Robust Remote Measurement of Respiratory Rate Using Infrared Thermography

Similar documents
Figure 2: Principle of GPVS and ILIDS.

Open Research Online The Open University s repository of research publications and other research outputs

Image-Based Measurement of Alveoli Volume Expansion in an Animal Model of a Diseased Lung

OPERATIONAL AMV PRODUCTS DERIVED WITH METEOSAT-6 RAPID SCAN DATA. Arthur de Smet. EUMETSAT, Am Kavalleriesand 31, D Darmstadt, Germany ABSTRACT

An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system

FieldStrength. Using MotionTrak for motion correction in body imaging. Application tips

High-Resolution Measurement-Based Phase-Resolved Prediction of Ocean Wavefields

Technical Note. Determining the surface tension of liquids by measurements on pendant drops

IEEE RAS Micro/Nano Robotics & Automation (MNRA) Technical Committee Mobile Microrobotics Challenge 2016

Non-contact, Wavelet-based Measurement of Vital Signs using Thermal Imaging

Developing an Effective Quantification Method of Tongue Deviation Angle to Assess Stroke Patients

Automated analysis of microscopic images of cellular tissues

Smart-Walk: An Intelligent Physiological Monitoring System for Smart Families

IMAGE-BASED STUDY OF BREAKING AND BROKEN WAVE CHARACTERISTICS IN FRONT OF THE SEAWALL

A CO 2 Waveform Simulator For Evaluation and Testing of Respiratory Gas Analyzers

E. Agu, M. Kasperski Ruhr-University Bochum Department of Civil and Environmental Engineering Sciences

Dynamic 3D Print of the Breathing Function

Vibration Analysis and Test of Backup Roll in Temper Mill

HIGH RESOLUTION DEPTH IMAGE RECOVERY ALGORITHM USING GRAYSCALE IMAGE.

Detecting Aged Person s Sliding Feet from Time Series Data of Foot Pressure

A Bag-of-Gait Model for Gait Recognition

PEDESTRIAN behavior modeling and analysis is

Neural Network in Computer Vision for RoboCup Middle Size League

Design of a Pedestrian Detection System Based on OpenCV. Ning Xu and Yong Ren*

EVALUATION OF ENVISAT ASAR WAVE MODE RETRIEVAL ALGORITHMS FOR SEA-STATE FORECASTING AND WAVE CLIMATE ASSESSMENT

SEA-LEVEL AND SEA-STATE MEASUREMENTS WITH RADAR LEVEL SENSORS. Dr. Ulrich Barjenbruch 1 and Jens Wilhelmi 2

Video Based Accurate Step Counting for Treadmills

THe rip currents are very fast moving narrow channels,

SCHEINWORKS Measuring and Analysis Systems by

On Spectral Analysis of Heart Rate Variability during Very Slow Yogic Breathing

Yoke Instrumentation: ILD Muon System / Tail Catcher. Valeri Saveliev IAM, RAS, Russia DESY, Germany 3 June, 2016

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Modelling of Extreme Waves Related to Stability Research

INTRODUCTION TO PATTERN RECOGNITION

Pendant Drop Measurements

Characterizing Ireland s wave energy resource

PUV Wave Directional Spectra How PUV Wave Analysis Works

Geometric moments for gait description

Heart Rate Estimation Using Wrist-acquired Photoplethysmography Under Different Types of Daily Life Motion Artifact

Naval Postgraduate School, Operational Oceanography and Meteorology. Since inputs from UDAS are continuously used in projects at the Naval

ADVANCES IN NDT TECHNIQUES FOR FRICTION STIR WELDING JOINTS OF AA2024

Development of virtual 3D human manikin with integrated breathing functionality

Recognition of Tennis Strokes using Key Postures

DP Ice Model Test of Arctic Drillship

Maria Soroko a Kevin Howell b Anna Zwyrzykowska c Krzysztof Dudek d Paulina Zielińska d Zbigniew Dobrzański c

Using an Adaptive Thresholding Algorithm to Detect CA1 Hippocampal Sharp Wave Ripples. Jay Patel. Michigan State University

Combined impacts of configurational and compositional properties of street network on vehicular flow

Lab 4: Pressure Gradients over a Wing

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

Special edition paper

DEPARTMENT OF THE NAVY DIVISION NEWPORT OFFICE OF COUNSEL PHONE: FAX: DSN:

Name. Lab Partners. The Dive Response. In this lab exercise, you will be designing and conducting your own experiments!

