Detector Tubes and Badges

Similar documents
Proper Detector Tube Use Ensures Reliable Indication of Gas Concentration

1. Compute the TWA for the following respirable dust exposures:

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Cambridge Refrigeration Technology

Technical Manual. Sensepoint XCD Gas Detector

Chapter 4: Monitoring and Sampling. Chapter 4: Monitoring and Sampling

Gas Detection. Portable Gas Detection for Safety in Confined Spaces

AirCheck Kit Model K901

Atmospheric Hazards. Hazardous Atmosphere 3/29/2017. Oxygen deficiency and enrichment Flammable gases and vapors Toxic contaminants

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Draeger-Tube and Pump Training Program

Columbus Instruments

FOR SAFE AND CORRECT USE

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Applications Note: Use of "pentane equivalent" calibration gas mixtures

Calibrate or Die! Calibration Types

FROG-4000 TM Chemical Analysis System

PRECISION GAS MIXTURES

Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03

AND EQUIPMENT FOR ENVIRONMENTAL APPLICATIONS (800) B Polk Street Houston, TX

MMS Mercury Monitoring System for Natural Gas

Nonrefillable Cylinders

FROG-4000 TM Chemical Analysis System

Generating Calibration Gas Standards

Application Note AN-107

Gas-Detection Instruments

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

PreSens. Manual OxoPlate. OxoPlate OP96C. PreSens Precision Sensing

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Register your instrument! Eppendorf Research plus. User Adjustment

VHP Vaporized Hydrogen Peroxide monitoring GAS DETCTION SYSTENS. Dräger. Technology for Life

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

acrolein, acetaldehyde and acetone( cm -1 ); methanol (1306 cm -1 ); ethylene (949 cm -1 ); and isoprene (893 cm -1 ).

CSA Sample Draw Aspirator Adapter Operator s Manual

Airtester HP for compressed air according to EN 12021

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Met One E-BAM Particulate Monitor

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

Calibration of a GC955

Advanced Test Equipment Rentals ATEC (2832)

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

FROG-5000TM Chemical Analysis System User s Manual

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

D. De La Matter 2004 Swimming Pool Chemistry STUDENT ACTIVITIES:

Mitigation Starts With Design! Continues with Safe Operation, Mechanical Integrity and Training!

Gas monitoring using GASMET FTIR

Description Advanced Features Typical Applications

Gaseous oxygen technical grade Specification

School of Chemistry SOP For Operation Of Glove Boxes

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

Gas Mixture Two Components. Gas Mixtures Two Components

Garrett Gas Train Instruction Manual

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Phosgene Sensor. Sensoric COCl2 3E 1

DEMONSTRATION 2.1 PROPERTIES OF CO 2. Chapter 2: Gases

Standard Operating Procedure for H 2 S and SO 2 Converter

Rare Gas Applications

SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL

Automatic Isokinetic Sampler. ST5 Evo

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Experiment 18 Properties of Gases

Environmental. Gas Canister sampling and analysis. EQLF, Cambridge, July 20 th Right Solutions Right Partner

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

Selecting Respirators and Associated Equipment Monthly webinars from AFS- PROPOSED SCHEDULE

Zebron Gas Management

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Vehicle and Engine Emissions Testing

6890 GC Site Preparation

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Gas Metrology. SI-traceable: Primary Reference Materials Certified Reference Materials Calibrated Gas Mixtures Interlaboratory Comparisons

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

Air Quality 2b - PFGC/FID Analysis of Benzene and Toluene in Automobile Emissions

MODEL RP050BMST RESPIRATORY PROTECTOR MANUAL

Isoflurane: Safe Use Guidelines. (2-chloro-2-(difluoromethoxy)-1,1,1- trifluoro-ethane) is a halogenated ether used for inhalational anesthesia.

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

AUK Environmental Sensor. Determining the refractive index of the air. AUK Environmental Sensor

Pharmaceutical Grade Nitrogen & Gardner Denver / CompAir PSA Nitrogen Gas Generation Systems

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

Technical Data Sheet MF010-O-LC

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

A. Evaluation of the written program

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

All Sixth Sense cells for toxic gas detection are based on electrochemical principles and can be classified as amperometric fuel cells.

