GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM

Similar documents
DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM

N SERIES PROCESS VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

MINI GAS SAMPLING PUMPS WITH DOUBLE DIAPHRAGM SYSTEM

MINI DIAPHRAGM VACUUM PUMPS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

MINI DIAPHRAGM VACUUM PUMPS

MICRO DIAPHRAGM GAS PUMPS

Diaphragm-Gas Sampling Pumps with double diaphragm System N 0150 AN.12 E N 0150 ST.12 E N AN.12 E N ST.12 E

MICRO DIAPHRAGM GAS PUMPS

Diaphragm Vacuum Pumps and Compressors

Diaphragm-Gas Sampling Pumps with double diaphragm System N 143 AN.12 E N 143 AV.12 E. N 143 SN.12 E N 143 SV.12 E Operating and

Willkommen. Welcome to KNF - presentation

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Diaphragm Vacuum Pump

Liquid ring compressors

Liquid ring vacuum pumps in compact design

SIHI LPH-X - Liquid Ring Compressors

Liquid ring compressor

Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860

Liquid ring vacuum pumps single-stage

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

4/2 way Pneumatic Solenoid Valve

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003

Liquid Ring Compressors Engineered-to-Order Compressor Systems

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

MULTI-STAGE VACUUM GENERATORS PVP 12 MX and 25 MX

Diaphragm Accumulators

Liquid Ring Compressors Engineered-to-Order Compressor Systems

SITRANS P measuring instruments for pressure

h2000 plus HyDROGEN LEAk DETECTOR

MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET NF 100/1.100 NF 100 / 1.100

Differential pressure gauge For the process industry Model , all-metal media chamber

Instruction Manual Contact Pressure Vacuum Gauge

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Premium Solutions for Gas and Biogas Handling

ASB Accumulator Safety Blocks

SERIES 3000 BLANKET GAS REGULATORS

Series IRV1000/2000/3000

CAT-W Iwaki pneumatic drive bellows pumps

[Graphic Division] 10

Pressure controls for hydro carbons, zone II applications, Type KPE

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

GasMultiBloc Combined regulating and safety valve Infinitely variable air/gas ratio control mode MB-VEF B01

Liquid Ring Compressors Engineered-to-Order Compressor Systems

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

NGN Series nitrogen generator

OPTIBAR P 1010 C Technical Datasheet

ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying

Compressor Systems for Offshore Oil & Gas Production

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

Pressure Sensing Valve - Model 4023

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Mechanical Pressure Measurement

Pressure controls, differential pressure controls type RT

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet

cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated

Pressure gauges EN All stainless steel construction PBX100, PBX150 (1.18) Functional and constructive characteristics

2-Port Seat Valves with Flange, PN 16

CNG FILLING STATIONS

Operating Manual VSA100A. tina29e1 ( )

BULLETIN E485B. Poppet Valve Construction Customized Solutions Plug-and-Play Design. Subject to technical modifications.

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Aperval Pressure Regulators

Solenoid valve type EVR for Hydrocarbons

Gas Pressure Regulator HON 200

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

Solenoid valves VZWF, force pilot operated

HydroCOM: High energy savings and excellent controllability

COMPRESSED AIR SINCE 1919 GAS COMPRESSORS. Rotary vane technology

2-Port Seat Valves with Flange, PN 16

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Compressed Airline Breathing Apparatus

CAMASS. Calibration Centre. Gas flow technology and services

INSTRUM. Pressure regulators Flow restrictors Safety elements. For protecting explosive, corrosive and sterile processes with inert gases

Pneumatic pressure switch 20DD

PRESSURE & TEMPERATURE GAUGES PRESSURE TEMPERATURE. Catalogue H20200a

Transcription:

GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM DATA SHEET E065 Cutaway - Double diaphragm pump Concept The Diaphragm Vacuum Pumps from KNF are based on a simple principal - an elastic diaphragm, fixed on its edge, moves up and down its central point by means of an eccentric. In this way the medium is transferred using automatic valves. The KNF Double Diaphragm System for increased safety A second diaphragm is located underneath the working diaphragm. If gas should leak at the working diaphragm, it will still remain inside the pump space. Thanks to the KNF Modular System, the parts used to transfer the gases can be made from materials with varying degrees of durability. The customer has a choice of pump drives ranging from a selection of motors models. Please contact us for further details. Explosion protection pumps in ATEX on request. Features Pure transferring, evacuation and compression of air, gases and vapours - no contamination of the media due to oil-free operation Increased safety by KNF double diaphragm system High level of gas tightness: Leak rate from < 6 x 10-6 mbar l/s Long product life Low maintenance Very quiet and little vibration Cool running motor even when in constant use Can operate in any installed position Areas of use These Diaphragm Pumps for analysis and process gases offer a high level of performance despite their small size, as well as an excellent price performance ratio. They are used especially in the fields of chemical, chemical, environmental, energy and production technology. Pumps with the KNF Double Diaphragm System are employed for expensive, toxic and dangerous gases. Double diaphragm pumps in ATEX for potentially explosive atmospheres on request. Please contact us for details. Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar absolute) Press. (bar g) (kg) N 143 AN.12E 30 100 3 13.0 N 186.3 AN.12E 30 3 18.0 N 186.1.2 AN.12E 50 100 3 18.5

