Model TWBS.SH Tempered Water Blending System

Similar documents
Model 9201E Tempered Water Blending System

Model Portable Eyewash

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

8320 AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

Installation, Operation and Maintenance Manual

Accu-Tab Systems 2000 P Series by Axiall Corporation

Accu-Tab Systems 1000 Series by Axiall Corporation

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Accu-Tab PowerBase 3012AT by Axiall Corporation

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Installation, Operation, and Maintenance Manual

J Air and Water Kit Instructions Part# 02584

Accu-Tab PowerBase 3070AT by Axiall Corporation

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

8122H AXION Drench / Safety Shower

TITAN FLOW CONTROL, INC.

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

453 Series Steam Heated Vaporizing Regulator

THERM-O-MIX STATION/WWM TEMPERED WATER SUPPLY

D Series Air and Water Kit Part# 02550

Scald Protection Three-Way Thermostatic Mixing Valve

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

HYDROVEX TTT Membrane Flow Regulator

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

Halsey Taylor Owners Manual STOP!

Automatic Non-freeze Valve NF6

Sterile Visual Flow Indicator

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

BS Series Basket Strainer

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

THERM-O-MIX STATION/WWM TEMPERED WATER SUPPLY

INSTRUCTIONS PARTS LIST

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Model: 43T. Bermad Pressure Relief Valve

AUTOMATED INDUSTRIAL MACHINE, INC

Installation and commissioning instructions 255 series and 256 series

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Scald Protection 3-Way Thermostatic Mixing Valve

FLANGED TWO-PIECE BALL VALVES

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Bermad Pressure Reducing. Model: 42T

Installation Instructions JATCO Environmental Protection Tank Model J-7000

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

INSTALLATION / OPERATION / MAINTENANCE INSTRUCTION

ACCU-MIX 1200 / / 26270

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

CF-SERIES HIGH FLOW REGULATORS

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Installation. Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) S19-304GA

TECHNICAL DATA. Page 1 of 12

RAM 4021 Operation Manual

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

OPERATION / 3Z9305G 1:1 RATIO TRITON / Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure

Model 420-HY Pressure Regulating Hydrant Valve

FLANGED TWO-PIECE BALL VALVES

SMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Installation, commissioning and servicing instructions

TITAN FLOW CONTROL, INC.

INSTRUCTIONS FOR MODEL SSC LOW DELIVERY PRESSURE GAS REGULATORS

ROPV R40 E Series User Manual

Medical Gas Control Panel

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings

Installation. S19-300T (top supply) S19-300B (bottom supply)

TECHNICAL DATA. than the water inlet pressure to the concentrate

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Instruction Manual No. 742, 8/98

SERIES BB TRASH BASKETS

92831 TEL: (714) FAX:

D05T Compact Design Pressure Regulating Valves

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Pure Water Power Purification System 4-Stage RODI Operations Manual

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

DS06D,G Dial Set Pressure Regulating Valve

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

Commercial Well Tank Installation Instructions

ELKHART BRASS MANUFACTURING COMPANY

D05 Pressure Regulating Valves

Hygienic Bubble Trap Installation and Operations Manual

Models: C62/63/64-A/D

Transcription:

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 455 Kleppe Lane Sparks, NV 8943-6467 (775) 359-472 Fax (775) 359-7424 HAWS AG Bachweg 3 CH-340 Burgdorf Switzerland Haws Mfg. Pte Lt. 2A Sungei Kadet Drive Singapore 729554 Avlis-Avenido Senador, Testonio Vilela 505 Jardim Aeroporto Itu, S.P. 3304-550 Brasil E-mail: haws@hawsco.com website: www.hawsco.com No. 2080374 (6) Model TWBS.SH Tempered Water Blending System NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY HAWS warrants that all of its products are guaranteed against defective material or poor workmanship for a period of one year from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship, provided that claim is made in writing to company within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale. The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose, which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions HAWS cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries. NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS. SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL, PLEASE CALL: -800-766-562 FOR PARTS CALL: -800-758-9378 (U.S.A. AND CANADA ONLY) MONDAY-THURSDAY: 6:00 A.M. 4:00 P.M. PST FRIDAY: 6:00 A.M :00 P.M. PST 07/08 Model TWBS.SH Page of 6

