553 Series.

OPERATION MANUAL PNEUMATIC VALVES

Rate of Flow Valve Series 120

Pressure maintenance valve SDV-P / SDV-P-E

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

A guide to Part 10 of the

VR46.5V(A)/VR86.5V(A) SERIES

BGC258 Series BASOTROL Gas Valve

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public

Automatic Non-freeze Valve NF6

OPERATION MANUAL NTF-60 Plus

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Transcription:

Mixers Venturi proportional mixers EMM & EMMTR (E2351 rev. 04-11/07/27)

GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff, respecting the norms present at the time and place of the installation. ¾ To avoid damage to people and things, it is essential to observe all the points indicated in this handbook. The reported indications do not exonerate the Client/User from observing general or specific laws concerning accidents and environmental safeguarding. ¾ The operator must wear proper DPI clothing (shoes, helmets...) and respect the general safety, prevention and precaution norms. ¾ To avoid the risks of burns or high voltage electrocutaion, the operator must avoid all contact with the burner and its control devices during the ignition phase and while it is running at high temperatures. ¾ All ordinary and extraordinary maintenance must be performed when the system is stopped. ¾ To assure correct and safe use of the combustion plant, it is of extreme importance that the contents of this document be brought to the attention of and be meticulously observed by all personnel in charge of controlling and working the devices. ¾ The functioning of a combustion plant can be dangerous and cause injuries to persons or damage to equipment. Every burner must be provided with certified combustion safety and supervision devices. To dispose of the product, abide by the local legislations regarding it. GENERAL NOTES: ¾ In accordance to the internal policy of constant quality improvement, ESA-PYRONICS reserves the right to modify the technical characteristics of the present document at any time and without warning. ¾ It is possible to download technical sheets which have been updated to the latest revision from the www.esapyronics.com website. ¾ The products manufactured by ESA-PYRONICS have been created in conformity to the UNI EN 746-2:20 Norms: Equipment for industrial thermal process - Part 2: Safety requirements for combustion and the movement and treatment of combustible elements. This norm is in harmony with the Machine Directive 2006/42/CE. It is certified that the products in question respect all the requirements prescribed by the above mentioned Norms and Directives. ¾ Certified in conformity with the UNI EN ISO 90 Norm by DNV GL. CERTIFICATIONS: ¾ The burner must be installed correctly to prevent any type of accidental/undesired heat transmission from the flame to the operator or the equipment. The products comply with the requirements of the Eurasian market (Russia, Belarus and Kazakhstan) and are exempt from the EAC certification ref. Doc. -11/437 ¾ The performances indicated in this technical document regarding the range of products are a result of experimental tests carried out at ESA-PYRONICS. The tests have been performed using ignition systems, flame detectors and supervisors developed by ESA-PYRO- NICS. The respect of the above mentioned functioning conditions cannot be guaranteed if equipment, which is not present in the ESA-PYRONICS catalogue, is used. Headquarters: Esa S.p.A. Via Enrico Fermi 40 24035 Curno (BG) - Italy Tel +39.035.6227411 Fax +39.035.6227499 esa@esacombustion.it CONTACTS / SERVICE: www.esapyronics.com International Sales: Pyronics International s.a. Zoning Industriel, 4ème rue B-6040 Jumet - Belgium Tel +32.71.256970 Fax +32.71.256979 marketing@pyronics.be www.esapyronics.com 2

