PORTABLE MEDICAL AIR SYSTEM

Similar documents
OxyTOTE PORTABLE OXYGEN SYSTEM

Medical Products. Quality Without Compromise. Global Gas Management Technology. Enterprises Innovator Medica Westwinds

MEDICAL Products. Medical Products Catalog

TITAN Oxygen Regulators

NITROGEN PURGING SYSTEMS FOR THE HVAC INDUSTRY VISION INNOVATION SOLUTION

7625 West New York Street Indianapolis IN Phone: Fax: Order Desk:

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Valve with Integrated Pressure Regulator for medical OXYgen

Flowmeters & Accessories Guide

URGENT MEDICAL DEVICE RECALL NOTICE

Rev. B. Operating Instructions

First and Only Disposable Infant T-Piece Resuscitator. Because they are not miniature adults...

Welcome to the Specialized Medical Services Respiratory training webinar series!

REGULATORS FLOWMETERS HUMIDIFIERS. Professional GAUGES ASSESSORIES. Medical Apparatus. and Assessories ISO 13485/ISO 9001 CERTIFICATION

NEW Edge Series Products: OUTFITS and REGULATORS

SUCTION REGULATORS, FLOWMETERS & ACCESSORIES

MEDICAL CYLINDER VALVES

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

Description Advanced Features Typical Applications

Nonrefillable Cylinders

Ever. EverFlo. Home oxygen system. Oxygen simplified

Oxygen Dialflow Meter. Instructions for Use

Micro Dial-Flowmeter. Instructions for Use

PRECISION GAS MIXTURES

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Operating Manual. Models PAK-4 & PAK-4R Manual No. PAK002 (Rev 6 February 1999)

Emergency Transport and Ventilation

Quick Specs. INERGEN Clean Agent Fire Suppression System

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)

Precision Calibration Gas

PRODUCT INFORMATION AND INSTRUCTIONS OM-810

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

OXYGEN THERAPY FLOWMETERS, REUSABLE AND SINGLE-PATIENT HUMIDIFIERS, PRESSURE REGULATORS, FLOW SELECTORS

300 Held Drive Northampton Pa

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

DESCRIPTION AND OPERATION OXYGEN SYSTEM OXYGEN SYSTEM

Before using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet.

Ozone Stuff Album A Work in Progress. 03/09/2017 by J Tim Rainey DDS

Oxygen Generating Systems Ozone Medical Welding Glassblowing Aquaculture Pulp & Paper Wastewater

Operating Manual CBA Series Cascade Breathing Air Assemblies

SUCTION Attachments 7 Suction Regulators 10 Accessory Products 11. EMERGENCY RESUSCITATION Oxy-Viva 3 12 R-Viva 13 Demand Valves & Masks 15

Oxygen Dialflow Meter. Instructions for Use

REGULATORS FOR SPECIFIC APPLICATIONS

Operating Manual. Model MP-4R and MP-4RSS MULTI-PAK TM RESCUE AIR CARTS Manual No. PAK013 (Rev 1 January 2001)

O-Two Self-Study Guide. Equinox Relieve

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

VETROSON. OXY-GEN SYSTEMS (Oxygen Generating Systems) Question & Answer Brochure

- GAS REGULATOR - COMPACT STYLE

AND EQUIPMENT FOR ENVIRONMENTAL APPLICATIONS (800) B Polk Street Houston, TX

Precision matters. HiQ equipment for specialty gases.

Presence PR, PRC & PRE

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

Operating Manual. Models MP-23ENBC, MP-23LPANB, MP-23EHNBC, MP-2300HNB

Backpack Cutting System. processes, from cutting to piercing. Patented style oxy-flame tubes handle the scope of almost any assignment.

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

American Medical Gas Outlets

I. Subject: Compressed gas cylinders, regulators, and portable liquid systems.

Home Oxygen Products. > Innovation > Quality > Safety

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Hospital and Transport for Controlled Breathing

VERTICAL BLADDER TANK

NEW EDGE SERIES REGULATORS & OUTFITS

BREATHING AIR SYSTEMS HIGH-PERFORMANCE PRODUCTS FROM SCOTT

HORIZONTAL BLADDER TANK

First Stage Regulators

INFUSION SYSTEM (110V) (220V) USER S MANUAL

PRESSURE REDUCTION FLOWMETERING, QUICK COUPLING PROBES AND ACCESSORIES

DS05C,D,G Dial Set Pressure Regulating Valves

Refrigerant Gases Valves

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

North American Orifice Metering System

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

CRYOGENIC SERIES Regulators, Pressure Gauges, Shut-off Valves, Relief Valves Technology for a Better Future

