multi-boost the EPS range of multi-boost water systems Owners Manual Installation Operation Maintenance demand special treatment

Similar documents
ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Airfix D-E-B Installation and operating instructions

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

C Lite CAD SERIES. ACS Approved. Patented CAD-2 diaphragm technology. Rugged copolymer polypropylene base. Quality brass air stem with o-ring seal

Operation and Maintenance manual Issue No: 1 Issue Date: 4th September 2007

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

New AQF Filter Polymer Filtration System

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

03/07/2014 V

Installation, Operating, Maintenance and Safety Instructions for MAXI-SYSTEM Pressurised water systems for boats

System Pressure Manager Standard & System Pressure Manager Plus

POOL BACKWASH SYSTEM. Installation manual. Proudly manufactured by

In Vessel Composter Installation & Commissioning Manual

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

Siphon vessel / Priming aid

Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual

Duplex Commercial Softeners

Dri-Line Mk3 Monnier Compressed Air Drain Trap

DECLARATION OF INCORPORATION

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

building the future Rainwater Harvesting System Installation and Operation Manual MDPE Systems PVC-UE Roofline, Window & Cladding Systems

REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE

Prestige Water Equipment Ltd.

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

The ultimate in water softening

Prestige Water Equipment Ltd.

OPERATION AND MAINTENANCE

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Water Hygiene Chlorination Water Treatment Legionella Control

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

MF2M Monnier Miniature Compressed Air Filter

6800 Maintenance Instruction System Flush Procedure

Quantum Contract Pressurisation Unit Operation & Maintenance Manual. Model: QC-35

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

Product Range. High performance and economic high pressure solutions Made in Germany

Vertex VP Operation and Maintenance

1020 Industrial Drive, Orlinda, TN fax

Installation, Operation & Maintenance Instructions

PUNE TECHTROL PVT LTD. Instruction and Maintenance Manual for Float and Tape Gauge FTG

Installation and commissioning instructions 255 series and 256 series

ROTAMAT Rotary Drum Fine Screen Ro 2 / RPPS

T EK-SUB 4800C 19 mm Submersible Level Transmitter

O&M Receiving and Inspection. Storage of Water Treatment Media

HUBER Rotary Drum Fine Screen ROTAMAT Ro2 / RPPS / STAR

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Installation and User Guide

Accu-Tab Systems 1000 Series by Axiall Corporation

Operating instruction

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

Variable Area Flow Meters

hth EASIFLO SYSTEM New Generation for 2015 Feeder specifications hth EASIFLO The perfect solution for treatment of commercial swimming pools

SPA WORLD. Pre- delivery Guide

Potable Water Truck Safe Work Procedure PTES_HSE_SWP_041. Name Date Signature. Author Geoff Selfe 25/01/2016. Reviewed Solomon Site 25/01/

80 Litre Suction Oil Drainer

Residential Pressure Booster Systems

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1

Manual Actuated Boiler Blowdown Valves

Installation, operating and maintenance Instructions for Seemag bypass level indicator

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

6900 Maintenance Instruction System Flush

You are now the proud new owner of an Alpine Swim Spa!

FLOW. State of the Art ELECTRONIC PUMPS CONTROLLERS. * Electronic starters. * Inverters. * Protection devices YOURWATER UNDER CONTROL

AutoChanger Installation & User Guide Issue 2

JET Mini Mechanical Pressurisation Equipment

FV Flash Vessel Installation and Maintenance Instructions

Summary of the MRA LPG Codes of Practice

Swimming Pool Winterizing

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

PRESSURISED PAINT CONTAINER

Accu-Tab Systems 2000 P Series by Axiall Corporation

Technical Service Bulletin March 2015 TSB142.01

Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry

OPERATING INSTRUCTIONS AND PARTS LIST FOR ELECTRIC VAPOURISERS TYPES ADCENG 200E/250E

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

ENERGY BLADE 3K4. Energy Blade Installation Instructions

Flamco Flamco-Fill STA Flamco-Fill STM

CUT OFF TOOL MODEL: CAT113

User's Manual. MixRite TF 10. Edition 05.08

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

1020 Industrial Drive, Orlinda, TN fax

Safety instructions and operating manual

Compact Transfer Pump

VORTEX REGULATOR Type WAB (UCY / CY-F / CE/V)

AUTOMATIC GAS MANIFOLDS

VERTICAL AIR COMPRESSORS

Reverse Osmosis System Installation Guide and Operation Manual.