Oxygen Measurement in Natural Gas

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

Calibration Requirements for Direct Reading Confined Space Gas Detectors

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

SENSOR MANUAL Document No M (Revision L)

This test shall be carried out on all vehicles equipped with open type traction batteries.

SURVEYING THE HAZARDOUS MATERIALS INCIDENT

USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases)

Register your instrument! Eppendorf Xplorer / Eppendorf Xplorer plus. Adjustment

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

What I have learned about SF 6 gas testing.a Practical explanation

GAS DETECTION: CALIBRATION GAS

Transcription:

Detector Tubes and Badges 1 Detector Tubes Elements of detector tube system Types of tubes Active (short- and long-term) multi-level Passive (diffusion controlled) References: pp. 692-708 in Perkins Overview of Available Devices 2 CIH 1

Volumes drawn through tube Generally manually powered pumps (like bicycle pump) with highly precise volume -- usually 1 Liter. Often a single stroke but can be multiple strokes Multiple strokes to detect lower concentrations and for some chemicals 3 Detector tube pumps Piston-type (MSA, Gastec) Bellows-type (Draeger) Continuous, battery-operated 4 CIH 2

Long-term sampling Use battery-powered pump drawing air at a slow rate 5 Calibrating Hand-Pumps Check for leaks by connecting pump to unbroken detector tube. When attempt to pump air, none should flow If pump fills or the pressure changes over time, then there is a leak. Or, connect to bubble burette through opened detector tube and length of tubing. Manipulate so that bubble is at zero or note initial bubble height Draw volume through pump Note burette bubble new location and compute volume Compare to specified value Connect Lock Unlock 6 CIH 3

Reading stain length The correct reading in all cases is 5%. When the color change is pale, read the value in the middle between the end of the dark layer and the end of the pale layer. When the end of color change is slanted, read the value in the middle of the slant, here 5% If even stain length, just interpolate. 7 Sensitivities for Various Detector Tubes PART # (50/pack) ANALYTE THRES- HOLD LEVEL MINIMUM DETECTABLE CONC. IN 8 HOURS (PPM) MRST* (HRS) SRST* (MINS) CROSS SENSI- TIVITY 382010 Ammonia 4.0 ppm/hr 0.50 ppm 48 15 Aliphatic amines 382017 Carbon 8,000 1 ppm 10 15 Acid vapors Dioxide ppm/hr 382012 Carbon Monoxide 7 ppm/hr 1 ppm 10 15 Alkenes, H 2, H 2 S 382009 Chlorine 0.2 ppm/hr 0.025 ppm 48 15 Br 2, HCl, I 2 382003 Chlorine/Chlor ine Dioxide Cl2: 0.18 ppm/hr Cl2: 0.025 ppm Cl 2 : Br 2, HCl, I 2 ClO2: 0.2 ppm/hr ClO2: 0.025 ppm 10 15 ClO 2 : NO 2, high conc. 382019 Dimethyl 5 ppm/hr 0.625 ppm 48 15 R 2 NH Amine 382018 1,1-Dimethyl Front: 30 Front: 3.75 ppb Hydrazine ppb/hr Back: 10 ppb/hr Back: 1.25 ppb 48 5 High conc. N 2 H 4 382002 Hydrazine 8.0 ppb/hr 1.0 ppb 48 15 MMH O 3 8 CIH 4

