AIRMASTER SERIES RF AUTOMATIC DEWATERING VALVES. For the purging of water from compressed air systems WHERE DO YOU NEED AUTOMATIC DEWATERING VALVES

Similar documents
Installation Instructions JATCO Environmental Protection Tank Model J-7000

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Pressure reducing valves Index

MAINTENANCE AND OPERATING MANUAL

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

ACCU-MIX 1200 / / 26270

Model 9201E Tempered Water Blending System

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

IFS NUVENT SERIES IWF FOR POTABLE WATER ANTI SLAM AIR RELEASE AND VACUUM BREAK AIR VALVES

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

SPECIFICATIONS - DETAILED PROVISIONS Section Butterfly Valves C O N T E N T S

STC 2KS/2KD Series Stainless Steel Angle Seat Valve

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Rate of Flow Valve Series 120

CSA Sample Draw Aspirator Adapter Operator s Manual

HYDROVEX TTT Membrane Flow Regulator

ASSE International Product (Seal) Listing Program. ASSE Performance Requirements for Air Valve and Vent Inflow Preventer

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Price Schedule # Effective: MAy 5, 2014

TEST SPECIFICATION NYT-909-C

Masoneilan* 78 Model Air Filter Regulator

Index Table. Model 794. Installation, Operating and Maintenance Instructions

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

ASME SECTION I & VIII STEAM, AIR AND GAS SERVICE. 119 series cast iron flanged safety valves

FLANGED TWO-PIECE BALL VALVES

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Air Eliminators and Combination Air Eliminators Strainers

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

TECHNICAL DATA. Trimpac 244a. September 16, 2013

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Standard Terms and Conditions

92831 TEL: (714) FAX:

Eaton Filtration, LLC

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

TECHNICAL DATA. than the water inlet pressure to the concentrate

VERTICAL BLADDER TANK

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

CAST IRON SAFETY VALVE TYPE 6301

Model 4000 Pressure Controller

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

Eaton Filtration, LLC

THE PERFECT PRESSURE DROP TRAP PRIMER

CF-SERIES HIGH FLOW REGULATORS

HORIZONTAL BLADDER TANK

Hygienic Bubble Trap Installation and Operations Manual

EQUIPMENT Operation Manual. Loctite Stainless Steel Poppet Valve Part Number

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

DECLARATION OF INCORPORATION

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

RK-IR Sample Draw Aspirator Adapter Operator s Manual

453 Series Steam Heated Vaporizing Regulator

FLANGED TWO-PIECE BALL VALVES

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 256a. October 31, 2013

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Model 420-HY Pressure Regulating Hydrant Valve

Unit 24: Applications of Pneumatics and Hydraulics

Thermocirc Installation and Maintenance Instructions

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref:

Sample Concentrator SBH CONC/1 Instructions for use

Rust Handler TM. Drain-All, Inc. Quality System ISO 9001:2008 Certified INTRODUCTION

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

AND OPERATION INSTRUCTIONS

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

REFRIGERATION SYSTEM COMPONENTS

STAP. Differential pressure controllers DN , ANSI flanges

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Nitrogen Supply System

92831 TEL: (714) FAX:

HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1,

SCA Series Inverted Bucket Steam Traps

776 Cryogenic Safety Valve

STAP. Differential pressure controller DN

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

CAST IRON VALVES FLOAT VALVE

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

TECHNICAL DATA. Page 1 of 12

This document to be used with Hurley traditional Davits

Transcription:

