CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

Similar documents
INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Sports Wrist Digital Blood Pressure Monitor Item #

Semi-Automatic Blood Pressure Monitor with Memory

Auto Arm Blood Pressure Monitor

Digital Blood Pressure Monitor. Model UA-705. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni 1WMPD B

Digital Blood Pressure Monitor. Model UA-787

VER: A00. Model No:BA2010

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

LD22. Digital Blood Pressure Monitor Instruction Manual

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

User Manual. Hopkins IMPACT Digital Wrist BP RELATED ITEMS. Item #526014

LD6. Digital Blood Pressure Monitor Instruction Manual

Contents. Safety Notice. Wrist Type

Contents. Helpline No. UK/Northern Ireland , Rep. Ireland Web Support Model Number:

Fully Fuzzy Auto Digital Wrist Blood Pressure Monitor. tensio control. INSTRUCTION MANUAL Model GP-6220

MEDICARE 60. Semi-automatic upper arm blood pressure monitor. Instruction manual

6833_INSTRUCTIONS MANUAL DIGITAL WIRST BLOOD PRESSURE

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

English Español Português Italiano Deutch Français INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR MODEL CH-656C. - Eng 1 -

LD7. Digital Blood Pressure Monitor Instruction Manual. Ciśnieniomierz elektroniczny automatyczny LD Instrukcja Obsługi ENG POL

Instruction Manual. Auto Inflate Blood Pressure Monitor

Oregon Scientific Wrist Blood Pressure Monitor (BPW211)

Blood Pressure Monitor

Blood Pressure Monitor

Wrist Type Blood Pressure Monitor

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

Blood Pressure Monitor

REF CH-302B IDENTIFICATION OF PARTS

premium wrist blood pressure monitor

Talking Wrist Style Blood Pressure Monitor Model INS-LAB-RevB08

Fully Automatic Blood Pressure Monitor

Blood Pressure Monitor

Digital Blood Pressure Monitor for the Upper Arm INSTRUCTION MANUAL

Talking Wrist TypeBlood Pressure Monitor. Talking Wrist Type Blood Pressure Monitor Model: BPW810. User Manual

TD-3140 Blood Pressure Monitor. Owner s Manual

MODEL CH-432B INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR. - Eng 1 - English Español Português Deutch. Italiano Français CH-432B

TD-3140 Blood Pressure Monitor. Owner s Manual

Blood Pressure Monitor

Blood Pressure Monitor

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing

Instruction Manual. Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

PHY100 s Lab: The Relationship Between Liquid Pressure and Depth as it applies to Blood Pressure. Course & Sec:

REF CH-602B IDENTIFICATION OF PARTS

5 series Blood Pressure Monitor

Oregon Scientific Wrist Blood Pressure Monitor (BPW120)

Owner s Manual. EZ Health TM Platinum Talking Automatic Wrist Blood Pressure Monitor ABP-A3

Wrist Blood Pressure Monitor Model R2

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing

Operating Instructions Instrucciones de funcionamiento

Instructions for use. 3year. Wrist MOBIL BASIS. The monitor for first users To be used on the wrist. Also suitable for: WARRANTY. Clinically validated

3.1.3 Weight. Frequency. Weight is obtained at the baseline examination and annually. Equipment

Model M3 Intellisense

Check following components!

Digital Blood Pressure Monitor Model UA-621 Instruction Manual

Model UA-705. Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Blood Pressure Monitor

Instruction Manual. Wrist Blood Pressure Monitor with Advanced Positioning Sensor (APS ) Model HEM-650 ESPAÑOL ENGLISH

GoWISE USA R Blood Pressure Monitor Wrist Type. Instruction Manual

HOME BLOOD PRESSURE KIT INSTRUCTIONS TRILINGUAL INSTRUCTION GUIDE MODEL UA-100

Instruction Manual. Automatic Blood Pressure Monitor for Arm - Voice Prompt Function Announces Measured Values HB-ZA310V