I. WHAT IS THE HAWS TWBS.SH? The HAWS TWBS.SH is a patented tempered water mixing system (US Patent # 53502) for use with emergency drench shower and eyewash stations where cold and hot water is thermostatically blended to provide a discharge of tempered water at a selected temperature. The TWBS.SH is a thermo-mechanical system with thermally activated and pressure-activated safety features, which do not require electricity for operation. These safety features utilize back-up control valves that ensure a substantial water flow without the risk of scalding, even in the event of main mixing valve failure. Additionally, a temperature limit control valve detects the outflow temperature and helps to reduce the discharge temperature should excessive temperature conditions occur. II. HOW DOES THE TWBS.SH OPERATE? The heart of the TWBS.SH system is the thermostatically controlled mixing valve. It includes an integral strainer and check valves, and has an adjustable temperature control, which is typically set at 80 F. The main mixing valve includes a connection to a cold water supply and a hot water supply, with the ability to provide a discharge outflow of water at a selected/blended temperature level. On the hot water inlet side of this mixing valve we include a high limit temperature control valve, which senses the temperature of the discharge flow. When the discharge flow temperature exceeds our factory pre-set limit of 85 F, this control valve closes and/or modulates, thus reducing the hot water flow being sent to the mixing valve. On the cold-water inlet side, we include a flow control bypass valve, which is responsive to the pressure differential between the cold water supply and the discharge of the tempered water. Should the main mixing valve fail to produce the required mixed flow through the discharge line, the bypass valve senses this and opens up, allowing the incoming cold water to bypass the system and proceed directly to the emergency shower and/or eyewash. These two back-up components permit the temperature level of tempered water to be maintained without undesirable temperature reductions/fluctuations experienced in most failures. They also permit the flow of cold water should the mixing valve fail altogether. III. PERFORMANCE FEATURES OF THE HAWS TWBS.SH SYSTEM Essentially, the HAWS TWBS.SH provides fail-safe protection against scalding or blocked flow. There are three types of failures that can occur with any mixing valve system. They are as follows: ) The mixing valve can stick in an open position and provide an unregulated flow of hot water. 2) The mixing valve can stick in a position, which allows an unregulated flow of cold water. 3) The mixing valve can fail so as to provide an insufficient and/or blocked flow of either hot or cold water. The unique HAWS TWBS.SH answers the above three failure modes in the following manner: Fail-safe Performance Mode # Too much Hot Water The primary safety in the HAWS TWBS.SH is the high limits hot shut-off valve, or the temperature limit control valve, which senses outlet temperatures and modulates the incoming hot water to maintain an outlet temperature below 85 F. This high limit shut-off valve is non-adjustable (tamperproof) and provides a regulated reduction in the temperature level of the discharge flow. This high temperature limit valve provides the first backup for regulating the temperature of the discharge flow in the event of mixing valve malfunction (i.e., too much hot water). Fail-safe Performance Mode # 2 Unregulated Full Flow of Cold Water The HAWS TWBS.SH answers this condition in two ways. When improper mixing valve operation occurs and produces a restricted flow (i.e., a pressure differential between the cold water supply and the discharge tempered water outflow), the flow limit control valve opens to permit the direct flow of cold water past the main mixing valve and into the system. Additionally, the temperature control valve will sense a reduction in the temperature of the discharging tempered water and will open to permit an increased flow of hot water into the system. In this case, the HAWS TWBS.SH can help to produce warm water even when the pressure relief bypass valve is operating. (The high temperature valve opens so as to assist in maintaining a degree of tempered water out). 07/08 Model TWBS.SH Page 2 of 6

Fail-safe Performance Mode # 3 Unregulated Full Flow of Cold Water In the event that water flow through the main mixing valve is obstructed altogether, resulting in a significant reduction in the flow rate out of the discharge line, the flow limit control valve (bypass valve) responds to this pressure differential (set for 25 PSI) and permits the complete bypass and flow of cold water through the system. The HAWS TWBS.SH is designed to accurately, reliably, and safely mix hot and cold water to provide warm water for emergency safety shower and eyewash. It features three back-up conditions that assist in regulating the discharge flow rate and temperature in the event of a mixing valve malfunction. Two of the three include water tempered to some degree and none require the need for any electrical supply. IV. CAPACITY HAWS TWBS.SH produces up to 40 GPM at a pressure drop of 36 PSI and requires 26-PSI dynamic pressure differential to produce 30 GPM. It requires 5 PSI of dynamic pressure differential to produce 20 GPM. The eyewash temperature at 6 GPM remains steady 80º F while there may be slight fluctuation upon demands over 30 GPM (shower application). 30 Pressure Drop Across TWBS.SH (Δpsi) 25 20 5 0 5 0 0 5 0 5 20 25 30 35 Water Flow Rate (gpm) TWBS.SH Flow rate in various pressure differentials 07/08 Model TWBS.SH Page 3 of 6

