BAYARD is a company of. Hydraulic control valve Hydrobloc system

Similar documents
Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level.

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING

VALVES HIDROMATIC VALVE.

DN300 DN2000 C Plunger Valve

MWEA MAINTENANCE SEMINAR SPECIALTY VALVES POWER GLOBES

my SYSTEM A guide to common applications in water distribution systems

WW-730. Pressure Sustaining/Relief Control Valve

Ø248 Ø Series. R 2.00 R 2 Hydraulic Control Valves R 3 R 6 SEE "SEAT DE T DETAIL NO. 2" CONTROL VALVES

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

RESIDENTIAL REGULATORS

WW-720. Pressure Reducing Control Valve

BERMAD Fire Protection Hydraulic Control Valves

SINGLE VALVE WITH LOW-FLOW BYPASS

Rate of Flow Valve Series 120

Models 106-RF / 206-RF Rate of Flow Control Valve

BEFORE SALES AFTER SALES

Bermad Pressure Reducing. Model: 42T

Pressure and Flow Control Valves DBGM, German and European Patents

WW-720. Pressure Reducing Control Valve

Installation and operation Manual. Bermad Surge Anticipation Valve. Model No 435

CSO/STORMWATER MANAGEMENT. HYDROVEX HHV-E Vortex Driven Regulator

TECHNICAL DATA Q= C. Table 1 - Specifications

Bringing Pressure Under Control: Harnessing Control Valves for Intelligent Water Networks. A Report on Best Practice from TALIS

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Norval Pressure Regulators

AVP-F. p setting range (bar) Code No. 003H6200

FITTINGS AND VALVES Düker Plunger Valve RKV Type 7015 Professional control of flow rates, reservoir levels and pressures Safe, hygienic and durable!

SINGER MODEL 106/206-RPS-L&H

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

CAST IRON SAFETY VALVE TYPE 6301

Dival 600. Pressure Regulators

300 Series. Automatic Hydraulic Control Valves

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

THE INFLOW OF UNWANTED AIR

HYDRAULIC CONTROL VALVES

TECHNICAL DATA. Table 1 - Specifications

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

V311. Venta. Three-way Plug Valve, Flanged PN 16

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

High Performance BSP Dial Up Pattern Pressure Reducing Valve

Integral type Differential pressure flowmeter VNT Series

Technote. Frese ALPHA cartridges. Application. Features. Benefits.

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

FILTER BYPASS CONTROL

Pressure Reducing Valve for Steam Type 2333 A

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Actuator HON 670 / 671

Pressure independent control valve (PICV) FLOWMATIC

P r o d u c t R a n g e Data sheet: P

Aperval Pressure Regulators

Wet pipe low flow foam/water system

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

3-Way Safety Block DSV

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Leak free Pipe Rupture Valve for Excavators

Gas Pressure Regulator HON 200

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidMoon Self-Adjusting Knife-Gate Regulator

Engineering / Technical Section

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread

3776B FLANGED PRESSURE INDEPENDENT CONTROL VALVE (P.I.C.V.) PN 16 TECHNICAL DATA SHEET. Main features:

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

Pressure Independent Control Series

The Future of Hydraulic Control in Water-Systems

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

Materials : Stainless steel ASTM A351 CF8M

Pressure reduction controller (PN 16, 25, 40)

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

PRESSURE REDUCING VALVE RP45 (EN)

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

Pressure reducing valves Index

Pre-adjustable pressure reducing valves with self-contained cartridge

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB

BERMAD Irrigation. Automatic Metering Valve (AMV) 900-D Series. Basic Valve ??????? IR-900-D.

CASH VALVE TYPE KP BACK PRESSURE VALVES

PRESSURE REGULATORS. Type A/140. Process Management TM

Installation, commissioning and servicing instructions

Installation, operation & maintenance manual - original version

Gas Pressure Regulator R 51

BERMAD Irrigation. IR-100 hyflow Basic Valve. Basic Valve.

