CALIBRATION. empanelled laboratories following standard procedures and using certified reference standards.

Similar documents
Sr. No. General points CPCB Comments 1. Print option, acknowledgement of submission for CPCB OCEMS Protocol

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

METHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE)

EN ISO/IEC Technical Requirements

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

APPENDIX C. 40 CFR PART 60 App. B SPEC. 1-4, 6

HCL MONITORING. ICAC MARAMA WORKSHOP May 18-19th, Presented by: Ty Smith. CEMTEK

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

This test shall be carried out on all vehicles equipped with open type traction batteries.

STD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

THE FUNDAMENTALS OF THE AIR SAMPLER CALIBRATION-VERIFICATION PROCESS

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT METHOD INSTRUMENTAL ANALYZER PROCEDURES FOR CONTINUOUS GASEOUS EMISSION SAMPLING

Protocol Gas Verification For Compressed Gas Cylinders Containing Either SO 2, NO or CO. Quality Assurance Plan/Standard Operating Procedure

Improve Process Reliability

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

The analysis of complex multicomponent

20. Technical Equipment. Archived. This section applies to all equipment used in forensic examinations, such as

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Technical Paper. Selection of Particulate Monitors. Author: William Averdieck, PCME Ltd

DEPARTMENT OF ENVIRONMENTAL PROTECTION Air Quality. 35 P.S. Sec (Air Pollution Control Act) and Act 95 (75 PA C.S.

SM8200. SO2/NO In Situ Multi-Gas Analyzer

Columbus Instruments

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

Particularly with regard to CHAPTER 5 MEASURES TO BE TAKEN AGAINST AIR POLLUTION CAUSED BY TWO OR THREE- WHEEL MOTOR VEHICLES

PRODUCT CONFORMITY CERTIFICATE

Online DGA-monitoring of power transformers

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

Air Monitoring Directive Chapter 7: Calibration

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator

Controls and Control Charting

Application Note AN-107

BAPI Pressure Line of Products - FAQs

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

SEMEM3-78 Testing and calibrating instrumentation and control equipment and circuits

COAL MINES TECHNICAL SERVICES, GAS DETECTION RELATED SERVICES FOR MINES RESCUE

EMISSION SURVEY FOR SONAE NOVOBORD: WHITE RIVER. Report No. 565/12 FR.1. March 2013 C & M CONSULTING ENGINEERS PO BOX LYNNWOOD RIDGE 0040

APTI 464. Analytical Methods for Air Quality Standards. Laboratory Exercise Manual. March 2010

Service Calibration are you doing it properly?

SFHGEN77 - SQA Code HD48 04 Perform first line calibration on clinical equipment to ensure it is fit for use

Thermo Scientific Model 146i Principle of Operation

Automatic Isokinetic Sampler. ST5 Evo

RULES PUBLICATION NO. 119/P

PQAO Training 2017 Karl Tupper, San Luis Obispo APCD

O3 3E 1 F Gas Sensor Module

Central scientific research automobile and automotive engine institute

Calibration and Bump Test Requirements for Direct Reading Portable Gas Monitors

Guidelines for Real Time Sampling & Analyses

Elimination of Percent Level H 2 S Calibration Gas from Flare Gas Monitoring Systems Measuring Total Sulfur, H 2 S and BTU.

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

Periodic Survey of Fuel Installations on Ships other than Liquefied Gas Carriers utilizing gas or other low flash point fuels

Standard Operating Procedure for H 2 S and SO 2 Converter

Phosgene Sensor. Sensoric COCl2 3E 1

CHAPTER 7 : SMOKE METERS AND THEIR INSTALLATIONS

Ti-Pure TITANIUM DIOXIDE DETERMINATION OF SLURRY RHEOLOGY METHOD: T WP

Outside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program

Ozone. Sensoric O3 3E 1

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA

ANSI / ASSE Z88.2 American National Standard Practices for Respiratory Protection (1992 rev. versus 2015 rev.)

