APPLCATIONS OF POSITIVE PRESSURE VENTILATION DURING AIRPORT AND ARFF INCIDENTS. Leroy B. Coffman III, Tempest Technology Corporation, USA

Similar documents
Ultra-High Pressure Firefighting: The Fastest Attack

SMOKE CONTROL USING POSITIVE PRESSURE FANS

TACTICAL VENTILATION Graeme Bowser, Tyne & Wear Fire Brigade, U.K.

Dräger Swede Survival System Phase 1 Flashover Development Observation

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

Township of Cumru Fire Department 03/12/2008 Standard Operating Guidelines Page: 1 of 8 Section 15.05

Direct attack. 1 Introduction

Model SOP Standard Operating Procedure

DISCLAIMER TSS is simply providing current information so you can make sound tactical decisions.

Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

IFE Level 3 Diploma in Fire Science and Fire Safety

BASIC AIRCRAFT STRUCTURES

Chapter 5. Response Tactics and Strategies Delmar, Cengage Learning

CHESTERFIELD COUNTY FIRE AND EMERGENCY MEDICAL SERVICES PROCEDURES

Tools, Techniques and Tactics (3T) in Combination for Firefighting

CLEARWATER FIRE AND RESCUE DEPARTMENT STANDARD OPERATING PROCEDURE APPROVED BY: EFFECTIVE DATE: 10/12/07 REVISION DATE:

Ventilation Practices and Evidence-Based Research. By: John Paul Jones, Fire Chief KCKFD

Kansas State University Fume Hood Operation

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Utilities Gas Emergencies Revised

Yakima County Fire District 12 Standard Operating Guidelines SOG 5-1 Hazardous Materials Operations

Examiner s Report March 2013

FIRE FIGHTER II JPR: FFII-1A

Introduction Volume & Area Based formulas Figure 1

LABORATORY FUME HOOD SPECIFICATION AND MAINTENANCE PROGRAM

PRINCIPLES OF FLIGHT

FROM THE CLASSICAL FIRE FIGHTING WATER SUPPLY TO STRUCTURE AND SMOKE GAS COOLING TAKING GLEINALMTUNNEL AS AN EXAMPLE; PART II

Design Requirements for Eyewash and Safety Shower Units

Idaho Fire Service Technology Fire Fighter II

GEORGIA FIREFIGHTER STANDARDS AND TRAINING AIRPORT FIREFIGHTER PERFORMANCE EVALUATION & INSTRUCTIONS SHEET

Presenter s Notes. Before darkening the room, offer a welcome and an overview. Begin by introducing the program and its topic:

rd Quarter Continuing Education Hazardous Materials Defensive Actions/ Emergency Decon

High-Rise Fireground Field Experiments Results

The term MAYDAY typically will be used in the following situations:

ATMOSPHERE AND PHYSIOLOGICAL REQUIREMENTS

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET

First Responder Beware

Preparing A Landing Zone L Z

Responding to Natural Gas Pipeline Emergencies

Center for National Response Operational Test Report for the Tempest Technology Corporation Mobile Ventilation Unit (MVU)

Transportation Emergency Preparedness Program (TEPP) Model First Responder Procedure for Transportation Accidents Involving Radiological Materials

Vision Painting Inc Safety Management System

SITUATIONAL AWARENESS, DISORIENTATION and IMPROVING FIREFIGHTER SURVIVAL AT STRUCTURAL FIRES

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 8 Search and Rescue Basics Revised

Skill Sheet 17-I-2. Attack a structure fire above, below, and at ground level Interior attack. (NFPA 1001, , )

second test was conducted using at 3/4inch nozzle to determine a practical maximum pressure for the pump.

Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios

CONSIDERATION OF DENSITY VARIATIONS IN THE DESIGN OF A VENTILATION SYSTEM FOR ROAD TUNNELS

PERFORMANCE CRITERIA AND INSTRUCTIONS

VOLUSIA COUNTY FIRE CHIEFS ASSOCIATION MODEL OPERATING PROCEDURE

EMERGENCY EQUIPMENT Table of Contents CHAPTER 8 - EMERGENCY EQUIPMENT

VENTILATION DURING TUNNEL CONSTRUCTION INDUSTRY CONSIDERATIONS

===============================================================

Fire Apparatus Operator: ARFF

TABLE OF CONTENTS PART 2 - CONFINED SPACES

Fire Apparatus Operator Aircraft Rescue and Fire Fighting

Ballistics and Trajectory

Airborne Activity Sampling and Monitoring at Hinkley Point A Site. David Williams, Hinkley Point A Site

