Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements

Similar documents
Documentation Beats Confrontation in Gas Detection

Atmospheric Hazards. Hazardous Atmosphere 3/29/2017. Oxygen deficiency and enrichment Flammable gases and vapors Toxic contaminants

Flow Vision I MX Gas Blending Station

Our Air- Why We Should Care!

Addressing Manure System Hazards and OSHA Compliance

CENTRAL ZONE OPERATIONS MANUAL

Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH

Introduction to Confined Space Safety OR-OSHA

Applications Note: Use of "pentane equivalent" calibration gas mixtures

Gases. Properties of Gases Gas Pressure

Tool Box Talk. Confined Space Entry New Construction Standard (2015)

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03

Confined Space. Program Responsibilities

"CONFINED SPACE ENTRY... A REFRESHER PROGRAM"

Safety Regulations and Procedures GENERAL SAFETY Confined Spaces - S New 11/96. To provide guidance for the safe entry of confined spaces.

1. Class "A" - an environment that is immediately dangerous to life of health. (Entry by permit only shall have a posted sign.)

Calibration and Bump Test Requirements for Direct Reading Portable Gas Monitors

Gas-Detection Instruments

Gas Detection Technology in Confined Spaces

GasLab SAN-102 Micro Oxygen Monitor User Manual

"CONFINED SPACE ENTRY"

Dr. Rogers Chapter 5 Homework Chem 111 Fall 2003

IRwin Methane Leak Detector. Innovation makes the difference

Instructions. To complete this independent study program, view the entire program, advancing through each slide by pressing the enter key.

PERMIT-REQUIRED CONFINED SPACES PROGRAM

Verification Of Calibration for Direct-Reading Portable Gas Monitors

( ) ADVANCED HONORS CHEMISTRY - CHAPTER 14 NAME: THE BEHAVIOR OF GASES GRAHAM'S LAW WORKSHEET - ANSWERS - V8 PAGE:

Confined Spaces. 1. Definition Permit/Non-Permit

GasLab SAN-102 Micro Oxygen Monitor User Manual

VIC offers a variety of Calibrated Gas Leaks

Mount Holyoke College. Confined Space Program

PSI Chemistry: Gases Multiple Choice Review

CONFINED SPACE PROGRAM

Mount Holyoke College. Confined Space Program

Dräger X-dock Frequently Asked Questions

TAMPA ELECTRIC COMPANY ENERGY SUPPLY CONFINED SPACE PROGRAM

Recent changes in the rules for confined space entry

Conceptual Physics Matter Liquids Gases

EH&S Program Occupational Safety Next Review: 5/9/19. Scope: University Wide Original date created: 2006

Under pressure pushing down

NITROGEN GENERATION FOR INDUSTRIAL APPLICATIONS

c) Loss of product or replacement when units are being serviced All of these are factors that need to be considered by the user.

Richland County School District One. Permit-Required Confined Space Entry Program (29 CFR Part )

Gas Tester Competent Person Course Outline

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee

Confined Space Entry Program 8 CCR 5157

UNIT 10 - GASES. Notes & Worksheets - Honors

UNIVERSITY OF RHODE ISLAND DEPARTMENT OF SAFETY & RISK MANAGEMENT STANDARD OPERATING PROCEDURE

Recommended Facilitator Notes: (read the following text out-loud to participants while showing this slide)

Agilent 490 Micro GC Natural Gas Analyzer

Section 8.1 Properties of Gases Goal: Describe the kinetic molecular theory of gases and the units of measurement used for gases.

(1) Is large enough and so configured that an employee can bodily enter and perform assigned work; and

GAS DETECTION: CALIBRATION GAS

Automatic Test and Calibration Station

Discovery HP-TGA 75/750. Site Preparation Guide

Description of saturation curves and boiling process of dry air

WEEKLY SAFETY MEETING

Technical Data for Alicat M-Series Mass Flow Meters sccm Full Scale through slpm Full Scale

Misuse of Combustible Gas Meters

Safety Tips from the WorkSafe People. Building a Safety Program for Your Organization

CP Chapter 13/14 Notes The Property of Gases Kinetic Molecular Theory

Gas-Detection Instruments

ISO INTERNATIONAL STANDARD. Welding consumables Gases and gas mixtures for fusion welding and allied processes

X-dock Software History

Phosgene Sensor. Sensoric COCl2 3E 1

User Manual. GPL 3000 e. gas detector

4.) There are no forces of attraction or repulsion between gas particles. This means that

Kinetic-Molecular Theory of Matter

ISO INTERNATIONAL STANDARD

Confined Space Entry The Good, The Bad, The Ugly!

Risk Management and Safety (RMS) Confined Space Entry Program May 1, 2009

Chemistry 1B Chapter 10 Worksheet - Daley. Name

Model Description

Chapter 22 Testing Protocols

Gases NO CALCULATORS MAY BE USED FOR THESE QUESTIONS

DENVER AMENDMENT PROPOSAL 2015 INTERNATIONAL CODES

Homework Chapter 07 Chemistry 51 Los Angeles Mission College

Confined Space Entry Procedure

CONFINED SPACE ENTRY PROGRAM CSU CHANNEL ISLANDS

Safety Meeting Topic #11 Hazards of Confined Space

CONFINED SPACE WRITTEN PROGRAM

RISK ENGINEERING TECHNICAL GUIDE

CONFINED SPACE PROGRAM

CHM 111 Unit 5 Sample Questions

Chemistry Chapter 11 Test Review

Duke University - Facilities Management Department Environmental Safety and Health Program CONFINED SPACE PROGRAM

Gas Law Worksheets - WS: Boyle s and Charles Law

INDUSTRIAL HYGIENE GROUP Standard Operating Procedure. TVA-1000 PID/FID Portable Toxic Vapor analyzer. 1 of 9. Contents

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Gas monitoring using GASMET FTIR

PUBLIC COMPANY ORLEN LIETUVA OCCUPATIONAL HEALTH AND SAFETY PROCEDURE BDS-12 USE OF PORTABLE GAS ANALYZERS I. GENERAL

Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such activities.

