PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Similar documents
Model PSI Compressor with 3-Gallon Air Tank 12VDC

200 PSI FAST-FILL AIR SOURCE KIT

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

444C DUAL PERFORMANCE VALUE PACK

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

400C & 450C DUAL PERFORMANCE VALUE PACKS

200 PSI HIGH-FLOW AIR SOURCE KIT

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Portable Oil Lube Air Compressors

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

200 PSI COMPRESSORS - MODEL NUMBERS

100C Air Compressor Kit

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

IMPORTANT SAFETY INSTRUCTIONS

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Livewell/Baitwell Pumps. Livewell/Aerator

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

DeVILBISS AIR POWER COMPANY. OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR (For Home Use Only) MODEL NO. DFAC153 SPECIFICATION CHART

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

MODEL NUMBER: P PORTABLE COMPRESSOR

TECHNICAL DATA. Page 1 of 12

Installation of Your SprayMaster System

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

2 Gallon Air Compressor

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

MODEL NUMBER: P PORTABLE COMPRESSOR

480C DUAL PERFORMANCE VALUE PACK

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

TECHNICAL DATA CAUTION

KJ4000 Operating Instructions & Parts Manual NSN

Air Compressor Electric Handheld

OPERATOR S MANUAL 1.5 HP/6-GALLON 6 GAL AIR COMPRESSOR IMPORTANT: READ OPERATOR S MANUAL BEFORE USING. Toll Free Helpline:

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

VERTICAL AIR COMPRESSORS

COMPRESSOR MANUAL. (888)

VERTICAL AIR COMPRESSORS

Installation, Operating, Maintenance and Safety Instructions for MAXI-SYSTEM Pressurised water systems for boats

Budget Range Operators Handbook

OPERATING INSTRUCTIONS

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Compact Transfer Pump

Installation Instructions Air Compressor Part # 2780, 2781

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

OWNER S TECHNICAL MANUAL

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

AIR BRAKE SYSTEM TROUBLESHOOTING

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

DUAL 444C ONBOARD AIR SYSTEM

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Marschalk Model # 94000

Model 420-HY Pressure Regulating Hydrant Valve

IMPORTANT SAFETY INSTRUCTIONS

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

TECHNICAL DATA. than the water inlet pressure to the concentrate

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Operating Instructions Models and Hydrostatic Test Pumps

FloWash. Industrial Filter Cart

Operating Instructions Model and Hydrostatic Test Pump

200L BELT DRIVEN AIR COMPRESSOR

FACTORY SERVICED 8 Gallon Air Compressor. Model: Important Safety Instructions RISK OF EXPLOSION OR FIRE:

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

PC 1010 Electric Air Compressor

Model: 43T. Bermad Pressure Relief Valve

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

DS05C,D,G Dial Set Pressure Regulating Valves

TexFinish. For Water-Based Materials Only. Operation F. Interior Texture Sprayers

Proper Pump Installation Practices

Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications)

8-gallon Air Compressor. Owner s Manual

D05 Pressure Regulating Valves

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

PRO-50 Instrument Supply Regulator

Part IV: Troubleshooting

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Bermad Pressure Reducing. Model: 42T

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Transcription:

PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL BOATS WITH HIGH DEMAND REQUIREMENTS FEATURES Self-Priming Run Dry Ability Smooth Flow Low Amp Draw Two Stage Operation Easy Installation Internal Bladder Accumulator Meets USCG 183.410 and ISO 8846 MARINE for Ignition Protection SPECIFICATIONS Pump Body Glass Filled Polypropylene Pump Design Multi-Chamber Diaphragm Suction Lift Self-Priming to 5 ft. (1.5 m) Ports 3/4" Hose Motor Permanent Magnet Type with Thermal Overload Protection Accumulator Hygienic, impact and pressure resistant Plastic Construction. 33 fl. oz (1 Liter) capacity Shipping Weight 15 lb (6.8 kg) approx. APPLICATIONS The Dual Max Automatic Water System is designed for boats and RV s with multiple outlet water systems. The system operates automatically. When a faucet is opened, the system instantly begins operation to provide a smooth constant flow from tank to faucet. Closing the faucet automatically discontinues system operation. Model 31670-Series The accumulator tank smooths water flow and reduces on/off cycling of the pump by lessening the variation in pressure. Even flow of water gives better control of hot water temperature especially noticeable with instantaneous gas water heaters and showers. Reduced on/off cycling reduces noise from the pump, water hammer and gives longer pump life. VERSATILE TWO STAGE SYSTEM Under low demand conditions only the primary pump operates delivering up to 3.8 gpm. Amp draw is well below that of other high flow systems under the same conditions. Accumulator tank capacity is perfectly matched to the primary pump. An additional large accumulator is not required. Under high demand the secondary pump is activated. and flow increases. Under maximum demand total current draw is only 15 amps (12v) or 7.5 amps (24v). The dual pump configuration offers increased reliability. Should either of the system pumps become inoperable for any reason, the remaining pump will continue to function with the capability to supply several outlets. Models Gpm (Lpm) Voltage Nominal psi (bar) Cut-In Cut-Out Max Amp Draw Pump Fuse Breaker 31670-0092 7.5/28.4 12 Vdc 20 (1.4) 40 (2.8) 15 10 20 31670-0094 7.5/28.4 24 Vdc 20 (1.4) 40 (2.8) 7.5 10 10 Each of the two pumps is supplied prewired with an automotive type fuse. These fuse/holders must remain in place to isolate the pumps from each other and allow the remaining pump to operate should one fail. Customer supplied, not included with pump.