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

The Fly Higher Tutorial IV

EFFECTS OF WATER SPRAYS AND SCRUBBER EXHAUST ON FACE METHANE CONCENTRATIONS

Emergency Water Injection /28/2017 updated 07/21/2017

BASIC FIRE SCHOOL VENTILATION, SALVAGE & OVERHAUL

HAZARDOUS MATERIALS SOGS

West Metro Fire Protection District

CALIFORNIA STATE RAILROAD MUSEUM

CLEARWATER FIRE ACADEMY

Galva Fire Department SOP

CTG Certification Protocol -- Version 3.0 SUMMARY

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

LABORATORY SAFETY SERIES: Laboratory Hoods

Emergency Response Plans

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

FIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU

The process of measuring air

"LABORATORY SAFETY SERIES"

Fuselage, Wings and Stabilising Surfaces

CLEARWATER FIRE ACADEMY

2017 Volunteer Week - Course Descriptions

The primary purpose of laboratory fume hoods is to keep toxic or irritating vapors out of the general laboratory working area.

Title: Abrasive Blasting Effective Date: 11/17/2014 Control Number: THG_0034 Revision Number: 1 Date: 10/22/2015 Annual Review Completed: 5/13/2015

Escape and Rescue From Submerged Vehicles

Pipe-Away Pressure Vacuum Vent /Conservation Vent

FAR AIR TAXI Emergency Crewmember Training

SCENARIO 18 Leak on Intermodal Pressure Tank Container

INSTRUCTOR GUIDE TOPIC: STOPPING UNSAFE PRACTICES LEVEL OF INSTRUCTION: TIME REQUIRED: THREE HOURS MATERIALS: APPROPRIATE AUDIO-VISUAL MATERIALS

SAFETY MANAGEMENT MANUAL Confined Space Entry

SAFETY AND HEALTH IN THE USE OF CHEMICALS AT WORK

RFFS Procedures. Airside Operational Instruction 18. Content

FIRE CHIEF S ASSOCIATION OF BROWARD COUNTY

The purpose of this policy is to provide operational guidelines for San Diego County Fire Departments (FD) responses to natural gas incidents.

Chapter 1 FF I Orientation and Fire Service History

Enabling Objectives (EO): EO Identify certain practices that could be considered unsafe and result in injury or death.

Amendment: To Return a portion of a Report in the form of an Identifiable Part of Proposal and related Comment 130-1

Autumn 2018 Firefighter 1

Ballistics and Trajectory

OPITO Helideck Standards Training Facility & Equipment Technical Specification

TESTING SKILLS PORTABLE FIRE EXTINGUISHERS

Guidelines for Rapid Extraction in a Hazardous Materials Environment

Appendix FRANCE Annecy Tunnel Courier

FALL PROTECTION GUIDELINE

Transcription:

APPLCATIONS OF POSITIVE PRESSURE VENTILATION DURING AIRPORT AND ARFF INCIDENTS Leroy B. Coffman III, Tempest Technology Corporation, USA ABSTRACT Positive Pressure Ventilation (PPV) is the use of high-powered blowers to remove the hostile interior environment of an enclosed structure. Its purpose is to increase safety for fire fighters and rescue personnel, enhance the speed of fire fighting and rescue operations, and lessen property damage caused by smoke, heat, and fire. Over the past fifteen years, PPV has been proven effective for ventilating residential structures, high-rise buildings and even tunnels. Recently, new applications for PPV have been discovered for airport fire fighting operations involving aircraft, passenger terminals, hotels and other large structures. INTRODUCTION to PPV Positive Pressure Ventilation, or PPV as it is commonly known, is a fire fighting technique that uses air as a tool to control the hostile environment inside an enclosed structure. Specially designed blowers are used to replace the interior environment with fresh, ambient air. PPV was first developed in the United States in the 1960 s and was used on a limited basis by progressive fire departments. In the early 1990 s, information about the use and applications of PPV became widely available and research was conducted to study the benefits it offered to fire fighters. Today, PPV is an accepted fire fighting technique used by fire departments and fire brigades around the world. PPV works on the principle that air flows from high pressure to low pressure. Ventilation is accomplished by positioning a ducted fan on the outside of the structure, blowing inward, so that the cone shaped air pattern created by the fan seals the entrance opening and forces air into the structure. Once this seal is achieved, the air pressure increases equally at all points. To remove the contaminants, an exhaust opening is created near the seat of the fire. The exhaust opening releases the air pressure and all of the contaminants are drawn towards this point of low pressure. Because the positive pressure is equal at all points inside the structure, contaminants are drawn from the ceiling, floor, and around obstructions. PPV benefits fire fighting personnel by creating a safer environment inside an enclosed structure. The removal of smoke makes it easier for them to find victims and the location of the fire. The removal of heat allows them to move more freely

