Installation, Operation, Maintenance Manual For Quick-Jaw Models AL363, L364 & AL366

Similar documents
Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7

Hotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:

Pressure Regulators. Operating Instructions. Instrumentation

Booster Pump PB4-60 Replacement Kits

Industrial Refrigeration Control Valves. Catalog C12-PVS Parker Valve Station (PVS) Sizing Guide

Installation and User Manual

Instruction & Parts Manual

OPERATING INSTRUCTIONS AND OWNER S MANUAL READ AND FOLLOW ALL INSTRUCTIONS

Installation Instructions

Retractable Hose Reel with 3/8" x 50' PVC Hose

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL D INFLATABLE JACKS

Product Information News

LITTLE MAX MODEL 50G 50,000 BTU PROPANE TORCH

Poppetted Coaxial Drop Tube Assembly for use with Auto Limiter II. Installation Instructions

Steel Spring Driven Reel Instruction Manual

HOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)

V-24 OXYGEN LANCE VALVE

WARNING: FOR OUTDOOR USE ONLY

MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2

PDY TON HYDRAULIC CRIMPING TOOL WARNING

2 NPT MULTI-PORT RELIEF VALVE MANIFOLD SERIES INSTRUCTION MANUAL

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Air Mask Low/High Pressure

GAS CONVERSION KIT Installation Instructions Range/Rangetop

453 Series Steam Heated Vaporizing Regulator

Hydraulic Punch Drivers

Bulletin 2533-M3/USA Service Bulletin. Series PR25MA, PR25P, PR25S, PR32P, PR32S. Effective: July 1, Pilot Operated Pressure Reducing Valves

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

3/8" Dr. Air Butterfly Impact Wrench

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

Warning: NEVER ALTER TEST EQUIPMENT

Product Information News September 26, 2003

AIR/OVER HYDRAULIC JACK 20 TON

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Pressure Balance Trim

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Operation Manual Piston Sensed Gas Pressure Regulators

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

1.0 - OPENING AND CLOSING THE DOOR

Modular Gas System. Modular Gas Delivery Stick Components for Microelectronics Equipment Gas Boxes

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

AIR DRIVE ROLL FEED CARTON STAPLER MODEL: H-1031 MANUAL

Float Operated Level Controllers

Full Internal Relief Valves Instruction Manual

Safe Work Instructions For Oxygen Acetylene Equipment

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

ELKHART BRASS MANUFACTURING COMPANY

1800C and 1800C-HC Series Service Regulators

PRODUCT SERIES: A-SF-3000BD

Maintenance and Repair. AirHawk II Air Mask. Second Stage Regulator. Order No.: /02 Prnt. Spec (I) MSAsafety.

1200B2 Series Service Regulators. Instruction Manual

Yoke Block Instruction Manual

Combination Breathing Apparatus

installation instructions

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

CS150 CAP STAPLER OWNER S MANUAL

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

5 Gallon EVkeg Operation Manual

H4802, H4802-1, H , and Pole Tampers

Protocol Switchover Station

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

MANUAL BE SERIES Test Benches

Hot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)

MMR Air Mask With. with Quick-Connect Hose

30T A/Manual Hydraulic Shop Press

JACKSON GRILLS PATIO FIRE

Copyright MAY, 2008 By Grizzly Industrial, Inc. Warning: No portion of this manual may be reproduced in any shape or form without the written

RG1200 Service and Repair Manual

TANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

MEGR-1627 Instruction Manual

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Natural Gas Conversion Kit

User Instruction Manual

500SE SECOND STAGE SERVICE PROCEDURE


Beverage Systems. Component Inspection and Service TSB-Y Date: Subject: Products Affected: Description: July Inspection of CO 2

75 Ton SD Shop Press Operating Instructions

Section 3- Repair and Calibration Procedures

HPB25 Hydraulic Paving Breaker

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

PORTABLE 5 GALLON AIR TANK ASSEMBLY & OPERATING INSTRUCTIONS

20 Ton SD Shop Press Operating Instructions

Operation Manual Guillotine Cutter RC-5

MODEL H RPM

Transcription:

Installation, Operation, Maintenance Manual For Quick-Jaw Models AL363, L364 & AL366 February 2014 Form FVC076 - Rev 07 IMPORTANT: KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER. 1. Contact with or inhalation of Liquid Anhydrous Ammonia (NH 3 ) or of LP Gas, can cause SERIOUS INJURY OR DEATH. 2. Before installation or removal of any tank valve, the system must be purged of all product. 3. Personal Protective Equipment (PPE), safety gloves, goggles and clothing should be worn. For proper handling and storage of NH 3, and Liquefied Petroleum Gas, refer to ANSI Standard K61.1. and NFPA Pamphlet 58. 4. An abundant supply of fresh water should be available to provide immediate first aid treatment for exposure to NH 3 and LP Gas. 5. To prevent the accidental opening of any valve, never grasp or carry a valve by its Hand wheel or handle. 6. To ensure a long term and safe operation, the manufacturer recommends that under normal service conditions this product should be inspected at least once every year and be repaired or replaced as required. Tools Required Safety Equipment (i.e. gloves, goggles, and clothing), 12" Adjustable Wrench, 7/16" Open End Wrench, and 12" Pipe Wrench. 1. FAILURE TO READ AND UNDERSTAND THE INSTRUCTIONS CONTAINED IN THIS INSTALLATION, OPERATION AND MAINTENANCE MANUAL CAN LEAD TO PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH. If you have questions about anything contained in this manual or desire additional copies, please call Squibb-Taylor at 1-800-345-8105 and ask for customer service. 2. If Safety Interlock Arm 10 or Safety Interlock Pins 12 in Figure 1 are damaged or missing, DO NOT OPERATE THE VALVE. In this condition, the valve is EXTREMELY DANGEROUS since it can easily be disconnected from the acme connection with the valve in the OPEN position. 3. LP gas and NH 3 gas vapors are extremely flammable and must not be exposed to any possible source of ignition. 4. Always have an ample supply of water nearby for flooding any body surface coming in contact with NH 3 Form FVC 076-Rev 07 GEARS 45064 1 of 8

Installation - (Refer to Figure 1 for Item Numbers) Step 1: Shutoff any supply valves and bleed the attachment hose of all product. Step 2: Open the valve and leave it open until installation is complete. Residual liquids in the hose can vaporize and a pressure will build-up in the system if the valve is closed. Step 3: Apply PTFE tape or sealant to the male hose thread and screw it securely into the valve Inlet Port 1. Step 4: Close the Valve. Operating Procedure Step 1: Pull the Locking Collar 2 upward to expand the Acme Jaws 3. Step 2: With the Acme Jaws held open, place the Acme Jaws over the Male Acme Connection until the Seal Face 4 is resting squarely on the rubber seal of the Male Connection. Form FVC 076-Rev 07 GEARS 45064 2 of 8

Operating Procedure, continued Step 3: Release the Locking Collar 2 and allow the Collar spring to close the Acme Jaws, rotate the Collar slightly clockwise until the jaws snap into the Male Acme Threads. Allow Collar to spring back Step 4: Rotate the Locking Collar clockwise to fully tighten the connection. Turn Clockwise KEEP TWO HANDS ON THE VALVE UNTIL THE VALVE IS FULLY OPENED Step 5: Depress the Handle Latch 5 with your thumb and pull the Valve Handle 6 upward until the valve is fully open, as shown in position 7. The valve is now Connected, open and product is flowing out of the valve. NOTE: The Safety Interlock Arm 10 prevents lifting of the Locking Collar 2 while the Valve Handle is in the OPEN position by the way of the Spring Slider 11 and the Safety Interlock Pins 12. Form FVC 076-Rev 07 GEARS 45064 3 of 8