The EMM mark identifies a series of aluminum mixers air and gas type "venturi", while the abbreviation EMMTR identifies a series of EMM mixers with a mixing group. EMM APPLICATIONS ¾Pilot burners. ¾Pre-mix burners up to 40 kw (in stoichiometric ratio). GENERAL: CHARACTERISTICS ¾Function: with various types of fuel ¾Air and gas inlets: separate and adjustable ¾Maximum operating pressure: 500 mbar ¾Maximum fluid temperature: 60 C ¾Flow direction and mounting position: any MATERIAL COMPOSITION: EMMTR F2351I03 ¾EMM mixer: Aluminum NB: regarding the materials of the mixing group components please follow the technical specifications. DESCRIPTION The EMM series identifies proportional gas and air mixers. The air passing through a port produces an aspiration in the throat section by dragging the fuel gas. The amount of dragged gas is easily adjustable through a micrometer valve. Once set, the fuel ratio to air remains constant on a wide range of flow (maintaining constant gas pressure). A pressure regulator can be used to maintain constant gas pressure, exactly at atmospheric pressure, for all gas flows. The total potency of the blend sent to the burner is controlled by a single valve on the combustion air line. This valve can be motorized for automatic process control. EMMTR preassembled groups include a zerogovernor on the gas line. The mixers have a typical turn-down of 3: 1 depending on capacity. If larger intervals are required or if multiple mixers are connected to a single regulator, it is recommended to use ESA series BZR regulators (see data sheet E5102). MIX OUTLET GAS INLET F2351I04 AIR INLET D2351I www.esapyronics.com 3

WARNINGS ¾Make sure that the working pressure and the temperature fluid is below the maximum allowed. ¾Check the correct installation of the mixer before starting the flow in the pipeline. ¾In the event of malfunctioning of the mixer, follow the indications of this manual in the "MAINTENANCE "or contact the ESA PYRONICS assistance service ¾Any modification or repair carried out by third parties can compromises the security of the application and makes automatically guarantee the general warranty conditions INSTALLATION Arrange the mixer in such conditions as not to be exposed to direct radiation from heat sources, or held by combustion products, liquids, solvents or corrosive gases. CHOICE OF THE MIXER 1 - The potentials shown in the table refer to 100% of primary process air. 2 - Determine the maximum potential of the burner or burner to be fed with the mixer at the mixture pressure corresponding to the pressure of combustion air. 3 - Multiply the total potential for the percentage primary ventilation (air / gas ratio) required. 4 - If the requested potential falls between two types of mixtures we should choose the smallest model for have a greater potential range. 5 - Select the balanced modulator according to the potential of the burner and the type of gas. INSTALLATION 1 - Check that the line pressure is lower than maximum permissible operating pressure. 2 - Only the mixer, (without zerogovernor) can be mounted in every position. 3 - Ensure that no foreign bodies have entered inside the mixer before carrying out the assembly possibly blow with compressed air. 4 - Make sure that the threads conform to those of the mixer according to the UNI ISO 7/1 standard. 5 - Use thread sealers or similar paste on the male threads of the pipes. 6 - The air inlet is marked on the mixer body. The pipes that will be connected must be of the same diameter of the respective entrance to reduce pressure drop. 7 - Check the correct alignment of the pipes attachment. Keep a distance from the walls that allow free air circulation. 8 - The correct assembly of a mixer equipped with zerogovernor always provides horizontal positioning of the membrane and consequently the actual zerogovernor 9 - The zerogovernor should be mounted the nearest possible to the micrometric gas regulation valve. 10 - It is preferable to mount a zerogovernor for each mixer. The distance between the zerogovernor and the mix the operator must be as small as possible to reduce the loading notes that should never be higher than 0.25 mbar. 11 - The connections between the mixture output and the user input must be at least the same diameter as the the mixture output. Do not insert any valves or restriction of any kind on the mixture piping. Mixture valves or restrictions of any kind. Never exceed a pressure drop of 0.2 mbar / mt of piping in the mixing pipe. 12 - To start the burner open the gas tap, open the air cock and switch on. To obtain the type of flame desired, act on the micrometric valves placed on the air and gas lines. FLOW TABLE POWER [kw] Minimum Air pressure [mbar] passing section Model 3,5 17,6 35,2 70,4 105,6 to the burner (mm 2 Mixture pressure [mbar] ) 1 5 10 20 30 2 EMM 33,2 0,9 2,1 2,9 4,1 5 3 EMM 43,3 1,2 2,6 3,5 5,3 6,4 4 EMM 62,6 1,8 4,1 5,6 7,9 9,7 6 EMM 117 3,3 7,3 10,3 14,7 17,9 8 EMM Ø 8,5 2 5,7 12,8 18 25,5 31,2 8 EMM Ø 11,5 247 10,9 24,5 34,6 49 60 12 EMM 450 22.44 50.5 71 100 122 www.esapyronics.com 4

