SERIES SAFETY VALVE

Similar documents
29 SERIES - SAFETY VALVE

Types 749B and R130 Changeover Manifolds

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

PROCEDURES FOR REPAIRS TO ASME NV STAMPED PRESSURE RELIEF DEVICES OF NUCLEAR SAFETY RELATED PRESSURE RELIEF VALVES

R122H, R222, R232A, and R232E Series Instruction Manual

1200B2 Series Service Regulators. Instruction Manual

R600 and HSRL Series Instruction Manual

Atmospheric relief valve type 1100 Installation and maintenance instructions

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

What is pressure relief valve? Pressure relief valve

TECHNICAL DATA. Q = C v P S

0311T. General Installation and Maintenance Instructions

Anti-flood device Model B-1

Speed control assembly model A-1

1800C and 1800C-HC Series Service Regulators

ASME SECTION I & VIII STEAM, AIR AND GAS SERVICE. 119 series cast iron flanged safety valves

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

TECHNICAL DATA CAUTION

TECHNICAL DATA. Q = C v P S

Types S100K and S102K Pressure Regulators

WHEATLEY Series 500 Swing Check Valve

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

TECHNICAL DATA. Q = C v P S

1805 Series Relief Valves

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

WHEATLEY Series 822/820 Swing Check Valve

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA ACCELERATOR MODEL E-1

! WARNING. Before using this product read and understand instructions.

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Safety Valves. Expertise and solutions for steam, gas and liquid applications MECHANICAL SOLUTIONS

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

TITAN FLOW CONTROL, INC.

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Your safety and the safety of others are very important.

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

TITAN FLOW CONTROL, INC.

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Combination Air Valve

ELKHART BRASS MANUFACTURING COMPANY

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

MANUAL. Sesame. Thermoplastic Tank Technologies

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

WKM Model 320F Floating Ball Valve

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

Manual Actuated Boiler Blowdown Valves

PRESSURE RELIEF DEVICES. Table of Contents

776 Cryogenic Safety Valve

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

III. Identify the initial installation requirements for standpipe systems

TECHNICAL DATA. Q = C v P S

756 Safety Relief Valves

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Q = C v P S

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

Bermad Pressure Reducing. Model: 42T

TECHNICAL DATA. Trimpac 256a. October 31, 2013

INSTALLATION, OPERATION and MAINTENANCE MANUAL

R600 and HSRL Series Instruction Manual

Installation Instructions

GENERAL DESCRIPTION MODEL RCW DRY SYSTEM CONFIGURATION. Technical Support Airpark Dr. Standish, MI 48658

Related Products: Auto Drain Valve. Model/Specifications. Model

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

TECHNICAL DATA. Q = C v P S

1305 Series Pressure Reducing Regulators

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Installation, Operation, and Maintenance Manual

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

Pressure Relief Device Investigation Testing Lessons Learned

Float Operated Level Controllers

Installation, Operation and Maintenance Manual for Back Pressure Regulator

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

RELIEF VALVES IN PARALLEL

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

INSTALLATION / OPERATION / MAINTENANCE INSTRUCTION

DS05C,D,G Dial Set Pressure Regulating Valves

Noth American 7347 High Pressure Gas Regulators

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Dry 132a. October 1, 2008

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

Model: 43T. Bermad Pressure Relief Valve

Wet pipe low flow foam/water system

Instructions for Installation, Operation, Care and Maintenance

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

! WARNING. Before using this product read and understand instructions.