Two-port valves, male threaded, PN25

Gas Pressure Regulator HON 502

Norval Pressure regulator

Gas Pressure Regulator HON 300

2 - way valve for steam, pressure relieved (PN 25) VGS - external thread

Safety Relief Valve HON 832

PRESSURE REGULATORS. Type B/240. Process Management TM

6301 TYPE CAST IRON SAFETY VALVES

Full-Vacuum Chlorinator C 2212 MB / 1

Gas Filters DN15 DN300. elektrogas.com EE151 06/13

RELIEF VALVES. Type VS- FL. Process Management TM

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Model: 43T. Bermad Pressure Relief Valve

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

Transcription:

BAYARD is a company of Hydraulic control valve Hydrobloc system

Hydrobloc control valve 1 - Technical data Range: - DN 50 to 1000 for XGS design. - DN 50 to 800 for XG design. - DN 50 to 300 for XGA design PN 10, 16 or 25 (depending on functions). Maximum temperature: +1 C to +65 C. Seating: class A according to standard ISO 5208-2. XG and XGS designs: - Face-to-face dimensions according to standards EN 558-1 series 1 (except DN 1000) and ISO 5752 series 1 (except DN 1000). XGA design: - Face-to-face dimensions according to standard ISO 5752 series 8 (except DN 300). Flange drilling according to standards EN 1092-2 and ISO 7005-2: ISO PN10, 16 or 25 for DN 50 to 1000 (other drillings on request). Fluid: drinking water or 2 mm filtered untraited water. 2 - Characteristics and performances How to choose the design: - Bayard range offers two different versions: XG and XGS design. - The decision which design to take depends on the required application and on the pressure and flow rate conditions. - The XGS design specially fits for a pressure reducing application and when there is a risk of cavitation. - The XG design suits better for low head loss conditions. Globe pattern. Single chamber. XGS design. Globe pattern. Single chamber. XG design. Globe pattern. Double chamber. XG design. Angle pattern. Single chamber. XGA design. Recommended velocity (VE) XGS design m/s XG design m/s Permanent maxi velocity 4 5 Exceptional maxi velocity 6 7 For a surge anticipating valve: higher maxi velocities might be acceptable, please consult us. Mechanical resistance: - Main valve PN25 in standard version (PN40, please consult us). - Pilot circuit PN10, PN16 or 25 according to the expected applications. (Other possibilities please consult us). Control accuracy: Control accuracy is guaranteed by: - The pilot system principle. - The linearity between the open section freed by the movements of the mobile unit and its stroke. In the mentioned operating range, the accuracy for pressure control is more or less 5% (other functions: see dedicated data sheet.) 2 Bayard APXA12001 - January, 2012

Hydrobloc control valve 3 - Hydraulic characteristics Head loss curves for fully open valve XGS design 10 9 8 7 Head loss in m WH Head loss in m WH 6 5 4 3 2 1 0 XG design 10 9 8 7 6 5 4 3 2 DN 50 DN 65 DN 50 DN 80 DN 100 DN 65 DN 80 DN 125 DN 100 DN 150 DN 125 DN 150 DN 200 DN 250 DN 200 DN 250 DN 300 DN 350 1 10 100 1000 10000 DN 300 DN 400 DN 500 DN 400 DN 600 DN 700 DN 600 DN 900 DN 800 DN 1000 Flow rate in l/s Flow rate factor (Kv) DN XGS design XG design Kv Kv 50 30 48 65 50 67 80 69 102 100 103 172 125 169 243 150 181 339 200 436 688 250 608 978 300 1012 1443 350 1389-400 1413 3168 500 3147-600 3172 5821 700 5626-800 - 9134 900 9184-1000 9233-1 0 1 10 100 1000 10000 Flow rate in l/s Curves and data established for water at 20 C for standard valve mounted on horizontal pipe. Kv: (flow rate factor) is the flow rate at 20 C expressed in m 3 /h which generates a head loss of 1 bar inside the valve. How to choose the diameter The diameter of the valve must be chosen according to the flow rate conditions and the pressure on the valves. Generally two cases are to be considered: Case 1: The head loss of the valve has to be as low as possible (2 to 5 according to the DN and design) because the available head loss or the static pressure are 1 bar. Case 2: The available head loss is high, so higher velocities can be admitted (beforehand, check that the available head loss is higher than the head loss through the fully open valve at the maximum considered flow rate). Recommended flow rates (l/s) VE*/ DN 50 65 80 100 125 150 200 250 300 350 400 500 600 700 800 900 1000 XGS Design Case 1 Mini flow rate 0.2 0.4 0.7 1 16 2.5 3.5 6.3 9.8 14 19 25 39 57 77-127 157 Maxi permanent flow rate 2 3.9 6.6 10.4 16 25 35 63 98 141 192 251 393 565 770-1272 1571 Case 2 Mini flow rate 0.4 0.8 1.3 2 3.1 4.9 7.1 13 20 28 38 50 79 113 154-254 314 Maxi permanent flow rate 4 7.8 13.6 20 31.2 49 71 126 196 283 385 503 785 1131 1539-2545 3142 XG Design Case 1 Mini flow rate 0.2 0.4 0.7 1 1.6 2.5 3.5 6.3 9.8 14-25 - 57-101 - - Maxi permanent flow rate 2.5 4.9 8.3 13 20 31 44 79 123 177-314 - 707-1257 - - Case 2 Mini flow rate 0.4 0.8 1.3 2 3.1 4.9 7.1 13 20 28-50 - 113-201 - - Maxi permanent flow rate 5 9.8 17 25 39 61 88 157 245 353-628 - 1414-2513 - - * VE (m/s) = Equivalent velocity: average velocity in the inlet section (DN) These values don t apply to flow limiting, overspeed and differential functions. Bayard APXA12001 - January, 2012 3