! WARNING Explosion hazard. Do not pump gasoline, solvents, thinners or other flammable liquids. To do so can cause an explosion resulting in injury or death. TYPICAL INSTALLATION Hot Water Line Water Heater INSTALLATION MOUNTING The Dual Max system is self-priming and may be located above or below the fresh water tank in a dry location. PLUMBING If the system has rigid piping, provide a short length of hose between pipe and the pump to avoid noise and vibration. Use stainless steel clamps at both ends of hose. NOTE: Inlet and outlet hose must be minimum 3/4" (19 mm) ID reinforced hose. Branch lines to outlets should be no smaller than 3/8" (10 mm). Two inlet strainers have been installed in the Dual Max system to keep debris out of system. Fresh water tank must be vented. If the system includes a city water inlet, an inlet pressure regulator which reduces pressure to 40 psi or less is required. The Jabsco 44410 Series is recommended. Avoid any kinks or fittings which could cause excessive restrictions. Remember to periodically clean faucet and! WARNING Fire hazard. Wiring must comply with applicable electrical standards and include a properly sized fuse or circuit breaker. Improper wiring can cause a fire resulting in injury or death. Pumpgard screen. WIRING The Dual Max system should be wired to the power supply through a switch rated for 20 amps (12v) or 10 amps (24v). Turn the system off when not in use for extended periods or when tank is out of water. The electrical circuit should be protected with an overcurrent protection device in the positive lead. See chart for proper size breaker. Pump circuit should not include any other electrical loads. Orange wire is positive. Black wire is negative. Select wire size from the following chart. Use total length of wire from electrical source to pump and return. Chart allows for 3% voltage drop. If in doubt, use next larger wire size. Total wire 0-20 ft 21-30 ft 31-40 ft 41-60 ft length (0-6 m) (6-9 m) (9-12 m) (12-18 m) 12 volt #10 AWG #8 AWG #6 AWG #4 AWG (6 mm 2 ) (10 mm 2 ) (16 mm 2 ) (25 mm 2 ) 24 volt #16 AWG #14 AWG #12 AWG #10 AWG (1.5 mm 2 ) (2.5 mm 2 ) (4 mm 2 ) (6 mm 2 ) If you are not familiar with applicable electrical standards, have the unit installed by a qualified electrician. Shower Faucet NOTE: Outlet is now front facing. Plumb tank to dual inlet strainers. Strainers maybe unplugged from pumps and reversed. After installation, check the voltage at the pump motor. Voltage should be checked when pump is operating along with all the inside electrical fixtures. Full voltage must be available at the pump motor at all times. Faucet Motor case will get hot. Prolonged contact during operation may cause a burn. OPERATION 1. Check level of water in tank. 2. Open all faucets hot and cold. 3. Switch pump on and wait for hot water tank and water lines to fill. 4. Close each faucet as flow becomes steady and free of air, close cold water faucet first. Pump should shut off soon after closing last faucet. 5. Pump is now ready for automatic operation. It will start when faucet is opened and stop when faucet is closed. 6. If pump will be inoperative for a considerable length of time, turn off circuit to pump and bleed pressure from system by opening faucets. ACCUMULATOR TANK PRESSURE Accumulator tank pre-charge air pressure should be checked annually. Turn pump circuit off. Open a faucet and relieve all system water pressure. Adjust pre-charge air pressure using an ordinary tire pressure gauge and tire pump. Air inlet valve is located on the end of the accumulator tank. pre-charge pressure should be 10 psi. Close faucet and turn pump power on. Fill Water City Water Inlet Regulator 44410-1000 Vent Check Valve Dual Max 31670-Series Do not overpressure tank. Pressures over 125 psi (8.6 bar) may rupture tank and cause personal injury.