N 143 12E N 186.3.12E Type and Order No. 2) Delivery Max. operating Ultimate at atm. pressure pressure vacuum (l/min) 1) (bar g) (mbar abs.) N 143 AN.12E 30 3 100 N 143 AV.12E 30 3 100 N 143 SN.12E 30 3 100 N 143 SV.12E 30 3 100 1) Litre at STP Type and Order No. 2) Delivery Max. operating Ultimate at atm. pressure pressure vacuum (l/min) 1) (bar g) (mbar abs.) N 186.3 AN.12E 30-3 N 186.3 AV.12E 30-3 N 186.3 SN.12E 30-3 N 186.3 SV.12E 30-3 1) Litre at STP MOTOR DATA Protection class IP 44 IP 44 Voltage/Frequency (V/Hz) ~230/50 3~230/400/50 Power P 1 (W) 300 420 Operating current (A) 2,2 2,4/1,2 MOTOR DATA Protection class IP 44 IP 44 Voltage/Frequency (V/Hz) ~230/50 3~230/400/50 Power P 1 (W) 360 400 Operating current (A) 2,0 1.9/1.1 MODEL CODES AND MATERIALS Type and Order No. 2) Pump head Diaphragm Valves N 143 AN.12E Aluminium Neopren Neopren N 143 AV.12E Aluminium Viton Viton N 143 SN.12E Stainless steel Neopren Neopren N 143 SV.12E Stainless steel Viton Viton MODEL CODES AND MATERIALS Type and Order No. 2) Pump head Diaphragm Valves N 186.3 AN.12E Aluminium Neopren Neopren N 186.3 AV.12E Aluminium Viton Viton N 186.3 SN.12E Stainless steel Neopren Neopren N 186.3 SV.12E Stainless steel Viton Viton 2) See also MODEL CODE FOR EASY ORDERING Dimensions 3) (mm) 3) All dimensional tolerances conform to DIN ISO 2768-1, Tolerance Class V Vacuum atm. Press. Flow capacity l/min (Litre at STP) mbar

N 186.1.2.12E Type and Order No. 2) Delivery Max. operating Ultimate at atm. pressure pressure vacuum (l/min) 1) (bar g) (mbar abs.) N 186.1.2 AN.12E 50 3 100 N 186.1.2 AV.12E 50 3 100 N 186.1.2 SN.12E 50 3 100 N 186.1.2 SV.12E 50 3 100 1) Litre at STP MOTOR DATA Protection class IP 44 IP 44 Voltage/Frequency (V/Hz) ~230/50 3~230/400/50 Power P 1 (W) 360 400 Operating current (A) 2,0 1.9/1.1 MODEL CODES AND MATERIALS Type and Order No. 2) Pump head Diaphragm Valves N 186.1.2 AN.12E Aluminium Neopren Neopren N 186.1.2 AV.12E Aluminium Viton Viton N 186.1.2 SN.12E Stainless steel Neopren Neopren N 186.1.2 SV.12E Stainless steel Viton Viton Pressure Flow capacity l/min (Litre at STP) For pipe OD 10x1.5 bar

Technical Informations Pump down time for 20 l receiver MODEL CODE FOR EASY ORDERING The model code is identical to the order number. It is set up as follows: N 143 _.12 N 186.3 AN.12 E 230 V/50 Hz, IP 44 N 186.1.2 _.12 N 186.3 _.12 mbar Base model Head connections Head materials Double diaphragm system OEM version with ac motor (E) Other motor data e.g.: min In addition the motor data must be given in the purchase order (voltage, frequency, and protection class). In our extensive program you are sure to find the pump you need for your particular application. Head connections TECHNICAL DETAILS Maximum permissible gas and ambient temperature: between +5 C and +40 C. Motors with other voltages, frequencies and protection classes on request. A ACCESSORIES Silencer for G1/4 Order No. 000352 Wrench for retainer plate Order No.018816 G 1/4 N 186.3.12 Heads in series (2-stage) N 186.1.2.12 Heads in parallel both side A = Compressing pipe caupling for pipe OD 10 KNF - the competent partner for vacuum and compressor technology. Especially for unusual problems. Call us and talk to our application engineers.