Hydrobloc control valve XGS and XG: Globe pattern main valve ø B Double chamber (XG design)* C Single chamber D H A XGS design XG design DN A** B C D Weigh*** B C D H Weigh*** Weigh*** mini mini Single chamber Double chamber mm mm mm mm kg mm mm mm mm kg kg 50 230 145 195 80 10.2 173 238 84.5-12.1-65 290 173 230 95 15 198 257 94.5 83 16.6 26.0 80 310 198 250 102 19.8 226 277 102 82 20.4 31.5 100 350 226 270 120 27.1 265 302 120 91 32.2 46.5 125 400 226 290 138 38.5 307 396 137 103.5 40.5 60.9 150 480 226 290 153 45.7 351 443 152 100 64.9 94.8 200 600 351 443 182 78.8 436 567 182 117 115 146.4 250 730 436 580 212 132.7 524 609 212 125 153.5 219.6 300 850 524 631 242 192.1 606 657 242 125 217.1 295.3 350 980 606 657 278 247.4 - - - - - - 400 1100 606 657 312 268.4 835 847 355 194.5 481 714 500 1250 835 847 367 540 - - - - - - 600 1450 835 847 422.5 708 1085 1229 422.5-1205 - 700 1650 1085 1229 480 1415 - - - - - - 800 1850 - - - - 1355 1407 512.5 2050-900 2050 1355 1407 562.5 2322 - - - - - - 1000 - - Consult us - - - - - - - C mini: visual position indicator. C maxi: with SCADA position transmitter option (with limit switch option up from DN 800). On some valves, the pilot circuit can be larger than the overall dimensions of the main valve. XGA: Angle pattern main valve * XGS design for double chamber, please consult us. ** For flow limiting or overspeed application see dedicated technical data sheet for face-to-face dimensions. *** Weight for main valves only. ø B A2 C Single chamber H Double chamber A1 DN A1 A2 B C mini. H Weight* Weight* mm mm mm mm mm Single chamber kg Double chamber kg 50 XGA 125 125 173 212-11.6-65 XGA 145 145 198 232 83 15.4 27.1 80 XGA 155 155 226 244 82 19.2 33.6 100 XGA 175 175 265 264 91 31.1 45.1 150 XGA 225 225 351 380 100 69.4 99.6 200 XGA 275 275 436 480 117 103.5 135.2 250 XGA 325 325 524 529 125 143.7 209.8 300 XGA 400 300 606 571 125 241.1 319.6 * Weight for main valves only. 4 Bayard APXA12001 - January, 2012