Detector Tubes Issues Specificity Flow rate and behavior (interchangeability) Shelf life Performance limitations: pressure, temperature, relative humidity Certification of Detector Tubes NIOSH Specifications (pre-1985) Safety Equipment Institute (SEI) 9 Safety Equipment Institute What is SEI? Private, nonprofit organization established in 1981 Third-party certification programs to test and certify a broad range of safety and protective products. Certification program accredited by the American National Standards Institute (ANSI) in accordance with the Standard ANSI Z34.1-1993, Third Party Certification Programs for Products, Processes, and Services. Policy decisions are handled by SEI s Board of Directors which includes representation from organized labor, users of safety equipment, the insurance industry, the fire service, and a safety equipment manufacturer. What Does SEI Do? Assist government agencies along with users and manufacturers of safety equipment in meeting their mutual goal of protecting the workers and consumers with safety equipment in keeping with recognized standards and the current state of the art. Who Can Participate in SEI Certification Program? Certification programs are voluntary and available to any manufacturer of safety equipment seeking to have product models certified by SEI. What Are the SEI Certification Programs? SEI certification programs include on-going product testing and quality assurance audits which qualify a product model for SEI Certification. SEI will certify the manufacturer s product model and grant the right to use the SEI certification label when (1) the testing lab has determined that the product model has been tested and successfully meets the appropriate product standard, and (2) the quality assurance auditor has determined that the manufacturer complies with SEI quality assurance requirements. 10 CIH 5

Information on the tubes See folded sheet inside box Instructions and info on tube, itself 1 2 4 3 5 6 Note that some tubes used with pre-filter tube 11 Attachment clip 5 Direction arrow 2 Absorption layer 4 (molecular sieve) Pre-filter for water and CO2 3 Breaking bead 1 Breaking hinge 6 Clip for diffusion tube 7 Design of nitrous-oxide diffusion sampler Tube ready for operation 8 1998-2006 Steven Guffey, PhD, 1 CIH 2 Inlet opening 3 12 CIH 6

Perchloroethylene 10/b Standard measuring range: 10 to 500 ppm Number of strokes (n): 3 Time for measurement: app. 40 s Standard deviation: +/- 15 to 20% Color change: grey--orange Ambient operating conditions Temperature: Absolute humidity: 15 to 40 C 5 to 12 mg H 2 O/L Reaction principle a) CCl 2 =CCl 2 + MnO 4 - Cl 2 b) Cl 2 + o-tolidine- orange reaction product Cross sensitivity Halogenated hydrocarbons and free halogens are indicated. Petroleum vapors reduce the perchloroethylene indication. 10 25 50 100 200 300 400 500 ppm oxidation layer grey indicating layer 13 Toluene 5/b Standard measuring range: 50 to 300 ppm/ 5 to 80 ppm Number of strokes (n): 2 / 10 Time for measurement: app. 1 min / app. 5 min. Standard deviation: +/- 10 to 15% Color change: white pale brown 5 10 20 white prelayer Ambient operating conditions Temperature: Absolute humidity: Reaction principle Toluene + I 2 O 5 + H 2 SO 4 I 2 2 to 40 C max. 20 mg mg H 2 O/L 30 40 50 60 70 80 Cross sensitivity 10 ppm pheno l, 1000 ppm acetone, 1000 ppm ethanol and 500 ppm octane are not indicated. Xylene (all isomers) and benzene are indicated with the same sensitivity. The discoloration in the presence of p-xylene is violet, and yellowish-green with benzene. ppm white indicating layer 14 CIH 7

Other Direct Reading Devices Devices based on color development Passive Active: GMD Sure-Spot Precision and accuracy issues with inexpensive monitors When to use indicator tubes/badges 15 Diffusion Badges Molecular collisions drive flow of contaminant molecules into badges. Activated charcoal adsorbs, so flow is one-way. Must have some air movement to avoid depletion. Body movement adequate. 16 CIH 8

SafeAir Badges Slide badge into comparator. Turn color wheel until scale matches color formed on badge. Read exposure dose. 17 Use of Badges Unseal pouch Mark id and start time Place on worker Remove and mark stop time Seal with provided o-ring and cap 18 CIH 9

Calibrating/Testing Using bubble burette or large syringe, inject known amount of clean air into bag. Using very small syringe, extract air or liquid having known concentration and inject it into the bag Compute expected concentration Connect detector tube to exhaust port from bag and draw mfg. s specified air through the detector tube. Note value from detector tube. Repeat with larger and larger quantities of contaminant injected and checked with different detector tubes. 19 The End 20 CIH 10