R SERIES RF AUTMATIC DEWATERING VALVES For the purging of water from compressed air systems The series RF is a high capacity automatic dump valve specifically designed to continuously purge water from compressed air systems, thereby preventing loss of system capacity or damage to pneumatic equipment. Properly installed these valves have proven to be extremely reliable and efficient whilst requiring minimum maintenance. Their high discharge rate ensures that water is never allowed to accumulate at potential collection points along pipelines or under pressure vessels. Unlike mechanical water traps which have very low discharge rates due to an operating principle that limits the discharge port to comparatively small sizes, the dump valve can accommodate a large bore discharge because of it's superior pneumatic operation. This combined with a large integral water reservoir and an actuating mechanism that will not allow loss of water makes the way a very cost effective de - watering method. The series RF standard range consist of 40mm(1 1/2") or 25mm (1")discharge models with, 5, 5 litre or 0, 5 litre reservoirs and for a maximum working pressure of 10 bar (150 psi). They are supplied with screwed connections to BSP or NPT standards in sizes 50mm (2") and 15mm (1/2") suitable for installation under pipeline or in - line for smaller diameter pipe work. W D YU NEED AUTMATIC DEWATERING VALVES AIR RETICULATR DRYER INSTRUMENT MANIFLDS AIR VESSELS AIR CMPRESSR page: 1

A. B. 2 2 3 1 3 5 5 4 A. Upon commissioning, small amounts of air and water will continuously discharge from the needle valve (4). The volume of air discharged is very small and is just sufficient to maintain a differential pressure to keep the Dump Valve (5) closed. Condensate enters the Control Float Chamber (1) and buoys the Control Float (3). B. The Control Float (3) is buoyed as water accumulates in the Control Float Chamber (1) and seals off the Small rifice (2). This cuts off the air supply to the Dump Valve (5). Pressure exerted by the water in the Control Float Chamber (3), opens the Dump Valve, discharging the accumulated water. The frequency of operation will be dependant on the location of the valve (see page 1), rate of flow and, pressure and temperature variations. page: 2

MATERIAL SPECIFICATINS 0.5 Litre Capacity Coupling Clamp Cast Steel - Galvanized Control Chamber Cap Mild Steel - Galvanized 0 90 Compression Fitting Nozzle Nozzle Seat Natural Rubber Strainer - Nickel Plated Control Float High Density Polyethylene Valve Body Mild Steel Fusion Bonded Epoxy Powder Coated Connection Tube Rubber Compression Fitting 3 Way Tee Needle Valve Automatic Dump Valve Cast Iron page: 3

MATERIAL SPECIFICATINS 5.5 Litre Capacity Strainer Cast Iron - Galvanized Coupling Clamp Cast Steel - Galvanized Control Chamber Cap Mild Steel - Galvanized Blow off Cock - Nickel Plated 0 90 Compression Fitting Nozzle Nozzle Seat Natural Rubber Control Float High Density Polyethylene Valve Body Mild Steel Galvanized Connection Tube Rubber Compression Fitting 3 Way Tee Needle Valve Automatic Dump Valve Cast Iron page: 4

GENERAL SPECIFICATINS 0.5 Litre Capacity 446 446 59 81 211 Type: Large Capacity Dump Valve Inlet Connection: Screwed 1/2 BSP Female utlet Connection: Screwed 1 BSP Female Accumulator Capacity: perating Pressure Range 0.5 Litre Min. 100 kpa Max. 1000 kpa perating Temperature Range: 5 C to 55 C Model No.: Weight: 015 RF 1003 6 kg. page: 5

GENERAL SPECIFICATINS 5.5 Litre Capacity 820 220 220 Type: Large Capacity Dump Valve Inlet Connection: Screwed 2 BSP Female utlet Connection: Screwed 1.5 BSP Female Accumulator Capacity: perating Pressure Range 5.5 Litre Min. 100 kpa Max. 1000 kpa perating Temperature Range: 5 C to 55 C Model No.: Weight: 050 RF 1003 18 kg. page: 6

