Current Leads for Cryogenic Systems

Similar documents
RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

SPECIFICATION FOR AN MRBR 9.4 TESLA/310MM/AS CRYO-COOLED MAGNET SYSTEM

JANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS

Microscopy Cryogenic WORKSTATION. Performance by Design

Variable Temperature Storage Dewar Mount Inserts

CRYO INDUSTRIES. Liquid Helium Research Dewars

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

Cryostream 800 Series

EXPERIENCE WITH A PRE-SERIES SUPERFLUID HELIUM TEST BENCH FOR LHC MAGNETS

Magnet and RF Cavity Test Stand Design. Tom Peterson, SLAC USPAS January, 2017

PRESSURE DIFFERENTIAL PRODUCTS 2008 TRICO CORPORATION. ALL RIGHTS RESERVED.

CRYO. SuperVariTemp Magnet Inserts

MEDICAL EQUIPMENT CATALOG

ATL. Take Control of your Helium Supply. Advanced Technology Liquefier The next generation of helium recycling

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Check with local zoning official for property line distance requirements.

Major Design Features

CSA Sample Draw Aspirator Adapter Operator s Manual

TYPE 7800 SERIES 7848D/7848W UNIVERSAL VESSEL SEAL Technical Specification

Flow Sensors & Hydrometers Specification Sheet

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler

May08 Rev B

How to specify a product. Process Sensors and Mechanical Instruments

v. Size shall be specified on drawings.

Precision Liquid Settlement Array Manual

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

Baffles and Traps Cryotrap

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

Products for Cryogenic Applications

Variable Temperature Operation

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Dynamic Operation of a 4 K Pulse Tube Cryocooler with Inverter Compressors

Storage and transfer of cryofluids

Oxygen Contamination

Heliox TM. He systems to suit all applications

High-performance submersible pressure transmitter For level measurement Model LH-10

ASME Boiler & Pressure Vessel Code Analysis of the 1497 MHz High-Current Cryomodule Helium Vessel

Status on the DFBXF commissioning

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

TYPE 7828G/7828GD 7800 SERIES UNIVERSAL VESSEL SEAL Technical Specification

Cryogenic Liquid Ultimate Liquid Cylinder Hose

Customer Responsibilities

Load Responsive Multilayer Insulation Performance Testing

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Dilution Refrigerator manual

Description Advanced Features Typical Applications

Liquid Helium Bath Cryostat

Vacuum Jacketed Piping Solutions

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

UltraLo 1800 Alpha Particle Counter

Series Environmental Chambers

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Hydro Bond Engineering Ltd Electrical Penetrators: Manned and Unmanned Systems HPS (Hydro Bond Penetrator Series)

Buying more than 11 gauges? Call Lesman for additional discounts.

EXPERIENCE WITH CRYOGENICS SAFETY, PROBLEMS AND SOLUTIONS

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

Table of Contents Want full page pictures with most important parts labeled in the beginning.

COMPRESSED AIR DISTRIBUTION SYSTEMS

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.

Overview of Earlier Lecture

Design Features. General Description

GM Series Dual-Block Multi-Function Gas Control Valves

MODEL WEIGH MODULE

THE PROCESS OF JOINT INTEGRITY

[USING THE VITROBOT April 9, Using the Vitrobot

Development Of The Compressor For Miniature Pulse Tube Cryocooler

Rosemount 3159 Nuclear Qualified Remote Diaphragm Seal

Risk Assessment for ITER TF Coil Manufacturing )

Torque Tube TB300 Digital Transmitters

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

SCA Series Inverted Bucket Steam Traps

AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER

Bruker BioSpin NMR CASE. System Requirements Manual. Version. NMR Spectroscopy. think forward

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

High Precision Gauge Pressure Indicators

Model 6812C Dual Lane Scoreboard Owner s Manual

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

Customer Responsibilities

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Rev. 1. Cryogenics Thermoflasks. 2122, 2123, 2124, 2129, and 2130

National Accelerator Laboratory

GAS FUEL VALVE FORM AGV5 OM 8-03

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

First Experimental Data of the Cryogenic Safety Test Facility PICARD

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Mass Flow Controller (MFC) for Gases

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Improving distillation tower operation

Differential pressure

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

COMPRESSION TUBE FITTINGS

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Series 8500 Expansion Compensators. Catalog 674H

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

TA-FUSION-P. NPT threads / ANSI flanges

SIMPLAIR PIPING TOOL. JXT Company

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

Transcription:

Current Leads for Cryogenic Systems American Magnetics Inc. s (AMI) Vapor Cooled Current Leads provide reliable and consistent electrical current transfer from room temperature (300K) to a Liquid Helium environment (4.2K). These high efficiency heat exchangers use the heat capacity of cold helium vapor to counterflow the incoming conductive and resistive heat, thereby minimizing the liquid helium consumption. The thermal input of the leads is carefully designed to insure that just enough helium gas is generated to provide adequate cooling across the full range of operating currents. AMI offers a wide range of current lead designs from small current requirements to over 100,000 Ampere leads. FEATURES Ultra hi-efficiency heat transfer Custom designs up to 100,000 Amps Conventional Copper Leads Brass Leads Hybrid HTS Leads Break-Away Leads BENEFITS OF OWNERSHIP Minimize helium usage and operating costs Application flexibility Proven reliability Lower helium usage in standby mode without intervention Lowest helium usage available in a fixed lead configuration Ultimate Minimum helium usage in standby mode APPLICATIONS MRI or NMR Magnetic Energy Storage (SMES) Fusion Energy Accelerators and Colliders Conductor Testing & Characterization HELIUM USAGE Standard AMI vapor cooled current leads (VCCL) have been shown to evaporate approximately 2.8 x 10-3 liters/(hour amp pair) when operated at the rated design current. These leads are expected to provide this performance under normal operating conditions. However, a more conservative value of 3.2 x 10-3 liters/(hour amp pair) is recommended for system design calculations. Helium consumption at zero current is approximately 60% of rated current consumption. Consumption rates assume the use of AMI superconducting bus bars and fixed current leads with soldered connections. These specifications do not apply for breakaway current leads which have a lower consumption rate in standby mode. The use of water-cooled power cables, resistive cold end bus bars, improperly sized bus bars, or high contact resistance joints may cause consumption rates to be higher than those stated above. P.O. Box 2509 112 Flint Road Oak Ridge, TN 37831-2509 Phone: (865) 482-1056 Fax: (865) 482-5472 E-mail: sales@americanmagnetics.com

APPLICATION CONSIDERATIONS VOLTAGE DIFFERENTIAL AMI leads operate with a voltage differential of less than 100 mv as measured from the top of the lead to the bottom, or 200 mv measured between the leads on the warm end. Upon request, voltage tap attachment points can be provided on all lead sizes. The measurement of this value can be a useful tool for detecting insufficient gas flow or an overcurrent condition. System trigger points can be established to take corrective action or shut down the system prior to overheating of the leads for whatever reason. PRESSURE DIFFERENTIAL A typical pressure differential of approximately 2 mm mercury (0.03 psi) is developed through the leads when operating at their maximum rated current for standard lead lengths. ICING & FROSTING Depending upon the operating conditions of the cryogenic system, frosting or icing on or around the top of the current lead may be observed. This may be caused by forcing more cold gas through the leads than is Figure 1: Dimensional References for Standard Vapor Cooled Leads Up to 10,000 Amperes necessary. A common example of this occurs when the background dewar boil-off gas is vented through the leads while in standby mode. Although small amounts of icing or moisture do not generally present a problem, AMI can provide electrical heaters to keep the exposed lead above the freezing point. Special construction techniques are also available to prevent O-rings from freezing on the cryostat mounting flanges. CUSTOM INTERFACES A number of different style interface points are available on current leads. The standard horizontal upper end tab can be rotated to the vertical Flag position in cases where the leads must be mounted very close together. The warm end connection for power cables can be configured with special bolt patterns, large surface area mounting surfaces for low contact resistance, or designed for a circular clamping type connection. Cold end connections are also highly adaptable to suit specific requirements.