HINTS ON FUNCTION, INSTALLATION AND SERVICE FUNCTION OF KNF DIAPHRAGM VACUUM PUMPS AND COM- PRESSORS An elastic diaphragm is moved up and down by an eccentric (see illustration). On the down-stroke it draws the air or gas being handled through the inlet valve. On the up-stroke the diaphragm forces the medium through the exhaust valve and out of the head. The compression chamber is hermetically separated from the drive mechanism by the diaphragm. The pumps transfer, evacuate and compress completely oil-free. Diaphragm pump HINTS ON INSTALLATION AND OPERATION Range of use: Transferring air and gases at temperatures between +5 C and +40 C. Please check the compatibility of the materials of the pump head, diaphragm and valves with the medium. The KNF product line contains pumps suitable for pumping aggressive gases and vapors - please contact us. Permissible ambient temperature: between +5 C and +40 C. The standard pumps are not suitable for use in areas where there is a risk of explosion. In these cases there are other products in the KNF program - please ask us for details. To prevent the maximum operating pressure being exceeded, restriction or regulation of the gas flow should only be carried out in the suction line. Components connected to the pump must be designed to withstand the pneumatic performance of the pump. Install the pump so that the fan can draw in sufficient cooling air. Fit the pump at the highest point in the system, so that condensate can not collect in the head of the pump. HINTS ON SERVICE The diaphragm and valve plates are the only parts of the KNF diaphragm pumps subject to wear. They are easy to change, as no special tools are needed. If you have any questions, please call our application engineers (see below for contact telephone number). Double diaphragm pump THE KNF DOUBLE DIAPHRAGM SYSTEM FOR INCREASED SAFETY A second diaphragm is located underneath the working diaphragm. This second diaphragm is under less mechanical stress when the pump is operating. If gas should leak at the working diaphragm, it will still remain inside the pump space. The space between both diaphragms can be monitored so that any damage to the working diaphragm will be noted immediately. Pumps with the KNF Double Diaphragm System are employed for expensive, toxic and dangerous gases. Please contact us for details. KNF Neuberger GmbH Alter Weg 3 D 79112 Freiburg Tel. ++49 (0)7664/5909-0 Fax ++49 (0)7664/5909-99 E-mail: info@knf.de www.knf.de KNF reserves the right to make changes. O 11/2012 Printed in Germany

YOUR LOCAL PARTNER AROUND THE WORLD KNF SALES ORGANIZATION Australia KNF Regional Office Moreland West VIC 3055 Tel. +61 3 9386 4959 info@knf.com.au www.knf.com.au Benelux Netherlands KNF Verder B.V. 3451 GG Vleuten Tel. +31 30 677 92 40 info@knf-verder.nl www.knf-verder.nl India KNF Pumps + Systems (India) Pvt. Ltd. Hinjewadi Pune 411 057 Tel. +91 20 640 13 923 info@knfpumps.in www.knfpumps.in Italy KNF Italia S.r.l. 20063 Cernusco s. Naviglio (MI) Tel. +39 02 929 04 91 info@knf.it www.knf.it Singapore KNF Regional Office Tel. +65 9722 1994 info@knf.com.sg www.knf.com.sg Sweden, Finland, Denmark, Norway KNF Neuberger AB 117 43 Stockholm Tel. +46 8 744 51 13 info@knf.se www.knf.se Benelux Belgium and Luxemburg KNF Verder N.V. 2630 Aartselaar Tel. +32 3 871 96 24 info@knf.be www.knf.be China KNF Technology (Shanghai) Co., Ltd. Shanghai 201203 Tel. +86 21 5109 9695 info@knf.com.cn www.knf.com.cn France KNF Neuberger SAS 68128 Village-Neuf Tel. +33 389 70 35 00 info@knf.fr www.knf.fr Germany KNF Neuberger GmbH 79112 Freiburg Tel. +49 7664 5909 0 info@knf.de www.knf.de Japan KNF Japan Co. Ltd. Tokyo 104-0033 Tel. +81 3 3551 7931 info@knf.co.jp www.knf.co.jp Korea KNF Neuberger Ltd. 135-502 Seoul Tel. +82 2 959 0255 knf@knfkorea.com www.knfkorea.com Latin America KNF Regional Office Tel. +1 609 649 1010 gb@knf.com www.knf.com/es Morocco, Tunisia, Algeria KNF Neuberger SAS 68128 Village-Neuf Tel. +33 389 70 35 00 info@knf.fr www.knf.fr Switzerland KNF Neuberger AG 8362 Balterswil Tel. +41 71 973 99 30 knf@knf.ch www.knf.ch UK, Ireland KNF Neuberger U.K., Ltd. Witney, Oxfordshire OX28 4FA Tel. +44 1993 77 83 73 info@knf.co.uk www.knf.co.uk USA, Canada KNF Neuberger, Inc. Trenton, NJ 08691-1810 Tel. +1 609 890 8600 knfusa@knf.com www.knfusa.com KNF PRODUCT CENTERS Gas Pumps KNF Neuberger GmbH DE-79112 Freiburg info@knf.de www.knf.de Micro Gas Pumps KNF Micro AG CH-6260 Reiden info@knf-micro.ch www.knf-micro.ch Liquid Pumps KNF Flodos AG CH-6210 Sursee info@knf-flodos.ch www.knf-flodos.ch