Proposed Uniform Standards for Equipment Leaks

Because every life has a purpose. MSA Z GARD S Sensor Calibration Procedure

General Accreditation Guidance. User checks and maintenance of laboratory balances

Supplementary Certificate of Approval. No S433

Quality Assurance Charting for QC Data

CORESTA RECOMMENDED METHOD N 6

Appendix. Part 1: References Part 2: Automatic Analysers 114

Protocol Gas Verification Program (PGVP)

Commandant United States Coast Guard

Ultima. X Series Gas Monitor

Automatic Isokinetic Sampler. ST5 Evo

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

Gas Mixture Two Components. Gas Mixtures Two Components

Los Gatos Research. High performance analysers for the measurement of trace gases, greenhouse gases and stable Isotopes

Requirements and Methods for Calibration of Equipment in Clinical Laboratories. NK Chan (HKRCBTS) 24 August 2007

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

GasSense NDIR User Manual

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Gas Network Craftsperson

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

Vehicle- or rack-mounted liquefied gas meters, pump supplied

ATTACHMENT O WIPP MINE VENTILATION RATE MONITORING PLAN

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Model EXAxt AV550G. Averaging Oxygen Analyzer

LQG Based Robust Tracking Control of Blood Gases during Extracorporeal Membrane Oxygenation

SEMEM4-40 Carrying out the testing and calibration of instrumentation control equipment and circuits

Trace Environmental Systems

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Speciality Gases Practice 4. Our quality, your safety. Accredited Test and Calibration Laboratory Speciality Gases Centre in Hörstel.

Particulate Emission Monitor Correlation. Camden Power Station Stack No RSL152

Vehicle and Engine Emissions Testing

Transcription:

CALIBRATION A. Calibration of Air Analysers Gaseous Parameter a. The instruments/ analysers for real time monitoring of gaseous emissions shall be calibrated with respect to their functioning, drift, linearity detection limit, output, operating temperature and other relevant parameters before installation. b. It is advised to mention that calibration for certified CEMS and full performance demonstration of uncertified CEMS (which involves calibration) must be performed while being installed. c. After six months of operation, the system shall be rechecked for its health and data accuracy and reliability, following multi point calibration (at least 03 span concentrations) using standard methods and certified reference materials. d. The data comparison and calibration verification shall be done once in 06 months by empanelled laboratories following standard procedures and using certified reference standards. e. The health of the instruments/analysers shall be assessed on daily basis at fixed time (10.00 a.m.) by checking the zero drift. No adjustment is allowed. f. In case the daily zero drift is more than the acceptable limit as specified in the catalogue/brochure of the instrument/analyser manufacturer and persists continuously for five days, the instrument/ analyser shall be recalibrated following procedure laid down at point (d) above. g. The instruments/ analysers shall be rechecked for zero and span drift every Friday at fixed time (10:00 a.m.) using standard methods and standard reference materials. The drift needs to be recorded and suitably incorporated in the data collected over the period. h. For Differential Optical Absorption Spectroscopy (DOAS), Non Dispersive Ultra Violet (NDUV)/Non Dispersive Infra-Red lamp based systems, the calibration shall be revalidated once in 03 months, and after replacement of lamp. In-situ based TDLS/ DOAS needs to be brought down to lab for calibration. i. The values of NDUV / NDIR based system will be compared with the standard methods using Standard Reference Material every Friday at fixed time (10.00 am) and Zero drift checked daily at fixed time (10.00 am). j. The instrument/ analyser shall be recalibrated after any major repair/replacement of parts/lamps or readjustment of the alignment using standard methods and certified reference materials.