SPIRIT III Radiometer Saturation Effect

Data Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic

A study of advection of short wind waves by long waves from surface slope images

Surface-based Respiratory Motion Classification and Verification

A Conceptual Approach for Using the UCF Driving Simulator as a Test Bed for High Risk Locations

Bloodpressure measurement, improvement of oscillometric method.

Respiration. Figure 22: Schematic representation of the respiratory system

ISOLATION OF NON-HYDROSTATIC REGIONS WITHIN A BASIN

Non-contact detection of oxygen saturation based on visible light imaging device using ambient light

Bio-Effluents Tracing in Ventilated Aircraft Cabins

1 INEGI Instituto de Engenharia Mecânica e Gestão Industrial, Porto, Portugal, FEUP Faculdade de Engenharia,

Measuring Lung Capacity

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

ANALYSES OF THERMAL COMFORT AND INDOOR AIR QUALITY UNDER STRATUM, DISPLACEMENT, AND MIXING VENTILATION SYSTEMS

IDeA Competition Report. Electronic Swimming Coach (ESC) for. Athletes who are Visually Impaired

EXPERIMENTÁLNÍ ANALÝZA MLP SÍTÍ PRO PREDIKCI POHYBU PLIC PŘI DÝCHÁNÍ Experimental Analysis of MLP for Lung Respiration Prediction



Increased streamer depth for dual-sensor acquisition Challenges and solutions Marina Lesnes*, Anthony Day, Martin Widmaier, PGS

New Highly Productive Phased Array Ultrasonic Testing Machine for Aluminium Plates for Aircraft Applications

Wind Flow Validation Summary

Exercise load research on common technical method in taekwondo training courses

Gas exchange measurement in module M- COVX

PARAMETRIZATION OF WAVE TRANSFORMATION ABOVE SUBMERGED BAR BASED ON PHYSICAL AND NUMERICAL TESTS

Reprocessed QuikSCAT (V04) Wind Vectors with Ku-2011 Geophysical Model Function

DETRMINATION OF A PLUNGER TYPE WAVE MAKER CHARACTERISTICE IN A TOWING TANK

Dynamics of the bubble near a triangular prism array

Tutorial for the. Total Vertical Uncertainty Analysis Tool in NaviModel3

Measurement of Bubble Velocity using Spatial Filter Velocimetry

Towards determining absolute velocity of freestyle swimming using 3-axis accelerometers

Development of a Non-Destructive Test Machine for Testing Tunnel Lining Concrete

THE PRIMARY SOURCES OF SHIP NOISE OBSERVED ON THE BOTTOM OF SEA KAROL LISTEWNIK

New power in production logging

Tokyo: Simulating Hyperpath-Based Vehicle Navigations and its Impact on Travel Time Reliability

DESIGN OF REMOTE CONTROL SYSTEM FOR FAR-INFRARED LASER INTERFEROMETER

Flow in a shock tube

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

Aalborg Universitet. Published in: Proceedings of Offshore Wind 2007 Conference & Exhibition. Publication date: 2007

Numerical Simulations of a Three-Lane Traffic Model Using Cellular Automata. A. Karim Daoudia and Najem Moussa

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)

Electromyographic (EMG) Decomposition. Tutorial. Hamid R. Marateb, PhD; Kevin C. McGill, PhD

OPTIMIZATION OF INERT GAS FLOW INSIDE LASER POWDER BED FUSION CHAMBER WITH COMPUTATIONAL FLUID DYNAMICS. Abstract. Introduction

Wave phenomena in a ripple tank

Non-invasive, spatio-temporal gait analysis for sprint running using a single camera

Effects of seam and surface texture on tennis balls aerodynamics

7 th International Conference on Wind Turbine Noise Rotterdam 2 nd to 5 th May 2017