Some examples... of the most common associated functions Hydrostab pressure reducing valve Serie K1 10 Small air valve kit ITR KV007 Limit switch ITR KV008 Time - based electric control - ITR KE027 Electric control ITR KE010 Non-return function ITR ITR KH016 Small air valve kit ITR KV007 Electric control ITR KE010 Non-return function ITR KH016 Twin filter circuit ITR KH002 Upstream-downstream function ITR KH007 + KH012 Altitude function ITR KH010 Motorised pilot ITR KE016 Automatically reduces a higher upstream pressure to a steady lower downstream pressure regardless of variations of flow and/or of upstream pressure. Standard spring P = 1 to 20 bar Other P = 0.2 to 2 bar P = 15 to 25 bar (limited to 300XG and 400XGS) Other values, consult us. Other PN, consult us. Hydrostab pressure sustaining / relief valve Serie K1 20 Maintains a minimum upstream pressure, by either sustaining or relieving excess pressure to the downstream side. Standard spring P = 1 to 20 bar. Other P = 0.2 to 2 bar. P = 15 to 25 bar (limited to 300XG and 400XGS). Other values, consult us. Other PN, consult us. Hydrostab pressure reducing / sustaining valve - Serie K1 50 Sustains a minimum upstream pressure and reduces the downstream pressure to a constant lower value. Standard spring P = 1 to 20 bar. Other P = 0.2 to 2 bar. P = 15 to 25 bar (limited to 300XG and 400XGS) Other values, consult us. Other PN, consult us. Hydro flow rate limiting valve Serie K2 10 Limits the flow rate to a preset value regardless of upstream and downstream pressures. VE = 1 to 2.5 m/s (standard) VE = 2 to 4 m/s Maximum differential pressure: 10 bar. Special requirements Extremely low and high p, please consult us. Hydro-savy float valve Serie K3 20 Pilot frost protection ITR KH037 Savy upstream pressure sustaining (K370) + frost protection ITR KH038 Upstream pressure sustaining ITR KH007 Upstream overpressure relief ITR KH006 2-level altitude ITR KH029 Upstream pressure sustaining ITR KH008 PN16 protection by downstream pilot ITR KH014 Upstream overpressure relief ITR KH006 Closes at top level and fully re-opens at lower adjustable level, allowing water renewal in the reservoir (float pilot located in the reservoir). Savy flow limiting (K380) + frost protection ITR KH039 Options Air valve kit for pilot circuit. Frost protection. Pressure relief (in case of upstream water hammer). Manual control for closing. Hydro altitude valve Serie K3 10 Closing at a constant and adjustable top level. Balances the inlet flow rate and the outlet flow rate till approximately 0.40 or 0.50 m below the top level. Standard H=1.5 to 8 m. Others H= 6 to 30 m (others values, consult us). H : altitude difference between the pilot and the closing level. Hydro-vega float valve Serie K3 40 Closes at a constant top level (float pilot located in the reservoir). A ccording to the location of the pilot valve in the reservoir. Options PN 16. PN 25 with pilot protection. Bayard APXA12001 - January, 2012 5

Your Choice in Waterflow Control TALIS is always the number one choice whenever water transport or control is required. TALIS has the best solution for water and energy management, as well as for industry and municipal applications. With a varied range of $ISTRIBUTION D EAU "ARRAGES 4RAITEMENT DE L EAU 3TOCKAGE EAU POTABLE )RRIGATION )NDUSTRIE!SSAINISSEMENT 'AZ hydrants to butterfly valves. From the knife-gate valves to the needle valves. Our experience, innovative technology, global expertise and 3TATIONS DE POMPAGE individual consultation process form the basis for developing sustainable solutions for the efficient handling of the vital resource water. BAYARD ZI - 4 avenue Lionel Terray BP 47 69881 Meyzieu cedex France Tél. + 33 (0)4 37 44 24 24 Fax + 33 (0)4 37 44 24 25 Site: www.bayard.fr E-mail: bayard@talis-group.com 6 Bayard APXA12001 - January, 2012 The technical data and performance can be modified without prior notice depending on the technical evolution. products we offer comprehensive solutions for the entire water cycle. From