Model Number L-50 L-75 L-100 L-150 L-200 L-250 L-500 L-1000 L-2000 L-3000 L-5000 L-10000 Amperes 50 75 100 150 200 250 500 1000 2000 3000 5000 10000 Approx. Helium Consumption, Liters/Hr. (pair of leads) 0.16 0.24 0.32 0.48 0.64 0.8 1.6 3.2 6.4 9.6 16.0 32.0 Type A A A A A A A B B B B B DIMENSIONS IN INCHES A 1/4 1/4 1/4 1/4 3/8 3/8 1/2 1/2 1/2 1/2 3/4 3/4 B 1-1/2 1-1/2 1-1/2 1-1/2 2 2 3 3 3 3-3/4 4-1/2 7 C 1 1 1 1 1-1/4 1-1/4 1-1/2 2 2-1/2 3 3 3-1/2 D -- -- -- -- -- -- -- 1 1 1-1/2 1-1/2 2 E 9/32 9/32 9/32 9/32 9/32 9/32 9/16 9/32 7/16 7/16 7/16 7/16 F 3/8 3/8 3/8 3/8 1/2 1/2 3/4 3/4 3/4 1 1 1 & 3 G 3/8 3/8 3/8 3/8 1/2 1/2 1/2 7/8 1-1/8 1-1/4 1-1/2 2-1/2 H 1/4 1/4 1/4 1/4 3/8 3/8 1/2 1/2 3/4 1 1 1-3/4 I -- -- -- -- -- -- -- 2-1/4 2-1/2 2-5/8 3 3-3/4 J -- -- -- -- -- -- -- 1-3/4 2 2-1/8 2-1/4 3-1/4 K 1/4 NPT 1/4 NPT 1/4 NPT 1/4 NPT 3/8 NPT 3/8 NPT 1/2 NPT 1 1-1/4 1-3/8 1-5/8 -- L 7/8 7/8 7/8 7/8 1 1 1-3/16 5/8 5/8 5/8 5/8 3/8 M 9/16 9/16 9/16 9/16 9/16 9/16 3/4 3/8 3/8 3/8 3/8 -- N -- -- -- -- -- -- -- 9/32 9/32 9/32 9/32 9/32 O 1/4 1/4 1/4 1/4 3/8 3/8 1/2 3/4 1 1-1/8 1-3/8 2-1/8 R -- -- -- -- 0.201 0.201 0.201 9/32 13/32 17/32 17/32 3/8 S 1 1 1 1 1 1 1 1-1/2 1-1/2 1-1/2 1-1/2 4 T 1/16 1/16 1/16 1/16 1/8 1/8 1/8 1/4 1/4 1/4 1/4 3/8 U -- -- -- -- 1/4 1/4 1/4 1/2 1/2 1/2 1/2 1 & 2-1/2 V 16-5/8 16-5/8 16-5/8 16-5/8 16-5/8 16-5/8 17-1/2 19-1/2 19-1/2 19-1/2 19-1/2 24 W Adjust. Adjust. Adjust. Adjust. Adjust. Adjust. Adjust. 1-1/2 2 2 2 4 X 1/4 1/4 1/4 1/4 3/8 3/8 1/2 3/4 1 1-1/8 1-3/8 2-1/8 Y 5/8 5/8 5/8 5/8 1/2 1/2 1/2 3/4 1 1 1 1 VOLTAGE ISOLATION There are at least three areas of concern when dealing with proper voltage isolation of current leads: Isolation from the cryostat Isolation from other leads or structures internal to the cryostat Isolation from any helium gas recovery system. AMI has the capability to address all of these issues. Fiberglass is commonly used on the lead shaft and warm end tabs to isolate the leads from the cryostat and other leads. Flanged ceramic-to-metal type isolators are often used in-line on the gas collection system and are available for most sizes of current leads. High current leads pictured with voltage isolation flanges and tubes installed

APPLICATION EXAMPLES Current lead assembly for Short Sample Test Stand Model of lead operated in vacuum with integral supercon bus bars and Lhe supply canister for wiggler system aphoto of actual leads modeled on left with removable upper tabs detached 120A current lead cluster for Collider 600A current lead cluster for Collider 6000A Helium Gas Cooled Hybrid HTS Lead Assembly for Fusion Device

Model of typical liquid helium cryostat with vapor cooled leads and series superconducting bus bars installed on magnet support stand. Current Leads Liquid Helium Dewar Bus Bar Extensions In bucket dewar systems the magnet support stand is designed to accommodate either fixed position or retractable current leads. In bottom loading dewars or cryostats with room temperature bores the dewar itself supports the magnet and integrates the current leads into the design. Magnet