EWGAE 2010 Vienna, 8th to 10th September

Transcription:

POSTER 216, PRAGUE MAY 24 1 Robust Remote Measurement of Respiratory Rate Using Infrared Thermography Xinchi YU 1, Carina B. PEREIRA 1 1 Chair for Medical Information Technology, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstr. 2, 5274 Aachen, Germany yu@hia.rwth-aachen.de, pereira@hia.rwth-aachen.de Abstract. The demand for contactless and unobtrusive techniques for vital signs monitoring has increased during the last years. Current approaches for contactless respiration monitoring mostly detect respiration in the area around the nostrils. This implies that the nostrils must be in the camera s field of view, which however is not always the case. In this paper, we present a novel approach for robust remote respiratory rate monitoring using infrared thermography. Instead of identifying and tracking the nostrils in thermal video sequences, we use a grid-based approach to detect respiration-induced motion and use sensor fusion to obtain a robust estimate for the respiratory rate. Hence, our method does not require the nostrils to be in the camera s field of view and thus widens the range of possible applications. We evaluated our algorithm in a small preliminary study and obtained excellent results. During normal breathing a mean RMSE of.36 min 1 and mean correlation of.98 were achieved, while during simulation of different respiration patterns such as Cheyne-Stokes respiration and tachypnea the mean RMSE was around 3.98 min 1 and mean correlation was around.92. In summary, our algorithm is a promising approach to an easily applicable contactless and unobtrusive respiratory rate monitoring. Furthermore, our method is completely passive and robust against variations in ambient light due to the principle of infrared thermography. Keywords Infrared thermography, remote respiratory rate monitoring, signal processing, sensor fusion 1. Introduction Respiration is an important metabolic process in order to supply the human body with oxygen and remove products of metabolism from blood circulation. Furthermore, irregularities in respiration can be an initial indication for various illnesses. For example, Cheyne-Stokes respiration, which is characterized by (a) an increase in depth of inspiration followed by (b) a decrease in depth of inspiration and finally followed by (c) a phase of apnea, can be attributed to cardiac insufficiency or cerebral damage [1]. Therefore, respiration and respiratory rate are crucial vital signs that need to be constantly monitored on patients. According to the state of the art, technology for respiration monitoring such as impedance pneumography require the use of adhesive electrodes, which can trigger skin disorders or allergic reactions. Moreover, it is impossible to attach adhesive electrodes to patients with burns or neonates due to their extremely sensitive skin. Hence, the need for more widely and more comfortably applicable respiration monitoring methods is obvious. Approaches for contact-free respiration monitoring in current literature include camera-based systems in the visible light [2], near-infrared [3] and far-infrared spectrum [4]. In this paper we present a new method for respiratory rate monitoring based on infrared thermography. The main advantages of the usage of infrared thermography / far infrared over visible light or near infrared is the absolute passivity of the measurement principle (i.e. no active illumination required) and robustness against variances in ambient light conditions. Current proposals for respiratory rate monitoring by infrared thermography such as [5] as well as our previous work [6] mainly use the thermal information around the nostrils. However, this information may be unavailable due to the patient breathing through the mouth or the nose being outside the camera s field of view. Our new algorithm aims to increase robustness by the introduction of a black box approach which works directly without the need to detect and track anatomic landmarks or specific feature points. For that we divided the image into a regular grid and extracted the respiration waveform from each grid cell based on the respiration-induced movement of the human body (e.g. shoulder [7]). The signals were automatically analysed with regard to their quality and the respiratory signal as well as the respiratory rate were computed from the grid cell with the best signal quality. Section 2 describes our methods in detail, while section 3 details our experimental setup. The results of our experiments are presented in section 4. Finally, the results are discussed in section 5 and a brief outlook is given.