Content

Model MIT Elite Plus

Instruction Manual. S&S Tradings

SBC 21. Electromagnetic Compatibility Information

STANDARD OPERATING PROCEDURE ARTSANA MERCURY SPHYGMOMANOMETER

SpotArm Type Blood Pressure Monitor. Model i-q142

Instructions. Upper Arm Blood Pressure. Model EW3153

Module No GETTING ACQUAINTED GENERAL GUIDE TIMEKEEPING

User Manual DMD1001. Arm Type. Digital Blood Pressure Monitor. version:1.0

705CP-II. Automatic Blood Pressure Monitor & Printer. Mode d emploi page 67 Istruzioni per l uso pagina 89

Circulation and Respiration: Vital Signs Student Version

User Manual DMD1001. Arm Type. Digital Blood Pressure Monitor. version:1.0

ProSeries 2. Blood Pressure Monitor. Quick Start Guide. A complete user guide is available at vitasigns.com

VIDEO TUTORIAL: greatergoods.com/0605

INSTRUCTIONS. Manual Home Blood Pressure Monitor MODEL Stethoscope Chestpiece. Cuff. Bulb

Infrared Thermometer Instruction manual

INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR

REF CH-308B INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR IDENTICATION OF PARTS Eng 1 - Exhaust button Air connector Pumping bulb tube

Fully Automatic ihealth Track Connected Arm Blood Pressure Monitor USER MANUAL

User Manual DMD1001 1

Intermittent Pneumatic Compression System

WARNING: EXPLOSION HAZARD

Blood Pressure Monitor Instruction Manual

UA-851THW/UA-851TMW/UA-851THX Wireless Automatic Blood Pressure Monitor Users Manual

MODEL CH-485E INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR. English Español Português Deutsch. English Español Português Deutch Français

Model UA Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

VGP-4300-G. Travel Pulse. Blood Pressure Monitor for Travel

Automatic Blood Pressure Monitor Model M6 Instruction Manual

TECHNICAL CHARACTERISTIC CT 071

Owner s Manual & Safety Instructions

The RICH LIFE Project: Blood Pressure Training Certification Checklists

Aneroid Sphygmomanometer. Use, Care, & Maintenance

Check following components! Vérifier les composants suivants! Digital Automatic Blood Pressure Monitor Model M3 Instruction Manual

Owner's Manual. Wrist-type Fully Automatic Blood Pressure Monitor. Contents. Safety Notice. Model BP2116. Document No. Version: REV

AIR PRESSURE MASSAGER #Unwind

Instructions for use. Upper arm. The No. 1 blood pressure monitor in German pharmacies* BASIS CONTROL. Also suitable for: ANS DE GARANTIE **

INSTRUCTION MANUAL DIGITAL BLOOD PRESSURE MONITOR

Transcription:

IFU SBPMON107

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE BATTERY INSTALLATION CORRECT POSITION FOR MEASUREMENT POSITIONING THE CUFF TAKING BLOOD PRESSURE READINGS AUTOMATIC INFLATION RELEASING PRESSURE FROM THE CUFF MEMORY FUNCTION CLEARING THE MEMORY OF THE DEVICE ERROR DISPLAYS 2 2 2 3-4 5 5 6-7 7-8 8 8 9 9 10 Model Method of the measurement Indicator Measuring Range Measuring Accuracy Inflation Deflation Power Supply Maximum Power Consumption Memory Operation Conditions: Temperature Relative Humidity Transportation Conditions: Temperature Relative Humidity Cuff Dimensions Dimensions and weight (without cuff or case): Size Weight SLD3 107 Oscillometric Liquid-crystal 40 to 260 mmhg (pressure) 40 to 160 pulse beats/minute (pulse rate) cuff pressure ± 3mmHg pulse rate ± 5% of reading automatic (the air pump) automatic (the electronic valve) 4 AA 1.5V batteries 3.6W 90 times (+ average) +10ºC to +40ºC 85% and below -20ºC to +50ºC 85% and below 22-32cm (larger available to purchase) 135(L) x 95(W) x 50(H) 300g including batteries CARE, STORAGE, REPAIR AND RECYCLING TROUBLESHOOTING WARRANTY SPECIFICATIONS 11 12 13 14 Contents Life expectancy in normal home use: Device Cuff Year of manufacture Device, cuff, 4 x AA batteries, instruction manual, warranty card. 5 years 2 years On device label 1 14