OPERATION AND MAINTENANCE MANUAL

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

Chapter 10 SWIMMING POOLS

FLOWMETERING STORAGE TANKS FROM THE INSIDE

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

Transcription:

multi-boost the EPS range of multi-boost water systems Owners Manual Installation Operation Maintenance demand special treatment

Table of Contents Introduction... Health & Safety Health. Safety. Designs & Dimensions.. Delivery.. Offloading. Payment.... Scope of Supply.. Installation Guide Introduction... General.. Installation. Features Benefits.. Options Available Appendix A: Top Multi - II. Appendix B: Pedrollo NKm Pump.. Appendix C: Pressure Vessels... Appendix D: DG Flow Pressflo Controller 3 4 4 4 5 6 6 6 6 7 7 7 8 9 9 9 10 11 18 20 Appendix C: DG Flow Steady Press Controller.. Appendix F: Sterilight UV Unit. 24 26

Introduction This Installation, Operation and Maintenance ( O&M ) manual includes descriptive literature, specifications and drawings relating to the principal mechanical and electrical equipment incorporated in the unit. It is the responsibility of the installer and owner to read and fully understand these instructions before installing, commissioning or operating the unit. In the unlikely event of problems occurring with your unit you may either refer to this manual, additional manuals provided with your particular unit or contact your equipment supplier/eps directly. The unit is designed to well proven processes with our engineering expertise to produce high quality system which are robust and reliable. The unit will provide long and trouble free operation providing the simple maintenance procedures laid out in this manual or additional manuals provided with your particular unit are regularly carried out. Your attention is drawn to the Health and Safety section at the beginning of this manual. It is IMPERATIVE that you read these instructions BEFORE working on or using this unit. The unit is designed for a pumped feed, from a mains or private water supply This unit is for drinking water only and is not suitable for pumping chemicals strong acids or alkalis, oil and grease, pesticides or photographic chemicals of any kind If you have any further questions, please contact EPS

Health & Safety ( I mportant - Please Read This Before Starting Any Work on the Unit. ) Safety, Health and Welfare at Work Act 2005. Section 16.1 ( a ) of this Act requires manufacturers to advise their customers on the safety and the handling precautions to be observed when installing, operating, maintaining and servicing their products. The user s attention is there drawn to the following: 1. The appropriate sections of this manual must be read before working on the equipment. 2. Suitably trained or qualified personnel must carry out installation and servicing. 3. Normal safety precautions must be taken and appropriate procedures observed to avoid accidents. Refer to EPS or your local supplier for technical advice or product information. HEALTH Only potable water is to be connected to your Multi-Boost system. SAFETY As with all site work the dangers of working with water and electricity pose severe threats to health if obvious and fundamental precautions are not taken, therefore, if you are in any doubt with any of the following, please do not hesitate to contact us. All site work should be undertaken by qualified personnel only.

Design & Dimensions Dimensions of Standard Multi-Boost 250 Ltr 300 Ltr (Slim-line) 500 Ltr 750 Ltr O/A Diameter (mm) A 760 580 760 760 O/A Height (mm) B 1050 1600 1370 2090 Height of inlet from base (mm) C 630 1220 1000 1720 Standard Unit Approx Weight empty (kg)* 30.5 33.5 36.5 49.5 *Weight shown for standard unit pump and controllers but can vary according to customer requirements. B C A

Delivery Offloading The purchaser has overall responsibility for offloading the unit and any accessories. Do not lift the unit if it contains any water. Maintain control over the unit if lifting by use of guide ropes. Do not allow the unit to impact against other objects. If the unit is stored on site prior to installation, it must be upright on a flat and level ground where it cannot be punctured or otherwise damaged. Payment EPS require payment in full for the system prior to delivery, unless other credit terms have been agreed. Scope of Supply EPS will deliver complete Multi-Boost system as ordered.