V. INSTALLATION A). APPLICATION The standard TWBS.SH is sized to blend enough water for one shower, five eyewash units, or ten face wash units at a time. If there is a good chance that two or three showers might be used at the same time, our High Flow TWBS should be specified. This Tempered Water Blending System should be installed in close proximity to shower/eyewash. It should be clearly identified, with easy access and free from obstructions. Supply lines must be heat traced if subject to freezing temperatures. If the piping network is through a cold area, piping should be heat-traced with self-regulating heat tape, or recirculated through the TWBS.SH. Any heat-traced piping should be protected with scald protection bleed valves. Additionally, should the TWBS.SH be mounted at a distance greater than 50 feet from the shower and/or eyewash, these runs should be evaluated by a plumbing engineer. Complicated chains of showers, long piping runs and recirculating loops should all be evaluated by a qualified engineer. B). C). RECOMMENDED TOOLS Pipe joint sealant, adjustable pipe wrenches, (2) rust resistant wall anchors (3/8" diameter). WATER SUPPLY The minimum recommended supply lines are -/4" IPS COLD and -/4" IPS HOT. Cold supply temperatures should range from 35 F to 75 F. Hot supply temperatures should range from 0 F to 80 F. For best operation, hot water should be at least 20 F above desired set point. A minimum of 40 GPM at 35-PSI dynamic pressure must be provided. Inlet and outlet connections are -/4" IPS dielectric unions. We recommend a manual bypass loop with appropriate tamper resistant shut-off valves to allow for tempered water system maintenance or service without interrupting emergency shower/eyewash operation. IMPORTANT: Install a check valve or thermal trap at cold water inlet of hot water tank: Hot water must never enter cold inlet of tempering system. D). PROCEDURE USE PIPE SEALANT ON ALL WATER CONNECTIONS. Step : Step 2: Step 3: Mount unit on wall. Bolt dia. 3/8" fasteners through internal strut support frame. Flush supply piping prior to connecting to inlet unions. Connect outlet union to piping leading to shower/eyewash. Check for leaks. TEST FUNCTION OF UNIT A). Turn on one eyewash. Carefully monitor initial few minutes of flow with hand in eyewash flow. Check to insure initial flow does not contain brief shots of hot water. If any problems, see troubleshooting. B). Adjust mixing valve cooler while watching outlet temperature gage to insure proper function of mixing valve. Gage should register temperature drop as valve is adjusted to lower temperature. C). Adjust mixing valve to maximum hot to test function of anti-scald protection valve and cold by pass valve. Maximum temperature should be limited to 85 F + 5 F. Adjust mixing valve cooler until outlet temperature reaches 80 F. IMPORTANT: REPEAT TEST PROCEDURE WEEKLY! 07/08 Model TWBS.SH Page 4 of 6

VI. TROUBLE-SHOOTING TROUBLESHOOTING PROBLEM REPAIR CHECKLIST. Outlet temperature too hot.. a. Insure cold and hot supplies are plumbed to proper inlets. Check cold water supply temperature. If cold water supply is too hot due to solar heating, install anti-scald bleed valves in hot sections of cold water supply line. b. Adjust main mixing valve cooler. If supply water temperatures are within correct ranges and main mixing valve will not adjust to provide desired outlet temperature, replace mixing valve. If outlet temperature is above 90 F, replace antiscald hot water shut-off valve. 2. Outlet temperature starts too hot then cools down. 2. a. Check inlet cold line. If hot water is siphoning into cold line, install check valve or thermal trap in line. b. If cold supply has hot spots due to solar or other heating, install anti-scald bleed valves in hot sections of line. 3. Outlet temperature too cold. 3. a. Insure proper supply of hot water b. Adjust main mixing valve warmer c. Clean inlet strainers in mixing valve assembly by removing bonnet with 2-/4 wrench at the bottom of check stop. d. Under high volume demand (26 gpm or more) the blending system outlet temperature will slightly drop. e. If mixing valve will not adjust to proper temperature and both hot and cold supply temperatures are within specified ranges, replace mixing valve. f. Check stop(s) may be closed. Open check stop by turning stem counter clockwise with a slotted screwdriver. VII. REPLACEMENT PARTS Description Temperature Gage, /2 Mixing Valve Bypass Valve, Hot Shut-off Valve, Quantity 2006 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 07/08 Model TWBS.SH Page 5 of 6