WARRANTY 1). The warranty period of this device is 12 months from the date of sale and does not include batteries or devices that have been misused or tampered with. 2). Please fill in the warranty page and return it to the manufacturer. 3). The address of the manufacturer is in the warranty certificate. GENERAL INFORMATION This instruction manual is intended to give general instructions and advice on the operation of the automatic digital blood pressure monitor (device) model SLD3 107. The device should be used in accordance with the procedures contained in this manual and should not be used for purposes other than those described. It is important to read and understand the entire manual, in particular the section TIPS ON TAKING YOUR BLOOD PRESSURE, before use. RECOMMENDED USE This device is intended for the measurement of Systolic and Diastolic arterial blood pressure and determining the pulse rate in adult patients, i.e. age 15 and above. The cuff will accommodate an upper arm circumference range of 22 to 32 centimetres. Blood Pressure is measured over a range of 40 to 260 mm of mercury (Hg) and heart rate over a range of 40 to 160 beats/minute. OPERATING PRINCIPLE The cuff is wrapped around the arm and inflated with the help of an air pump in the device. The device measures the fluctuations in the pressure of the cuff produced by extension and contraction of the artery in the arm in response to each heartbeat. These are converted into millimetres of mercury (Hg), and are displayed as a digital value. This device may not meet the specified accuracy if it is used or stored in temperature or humidity conditions outside the parameters stated in the SPECIFICATIONS section of this manual. There can be possible errors in the measurement in patients with expressed arrhythmia. Consult your physician if you wish to take a child s blood pressure. ATTENTION! Do not use cuffs other than the original cuff supplied in this kit. 13 2

3 TIPS ON TAKING YOUR BLOOD PRESSURE 1). Blood pressure can be subject to wide fluctuations in a short space of time as the level of blood pressure depends on many factors. Usually the level of blood pressure is lower in summer and higher in winter; it can change with atmospheric pressure and depends on many factors, e.g. physical work, emotional state, stress, meals, dietary pattern, etc. Different medicines, alcohol and smoking can exert a large influence on the level of blood pressure. When blood pressure is measured in a hospital it can be higher than when measured at home, as people may be tense while in the hospital and more relaxed at home. Since blood pressure increases in low temperature, determine blood pressure at room temperature (approximately 20ºC). If the device has been stored below room temperature, it should be allowed to warm to room temperature for at least 1 hour; otherwise the measurement could be affected. Blood pressure can change easily and readings during the day can differ by 30-50 mmhg of systolic (higher) pressure and by up to 10mmHg of diastolic (lower) pressure. The dependency of blood pressure on different factors is individual to every person. Therefore, it is recommended that the results of the blood pressure tests are recorded. 2). When monitoring blood pressure is necessary in cases of cardiovascular and other diseases, it is advised that blood pressure readings are taken at times recommended by your healthcare professional. The diagnosis and treatment of hypertension can only be made by a qualified healthcare professional. SYMPTOM No display when the O/I button is pressed. Inflation stops and is again renewed. Blood pressure is different each time. The reading is extremely low (or high). Pulse rate is too low (or high). It is impossible to obtain higher readings. The power supply is automatically turned off. TROUBLESHOOTING CHECK POINT The batteries have run down. Polarity (+/-) of batteries incorrect. The battery contacts require cleaning. An automatic action to ensure the correct reading. Did you talk or move your arm (or hand) during measurement? Is the cuff at the same level as the heart? Is the cuff wrapped too tight or too loose? Did you tense your arm during the measurement? Did you talk or move your arm during the measurement? Did you talk or move your arm during the measurement? Did you take the reading immediately after exercise? Usage of faulty batteries. Check that the device turns itself on and off again. REMEDY Replace all the batteries with new ones. Install the batteries correctly. Clean the contacts with a dry cloth. See AUTOMATIC INFLATION. Relax and repeat the measurement. Make sure that your arm is correctly positioned; see CORRECT POSITION FOR MEASUREMENT. See POSITIONING THE CUFF. Relax before measuring. Remain still and silent during the measurement. Remain still and silent during the measurement. Measure again after resting for more than 5 minutes. Use only alkaline batteries of high quality. This does not indicate a problem. The device automatically turns off 3 minutes after the last measurement or in 5 seconds after memory display. If you cannot get correct measurements with methods above, stop using the device and contact the Customer Care Line on 0800 0430318. Do not try to repair the device. 12