EXPLODED VIEW 3 10 1 4 2 9 8 5 12 11 9 7 PARTS LIST Key Description Qty. 31670-0092 (12V) 31670-0094 (24V) 1 Upper Housing 40 PSI 1 18910-4040 18910-4040 Lower Housing 25 PSI 1 18753-0724 18753-0724 2 Valve Kit 1 18911-7030 18911-7030 3 Diaphragm Kit 1 18912-3040 18912-3040 4 Lower Housing Kit 1 18915-9002 18915-9002 5 Pressure Switch Upper Pump 40 PSI 1 18916-0040 18916-0040 Pressure Switch Lower Pump 25 PSI 1 18916-0025 18916-0025 2,3,4,8 Service Kit 1 18920-9043 18920-9043 7 Motor Kit Upper and Lower Pump 2 18753-0721 18753-0721 8 Slide Clips 4 18753-0722 18753-0722 9 Accumulator 1 30573-0000 30573-0000 10 Port Kit, 3/4 Elbow 4 30642-1000 30642-1000 11 Port Kit, 1/2 NPT(M) 2 30649-1000 30649-1000 12 Strainer 2 18753-0723 18753-0723 Pumphead, Complete Upper Pump 40 PSI 1 18914-6340 18914-6340 Pumphead, Complete Lower Pump 25 PSI 1 18914-6225 18914-6225 * When replacing upper pump it is necessary to remove Body (3), rotate 180 and reassemble then remove Pressure Switch Body (2), rotate 180 and reassemble. DIMENSIONAL DRAWING Inches (Millimeters) 14.0 (356) 13.625 (346) 7.75 (197) 13.25 (337) 8.75 (222) 7.0 (178)

Pre-Pressurized Air Cushion 10 psi SAFETY RELIEF VALVE RECOMMENDED It is recommended that a relief valve with a setting of no more than 125 psi be installed. Often a relief valve is already installed at the water heater. Check its setting. This will protect the system in case the pressure switch fails. HOW THE PRESSURE ACCUMULATOR WORKS A. Factory installed precharged air cushion. B. When pump starts, water enters the reservoir. At maximum pressure, system is filled. Pump shuts off. C. When water is demanded, pressure in the air chamber forces water into the system. Pump stays off until minimum pressure is reached. Then pump turns on. Bladder 40-75 psi 0-10 40-75 30 A. B. C. Do not overpressure tank. Pressures over 125 psi (8.6 bar) may rupture tank and cause personal injury. TROUBLESHOOTING PULSATING FLOW - PUMP CYCLES ON AND OFF Leaking water fixture or faucet Accumlator tank has no pre-charge air pressure Restricted water filter or pipe MOTOR FAILS TO TURN ON Pump circuit has no power Blown fuse/thermal Protector tripped Loose wiring connection Pressure switch failure Defective motor Air Valve 30 psi MOTOR OPERATES BUT NO PUMP DISCHARGE Debris in check valve assembly Restricted intake or discharge line Air leak in intake line Punctured pump diaphragm PUMP FAILS TO TURN OFF AFTER ALL FIXTURES ARE CLOSED. Empty water tank Punctured pump diaphragm Discharge line leak Defective pressure switch Insufficient voltage to pump Debris under flapper valves LOW FLOW AND PRESSURE Debris in check vavle assembly Air leak at pump intake Defective motor Motor has thermal overload protection Motor will automatically shut off if temperature rises due to an overload condition. If the motor shuts off in this manner, close all faucets and valves. Pump will automatically re-start when motor cools. WINTERIZING YOUR WATER SYSTEM Follow these steps to remove all water from your water system: 1. Drain water by opening tank drain, or open a fixture to allow pump to operate until tank is dry. 2. Open the lowest outlet in water system to drain lines. 3. To remove any remaining water (about a cup), remove outlet hose on pump and activate pump. To blow out lines, attach air nozzle where outlet hose was removed. Make sure all fixtures are open before starting. 4. Your water system is now winterized. Don t forget to reattach the outlet hose and close all fixtures. Do not use automotive type anti-freeze. It is poisonous. Use of this type antifreeze will cause serious internal injury or death. THE PRODUCTS DESCRIBED HEREIN ARE SUBJECT TO THE JABSCO ONE YEAR LIMITED WARRANTY, WHICH IS AVAILABLE FOR YOUR INSPECTION UPON REQUEST.

For technical advice or service please take your pump into your local pump service center. To order pump or parts or for pricing please go to the following links : Jabsco Pumps Home >> Jabsco Pumps stock list >>