CNDITINS F SALE Sale of equipment is subject to the purchaser's acceptance of the company's STANDARD CNDITINS F TENDER AND SALE a copy of which is available on request. Specific attention is drawn to the following extracts. CNTRACTUAL LIMITATINS: The 'Company's' supply is limited to such equipment, accessories, work and documentation as is specified in it's quotations. DRAWINGS AND DATA: All drawings, illustrations, descriptive literature, technical data or particulars of mass and dimensions accompanying the 'Company's' quotations must be considered approximate except when specifically certified. TESTS: The goods will be tested in accordance with the specifications of the 'Company's' tender and/or relevant standard specifications as stated therein. AVAILABILITY: (a) ffers for equipment available exstock are subject to such stock remaining unsold at time oforder placement. (b) Delivery periods quoted are based on the manufacturing position at the time of quotation. Whilst every endeavour will be made to maintain such deliveries, no liability shall be accepted by the 'Company' for delay due to causes beyond it's control. (c) R SERIES RF AUTMATIC DEWATERING VALVES The 'Company' shall only accept liability for late delivery where the 'Company's' liability for such late delivery is not excluded in terms of the foregoing and where the 'Company' has specifically agreed in writing to the payment of a penalty or liquidated damages or damages for such late delivery. In which case the 'Company's' liability shall be limited to the amount so agreed. DELIVERY The 'Company' will deliver, where provided for, to a destination named in it's quotation at which point the 'Company s responsibility for the goods will cease. PACKING: Where the 'Company' deems goods vulnerable to damage during transit, the Company' reserves the right to pack such goods in suitable protective packaging or crates at the Purchaser's cost. Invoices for packing will be substantiated by a copy of relevant documentation from the packaging contractor. PRICE BASIS: Prices are referenced from the 'Company's' valid lists or from the 'Company's' written or verbal quotation exclude packaging and delivery. PAYMENT TERMS: Without exception, payment for all goods and services shall be received by the 'Company' not later than 30 (THIRTY) days subsequent to the date of statement. Interest at prime lending rate + 2% shall be charged on all overdue amounts. TITLE: wnership of all goods supplied by the 'Company' will not pass to the purchaser or any other party until paid for in full and until such time. the 'company' shall be entitled to re - possess the goods whether affixed to immovable property or not. All such goods shall be deemed to be removable property and severable from immovable property. TENDER/ QUTATIN VALIDITY: Written or verbal quotations will be held valid for a maximum of 30 (thirty) days unless contradicted in writing by the 'Company'. RETURNS FR CREDIT: Acceptance of goods returned will be entirely at the discretion of the 'Company' and subject to a minimum restocking charge equal to 15% of the gross invoiced value of such returned goods. LIMITED LIABILITY: The 'Company' shall not be liable for any incidental or consequential loss or damages or expense arising directly or indirectly from the use of any goods supplied, nor shall liability be accepted for any labour or other expenses incurred. The 'Company's' liability is limited solely to the terms of it's guarantee. WARRANTY (a) The 'Company' guarantees that the goods supplied will conform to specifications and to any requirements specifically accepted by the ' Company' in writing in regard to each order but, except as aforesaid, the 'Company' gives no warranty, express or implied, of the material workmanship or fitness of goods for any particular purpose whether such purpose is known to us or not. In accordance with the specifications or requirements aforesaid, or should defects under proper use appear in the goods within a period of 12 (TWELVE) calendar months after the goods have been delivered, caused solely by faulty design, materials or workmanship, we shall, if requested to do so within a reasonable time, but not later than 18 (EIGHTEEN) calendar months, from date of delivery, repair such goods or the defective parts thereof, free of charge by supplying other goods or replacement parts at the initial place of delivery which do comply with specifications or requirements aforesaid and/or which are free of the defects complained of. DISTRIBUTED BY: (b) It is a condition of this guarantee: (i) that any defective parts are returned to the 'Company's' works at the purchaser's expenses and; (ii) in respect of parts or components not of the 'Company's' manufacture, the 'Company's' guarantee shall be limited to the guarantee, if any which we may have received from the supplier of such parts or components in respect thereof so that the 'Company's' liability in terms of such guarantee shall be no greater than the 'Company's' liability in terms of the 'Company's' own guarantee as set out in this clause; (iii) the 'Company' shall be given reasonable time and opportunity to comply with the terms of the guarantee before you call on the 'Company' to pay any sums in respect of the liquidated damages and; (iv) save as provided in the clause, the 'Company' shall be under no liability, whether in contract, delict or otherwise in respect of defects in goods deliver ed, or for any injury, damage or loss resulting from defect or from any work done in connection therewith. VENT--MAT P.. Box 5064 Benoni South, 1502 South Africa Tel: (+27 11) 748 0200 Fax: (+27 11) 421 2749 Revised May 05 Catalogue No. RF 0003