product manual H-4166 & H-4167 Voluvessel

Similar documents
product manual H-1200 & H-1250 Universal and Portable Penetrometers

product manual H-2795 Roll-a-Meter

AIR CONTENT OF FRESHLY MIXED CONCRETE BY THE PRESSURE METHOD (Kansas Test Method KT-18)

Operating Instructions

ANALOG ULTRASOUND WATTMETER USP-30

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

Density of Granular Material by Modified Sand-Cone Method for Thin Layers

SPECIFIC GRAVITY AND ABSORPTION OF AGGREGATE BY VOLUMETRIC IMMERSION METHOD

Tex-414-A, Air Content of Freshly Mixed Concrete by the Volumetric Method

Density of Soils and/or Granular Material In-place by the Sand-Cone Method

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

BULK SPECIFIC GRAVITY AND UNIT WEIGHT OF COMPACTED HOT MIX ASPHALT (HMA) (Kansas Test Method KT-15)

Tex-416-A, Air Content of Freshly-Mixed Concrete by the Pressure Method

TEST FOR STABILOMETER VALUE OF BITUMINOUS MIXTURES

Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA , United States.

Commonwealth of Pennsylvania PA Test Method No. 742 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for

Durham Geo-Slope Indicator S-510 Triaxial Cell

Tex-616-J, Construction Fabrics

VACUUM TESTING PRECAST CONCRETE MANHOLES

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

IN-PLACE DENSITY AND MOISTURE CONTENT OF SOIL AND SOIL- AGGREGATE BY NUCLEAR METHODS (SHALLOW DEPTH) FOP FOR AASHTO T 310

HCMTCB MATERIALS SAMPLING & TESTING PERFORMANCE CHECKLIST

Apr 16, 2010 LAB MANUAL 1810

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z TROXLER ELECTRONICS LABORATORIES, INC. James Pratt Phone:

Jan 10, 2002 LAB MANUAL

Ti-Pure TITANIUM DIOXIDE DETERMINATION OF OIL ABSORPTION (OA) METHOD: T WP

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Measuring Mass and Volume

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

DuPont Personal Protection Instruction Manual for Universal Pressure Test Kit No

Oct 1, 2002 LAB MANUAL SPECIFIC GRAVITY & ABSORPTION of FINE AGGREGATE AASHTO Designation T 84 (Mn/DOT Modified)

ASPHALT PLANT LEVEL 1

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL EM Washington Street Melrose, MA Phone Toll Free

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

VB-7263 Series. Application. Features. Applicable Literature

Yoke Block Instruction Manual

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

RESISTANCE OF COMPACTED ASPHALT MIXTURE TO MOISTURE INDUCED DAMAGE (Kansas Test Method KT-56)

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

VB-7273 Series. Application. Features. Applicable Literature

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650

OWNER S MANUAL. AXD 530 MicroManometer

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

DS/PI-14 DIAPHRAGM SEAL TEMPERATURE ERROR

Purpose. Introduction

with O 2 Controller Instruction Manual

TABLE OF CONTENTS. 14 Operating Instructions Load vs. Contact

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Yoke Block Instruction Manual

Operator s Manual S-492. Direct / Residual Shear Machine. Version 1.0. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA

RE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE

VBS-9263 Series. Application. Features. Applicable Literature

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

BEAM CLAY Soft Touch Bases A Series Premium Bases

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

OPERATING INSTRUCTIONS

CSA Sample Draw Aspirator Adapter Operator s Manual

TQC Bresle Chloride test 2008

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Issue OWNER S MANUAL. GAMMA RACQUET SPORTS GAMMA Sports All Rights Reserved

ST 18 Aluminium Gas Model

Compact Ball Valves ASAHI AV VALVES. Contents. User s Manual. (Page) (1) Be sure to read the following warranty clauses of our product 1

Sterile Visual Flow Indicator

KJ4000 Operating Instructions & Parts Manual NSN

ST 18 Aluminium Gas Model

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

RAM 4021-DPX Operation Manual

McDaniel. General Service Gauges. (Brass Internals) Stainless Steel Case 1 1 /2 and 2 1 /2 Gauges. All Brass 2 and 2 1 /2 Gauges M C

GILMONT ACCUCAL FLOWMETERS

! Warning, refer to accompanying documents.

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

RAM 4021 Operation Manual

Full Internal Relief Valves Instruction Manual

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

Pipettor. User Manual

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

Lab 7 Rotational Equilibrium - Torques

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL. EM201 PSI

Standard Test Method for Capillary-Moisture Relationships for Fine-Textured Soils by Pressure-Membrane Apparatus 1

easycomposites SETUP & DAILY USE INSTRUCTIONS NEVER SWITCH OFF YOUR PUMP WITHOUT FIRST CLOSING THE VALVE TO THE CHAMBER

08.60 Pycnometer. operating instructions. All it takes for environmental research. Contents

Aug 17, 2001 LAB MANUAL MAXIMUM SPECIFIC GRAVITY (RICE VOIDS TEST) OF PAVING MIXTURES AASHTO Designation T 209 (Mn/DOT Modified))

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax

ATEX ATEX

IN-PLACE DENSITY WAQTC FOP AASHTO T 209 (16)

29 Pressure, Temperature relationship of a gas

Eaton Filtration, LLC

Calcimeter Instruction Manual

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Gilson Aqua-Check Moisture Tester MA-26X

Tex-914-K, Calibrating Motorized Gyratory-Shear Molding Asphalt Press

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

Transcription:

11.09 product manual H-4166 & H-4167 Voluvessel

this is a blank page corrector

This unit has been calibrated and is ready for use as received. After set-up, calibration is recommended. Calibration Check: Verify the procedure to be used and the accuracy of the volume indicator by using the apparatus to measure containers or molds of determinable volume that dimensionally simulate test holes that will be used in the field. The apparatus and procedure shall be such that these volumes will be measured to within 1.0 percent. Containers of different volumes shall be used so that calibration of the volume indicator covers the range of anticipated test hole sizes. Note: The H- 4141 four-inch mold and the H-4161 six-inch mold described in ASTM D698 and D1557 test for moisture/density relations of soils or other molds prepared to simulate actual test holes may be used. Where several sets of apparatus are used, it may be desirable to cast duplicates of actual test holes. These sets should represent the range of sizes and irregularities in the walls of the test holes that will be encountered. These fabricated holes call be used as standards for the calibration check of the Voluvessel. This can be accomplished by forming plaster of Paris negatives in the test holes and using these forms as forms for Portland cement concrete castings, after removing the plaster of Paris negative from the concrete castings, the inside surface of the fabricated holes should be sealed watertight, and their volume determined as indicated. Method to obtain volume of container or mold to be used to check the accuracy of the voluvessel: Determine the mass of water, in grams, required to fill one of the containers. Slide a glass plate carefully over the top of the surface of the container in such a manner as to ensure the container is filled completely with water. Determine the temperature of the water in the container. A thin film of cup grease smeared on the top surface of the container will make a watertight joint between the glass plate and the top of the container. Calculate the volume of the container in cubic feet (or cubic meters) by multiplying the mass of the water, in grams used to fill the container by the unit volume of water, in milliliters per gram, at the observed temperature taken from Table 1, and dividing the result by 28317 ml/ft 3 (or 1 x 10 (6) ml/m 3. Repeat this procedure until three values are secured for the volume of the container having a maximum range of variation 0.0001 ft 3 or (2.8 x10(-5) m 3 ), Repeat this procedure for each of the containers to be used in the calibration check. Calibration check tests Place the rubber-balloon apparatus on a relatively smooth horizontal surface. Pressurize it to 5psi and then adjust the water level up or down until it's at zero on the scale. Transfer the apparatus to one of the containers and take the reading on the volume indicator when the rubber balloon completely fills the container (Notes 1 & 2). Apply pressure to the liquid in the apparatus until there is no change indicated,

on the volume indicator. Note and record the pressure. Depending upon the type of apparatus, this pressure may be as high as 5 psi (34.5 kpa). It will usually be necessary to add load (surcharge) to the apparatus to prevent it from rising (Note 3). Note and record the total amount of load added. The difference between the initial and the final readings of the volume indicator is the indicator volume value for the container. The membrane may be withdrawn from the container by applying a partial vacuum to the liquid in the apparatus. Repeat the procedure for the other containers. Note 1: If the calibration container or mold is airtight, it may be necessary to provide an air escape, since the rubber membrane can entrap air within the container and cause an erroneous volume measurement. After the volume of the container has been determined with water and prior to the insertion of the rubber balloon, small air escape holes may be provided by placing lengths of small diamter string over the edge of the container and down inside the wall slightly beyond the bottom center. This will permit air leakage during the filling o the conter with the membrane. If such a procedure is necessay in the laboratory, it may be necessary to use a similar procedure on tightly-bonded soil in the field. Note 2: Before any measurements are made, it may be necessary to distend the rubber balloon and remove air bubbles adhering to the inside of the membrane by kneading. Note 3: In field tests, additional loads (surcharge) will increase the stress in the unsupported soil surrounding the test hole and will tend to cause it to deform. Using a base plate may reduce the stress.

Table 1: Volume of water per gram based on Temperature C F Water Volume ml/g 12 53.6 1.00048 14 57.2 1.00073 16 60.6 1.00103 18 64.4 1.00138 20 68 1.00177 22 71.6 1.00221 24 75.2 1.00268 26 78.8 1.0032 28 82.4 1.00375 30 86 1.00435 32 89.6 1.00497 Values other than show may be obtained by referring to: Handbook of Chemistry and Physics Chemical Rubber Publishing Co. Cleveland, Ohio Table 2: Maximum Field Test Hole Volumes and Minimum Moisture Content Samples based on Maximum Size of Particle Maximum Particle Size Minimum Test Hole Volume ft 3 (m 3 ) Water Volume ml/g No.4 (4.75mm) 0.025 (0.0007) 100 1/2" (12.5mm) 0.050 (0.0014) 250 1" (25mm) 0.075 (0.0021) 500 2" (50mm) 0.100 (0.0028) 1000 2-1/2" (63mm) 0.135 (0.0038) 1500

Warranty Humboldt Mfg. Co. warrants its products to be free from defects in material or workmanship. The exclusive remedy for this warranty is Humboldt Mfg. Co., factory replacement of any part or parts of such product, for the warranty of this product please refer to Humboldt Mfg. Co. catalog on Terms and Conditions of Sale. The purchaser is responsible for the transportation charges. Humboldt Mfg. Co. shall not be responsible under this warranty if the goods have been improperly maintained, installed, operated or the goods have been altered or modified so as to adversely affect the operation, use performance or durability or so as to change their intended use. The Humboldt Mfg. Co. liability under the warranty contained in this clause is limited to the repair or replacement of defective goods and making good, defective workmanship. Humboldt Mfg. Co. 3801 North 25th Avenue Schiller Park, Illinois 60176 U.S.A. U.S.A. Toll Free: 1.800.544.7220 Voice: 1.708.456.6300 Fax: 1.708.456.0137 Email: hmc@humboldtmfg.com Testing Equipment for Construction Materials HUMBOLDT www.humboldtmfg.com