Turbimax CUS31. Technical Information

Similar documents
OUS31. Technical Information

Oxymax COS61/COS61D. Technical Information

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

Oxymax W COS51D. Technical Information. Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor

Technical Information Cleanfit CUA451

Oxymax H COS21D. Technical Information

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Operating Instructions Turbimax CUS52D

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Operating Instructions Flowfit CUA252

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement

For the highest operational safety around the clock

Operating Instructions. Oxymax W COS41. Dissolved oxygen sensor. BA284C/07/en/

Armatures for analytical probes

Oxymax COS22/22D. Technical Information

Technical Information Conducal CLY421

High-performance submersible pressure transmitter For level measurement Model LH-10

Operating Instructions. Predilution chamber EC. BA 821C/24/ae/01.07

Proline Promass 200 Two-wire Coriolis measurement for the chemical industry

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

Mass Flow Controller (MFC) for Gases

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Mass Flow Controller (MFC) for Gases

Expert Hydrostatic Level Transmitters

Mass Flow Meter (MFM) for gases

Pneumatic retractable fitting for simple commercially available control units or process applications

Technical Information Oxymax COS22D/COS22

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Mass Flow Meter (MFM) for Gases

Oxygen Measurement Systems High Reliability and Wide Application Coverage

SCA Series Inverted Bucket Steam Traps

Modular Analytical Panel System with Sample preparation for Steam and Power Applications

High-performance submersible pressure transmitter For level measurement Model LH-10

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

Type 4708 Supply Pressure Regulator

Differential pressure

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Mass Flow Controller (MFC) for Gases

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Pressure Measurement Single-range transmitters for general applications

Ultrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63

Pressure Reducing Valve DMV 755

ATS430 turbidity sensor Retractable insertion assembly

Flow Measurement SITRANS F C

Operating Instructions. Oxymax COS51D. Digital sensor for dissolved oxygen With Memosens technology BA00413C/07/EN/

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Underground irrigation

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Torque Tube TB300 Digital Transmitters

Type 4708 Supply Pressure Regulator

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Manual retractable fitting with safe-to-operate rotary drive

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

C-Flow Coriolis Mass Flow Meters

aeration and mixing systems

Precision and Instrument Regulators 1/4" port size

Precision pressure sensor Basic version Model CPT6020

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Type 4708 Supply Pressure Regulator

WATER METERS.

Indumax CLS54D. Operating Instructions

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Tank Blanketing Pressure Regulators RHPS Series

AVP-F. p setting range (bar) Code No. 003H6200

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

SonoMeter 30 Energy Meters

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Operating Instructions CCS120. Sensor for total chlorine. BA388C/07/en/

Pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

Model PDT Dewpoint Transmitter

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Remeha Quinta Cascade guide

Installation, operation & maintenance manual - original version

Mechanical Pressure Measurement

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Orifice Plate Flow Meter

Level transmitter LT 100

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

Sensor for Measuring Dissolved Oxygen

Ultrasonic level transmitter and indicator

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

GA24 Technical Datasheet

ASME and PED Requirements for Drum Level Instrumentation. Presented by: Amir Hedayatnia Clark-Reliance Corp.

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

Infrared Linescanners

Liquid level instruments BM 24 /BM 51

Transcription:

Technical Information Turbimax CUS Turbidity sensor Installation and immersion sensor for drinking water and industrial water according to the 90 scattered light method Application All phases of drinking water processing Coagulation and flocculation Filter rupture monitoring Filter backwash Control of clear rinsing cycles Monitoring of phase separation processes Boiler feedwater Monitoring of cooling water Monitoring of surface waters Outlet monitoring of sewage treatment plants Monitoring of industrial water discharge Recycling of industrial water Your benefits All-purpose: Direct installation in water pipes Suitable as a drinking water sensor for every installation with a wall distance greater than 8 cm (") Measurement under pressure to avoid degassing Integrated temperature measurement Permissible distance between sensor and transmitter: 00 m (660 ft) Standardized and simple: Measurement according to EN 707 / ISO 707 Commissioning without formazine Factory calibration ( plug and play ) Cost saving and safe: Inclined plain sensor surface uses medium flow to increase the self-cleaning effect and repels air bubbles Wiper unit can be retrofitted Self-monitoring and plausibility check Scratch-resistant sapphire glass measuring window TI76C/4/ae/0.08