When Filling Is Complete Step 1: Slap the Valve Handle 6 to the CLOSED position 8. Ensure the Safety Handle Latch 5 is engaged into the bonnet slot 9. This prevents opening of the Valve if the handle is struck accidentally.. Safety Handle Latch Engaged Step 2: Close the Valve connected to the Valve inlet port 1, if present. Some configurations will have Integral Back Checks rather than a Valve. Step 3: STEP 3 IS CRITICALLY IMPORTANT FOR YOUR SAFETY. Rotate the Locking Collar 2 slowly counter-clockwise to bleed product from the connection BEFORE sliding it upward to release the Acme Threads. Turn Counter-Clockwise DO NOT PULL UP ON THE LOCKING COLLAR UNTIL BLEEDING OF THE CONNECTION HAS STOPPED. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR DEATH. Form FVC 076-Rev 07 GEARS 45064 4 of 8

Continued... Step 4: After the bleeding of product has stopped, slide the Locking Collar 2 upward and pull the Valve away from the connection. The Locking Collar may then be released. Maintenance (Refer to Figure 1 for Item Numbers) A. The following maintenance kits are provided for the end user, Specific maintenance instructions are provided for each kit. 1. Shut-off Seal 13 replacement. 2. Valve Handle 6 replacement. 3. Stem Seal 14 replacement. 4. Safety Arm 10 replacement. NEVER OPERATE THE VALVE WITH THE SAFETY INTERLOCK ARM OR SAFETY INTERLOCK PINS MISSING OR DAMAGED! B. Periodically monitor the tightness of the Set Screw 17, Collar Screws 15 16, and Arm Screws 23. These Screws must be kept tight. C. Periodically monitor the condition of the Safety Interlock Arm 10. Replace if broken, bent, or shortened from its normal length. With the Valve in the open position, the safety Interlock Arm should prevent the Locking Collar 2 from moving to an "unlatched" position. If the Safety label 24 is torn or missing, replace it with a no charge Safety Label Kit. Form FVC 076-Rev 07 GEARS 45064 5 of 8

FIGURE 1 Form FVC 076-Rev 07 GEARS 45064 6 of 8

NO. DESCRIPTION QTY. 1 VALVE INLET PORT X 2 LOCKING COLLAR 1 3 ACME JAWS (SET OF4) 1 4 SEAL FACE X 5 HANDLE LATCH 1 6 VALVE HANDLE 1 7 OPEN POSITION X 8 CLOSED POSITION X 9 BONNET SLOT 1 10 SAFETY INTERLOCK ARM 1 11 SPRING SLIDER 1 12 SAFETY INTERLOCK PINS 2 13 SHUT-OFF SEAL 1 14 STEM SEAL 1 15 COLLAR SCREW X 16 COLLAR SCREW X 17 SET SCREW 1 18 BONNET SEAL 1 19 LATCH SPRING X 20 HANDLE PIN 1 21 RETAINING RINGS 1 22 O-RING X 23 ARM SCREWS 2 24 SAFETY LABEL 1 AVAILABLE KITS NUMBER NAME & PARTS INCLUDED ASSEMBLY PROCEDURE QJ-363-0020 SEAL KIT SHUT-OFF SEAL 13 BONNET SEAL 18 QJ-363-0021 VALVE HANDLE KIT VALVE HANDLE 6 HANDLE LATCH 5 LATCH SPRING 19 HANDLE PIN 20 QJ-363-0023 STEM SEAL KIT STEM SEAL 14 BONNET SEAL 18 QJ-363-0024 SAFETY ARM KIT SAFETY ARM 10 ARM SCREWS 23 SAFETY LABEL 24 QJ-363-0025 SAFETY LABEL KIT SAFETY LABEL 24 QJ-363-1701 STEM KIT Form FVC 076-Rev 07 GEARS 45064 7 of 8

User Safety Responsibility Statement for All Parker Products FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL IN- JURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. Form FVC 076-Rev 07 GEARS 45064 8 of 8