k. The instrument/ analyser system shall have provision of remote calibration, for verification of the system performance by SPCBs/PCCs whenever, felt necessary. l. The intensity of the lamp shall be checked once every fortnight. m. Data capture rate of more than 85% shall be ensured. n. For FTIR Spectroscopy calibration once a year checks are acceptable or when major over haul as change in Lazer / Spectrometer. o. Using Air for Zero/Span calibration is not acceptable, Zero / Span Gas / Gas filled Cuvette to be used with required certifications. Particulate Matter The PM CEMS device is ready for calibration only after performing all of the required installation, registration, and configuration steps. Details of Particulate Matter CEMS calibration are given below. a. The continuous Particulate Matter monitoring system (PM-CEMS) shall be calibrated at different operational loads against isokinetic sampling method (triplicate samples at each load) at the time of installation and thereafter, every six months of its operation. b. The results from the Particulate Matter monitoring system shall be compared on fortnightly basis i.e. second Friday of the fortnight, at fixed time (replicate sample) starting 10.00 am. with standard isokinetic sampling method. c. In case, deviation of the comparison values for 02 consecutive monitoring is more than 10%, the system shall be recalibrated at variable loads against isokinetic sampling method (replicate samples). d. No adjustment of Calibrated Dust Factor (CDF) is allowed unless full-scale calibration is performed for PM CEMS. Change of CDF should be permitted only if it is approved by SPCB/ PCC. e. After any major repair to the system, change of lamp, readjustment of the alignment, change in fuel quality, the system shall be recalibrated against isokinetic sampling method. (triplicate samples at each load) f. The data capture rate of more than 85% shall be ensured. g. The intensity of lamp shall be checked once every fortnight. h. The data comparison/calibration verification shall be done by laboratories empanelled by CPCB using standard reference methods and at a frequency specified.

General parameters The following parameters shall also be monitored:- (i) Carbon Dioxide (CO 2 ) (for normalising the values) (ii) Stack gas velocity (iii) Flue Gas Volumetric Flow Rate (iv) Flue Gas Temperature (v) Stack Gas Parameters(Flue gas pressure) (vi) Oxygen (O 2 ) (vii) Carbon Monoxide (CO) (viii) H 2 O/Moisture in in-situ/ Hot Water Measurement B. Effluent Quality Monitoring (i) (ii) (iii) (iv) (v) The instruments/analysers for real time monitoring of effluent discharges/ shall be calibrated with respect to their functioning, drift, linearity detection limit, output, response time, repeatability of temperature and other relevant parameters before installation. After six months of operation, the analysers/ instruments /sensors shall be checked for their health, data accuracy and reliability following multi point calibration (at least at 3 span concentrations) using standard laboratory methods and certified reference materials. Comparison of the values of ph, COD, BOD, TSS and TOC as recorded by the analysers/instruments/sensors shall be done on a fortnightly basis i.e, second Friday of the monthly, at fixed time, starting 10.00 am., using standard reference materials. In case deviation of the comparison values exceeds the target accuracy specified for the parameter, the analyser/instrument/sensor shall be rechecked for its accuracy again on the next day, following standard laboratory methods and standard reference materials. In case the deviation of the comparison values is beyond the target accuracy for the specified parameters for 2 consecutive days, the system shall be recalibrated in the laboratory following multi point calibration (at least 03 span concentration) using standard laboratory methods and certified reference material.

(vi) In case of any change in effluent matrix, the correlation between TOC: COD & TOC: BOD with laboratory reference method in case of TOC analyser and for COD and BOD with laboratory reference method in case of UV-Visible Spectroscopy shall be rechecked. (vii) The data capture rate shall be more than 85%. (viii) The data comparison/calibration verification shall be done by laboratories empanelled by CPCB using standard reference methods and certified reference standard material as specified and at a frequency specified.

Criteria for Empanelment of Laboratories (i) Laboratories recognised under the Environmental (Protection) Act, shall only be considered for empanelment. (ii) The EPA recognised Laboratory having achieved robust statistical Z score more than 70% in the laboratory proficiency testing shall only qualify for empanelment. (iii) The empanelled Laboratory shall participate in the proficiency testing programmes organised by CPCB twice a year. (iv) The empanelment of Laboratories, failing to achieve the required Z score in the proficiency testing shall be kept in abeyance, till their performance in the next round of proficiency testing meets the prescribed score. (v) Laboratories failing consecutively twice in achieving the desired Z score in proficiency testing shall not be considered for empanelment and/or their empanelment withdrawn (vi) CPCB shall arrange for Analytical Quality Control Proficiency Testing programmes for Air Pollutants along with the Water Quality parameters. (vii) The Head Quarter/ Zonal Office laboratories of CPCB shall verify performance of atleast 2% of the installed real time monitoring systems every year. (viii) The data comparison/calibration shall be done by empanelled laboratories at frequency specified under para- Calibration.