CARE, STORAGE, REPAIR AND RECYCLING 1). It is essential to protect this device against damp, direct sunlight, shock, and vibrations. This device is not waterproof. 2). Do not keep and do not use the device near heaters or naked flames. 3). Remove the batteries if the device is to be stored for an extended period of time. Leakage of batteries can cause damage to the device. Keep the batteries out of reach of children! 4). Keep the device clean and away from dust. Use only a soft, dry cloth to clean the device. 5). Avoid any contact with water, solvent, alcohol and petrol. 6). Keep the cuff away from sharp objects and do not try to stretch or twist the cuff. 7). Do not drop or knock the device. 8). Repairs can only be made by the manufacturer. 9). The device should be checked and maintained after 2 years of use. 10.) Neither the device nor the batteries are household waste; follow your local recycling rules and dispose of them at appropriate collection sites. 11). The Cuff should only be cleaned when necessary. The fabric should be cleaned with cotton wool and a 3% solution of hydrogen peroxide. After long use, partial discoloration of the fabrics covering the cuff may occur. The cuff must not be laundered or ironed. 3). The correct measurement of arterial pressure can be difficult in patients with deep arteriosclerosis, a weak pulse, and in patients with irregular heart beats. In these situations a qualified healthcare professional should interpret your blood pressure readings. 4). In order to get accurate blood pressure readings patients should be in a relaxed and quiet state. The measurement of blood pressure should be carried out in a quiet environment at room temperature. Eating for 1 hour or drinking alcohol for 1.5-2 hours before the test, smoking, and other activities that affect blood pressure should be avoided before taking readings. 5). To ensure accurate readings the cuff should be a good fit on the upper arm. When fitted it should be possible to fit two fingers comfortably between the arm and the cuff. 6). For accurate blood pressure readings an interval of at least 3 minutes between readings should be allowed to restore the blood circulation. Patients suffering from pronounced atherosclerosis, and those who have suffered from diabetes over an extended period of time, require a longer time interval between measurements (10-15 minutes) because the elasticity of the vessels can be decreased significantly by these diseases. For a more exact determination of blood pressure, take a series of 3 readings and calculate the average. 11 4

BATTERY INSTALLATION 1). Open the battery cover and install four long life AA type batteries into the compartment as indicated. Make sure that the batteries polarities (+/-) are positioned correctly. Never use force to remove the battery cover. 2). Close the battery compartment cover. Replace the batteries when battery replacement indication appears on the display or if the display is blank when the O/I button is pressed. The batteries delivered in the device are intended to check the device after sale; the period of service of these batteries can on occasion be less than other high power batteries. Replace all batteries simultaneously. Do not recharge batteries. If the device is not used for a long period, remove the batteries. Do not leave run down batteries in the device. Indication ERROR DISPLAYS Possible Reason The cuff is not correctly applied or the tube plug is not inserted tightly. The measurement could not be made because of moving an arm or hand, or talking during measurement. The cuff was not inflated to the necessary pressure. Correction Methods Make sure that the cuff is put on correctly and the tube plug is inserted tightly and repeat the measurement. Repeat the measurement by following the instructions. Repeat the measurement inflating the cuff to 30-40 mm Hg above expected systolic pressure. CORRECT POSITION FOR MEASUREMENT 1). Sit at a table and let it support your arm as you take the arterial blood pressure measurement. Make sure that the measurement location on the upper arm is at approximately the same height as the heart, and that the forearm is extended naturally on the table and does not move. 2). You may lie on your back and take the measurement. Look at the ceiling, stay calm, and do not move your neck or body during the measurement. Make sure the measurement location on the upper arm is at approximately the same height as the heart. Arrhythmia (irregular heart beat). The batteries are weak. Consult your healthcare professional. Replace all 4 batteries with new ones. 5 10