within the structure. Removal of hot gases reduces the possibility of flashover. Ultimately, PPV benefits victims by increasing their chances of survival. PPV EQUIPMENT The most common PPV blowers range in size from 18-27 inches (460-690mm) in diameter and deliver from 7,000-23,000 CFM (11,900 m 3 /hr to 40,600 m 3 /hr) airflow. They are gasoline or electric powered and are carried on the fire-fighting vehicle. Blowers of this size can effectively ventilate structures up to 6,000 square feet (560 square meters). To be effective for PPV, a blower must be able to create a high level of pressure and produce a cone shaped air pattern. This is achieved through the use of an impeller with multiple blades and a duct or shroud to enclose it. The blower must also feature a tilt mechanism for adjusting the air cone to seal the entrance opening. To apply PPV to large structures such as high-rise buildings, road tunnels, and passenger terminals, larger ventilation tools have been developed. Called mobile ventilation units (MVU), these truck or trailer mounted blowers produce airflows from 80,000-200,000 CFM (135,000 m 3 /hr to 272,000 m 3 /hr) and generate air velocities of up to 78 MPH (34 m/s). Similar to the tilt mechanism on smaller PPV blowers, mobile ventilation units feature a means of adjusting the air cone to seal the entrance opening. This is accomplished through the use of a hydraulic control system to adjust the fan height, pitch, and direction. The ability to precisely adjust the air pattern is critical for effective PPV operations with a mobile ventilation unit. PPV AND AIRPORT FIRE FIGHTING The versatility of PPV as a fire fighting tool makes it ideally suited to protection of the various structures at airport facilities. With the right equipment and proper training, PPV can be used to ventilate aircraft, passenger terminals, hangars, airport hotels, and parking structures. PPV and Aircraft Fire Fighting One of the first tests of PPV for aircraft fire fighting was conducted by the fire department at Holmstead Air Force Base in Florida. The purpose of this test was to determine the potential benefits of using PPV on cargo and passenger aircraft fires. Small, portable PPV units were used for these tests. Their tests produced the following conclusions about the benefits of PPV and how it should and should not be applied:

To work effectively, the aircraft interior must be closed to allow pressurization by the blower. With too many openings, the blower is not capable of increasing the air pressure inside the cabin. PPV is not effective on aircraft crashes or ground fire situations in which ventilation has occurred before fire-fighters have arrived (i.e. doors, hatches, windows are opened, fuselage is broken open or split). This prevents pressurization and allows uncontrolled leaks. It is not effective to attempt to close openings after arrival. Interior fog nozzles or large hand lines are more effective using push/pull techniques. PPV applied to the center of the aircraft fuselage such as over-wing hatches or belly hatches will work but is not as effective as front-to-rear or rear-to-front ventilation. The best scenario is to have the exhaust opening as close to the seat of the fire as possible. When PPV is applied, smoke and heat quickly rise to the upper half of the interior and move toward the discharge openings thereby improving visibility and reducing toxicity and heat in the lower half of the cabin within 20 to 30 seconds. The angle of the air cone covering the opening is not critical. It can be from a vertical, horizontal, or varying degree of angle. A flat opening can also be sealed by the PPV cone. Tactical Ventilation Trials at the Fire Service College, July 28, 1998 Tests on a 737 aircraft fire simulator were conducted during a series of PPV trails at the Fire Service College in Moreton-in-Marsh, England. The objective of the tests was to compare the effects of natural ventilation to the effects of PPV during an aircraft fire fighting operation. As explained in the report, the 737 had four exits, two at the front and two at the rear. The fire crib was situated approximately ¾ of the way down the fuselage towards the front of the aircraft. The fire load consisted of a single crib containing eight pallets, one bale of straw and a small quantity of diesel fuel. The first test using natural ventilation resulted in zero visibility within six minutes. When water was applied, the interior became very hot due to steam. Even after the fire was extinguished and the crew had exited the aircraft, visibility above the seat level was nil. During the second test, visibility was reported to be good during the entire operation. Even when water was applied, the fire fighting crew maintained full visibility and the steam was moving away from them due to PPV.