Installation Guide INSTALLATION Step 1 Access & connect 1¼ overflow to waste drain by suitably qualified plumber. Note: As this overflow is gravity operated a minimum fall of 1:50 is recommended. Step 2 Remove inspection hatch / access & fit ( internally ) the black quick stop ball cock to the to the black inlet unit. Note: The quick stop ball cock is supplied loose for transport purposes and should only take a few seconds to fit. Step 3 Only then connect mains water supply externally to the inlet connection using provided ¾ BSP connection. Step 4 Access and connect dwelling pipework to 1 BSP outlet to supply pipe work. Note: This is to be carried out by suitably qualified plumber. Step 5 Turn on mains water and check all connections for leaks. Turn off water again once checked. Note: Ensure electrical power is off/isolated before continuing to next step. Step 6 Connect electrical supply cable ( pre-wired pump control cable ) to a suitability rated fore spur or plug-top with safety earthing connection ( 2 20v 13A single phase ). Note: Wiring of supply cable should only be carried out by a suitably qualified electrician. Electronic control 1 Drain / optional connection to parallel tank Submersible Pump c/w float switch Quick stop ball cock ( s upplied loose ) ¾ BSP inlet

Installation Guide INTRODUCTION Though every care has been taken to ensure that your Multi-Boost Water System has arrived complete. Please visually check to ensure that no damage has occurred during transport. GENERAL Before Installation please turn off water at point of entry to property/dwelling and please do not connect electrical supply until advised later in this guide as this could result in an electrical shock. Wiring of supply cable ( pre-wired pump control cable ) should only be carried out by a suitably qualified electrician. Pre-wired pump control cable 1 Outlet to supply pipe work Inspection / Access Hatch Electronic supply cable ¾ BSP inlet connection 1 ¼ BSP overflow connection to waste Before installation begins choose an area with a flat solid concrete base where your Multi-Boost Water System is protected from both frost/ vandalism ( p referably indoors as the unit is not supplied with tamper proof equipment or insulation. We recommend that this area be near to all services as this reduces the need for extra plumbing and electrical requirements. Position the unit so that all connections and the inspection cover is easily accessible. A few minutes of planning will save you time and energy.

Installation Guide FEATURES Non-corrosive holding tank Protection lid enclosure as standard Ball cock to control water flow to tank Pressure pump ( fully submerged in water ) Electronic controller - stops and starts pump Dry run protection included 1 drain off valve Connections: Inlet ¾ Outlet 1 Overflow 1 ¼ BENEFITS Ideal if mains pressure is low or inconsistent Good storage capacity in dust/vermin proof container Pump is submerged in water - no problems with leaks or priming Very silent operation Minimal installation requirements Multiple tanks inter-connection option available OPTIONS AVAILABLE Multi-Boost Presflo Multi-Boost Intelli Multi-Boost VSD Multi-Boost UV - Presflo Controller - Intelli Pressure System - Steadypress Variable - 5 Micron Filter - Pedrollo Top Multi Pump - 12 litre Vessel Speed Drive Controller - UV Disinfection System Volume Code 250 ltr 7231296 500 ltr 7231307 750 ltr 7231309 - Pedrollo Top Multi Pump Volume Code 250 ltr 7231297 500 ltr 7231300 - Pedrollo NKm 2/3 pump Volume Code 250 ltr 7231293 500 ltr 7231303 ( 4 5 I/m ) Code 7231283 750 ltr 7231310 750 ltr 7231312

Appendix A: TOP Multi - Ⅱ

Appendix B: Pedrollo NKm pump

Appendix C: Pressure Vessel

Appendix D: DG Flow Pressflo Controller

Appendix E: DG Flow Steady Press Controller

Appendix F: Sterlight UV Unit

let us make your environment a better place to be demand special treatment Borehole Pumps Multi-Boost Water Pumps Filter Housing For product enquiries, specification advice, project assessments or further information, please contact the EPS team on: Booster Sets UV Disinfection info@epswater.ie www.epswater.ie Mallow, Co. Cork Ballyhaunis, Co.. Mayo Pressure Vessels Tel: 022 31200 Fax: 022 31250 Tel: 0904 9630226 Fax: 094 9630761 Filtration Mountrath, Co. Laois Tel: 057 8732279 057 8732518 Naas, Co. Kildare Tel: 045 843614 Fax: 045 883296 Sewerage Pumps Water Softeners