NTU R6 Turbimax W CUS Function and system design Measuring principle Turbidity measurement For turbidity measurement a light beam is sent through the medium and is diverted from its original direction by optically denser particels, e.g. solid matter particles. Function Nephelometric measuring principle 90 NIR scattered light according to EN 707 The 90 scattered light method with a wavelength in the near-infrared range (880 nm) according to ISO 707 / EN 707 records turbidity values under standardized, comparable conditions. A temperature signal is also recorded and transmitted in addition to the turbidity signal. The excitation radiation of an infrared transmitter (see below, item ) strikes the medium at a defined angle of beam. The different refractions of light between the entrance window and the medium (water) are taken into account. Particles in the medium (item 5) create a scattered radiation which strikes the scattered light receivers (items, 4) at a defined angle of beam. The measurement in the medium is constantly compared with the values of a reference receiver (item ). Digital filter functions with excellent interference signal suppression and sensor self-monitoring ensure additional measurement reliability. 4 4 5 Infrared sender Reference diode Scattered light receiver Scattered light receiver Particle 5 90 Turbidity measurement acc. to ISO 707 / EN 707 a000844 Measuring system A complete measuring system comprises: Turbidity sensor CUS Transmitter, e.g. Liquisys M CUM5 Assembly: Flow assembly E or S (each with installed, factory calibrated sensor) or Immersion assembly, e.g. Dipfit W CYA6 or Retractable assembly, e.g. Cleanfit W CUA45 FNU 0.7. C 4 4 Measuring system with flow assembly Flow assembly S CUS-**S Sensor cable 4 Transmitter Liquisys M CUM5 a00084 a00085 Measuring system with immersion assembly Immersion assembly Dipfit W CYA6 CUS-**A Transmitter Liquisys M CUM5 (with weather protection cover CYY0) 4 Universal assembly holder CYH0 Endress+Hauser

Input Measured variable Measuring range Turbidity 0.000 to 9999 FNU 0.00 to 000 ppm 0.0 to.0 g/l 0.0 to 00 % Power supply Electrical connection The sensor is connected to the transmitter by means of a multi-core, shielded measuring cable (fixed cable at the sensor. To extend the measuring cable, a VBM or RM junction box and a CYK8 extension cable must be used. CUS CUMx GN YE WH GND Com A Com B U B S 96 97 88 BN +U B 87 Measuring cable (fixed cable) resp. extension cable (CYK8) a00085! Note! Please pay special attention to the instructions on sensor connection in the Operating Instructions of the transmitter. Performance characteristics Maximum measured error Repeatability Wavelength < 5 % (min. 0.0 FNU) of measured value (system measured error related to the primary formazine standard / tracing according to ISO 575 and ISO 707 / EN 707) < % (min. 0.0 FNU) of measured value 880 nm Factory calibration traceable to formazine standard and SiO Endress+Hauser

Installation Wall distance Installing the sensor in pipework or very close to the wall can cause backscatter which results in a higher sensor signal. The effective wall or bottom distance can be optimized by aligning the flat sensor side. inch 4 6 8 00 0 FNU 0. 0.0 0 5 0 5 0 cm B A! Note! Effect of the distance from the wall or bottom A Dark wall or bottom (non-reflective) B Bright wall or bottom (reflective) a00088 The following generally applies: The lower the turbidity to be measured, the darker the vessel walls should be and the greater the wall distance should also be. When measuring in drinking water, the wall distance to a dark wall must be at least 8 cm ("). Bright pipes are not suitable for the drinking water sector. Pipe installation The following figure illustrates various installation positions in pipes and indicates whether they are permitted or not. 5 4 Orientation and installation positions (with adapter CUA0-A/B resp. retractable assembly CUA45) a00087 The pipeline diameter must be at least 00 mm (4") if reflective materials (e.g. stainless steel) are used. Install the sensor in places with uniform flow conditions. Orientate the sensor surface against the medium flow (self-cleaning effect). The best installation location is in the ascending pipe (see above, item ). Installation is also possible in the horizontal pipe (item 5). Do not install the sensor in places where air may collect or foam bubbles form (item ) or where suspended particles may settle (item ). Avoid installation in the down pipe (item 4). 4 Endress+Hauser

Flow operation In general Install the flow assembly as vertical as possible so that the medium flows to the sensor from below. Two sensor orientations are possible for every installation: Parallel to the medium flow Orientation parallel to the medium flow is required when using the CUR spray head. Against the medium flow Orientation against the medium flow is used to increase the self-cleaning effect in heavily-soiled media (> 5 FNU). The wall reflection is negligible here due to the high absorption.! Note! Parallel to the medium flow a0008 Against the medium flow For turbidities < 5 FNU, use the sensor versions CUS-**E or CUS-**S. a0008 Flow operation in the drinking water sector (with special calibration) When the sensor is ordered with assembly E or S, the sensor is individually calibrated in the factory with the assembly ordered. Therefore, no initial calibration on site is necessary. P P 4 P P P >P P <P 5 6 P 7 8 P P >P P <P P P Installation situations with flow assembly E resp. S a0008. Correct: pressure reduction after measurement Degassing is avoided. The gas in the water remains dissolved.. Incorrect: Pressure reduction before measurement The pressure reduction creates favourable conditions for gas bubble formation. Endress+Hauser 5