The final conclusions of the Moreton PPV trials were that PPV resulted in quicker extinguishment of the fire due to greater visibility, less heat and water damage, enhanced firefighter safety, and an improved working environment. PPV and Large Frame Aircraft Large frame aircraft can be difficult to ventilate with small PPV blowers. Their large cubic volume can be too great for the blower to quickly ventilate and their access openings are too far above ground to seal with the air cone. It most cases, it is not practical to position a small blower on the wing of an aircraft or on the roof of a fire fighting vehicle. Because of their high airflow output and elevating capabilities, mobile ventilation units have the potential to dramatically increase an ARFF team s ability to control the environment inside a large frame aircraft. In May of 2001, tests of the capabilities of the MVU for aircraft ventilation were conducted with the fire department at the Ontario International Airport in Southern California. For these tests, a stair truck was positioned against the front passenger door and the MVU was positioned approximately thirty feet from the doorway. There was a cross wind of 15-20 mph which did not pose any problems. The rear cargo door of the jet was used as the exhaust opening. Electric smoke generators were run inside the cargo hold until zero visibility was achieved. A number of evolutions were performed to measure the speed with which the MVU could clear the cargo hold of smoke. The best time was 40 seconds to have good visibility from nose to tail and two minutes to completely clear the cargo hold with no residual smoke visible. These tests proved that PPV can be used to quickly clear a 747cargo jet of smoke, heat, and gases. In a matter of minutes, there was clear visibility, which would make it easier for fire fighters to locate the seat of the fire and initiate search and rescue operations. The fact that the MVU can be located up to thirty feet from the entrance opening ensures access for fire and rescue personnel. Passenger Terminals Disruptions of passenger service can be very costly to airlines. Even a small fire in a trash bin or moving walkway can cause an entire terminal to be shut down. Fixed ventilation systems and smaller PPV blowers can take hours to remove the smoke. A mobile ventilation unit applying PPV can remove smoke or fumes in a fraction of the time and get the terminal back in operation much faster.

A Real Life Example: On June 29, 1999, an early-morning fire under an automatic walkway at O'Hare International Airport forced the evacuation of one terminal and disrupted flights until the following day. The blaze broke out just after 4:15 a.m. in the corridor connecting Concourses B and C in O'Hare's Terminal 1, which houses United Airlines. Investigators from the Fire Department later concluded that the blaze originated in the bearings under the moving sidewalk. Burning rubber on the walkway quickly filled the tunnel with dark, acrid smoke and about 100 people, mostly employees, were evacuated from the terminal by police around 4:30 a.m. As a result of the blaze, 53 departures and 37 arriving flights were delayed an average of 45 minutes. Eighteen flights were canceled. Some delays were as long as two hours. Testing Data: In July of 2001, tests were conducted in a passenger terminal at the Dallas Ft. Worth International Airport. For this test, a portion of Passenger Terminal B was filled with cold smoke. A mobile ventilation unit was positioned on the tarmac and a passenger jet way in the middle of the terminal was used as the entrance opening. A jet way at the end of the terminal was used as the exhaust opening. After starting Positive Pressure Ventilation with the MVU, it took only ten minutes for the terminal building to become pressurized as the smoke could be seen moving towards the exhaust opening. After 20 minutes, the smoke began to clear and visibility improved significantly. After 38 minutes, the terminal was completely cleared of smoke. A similar emergency involving fumes and odors previously occurred in the same terminal, and had taken four hours to ventilate. The estimated cost to the airline of the terminal closure was $80,000 per gate, per hour (ten gate-hours total). PPV and Fixed Emergency Ventilation Systems Many passenger terminals have fixed ventilation systems designed to control the movement of smoke during a fire. PPV is not intended to replace a fixed ventilation system. It is recommended as an alternative or supplement to an existing ventilation system. PPV can be applied in the following situations: 1. When a terminal does not have a fixed ventilation system in place. There are many terminals with no emergency ventilation system installed. The technology was either not available at the time the terminal was built or it was deemed unnecessary by the people who designed it.