MEMORY FUNCTION 1). The result of each measurement (blood pressure and pulse rate) is automatically stored in the memory of the device. The reading will not be saved when it resulted in an error. 2). Up to 90 readings and the average value of the last 3 readings can be stored in the memory of the device. When the number of readings exceeds 90 the oldest readings will be replaced by the newer readings 3). To examine the data stored in the memory press the MEM button, either after use or when the device is in standby. When the MEM button is pressed the display will show the average of the last 3 readings ( Fig 1) and then if MEM is pressed again it will show << 1 >> and then the last reading (Fig 2), each further pressing of MEM will show the next oldest reading, << 2 >>,<<3>> etc. Fig. 1 Fig. 2 POSITIONING THE CUFF 1). Put the edge of the cuff into the metallic ring as shown in Fig. 1. 2). Put the cuff on the arm and position the tube on the inner arm (Fig. 2). If measurement on the left arm is difficult the right arm can be used, but readings may differ by about 5-10mmHg. 3). Wrap cuff around the upper arm with the lower edge of the cuff approximately 2-3 centimetres above the elbow. Fig. 3 - The mark with inscription << ARTERY>> must be over the artery of the arm. 4). Press the surface of the cuff to make sure that it is attached securely (Fig. 4). When wrapping the cuff, wrap it loosely enough around the arm so that two fingers can be placed between the cuff and the arm. If the cuff is wrapped more tightly or loosely than this, inaccurate blood pressure readings may result. Fig. 1 Fig. 2 Fig. 3 9 CLEARING THE MEMORY OF THE DEVICE To clear all stored results from the memory of the device press button MEM and hold it more than 3 seconds. The symbol << Clr >> will be displayed and whole memory of the device will be cleared (Fig.. 3) Fig. 3 5). On the fastened cuff the mark << INDEX >> must point to the area << NORMAL (22-32cm) >> (Fig. 5). This means the cuff is selected correctly and corresponds to the size of the upper arm range. If the mark Fig. 4 points to the area marked << >> or to the left, that means the cuff is too small and the reading will be too high. If the mark points to the area << >> or to the right, that means the cuff is too large and reading will be too low. Fig. 5 6

6). If the patients arm tapers significantly from shoulder to elbow, put the cuff on at an angle as shown in Fig. 6. 7). If you are wearing a shirt that might restrict circulation in your upper arm, the blood flow will be restricted, preventing accurate measurement (Fig. 7). TAKING BLOOD PRESSURE READINGS 1). Insert the tube plug into the air connector. Fig. 6 Fig. 7 Before the measurement, take 3-5 deep breaths (inhalation-exhalation) and relax. Do not move, talk or strain your arm or hand while the reading is being taken. 5). The bleep will sound at the end of the measurement, the device will release all the air from the cuff and the readings will appear on display (Fig. 4). 6). Press the O/I button of the device to switch off. For further readings repeat all actions given in this section. To obtain accurate results it is necessary to pause between readings to restore the circulation of blood. Do not take further readings in less than 3 minutes. The result of each reading is automatically stored in the memory of the device (up to 90 readings). Data will be stored in the memory even if the batteries are removed. The stored data can be removed from the memory of the device as described in the MEMORY FUNCTION section. If the power supply is not switched off and the device is not used for 3 minutes it will be switched off automatically. Fig. 4 2). Press and hold the O/I button until the device starts to operate. 3). All symbols will appear on the display for a short time (Fig. 1) then two short bleeps will sound and the device will begin automatically to inflate the air into the cuff. 4). After reaching 190mmHg (Fig. 2) the pressure in the cuff will begin to fall gradually. The data on the display will decrease. The pulse rate is indicated by the blinking symbol << >> (Fig. 3). Since the blood pressure and the pulse are measured during the deflation of air from the cuff, try to remain still and do not move your arm or hand, or tense the muscles in them, during the measurement. Fig. 1 Fig. 2 Fig. 3 AUTOMATIC INFLATION If the initial inflation of the cuff to 190mmHg is not sufficiently high for a particular patient, or if any movement of the arm or hand occurred during the reading, the device will stop the measurement. It will then re-inflate the cuff to a higher level. There are 4 fixed levels in the cuff: 190, 230, 270 and 300 mmhg. The automatic inflation of the cuff is repeated until a suitable level for the patient is reached. This is not a fault. RELEASING PRESSURE FROM THE CUFF If during the inflation of the cuff or during the measurement (slow increasing of the pressure) you need to release the pressure in the cuff quickly, press the O/I button. The device will quickly release all the air from the cuff and it will be switched off. 7 8