. Correct: Outlet of the assembly raised and vented Gas cannot collect in the upper section of the assembly. The outlet pipe is vented at the highest point. A slight overpressure forms in the assembly as a result of the height difference of the raised outlet. 4. Incorrect: Outlet raised but not vented A low pressure forms in the assembly if venting via the downcomer outlet pipe does not take place due to too small a cross-section. 5. Correct: Standard application in event of little initial pressure Slight overpressure due to raised outlet level, no gas collecting in the upper section of the assembly. 6. Limited application: The valve reduces the volume flow! Note! The outlet line may not be too thin or too long as otherwise a low pressure forms in the assembly. A vent for the drain line must be present. The outlet must be completely opened at regular intervals as otherwise the raising of the outlet level would not make any sense. If using a tube as the drain line, avoid formation of siphon draw (low points in the tube)! Otherwise venting does not take place. 7. Correct: Tube as outlet line Must be raised! 8. Incorrect: Tube not raised A low pressure forms in the assembly which favors gas bubble formation. In addition, low points in the tube result in siphon draw and thereby prevent venting. This results in pressure changes in the assembly. Gas bubble elimination Conventional turbidity measurements are carried out in an unpressurized sample. When the pressure on a sample (which was pressurized beforehand) is released, fine bubbles are produced which distort the turbidity measurement. There are several methods of eliminating these gas bubbles: Pressurized measurement in the bypass (pressure is not released until after the measurement). For measurements without overpressure or with slight overpressure: Free medium flow above the assembly level. The mounting location should be as low as possible to take advantage of the maximum possible pressure. Unpressurized measurement and gas bubble elimination using wiper cleaning. The wiping duration and interval can be programmed for optimum results. Reduction of the flow to the lowest possible value (50 l/h). Slight flow prolongs the period in which the medium is in the assembly. This means that gas bubbles have more time to rise to the top. The sensor response time increases slightly due to the lower flow. Flow assembly S with integrated gas bubble trap (CUS-**S) Most of the gas bubbles are sent directly to the assembly outlet in the upper half of the separated inlet (7). The other half of the medium flows into a ring channel () by means of the central pipe. The remaining bubbles rise here and are conveyed out of the measuring chamber by means of holes in the outlet () located in the centre of the assembly. Bubble-free medium () is pushed down into the measuring chamber (5). This also leads to a high flow which results in a quick response time. In addition, this almost completely prevents dirt particles settling. 7 4 5 6 7 Ring channel Outlet Bubble-free medium Drain screw (G thread) Measuring chamber Sensor CUS Separated inlet 6 5 4 Flow assembly S with gas bubble trap a000844 6 Endress+Hauser

Immersion operation When installing the sensor in immersion assemblies, please ensure that a sufficient wall distance is observed during operation. For this reason, select an installation location in which a minimum wall distance of 50 mm (6") is observed even with varying levels or altered flow profiles. Mounting in a suspended assembly with chain must therefore be avoided. The sensor must immerse at least 40 mm (.5") into the medium. mm (inch) min. 50 (6) min. 40 (.57) CYA6 with pendulum frame a00086 Environment Storage temperature -0 to 60 C (-4 to 40 F) Ingress protection IP 68 (similar to NEMA 6P) Endress+Hauser 7

Mechanical construction Dimensions NPT ¾" G 7 (8.54) 4 CUS Ø40 (.57) 9 (7.5) mm (inch) a00080 Sensor optics Photodiode (receiver) Wiper (optional) Photodiode (receiver) 4 LED (IR transmitter) a0008 59 (6.6) 96 (5.6) 40 (6.9) 75 9 (0.8) (0.75) ¾" mm (inch) 5 (.09) ¼" 5 (.05) 5 (0.98) 75 (0.8) mm (inch) CUS-**E (with assembly E) a0008 CUS-**S (with assembly S) a0008 Weight with cable length 7 m ( ft): 0.7 kg (.5 lbs.) with cable length 5 m (49 ft):. kg (.4 lbs.) Material Process connection Temperature sensor Sensor carrier plate, shaft Optical windows Flow assemblies E and S Wiper (CUS-W** only) Cable G and NPT ¾'' NTC resistor 0K at 5 C (77 F) PVC / PPS GF 40 (polyphenylene sulfide with 40% glass-fibre) Sapphire PE Rubber TPEO (polyolefine based elastomer), -40 to 0 C (-40 to 60 F) 8 Endress+Hauser