2. When the fixed ventilation system in a terminal is not operational. A fixed emergency ventilation system is designed to withstand the extreme conditions that exist inside a terminal during a fire. However, there are limitations to the length of time that it will continue to function in this environment. In the event that a fixed system fails due to prolonged exposure to extreme heat, an MVU is capable of providing ventilation. 3. To supplement and enhance a fixed ventilation system. In some cases, a terminal ventilation system may not be effective for controlling heat and smoke from a fire. The smoke may be in a location that can not be controlled with a fixed system. In these cases, an MVU can be an effective supplement to this system. Hotels and Other Large Structures In addition to aircraft and terminal incidents, a mobile ventilation unit can be used to ventilate other large structures found at airport facilities. High-rise hotels, aircraft hangars, underground tunnels, and parking structures can all be ventilated with PPV. The Hyatt Regency West Hotel at the Dallas Fort Worth International Airport is a typical airport hotel. It has twelve floors, a large below-ground ballroom, and a large lobby area. In July 2001, Tempest Technology worked with the Dallas Forth Worth International Airport fire department to test the MVU in the Hyatt Regency. Two simulations were performed. For the first scenario, the below-ground ballroom was filled with cold smoke. The MVU was positioned near the rear entrance of the hotel, and a standard man-door was used as the exit point. Once ventilation was started, visibility improved significantly after only two minutes. After ten minutes, the ballroom was completely cleared of smoke. The second scenario was a test of the MVU s ability to ventilate the upper floors of a hotel while keeping the stairwell clear for victims and rescue personnel. For this test, the entire tenth floor of the hotel was filled with cold smoke. Using the emergency exit stairwell to direct the airflow, the MVU was positioned at ground level, blowing through the main entrance. The doors in the lobby and on the tenth floor were opened to create an exhaust opening. It took only five minutes to completely clear the tenth floor of smoke. MVU Misting System and Mass Decontamination In the event of a chemical attack, personnel and property must be decontaminated using water and a neutralizing agent. When large numbers of people are involved, setting up a mass decontamination system can be complicated and time consuming. The misting system of the MVU has shown potential as a fast and effective mass decontamination tool.

By introducing water into the air stream of the blower, a fine mist can be distributed over a large area with enough velocity to effectively wash down contaminated people, vehicles, and equipment. Because the amount of water flowing through the misting system is only 80 gallons per minute (288 lpm), the amount of waste water can be reduced. The mist can also be used to cool the air during PPV operations and knock down suspended gases. Breaking the water down to a very small droplet size increases the surface area, improving the heat absorption properties of a given amount of water. Water flow averaging only about 275 liters per minute can absorb up to 20,000 kj of heat per second. CONCLUSIONS Positive Pressure Ventilation is a fire fighting tool that offers many benefits to ARFF departments. With the development of larger ventilation tools such as the MVU, PPV can be applied to large structures in ways that were impossible before. As with the development of techniques for the application of PPV for structural fire fighting, fire departments need to share their knowledge and research to develop standards for PPV implementation during ARFF incidents. 1. PPV is a proven ventilation technique that offers clear benefits for fire and rescue personnel when fighting fires at airport facilities. The large structures common at airport facilities can be difficult to ventilate, increasing the risks for fire and rescue personnel. The application of PPV can quickly and effectively reduce heat, improve, visibility, and create a safer environment for fire and rescue personnel. There are also clear benefits to victims. 2. The mobile ventilation unit is an effective tool for applying PPV during airport fires. It is designed specifically for large structure ventilation. Because the MVU can be elevated, it is capable of ventilating large frame aircraft, passenger terminals and hotels. 3. Further research and testing are required to develop operational and tactical guidelines for fire and rescue personnel to follow. As with any fire fighting tool, training and coordination of personnel are important for safe and effective operations.

References: Positive Pressure Ventilation in Aircraft Fires, Marty Jester, Chief, Holmstead AFB Fire Department 1989. FIRE IN MOVING WALKWAY DISRUPTS O'HARE FLIGHTS Chicago Tribune; Chicago, Ill.; Jun 29, 1999; Evan Osnos, Tribune Staff Writer; Report of Tactical Ventilation Trials at the Fire Service College, Moreton-in-Marsh, 27th-31st July 1998. Report compiled by: Stn O Bowser, Stn O Turpin, Sub O Sproat