2 X. YU, C. B. PEREIRA, Robust Remote Measurement of Respiratory Rate Using Infrared Thermography 2. Materials and Methods 2.1. Image processing and acquisition of respiration waveform Since the detection of breathing-induced motion (e.g. around the shoulders and head) in thermal video sequences is crucial to our algorithm, we first need to separate the subject s body from the background in each frame of the thermal video. For that we used the fact that the human body is significantly warmer than the background. Hence, we could to use Otsu s method [8] to convert each video frame into a binary image consisting only of the background and the subject s body (see fig. 1). After the conversion a X by Y pixels sized regular grid is layed over the image and the respiration waveform for each cell is calculated according to s c (t) = 1 X Y X x=1 y=1 Y I c,bin (x, y, t) (1) where s i (t) is the respiration waveform of cell c at a given time t and I c,bin is the area of the binary image which corresponds to cell c. the respiratory rate r resp,c [min 1 ] in each cell c is defined according to r resp,c = 6 f(s c,norm (f) = max(s c,norm (f)) s.t..1 Hz f 3 Hz. Iterated over time, this algorithm corresponds to a short time fourier transform (STFT). The window size of 15 seconds results in a good trade-off between observation period and stationarity, while the hamming window reduces the influence of side maxima. The frequency boundaries correspond to respiratory rates between 6 and 18 breaths per minute. While the upper limit covers all possible physiological respiratory rates, the lower limit is restricted by the window length. A dedicated algorithm was implemented for apnea detection. In order to assess the signal quality, the fourier spectrum was normalized. Since spectral components with a frequency above 3 Hz (henceforth denoted as HF-band) can be attributed to noise, this frequency band in particular is of interest for the analysis of signal quality. Depending on the frequency distribution of the normalized spectrum S c,norm (f) in the HF-band, a normalized signal quality index with values in the range of [, 1] is computed. While a SQI of 1 indicates a very good signal quality, the SQI s value decreases with increasing noise until a value of zero indicates a very bad (noisy) respiration waveform. Finally, the overall respiratory rate is taken from the cell with the highest signal quality index. (6) Fig. 1. Left: Original infrared thermogram. Right: Binary version of thermogram. 2.2. Calculation of respiratory rate and Signal Quality Index (SQI) In order to calculate the respiratory rate in each grid cell c, an analysis window s c,w consisting of the most recent 15 seconds of the respiration waveform, was used for analysis s c,w (t) = t t=t 15 s c (t) δ(t t). (2) 3. Experimental Setup The infrared thermal video sequences were acquired using a long wave infrared (LWIR) camera (Infratec VarioCAM HD Head 82S/3mm, InfraTec GmbH, Dresden, Germany). The camera has an uncooled infrared microbolometer focal plane array with a spatial resolution of 124 x 768 pixels and a spectral range of 7.5-44 µm. In addition, the thermal sensitivity at 3 C is better than.5 K and the images were recorded at 3 frames per second (fps). A preliminary study was carried out with the two authors as healthy subjects. The subjects were sitting on a chair facing the camera, which was placed on a tripod 2m away in front of them. Two video sequences were recorded from The analysis window was mean centered s c,w (t) = s c,w (t) s c,w (t) (3) and multiplied with a hamming window h w (t) before being transformed into the frequency domain: S c (f) sc,w (t) h w (t). (4) Respiration A B C D E F G H I Time [min] Based on the normalized spectrum S c,norm (f) S c,norm (f) = S c (f) max(s c (f)) (5) Fig. 2. Schematic visualization of simulated respiration patterns during the second sequence. Eupnea: segments A, C, F, I. Tachypnea: segments B, H. Kussmaul respiration: segment D. Apnea: segment E. Cheyne-Stokes respiration: segment G.