TECHNICAL DATA. than the water inlet pressure to the concentrate

Technical data. Back pressure limit: 27.5% of set pressure. Capacity certification: ASME Boiler & Pressure Vessel Code Section I and VIII

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

Transcription:

R Manufactured by Conbraco Industries, Inc. 10-600 SERIES SAFETY VALVE INSTALLATION, OPERATION, & MAINTENANCE Part I Document Number: ES-1325 Revision Level: B Issued By: T.HAMILTON Date: 3/3/16 Approved By: Date: Conbraco Industries, Inc. P.O. Box 247 Matthews, NC 28106 (704) 841-6000 Fax (704) 841-6020 http://www.apollovalves.com

Table of Contents Maximum Pressure/Temperature Chart... 2 Installation Instructions... 3 Operating Instructions... 3 Maintenance and Testing Instructions... 4 10-600 Series Part Number Matrix... 4 Nameplate Information... 5 Amendment Register... 6 IMPORTANT Conbraco pressure relief valves are safety devices designed for the protection of lives and property. These valves will provide years of service when properly installed and maintained. The information contained herein is intended for use by qualified personnel to properly maintain these devices. Serious property damage and injury or death may occur should a pressure-relieving device fail to operate correctly. Any installation, maintenance, adjustment, repair or testing should only be performed by experienced personnel properly trained and qualified in accordance with applicable codes and standards. When maintaining or repairing Conbraco pressure relief valves, use only original Conbraco parts to ensure safe and reliable operation. Contact your local Conbraco factory representative for the name of a factory authorized repair center near you. Or visit us on the web at www.apollovalves.com. Maximum Pressure/Temperature Chart Warning Application must not exceed the pressure/temperature limitations below. Series 10-600 Max. Set Max. Temperature 160 psig (11 barg) 250ºF (121ºC) ES1325, IOM, 10-600 Series Rev. B 2

Installation Instructions This quality Conbraco safety valve, along with proper installation, use and maintenance will provide many years of reliable service and protection against excessive pressure build-up of water and steam. Use of this valve for any other purpose or media places all responsibility upon the user. Before installing valve, or operating equipment to which it is installed, read all instructions carefully. Caution - Always wear proper safety equipment. Caution Valve may be very hot to the touch. Wear protective equipment if necessary. 1. Installation must be performed by qualified service personnel only. 2. It is the piping system designer s responsibility to implement appropriate protective measures to minimize reaction forces and moments which result from supports, attachments, piping, etc. 3. Service is to be compatible with the materials of construction. Prior to selection, it is the user s responsibility to determine that the valve is appropriate for the intended application. Application not to allow corrosion >.001 /year (.025 mm/year). 4. The capacity rating of this valve must equal or exceed that of the equipment to which it is installed. 5. Do not use this valve on a coal or wood-fired boiler having an uncontrolled heat input. 6. Do not use the test lever as a lifting device during installation. 7. Insure that all connections, including the valve inlet, are clean and free of any foreign material. 8. Use pipe compound sparingly or tape on external threads only. 9. Do not use a pipe wrench! Use proper type and size wrench on wrench pads only. 10. This valve must be mounted in a vertical upright position directly to a clean tapped opening in the top of the pressure vessel. Under no circumstances, should there be a flow restriction or valve of any type between the safety valve and pressure vessel. 11. See ASME Boiler and Pressure Vessel Code and local jurisdiction for additional installation and operating instructions. Caution - During operation, this valve may discharge large amounts of hot, high-pressure steam or water. To reduce the potential for bodily injury and property damage, a discharge line must be installed that: a) is connected from the valve outlet to a safe point of discharge with no intervening valve; b) allows complete drainage of the valve and discharge line; c) is independently supported and securely anchored to avoid applied stress on the valve; d) is as short and straight as possible; e) terminates freely to atmosphere where any discharge will be clearly visible and is at no risk of freezing; f) terminates with a plain end that is not threaded; g) is, over its entire length, of a pipe size equal to or greater than the valve outlet. Use only schedule 40 pipe for discharge. Do not use schedule 80, extra strong or double strong pipe or connections. Do not cap, plug or obstruct discharge pipe outlet! If discharge is piped upward, a condensate drain must be provided in the elbow below the vertical pipe to prevent condensate from returning into the valve. A Conbraco Drip Pan Elbow is ideal. Operating Instructions If adding water to a boiler, do not allow water to flow through safety valve as sediment or debris may be deposited on seating surfaces. To achieve topmost performance and maximum service life, it is necessary to maintain a proper pressure margin between the set pressure of the safety valve and the operating pressure of the equipment. The minimum recommended operating pressure margin for this type of safety valve is 10 psi or 25% of set pressure, whichever is greater. Failure to maintain this operating margin may result in leakage past the seat and an accumulation of deposits on the seating surface. Excessive deposits may prevent the safety valve from operating properly, and a dangerous pressure build-up and equipment rupture may result. ES1325, IOM, 10-600 Series Rev. B 3