Boyle s Law Practice

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

Kinetic-Molecular Theory

Confined Space Plan Environmental Health & Safety Office July 2017

City & County of San Francisco Office of Contract Administration Purchasing. Bid #: ITSF /CD Req #: RQUH Attachment B

Date: Period: Gas Laws Worksheet #1 - Boyle s, Charles, Gay-Lussac s, and Combined Gas Law

OSHA must prove. Confined Space Entry. Do you have an effective safety and health program? Some period of time later

Transcription:

Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements

Why is Gas Detection Important?

Spot the hazard

Composition of Fresh Air Name Symbol Percent by Volume Nitrogen N 2 78.08% Oxygen O 2 20.95% Argon Ar 0.93% Carbon Dioxide CO 2 0.03% Neon Ne 0.00% Methane CH 4 0.00% Helium He 0.00% Krypton Kr 0.00% Hydrogen H 2 0.00% Xenon Xe 0.00%

Confined Space Entry Requirements OSHA 29 CFR 1910.146 Permit-Required Confined Spaces Periodic atmospheric monitoring? Best practice: Continuous Monitoring!

OSHA 29 CFR 1926 New Construction Industry Rule

What are your customers looking for? Ease of use One button operation Simplified training Compliance Quality Compliance at a glance Tamper-proof settings HOS World-class manufacturing SAFETY Durability Rugged design Designed for harsh environments Low cost of ownership Automated fleet management Low or zero maintenance

One of these monitors will detect the hazardous atmosphere but the other may not choose wisely! The one with Visual Compliance Monitoring Green means in compliance and good to go!

Calibration, Bump Test and Verification Calibration: The adjustment of an instrument s response to match a desired value compared to a known concentration of test gas Bump test: Briefly applying gas to check that each sensor responds to target gas and that the alarms are working Calibration Verification: A bump test utilizing a known concentration of a challenge gas to demonstrate that an instrument s alarms are activated and response to gas is within acceptable limits DOCUMENT ALL TESTING IF IT WASN T DOCUMENTED IT DIDN T HAPPEN https://www.osha.gov/dts/shib/shib093013.html

What is your Instrument Management System?

Docking stations increasing in popularity Automatic bump testing, calibration, record storage and charge monitors Safety professionals are often required to show evidence of up to date monitor calibration and bump test history Docking stations provide objective evidence that procedures are being followed

Instrument Management Software Although some docking stations do not require a computer to operate They can be connected to a network and regularly downloaded for management of a fleet of gas monitors This software in conjunction with the docking station allows users to Import event and data logs from monitors Save bump and calibration results Generate bump test and calibration certificates Detector status reports Manage users and base stations Configure detectors Archive and save database

Confined Space Atmospheric Monitoring

Confined Space Entry Characteristics of Confined Spaces Large enough for worker to enter Are not designed for continuous worker occupancy Limited openings for entry and exit

Permit Required Confined Spaces One or more of the following: Hazardous atmosphere (known or potential) Material with the potential for engulfment Inwardly sloping walls or dangerously sloping floors or Contains any other serious safety hazard

Vapor Density Lighter than air Hydrogen Methane Ammonia Measure of a vapor s weight compared to air Propane Hydrogen sulfide Gasoline Gases lighter than air tend to rise; gases heavier than air tend to sink Heavier than air

T90 Sensor Performance

Pre-testing a Confined Space Atmospheric hazards in confined spaces form layers Check all levels! Atmosphere tested (at least) a distance of approximately 4 feet (1.22 m) in the direction of travel and to each side Allow sufficient time for all sensors to react to each sample per level tested. Key response factors are hose length (typical 2 seconds per foot flow rate) plus T90 sensor/s response time (minimum) to 2 min. for full response if any gas is present. For Example: 10 hose x 2 seconds = 20 seconds plus most significant T90 of monitor s sensors (typically 30 seconds for standard 4-gas monitor). (10 x 2) + 30 = 50-140 seconds per level (T 100 if any gas is present)

Important Resource Links http://www.honeywellanalytics.com http://www.raesystems.com/ http://www.honeywellanalytics.com/en/support/training-andsupport http://hautraining.litmos.com/online-courses http://www.citytech.com http://www.cdc.gov/niosh/npg/ https://www.osha.gov/dts/shib/shib093013.html https://www.osha.gov/dsg/annotated-pels/index.html https://safetyequipment.org/

Summary: Understand your potential atmospheric hazards Use an appropriate gas monitor that has been validated per OSHA SHIB 09302013 Perform a proper pre-test of the confined space don t rush it! Continuously monitor the atmosphere while occupied Establish and maintain a documented Instrument Management system.

Questions? Answers.