POSTER 216, PRAGUE MAY 24 3 each subject: In the first sequence (9 minutes), the subjects were sitting still and initially only breathing through the nose (3 min). In the next 3 minutes the subjects only breathed through the mouth and in the last 3 minutes the subjects breathed through the nose and mouth simultaneously. In order to investigate the performance of our method during different types of respiration, the subjects simulated different physiologic and pathologic breathing patterns (eupnea, tachypnea, apnea, Kussmaul respiration and Cheyne- Stokes respiration) during the second sequence (1 minutes, see fig. 2). Ground truth was obtained with a piezoplethysmograph (Weinmann Somnolab 2, Weinmann GmbH, Hamburg, Germany), which recorded the thoratic effort. 4. Results The algorithms described above were implemented and evaluated in Matlab R215a (The MathWorks Inc., Natick, MA, USA). Figure 3 shows an example for grids cells where respiration was detected. The areas with respiration are the cells around the shoulder and head as expected and referenced in literature [7] [2]. Subject 1st sequence 2nd sequence RMSE Correlation RMSE Correlation 1.49.97 4.11.91 2.22.99 3.85.92 mean.36.98 3.98.92 Tab. 1. Results for both the first and second sequence for the first sequence, where the subjects were breathing normally through the nose and/or mouth, are very good showing a low RMSE and very high correlation. Furthermore, the absolute difference between our results and the ground truth was less than 1 breath per minute in 98.69% of the recording time for the first subject and 1% for the second subject. Figure 4 shows a Bland-Altman plot for both subjects. The low bias of.4 min 1 and the small limits of agreement (-.97-1.5 min 1 ) stress the good results based on the RMSE and correlation. Only very few outliers are existent. Differences [min -1 ] 1 5-5 8 1 12 14 16 18 Mean values [min -1 ] Fig. 4. Joint Bland-Altman plot of both subjects for the first sequence Fig. 3. Example of grid cells with detected respiration. The respiration signal in the highlighted (red) cell is visualized at the top part of fig. 5. Table 1 shows the results of a quantitative analysis of our algorithms for both subjects in our preliminary study. We used the root mean squared error (RMSE) n i=1 (s(i) ref(i))2 RMSE = (7) n as a metric for the precision between our result s and the ground truth ref. Furthermore, we also evaluated the correlation n i=1 (s(i) s)(ref(i) ref) ρ = n i=1 (s(i) s)2 n i=1 (ref(i) (8) ref)2 between our result s and the ground truth ref. The results The results for the second sequence, where the subjects simulated different physiologic and pathologic respiration patterns, are still very good, although the RMSE is significantly higher and the correlation slightly lower. The high RMSE can be attributed to the sudden changes in respiratory rate, which occured during the transitions between the different respiration patterns. Therefore, a small error in the time synchronization between the ground truth signal and our video signal resulted in a large absolute deviation. This issue is illustrated in fig. 4. Figure 4 also shows the excellent overall agreement between our algorithm and the ground truth. This visual impression is supported by the fact that the absolute error between our algorithm and the ground truth was less than 2 breaths per minute in 99.6% of the recording time for the first subject and 1% for the second subject. The transition-segments between the different respiration patterns have been excluded for this analysis, because the deviations are caused by an imperfect synchronization with ground truth and therefore cannot be attributed to our algorithms. The Bland-Altman plot of both subjects for the