Maintenance and Testing Instructions CAUTION! Before testing, make certain discharge pipe is properly connected to valve outlet and arranged to contain and safely dispose of discharge (see Installation Instructions). Under normal operating conditions a try lever test should be performed biannually in steam service, with a visual inspection every 2 months and an annual pressure test. In air/gas service, perform a visual inspection every 6 months, a lever test annually and a pressure test every 3 years. Under severe service conditions or if corrosion, pitting, and/or deposits are noticed within the valve body, testing must be performed more often. A try lever test should be performed at the end of any non-service period. CAUTION! High sound levels may be experienced during lever test. Wear proper safety equipment and exercise extreme care. Test at or near maximum operating pressure by holding the test lever fully open for at least five seconds to flush the valve seat free of sediment and debris. Then release lever and permit valve to snap shut. If lift lever does not actuate, or there is no evidence of discharge, turn off equipment immediately and contact a licensed contractor or qualified service personnel. For resetting, adjustment or repairs contact Conbraco Industries for the appropriate service facility. Neither Conbraco Industries, Inc. nor its agents assume any liability for valves improperly installed or maintained. 10-600 Series Part Number Matrix EX: 1060612 POSITION OPTION 1-3: SERIES # 10-600 SERIES 4-5: INLET x OUTLET 04 = 3/4 x 3/4 14 = 3/4 x 1 05 = 1 x 1 15 = 1 x 1-1/4 06 = 1-1/4 x 1-1/4 16 = 1-1/4 x 1-1/2 07 = 1-1/2 x 1-1/2 17 = 1-1/2 x 2 08 = 2 x 2 18 = 2 x 2-1/2 6-7: SUFFIX SET PRESSURE DESIGNATION, SEE TABLE PRESSURE, PSIG SUFFIX PRESSURE, PSIG SUFFIX PRESSURE, PSIG SUFFIX 15 01 65 13 115 23 20 02 70 14 120 24 25 04 75 15 125 25 30 05 80 16 130 30 35 06 85 17 135 31 40 07 90 18 140 32 45 09 95 19 145 33 50 10 100 20 150 34 55 11 105 21 155 35 60 12 110 22 160 36 ES1325, IOM, 10-600 Series Rev. B 4

Nameplate Information ASME Code Symbol The ASME HV symbol signifies the valve has been designed, manufactured, and tested in accordance with Section IV of the ASME Boiler and Pressure Vessel Code and is approved for use on heating boilers. NB Symbol This symbol indicates the capacity value stamped on the nameplate has been certified by the National Board of Boiler and Pressure Vessel Inspectors. CRN This number is the design registration number in accordance with CSA B51, the Canadian Boiler, Pressure Vessel and Pressure Piping Code. MODEL (10-) This is the valve model series number as described in the Part Number Matrix. CAP This is the approved capacity of the valve, btu/hr and kcal/hr. SET This is the set pressure of the valve in pounds per square inch and bar gauge. SIZE This is the inlet size of the valve in inches. TS This is the maximum allowable temperature, degrees Celsius. DN This is the metric size designation of the inlet. DATE This is the date of manufacture. The first two numbers indicate the year (04=2004), and the last two numbers indicate the week of the year (13=13 th week of the year). CONBRACO INDUSTRIES, INC. M ADE IN U SA MODEL RVW60 10 SIZE PSIG BTU/HR HV BARG KCAL/HR DATE A S M E DN CRN 0G8547.5C TS 121 C R N ES1325, IOM, 10-600 Series Rev. B 5

Amendment Register DATE REV PAGES DESCRIPTION 10/21/2008 A ALL NEW RELEASE 3/3/16 B 5 UPDATED NAMEPLATE ES1325, IOM, 10-600 Series Rev. B 6