Tools & Installation. Tools & Installation Index

TABLE OF CONTENTS. 14 Operating Instructions Load vs. Contact

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Hotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:

PRESSURE CONTROL REGULATORS

Oxy-Fuel Safety Training. Participant s Guide

D Quality and Precision you can Trust in Oxygen Administration CONVENTIONAL FLOWMETER DIGITAL FLOWMETER COMPACT FLOWMETER

Cover headline. Cover subheadline. Check Valves

Livewell/Baitwell Pumps. Livewell/Aerator

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data

Medical Gas Control Panel

Air Amplifiers & SYSTEMS

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

Petro-Chemical & Analyzer Sampling Systems

BREATHING AIR SYSTEMS HIGH-PERFORMANCE PRODUCTS FROM SCOTT

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

The right atmosphere for health. A system for medical gas supply

PXRF- Tracer Helium Flow Control System

Equinox II NITROUS OXIDE / OXYGEN ADMINISTRATION EQUIPMENT 01EQ7000E

Petro-Chemical & Analyzer Sampling Systems

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL

ELKHART BRASS MANUFACTURING COMPANY

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

Transcription:

ALL-IN-ONE CONVENIENCE PORTABLE MEDICAL AIR SYSTEM 2007 Western Medica AIRTOTE Western s new AirTOTE portable medical air system brings a new level of simplicity and cost Portable Medical Air System with SureClick effectiveness to distributing medical air. Its all-inone design incorporates a click-style regulator with a cylinder valve. The AirTOTE Feature system is based on Western s OxyTOTE design, proven in years of use in thousands of locations. The frustration and time of matching regulators and cylinders is eliminated, while your patients get their precise flow. The AirTOTE system also includes Western s unique SureClick feature. SureClick reduces the risk of dialing the flow selector between click settings, making it easier for clinicians to dial in and secure oxygen flow. 800.783.7890

Durable cover protects regulator & valve assembly. Built in handle for portability. All-In-One brass regulator assembly incorporates post valve and regulator into one single unit. Units are quickly refilled through a CGA-346 fill port on reverse side. AirTOTE system with DISS 1160 On/Off flow control knob with adjustable flow rates of 1-25 liters per minute. Medical outlet barb for attaching cannula. Barb outlet is recessed for protection against damage. Easy-to-read 1-1/2 cylinder contents gauge. FEATURES DISS 1160 auxiliary port (demand valve). Outlet pressure 50 psi Hose barb for use in controlled flow applications (cannot be used simultaneously with DISS) Regulator and cylinder valve combined into one unit User can initiate flow in one easy step Compact design with all brass body Maximum rated inlet pressure 3000 psi Transfill through CGA-346 port Filtration throughout for maximum safety Integral reseating relief valve protects against over-pressurization Protective shroud ensures safety and lasting performance 1-1/2'' diameter gauge On/Off valve maximizes regulator life by minimizing its exposure to cylinder pressure. AirTOTE REGULATOR SPECIFICATIONS PART# MTR-300 (AirTOTE head only for aluminum cylinder) MTS-303 (AirTOTE on E aluminum cylinder) Size 7-3/4'' x 4-1/2'' Weight 2 lbs. 10 oz Flow (LPM) 1, 2, 3, 4, 6, 8, 10, 12, 15, 20, 25 800.783.7890 Press 3 for Medical Customer Service 2007 Western Medica AirTOTE, OxyTOTE and SureClick are trademarks of Western Medica B20522 07/01 5M 1/07

OxyTOTE NG The Next Generation in Portable Oxygen Systems When Seconds Matter We Deliver!