OVERALL DIMENSIONS - EMM "D" "E" GAS INLET Ø"B" MIXTURE OUTLET Ø"C" AIR INLET Ø"A" CH "F" D2351I02 Model Ø A Ø B Ø C D E F Mass [Kg] 2 EMM G 1/4 G 1/4 G 3/8 90 37 28 0,2 3 EMM G 3/8 G 1/4 G 3/8 90 37 30 0,25 4 EMM G 1/2 G 3/8 G 1/2 110 44 32 0,4 6 EMM G 3/4 G 3/8 G 3/4 120 44 38 0,45 8 EMM Ø 8,5 G 1 G 3/8 G 1 130 44 42 0,45 8 EMM Ø 11,5 G 1 G 3/8 G 1 130 44 42 0,45 12 EMM G 1.1/2 G 1/2 G 1.1/2 180 50 60 0,95 www.esapyronics.com 5

OVERALL DIMENSIONS - EMMTR "H" "I" Pos. Description Air interception ball valve 02 Air pressure stabilizer 03 "Venturi" mixer MIXTURE OUTLET Ø"C" "G" 04 Micrometric regulation gas valve 05 Gas flow stabilizer 06 Gas interception ball valve "F" "D" "E" GAS INLET Ø"B" 02 03 04 05 06 AIR INLET Ø "A" D2351I02 Model Ø A Ø B Ø C D E F G H I Mass [Kg] 2 EMMTR G 1/4 G 3/8 G 1/4 150 59 209 172 25 61 0,95 3 EMMTR G 3/8 G 3/8 G 3/8 150 59 209 172 25 61 0,95 4 EMMTR G 1/2 G 3/8 G 1/2 184 66 250 170 30 88 1,25 6 EMMTR G 3/4 G 3/8 G 3/4 210 75 285 165 30 88 1,40 8 EMMTR G 1 G 3/8 G 1 264 86 350 173 37 97 2,30 www.esapyronics.com 6

GENERAL MAINTENANCE PLAN Maintenance and installation must be carried out by qualified personnel, in compliance with current regulations; once installed, it is always advisable to perform a tightness test of the threads. Operation Type Advised time Thread integrity O yearly Notes Make sure there are no leaks towards the outside. Maintenance of mixer S yearly Check the conditions of the mixer. Notes: Key: O = ordinary; S = extraordinary ORDINARY MAINTENTANCE For correct maintenance of the EMM mixers strictly follow the following instructions. Before carrying out maneuvers with the system on, assess that the process and operator safety is not compromised, if necessary check with the system turned off. INTEGRITY CHECK ¾The integrity of the threads can be checked visually. If necessary, use liquid to look for leaks. EXTRAORINDARY MAINTENANCE For correct maintenance of the EMM mixers, follow the following instructions carefully to be carried out with the system switched off. MIXER MAINTENANCE 1 - Unscrew and extract the mixer from the piping and check the status of the internal components. 2 - Clean the inside of the mixer body and the unit with a clean cloth and compressed air. Do not use tools that could damage internal parts. 3 - Reassemble the mixer in its housing, according to the steps indicated in the "INSTALLATION" section. www.esapyronics.com 7

ORDERING CODES - SINGLE VENTURI MIXER - EMM EMM Model 2 EMM 3 EMM 4 EMM 6 EMM 8 EMM-8.5 8 EMM-11.5 12 EMM 2 3 4 6 8-8.5 8-11.5 12 ORDER CODES - MIXER WITH ADJUSTMENT GROUP EMMTR Model 2 EMMTR 3 EMMTR 4 EMMTR 6 EMMTR 8 EMMTR 2 3 4 6 8 www.esapyronics.com 8