4 X. YU, C. B. PEREIRA, Robust Remote Measurement of Respiratory Rate Using Infrared Thermography Respiration [a.u.] Resp. rate [min -1 ].8.6.4.2 4 2 Algorithm result Ground Truth 1 2 3 4 5 6 7 Time [s] Fig.5. Top: Raw respiration signal from one single grid cell (highlighted in fig. 3). Bottom: Comparison between respiratory rate (all cells) calculated with our algorithm and ground truth for the second subject. Areas with a high change in respiratory rate and small difference in time synchronization, which cause large deviations, are highlighted in grey. second sequence is shown in fig. 6. Compared to the first sequence, the bias is larger (.71 min 1 ), as well as the limits of agreement (-7.47-8.91). However, this was expected due to the larger range of respiratory rates. Moreover, areas with large deviations from ground truth are highlighted. While the areas marked in grey depict the transition between respiration and apnea, the area highlighted in yellow represents the transition from tachypnea to eupnea at the end of the sequence (also see fig. 4). The Bland-Altman plot in combination with fig. 4 shows that the rather large RMSE is only caused by errors in time synchronzation between the video signal and ground truth. In conclusion, the performance of our method even during various respiratory rates and respiration patterns is excellent. Differences [min -1 ] 4 2-2 1 2 3 4 Fig. 6. Mean values [min -1 ] Joint Bland-Altman plot of both subjects for the second sequence. Areas with large deviations from ground truth due to differences in time synchronization are highlighted. 5. Discussion and Outlook In this paper, we presented a novel approach for unobtrusive respiratory rate monitoring. Our approach serves the increasing demand and need for new contactless and unobtrusive vital sign monitoring solutions. In contrast to other proposed methods, our algorithm does not rely on the identification and tracking of (anatomic) feature points such as the nose. Instead, respiration is detected across the whole thermal image using a grid. With this measure, our approach is more widely applicable, e.g. if the nose is outside the camera s field of view. Moreover, our method is fully automatic and does not require any user interaction. Since our algorithm was only evaluated in a preliminary study with two subjects, we are planning a larger clinical study to obtain more data for a more detailed validation. Although all algorithms are causal and thus real-time capable, our current implementation s performance is rather slow. Additional efficiency improvements in the code are needed to ensure actual real-time capability. Finally, we are investigating the influence of background noise on the algorithms and means to further reduce requirements on image quality and preprocessing steps. Acknowledgements Research described in the paper was supervised by Prof. S. Leonhardt and Prof. V. Blazek, RWTH Aachen University, Germany. Carina Barbosa Pereira wishes to acknowledge FCT (Foundation for Science and Technology in Portugal) for her PhD grant SFRH / BD / 84357 / 212.

POSTER 216, PRAGUE MAY 24 5 References [1] GUYTON, A. C. ; HALL, J. E. Textbook of Medical Physiology 11th ed. Elsevier Saunders, 26. [2] ZHANG, Q., XU, G.Q., WANG, M., ZHOU, Y., FENG, W. Webcam based non-contact real-time monitoring for the physiological parameters of drivers. In IEEE 4th Annual International Conference on Cyber Technology in Automation, Control, and Intelligent Systems (CYBER). Hong Kong (China), 214, p. 648652. [3] LI, M.H., YADOLLAHI, A., TAATI, B. A non-contact vision-based system for respiratory rate estimation. In 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). Chicago (IL, USA), 214, p. 21192122. [4] YANG, M., LIU, Q., TURNER, T., WU, Y. Vital sign estimation from passive thermal video. In IEEE Conference on Computer Vision and Pattern Recognition. Anchorage (AK, USA), 28, p. 1-8. [5] FEI, J., PAVLIDIS, I. Thermistor at a Distance: Unobtrusive Measurement of Breathing. In IEEE Transactions on Biomedical Engineering, 21, vol. 57 (21), no. 4, p. 988-998. [6] PEREIRA, C.B., YU, X., CZAPLIK, M., ROSSAINT, R., BLAZEK, V., LEONHARDT, S. Remote monitoring of breathing dynamics using infrared thermography. Biomedical Optics Express, 215, Vol. 6, no. 11, p. 4378-4394. [7] SHAO, D., YANG, Y., LIU, C. TSOW, F., YU, H., TAO, N. Noncontact Monitoring Breathing Pattern, Exhalation Flow Rate and Pulse Transit Time. IEEE Transactions on Biomedical Engineering, 214, vol. 61, no. 11, p. 276-2767. [8] OTSU, N. A Threshold Selection Method from Gray-Level Histograms. IEEE Transactions on Systems, Man, and Cybernetics, 1979, vol. 9, no. 1, p. 62-66. About Authors... Xinchi YU was born in Berlin, Germany. He studied Electrical Engineering at the RWTH Aachen University and received the M.Sc. degree in 215. He is now a Ph.D. student at the Philips Chair for Medical Information Technology, RWTH Aachen University, Aachen, Germany. His main research fields are geriatrics and unobtrusive vital signs monitoring. Carina PEREIRA was born in Braga, Portugal. She received the M.Sc. degree in Biomedical Engineering from the University of Minho, Braga, Portugal, in 211. Currently, she is working toward the doctor degree at the Philips Chair for Medical Information Technology, RWTH Aachen University, Aachen, Germany. Her research interests include infrared thermography, imaging and biosignal processing as well as feedback control in medicine.