STRAIGHT CONNECTOR The Push-fit straight connectors make splicing microduct fast and easy. Simply push the microduct into the center of the connector. No tools are required. The connector can be connected and disconnected 10 times and still maintain the high performance requirement for air-blown installation systems. Microduct connector operates at 15 bar with a maximum permissible leakage rate of 1cc/min. This is equivalent to 1 bubble every 3 seconds. Higher pressures have been used in the field with no increase in leakage rate. Quick Burst rating is 25 bar. For Tubing Type: PE, PU, Nylon, Polyurethane Burst Pressure: > 25bar Push-fit test: Pass Hydraulic pressure test: Pass(Resisting at 13 bar for 2 minutes)
END CAP To Keep Microduct networks free of debris, seal the system with Push-Fit Endcaps. With the same functionality as the Push-Fit Connectors, installation simply involves pushing the Microduct into the Endcap. It can be attached and removed 10 times while still maintaining the same high performance characteristics. Push-Fit Microduct endcap operates at 15 bar with a maximum permissible leakage rate of 1cc/min. This is equivalent to 1 bubble every 3 seconds. Higher pressures have been used in the field with no increase in leakage rate. quick Burst rating is 25 bar. Burst Pressure: BT MA 321 High Pressure Performance hydraulic pressure test: Pass(Resisting at 13.5kgf/ cm2 for 2 minutes.) Burst Pressure: > 25bar Water Immersion test: Pass (Water proof)
DBL CONNECTOR, END CAP The direct burial endcap is used in access network where the direct buried thick walled microduct is sealed to keep microduct networks free of debris and moisture. With the same functionality as the connectors, installation simply involves pushing the microduct into the endcap. Material: HDPE Burst Pressure: > 25.5kgf/ cm2 Expected Life time: Minimum 20 years
REDUCING CONNECTOR The Push-fit reducing connector make splicing microduct fast and easy. Simply push the microducts into the center of the connector. No tools are required. The reducers can be connected and disconnected 10 times and still maintain the high performance requirements for air blown installation systems. Microduct reducing connector operates at 15 BAR (218 psi) with a maximum permissible leakage rate of 1cc/min. This is equivalent to 1 bubble every 3 seconds. Higher pressures have been used in the field with no increase in leakage rate. Quick Burst rating is 25 BARS (363 psi). Burst Pressure: > 25.5kgf/ cm2 Expected Life time: Minimum 20 years hydraulic pressure test: Resisting at 13.5kgf/ cm2 for 2 minutes 5-3.5 7-3.5 8 6 10 8 12 10 14 12 16-12
GAS-BLOCK CONNECTOR Gas block microduct connectors normally used between indoor and outdoor environments to prevent air fow that may result in condensed water getting into in ducts. After cable installation, the connector can be gas sealed by Pushing the connector ends together. This version is intended for 7mm to 14mm thick walled ducts. Technical Specifications Material: Body PC, impact resistant Collect POM, Stainless steel teeth O-rings Nitrile rubber, Cable size(mm) 7mm ( 1-4.6mm cable) 10mm (5-8mm cable) 12mm (3-6mm cable) 12mm (5-8mm cable) 12mm (7-10mm cable 14mm ( 3-6mm cable) 14mm (7-10mm cable) 14 (9-12mm cable) 14mm GasBlock Connector Blowing Pressure: Between temperatures of -10 and +60, all connectors size can be used for blowing operations at pressures up to 16bar. Burst Pressure: > 26bar Gas Tightness: Leakage at 16 bar gas pressure: 1ml/minute approx Leakage at 0.7bar gas pressure: 0.1ml/minute approx Water ingress: The connectors shall seal against a 6m head of water. Insertion force: 50N max (5kg) Retention force: 55N min (5mm m/d) 135N min (12mm m/d) 155N min (14mm m/d) (collect not held in)