OTHER TYPES OF CURRENT LEADS HIGH TEMPERATURE SUPERCONDUCTOR (HTS) LEADS HTS leads are available on a custom basis in both Vapor Cooled or Conduction Cooled versions. The most commonly used conductor material is BiSCCO 2223 doped with a Au/Ag alloy. In cryogenic systems with liquid helium the vapor cooling of the HTS section with helium gas provides low losses, high current density and good system stability. The transition from the warm end of the HTS lead to ambient temperature is made using conventional AMI leads cooled with a forced flow of liquid nitrogen. In systems operating in a vacuum environment the HTS lead is conductively cooled with a mechanical refrigeration system (cryocooler). BREAK-AWAY LEADS The Break-Away option allows the leads to be manually retracted once the magnet is in the persistent mode. This essentially eliminates the heat load from the leads and minimizes the liquid helium boil off. This type of lead is ideal for systems operating in persistent or standby mode for long periods of time. Leads of this type are available up to 1000 Amps. The mechanical and electrical connection between the lower end of the current lead and the superconducting bus bar is made with a low resistance socket-topost connection. The male post is mounted onto an insulated support at the lower end of the cryostat neck region. The female socket is integral to the lead and slides up and down within a guide tube to ensure proper alignment. Multiconductor wands are also available for NMR style systems requiring multiple shim coil operation. FLEXIBLE BREAK-AWAY LEADS Helium gas cooled leads are available in a flexible package that is selfcontained and self-supporting. The leads are straight in the relaxed position and rigid enough to easily connect/disconnect from the cold end current post. This option allows the leads to be bent as they are inserted or retracted where restrictions such as low ceiling height are an issue. This is yet another example of innovative current lead design. SPECIAL APPLICATION LEADS Some applications require special considerations and AMI has the ability to provide solutions for these as well. Examples of such applications include radial array lead clusters, Alternating Current (AC) systems, leads for cryogenic systems using nitrogen gas cooling, and leads operating in a vacuum space with force fed helium gas cooling. Helium reservoirs with level controls are available as an integral part of the current lead construction for vacuum space installations. Coaxial leads can be provided to reduce system penetrations when needed. HTS Lead

OTHER TYPES OF CURRENT LEADS (CONT.) BRASS LEADS Current leads are also available using brass (Cu/Zn) conductor. Because brass has higher thermal and electrical resistivity, these leads will have higher losses during charge mode but lower losses in standby mode compared to copper leads. Brass leads are a good choice for systems operating in standby or persistent mode for long periods of time. HIGH CURRENT LEADS AMI routinely designs and manufactures custom designed current leads over 10,000 amperes. These current leads are designed for the same low helium boil-off and high reliability as our standard leads. Custom configurations are available for both the warm and cold end connections. High Current Leads with custom upper and lower contact points BUS BARS Bus bars carry the current between the magnet and the current leads. Unlike standard NbTi superconducting lead wires, AMI optimized bus bars will carry the rated current even as the level of helium drops across the full height of the bus bar. This prevents magnet quenches from being initiated in the lead wires due to normal fluctuations in liquid helium level and extends your useful helium level operating range. AMI superconducting bus bars are designed to span the distance between the cold end of a current lead and the magnet leads. Resistance heating (I 2 R) is eliminated because the bus bar is superconducting and thus liquid helium boil off is minimized. Most bus bars are a soldered laminate of Nb3Sn/Cu and will remain superconducting as long as the lower end, closest to the magnet, is kept at liquid helium temperature. These bus bars are specifically designed to self supply enough helium boil off so that the operation of an AMI vapor cooled lead is optimized over the full operating range so long as the cold end of the bus bars is always in contact with the liquid helium. The choice of Nb3Sn/Cu also provides good critical current performance even in the presence of high background magnetic field. Current Lead Maximum Liquid Helium Level Bus Bar 80,000 Amp Bus Bar with Vacuum Seal

DESIGN AMI uses proprietary design programs developed in-house for most current lead design projects. We also employ the latest in solid modeling software, including the use of finite element analysis (FEA). Our design engineers work closely with you to fully understand the features, functionality, and stringent requirements your system must meet. From this, prototype units can be designed and quoted, prior to any manufacturing. QUALITY ASSURANCE AMI offers extensive Quality Control and testing. Whether you need a Certificate of Compliance, vacuum leak testing or material certificates, AMI can meet your requirements. Repair and engineering support services are additional benefits. MANUFACTURING AMI has been an industry leader for over 35 years in the design and supply of superconducting magnet systems, current leads, cryogenic liquid level instrumentation, and cryogenic system components. We are qualified to provide leads of either a standard or custom design. Our manufacturing personnel and facility are able to handle any type of production demand, from the small custom lead designs to a high volume order of leads over 10 ka for a large international project. Performing high quality TiG welding on aluminum, stainless steel, copper and various exotic metals is routine. P.O. Box 2509 112 Flint Road Oak Ridge, TN 37831-2509 Tel. (865) 482-1056 Fax (865) 482-5472 E-mail: sales@americanmagnetics.com www.americanmagnetics.com Doc.#: PR1009 Issued: 09/04 Replaces: NEW