OxyTOTE NG OxyTOTE NG System Advantages Product Design Western designed the Next Generation Integrated Valve Regulator, the OxyTOTE NG, to meet the demands of both EMS emergency services as well as in-hospital patient transport. It is small, lightweight, ergonomically designed, and is easy to handle and transport. Every aspect of its intended use was carefully considered during the design process, including its length, which allows the OxyTOTE NG to fit into most EMS duffle bags as well as horizontally on most hospital beds and gurneys. Ease of Use OxyTOTE NG is ready to act when you are. No separate regulator to locate and install on a cylinder, saving valuable time when you need it the most. Simply turn the unit on and set the desired oxygen flow. OxyTOTE NG knobs are larger and light in color, making them easy to see in even low-light situations. The built-in cylinder content gauge is easy to read and always indicates oxygen cylinder pressure. Safety The OxyTOTE NG s SureClick feature locks in oxygen flow with accuracy, reducing the risk of positioning the Flow Selector between settings. The OxyTOTE NG s high impact polycarbonate shroud protects the regulator, gauge and hose barb from damage. The gauge and hose barb are also recessed as an added safeguard. The OxyTOTE NG also incorporates a check valve in the inlet port to prevent exposure to high pressure oxygen, as well as a high pressure shut-off valve and filtration throughout to extend regulator life. Reliable Accurate Oxygen Delivery The OxyTOTE NG is capable of accurately delivering 0.5-25 liters per minute of oxygen and is also equipped with a 50 psi DISS Demand Valve Outlet for oxygen delivery flexibility. Proven Reliability OxyTOTE NG represents the next generation of Integrated Valve Regulators manufactured by Western Enterprises. With a 15 year history and over one million Integrated Valve Regulators in the field, you can depend on OxyTOTE NG to perform when you need it most. E N T E R P R I S E S a Scott Fetzer company Toll Free: 877- OXY-7677 westernenterprises.com

Ready When You Are OxyTOTE NG Regulator Features High impact polycarbonate material protects regulator and components. Small Shroud with built in handle for portability. Will fit into tight spaces and most EMS bags. SureClick feature reduces the risk of positioning the Flow Selector between the discrete click flow settings, providing worry free operation to EMTs and clinicians. The Flow Selector knob is simple to operate and read, with 11 discrete flow rates from 0.5-25 LPM, plus AUX. Integrated brass regulator assembly incorporates cylinder valve and flow control regulator into a single unit. Units are refilled through a CGA-540 fill port on back of regulator body. The tapered hose barb outlet for attaching cannula is recessed for protection against damage. 5 Year Warranty Easy-to-read 1.5 oxygen content gauge is always active. The On/Off Knob has been redesigned. Light gray color is more visible inside of EMS bags and in low light areas. Permanently assembled onto a lightweight aluminum cylinder. OxyTOTE NG With DISS 1240 port Features Regulator and cylinder valve integrated into one unit User can initiate flow in two easy steps Compact design with all brass body Built-in Safety Burst Disk prevents over pressurization CGA-540 Fill Port with Safety Check Valve Filtration throughout for maximum safety and reduced particle contamination Protective shroud ensures safety and lasting performance 50 psi DISS Demand Valve Outlet 1.5 diameter oxygen content gauge continuously indicates cylinder pressure

The Next Generation OxyTOTE NG OxyTOTE NG Regulator Specifications (OxyTOTE NG Regulator only) Size 5.240 x 4.375 (5.989 x 4.375 including threads) Weight 2.14 lbs. OxyTOTE NG Flow (LPM) 0.5, 1, 1.5, 2, 3, 4, 6, 8, 10, 15, 25 Part# MNR-600 MNS-602 MNS-603* PX-1044 PX-1045 PX-1003 Description OxyTOTE NG regulator head only, with DISS Demand Outlet, ¾ -16UNF thread (aluminum cylinder) OxyTOTE NG system includes D size aluminum cylinder OxyTOTE NG system includes E size aluminum cylinder Humidification Attachment Sleeve Humidification Hose Humidification Bottle *The MNS-603 is MR Conditional for use 1.5 ft. or more outside of the bore of an MR machine under the following conditions: Static magnetic field of 3.0 Tesla or less and a spatial gradient field of 720 gauss/cm or less. OxyTOTE NG The Next Generation of Portable Oxygen Delivery Systems Finally, an oxygen delivery system that operates as easy and quickly as you do. OxyTOTE NG delivers oxygen in two easy steps. No hassles with wrenches, washers or attachments just a simple way for you to do your job and ensure your patient is getting the care they need quickly and efficiently. Confidence Designed and manufactured within a quality system registered to both ISO9001 and ISO13485 ensures OxyTOTE NG s performance, longevity, and total satisfaction. Made in USA OxyTOTE NG is manufactured and assembled in Westlake, OH. Warranty 5 years OxyTOTE NG with optional humidification attachment. MNS-603 MNS-602 E N T E R P R I S E S a Scott Fetzer company 875 Bassett Road Westlake, OH 44145 Toll Free: 877-OXY-7677 westernenterprises.com B20590 ECN-15047 (1009)