Ordering information Product structure Sensor A Standard sensor W Sensor with integr. wiper Cable length Connecting cable 7 m ( ft) 4 Connecting cable5 m (49 ft) 9 Special cable length Assembly A Without assembly E Assembly for bubblefree media S Assembly with integr. debubbling system CUS- complete order code Scope of delivery The scope of delivery comprises: Turbidity sensor acc. to the version: CUS-**A factory-calibrated sensor, without assembly CUS-**E installed and factory-calibrated in assembly for bubble-free media, with fixing bracket CUS-**S installed and factory-calibrated in assembly with gas bubble trap, with fixing bracket Operating Instructions BA76C/07/en Certificates, approvals Quality certificate Each sensor has an individual quality certificate with information on the sensor identification and calibration according to ISO 707 / EN 707. Endress+Hauser 9

Accessories Connection accessories Installation accessories CYK8 measuring cable Non-terminated measuring cable for extension of sensor cables of e.g. Memosens sensors, CUS/CUS4 wires, twisted pair with shield and PVC-sheath ( x x 0.5 mm + shield) Sold by the meter, order no. 55054 Junction box VBM For cable extension 0 terminals Cable entries: x Pg.5 or x NPT ½" Material: aluminum Ingress protection: IP 65 (i NEMA 4X) Order numbers: cable entries Pg.5: 5000987 cable entries NPT ½": 550077 Junction box RM For cable extension (e.g. for Memosens sensors or CUS/CUS4) 5 terminals Cable entries: x Pg.5 Material: PC Ingress protection: IP 65 (i NEMA 4X) Order no.: 55008 Immersion assembly holder CYH0 For ph, ORP, oxygen, conductivity assemblies and for oxygen and turbidity sensors; Ordering acc. to product structure (Technical Information TI09C/07/en) Immersion assembly Dipfit W CYA6 For sensor immersion in basins, open channels and tanks, PVC Ordering acc. to product structure, see Technical Information TI66C/4/ae Flange adapter CUA0 for CUS/CUS4 Ordering information: CUA0-A for welding flange, h=47 mm (.85") CUA0-B for welding flange, h=9 mm (.66") Flow assembly Flowfit CUA50 for CUS/CUS4 ordering acc. to product structure (Technical Information TI096C/4/ae) Retractable assembly Cleanfit CUA45 retractable assembly with ball valve; for turbidity sensors; material: stainless steel ordering acc. to product structure (Technical Information TI69C/4/ae) Welding rinse socket DN 65 order no. 55009 Welding rinse socket DN 50 / PN 6 order no. 550006 Transmitter Liquisys M CUM /5 Turbidity transmitter Panel mounting or field housing Optional with Hart or Profibus communication Ordering acc. to product structure, see Technical Information TI00C/4/ae Cleaning Chemoclean Injector CYR0 and program sequencer CYR0 Ordering acc. to product structure, see Technical Information (TI046C/07/en) Chemoclean CUR Spray head for flow assemblies CUA50 and COA50 order no. CUR- 0 Endress+Hauser

Monitoring, service kit, recalibration CUY Check unit for CUS for checking the sensor order no. 5504477 Service kit CUY spare wiper arms order no. 500895 Recalibration CUS Calibration as per ISO 707 / EN 707 order no. 500864 Endress+Hauser

USA Canada México Instruments International Endress+Hauser, Inc. 50 Endress Place Greenwood, IN 464 USA Tel. 7-55-78 Fax 7-55-8498 Sales888-ENDRESS Service800-64-877 inquiry@us.endress.com www.us.endress.com Endress+Hauser Canada 075 Sutton Drive Burlington, ON L7L 5Z8 Canada Tel. 905-68-99 800-668-99 Fax 905-68-9444 info@ca.endress.com www.ca.endress.com Endress+Hauser, México, S.A. de C.V. Fernando Montes de Oca Edifico A Piso Fracc. Industrial San Nicolás 5400. Tlalnepantla de Baz Estado de México México Tel.+5 55-5-080 Fax+5 55-5-099 eh.mexico@mx.endress.com www.mx.endress.com Endress+Hauser Instruments International AG Kaegenstrasse 45 Reinach Switzerland Tel.+4 6 75 8 00 Fax+4 6 75 5 00 www.endress.com info@ii.endress.com TI76C/4/ae/0.08 008 Endress+Hauser, Inc. Endress+Hauser