Animal Bed Mouse Cryo

Similar documents
Animal Bed Rat Cryo. User Manual. Innovation with Integrity. Version MRI

Bruker Sample Transport

Bruker BioSpin NMR CASE. System Requirements Manual. Version. NMR Spectroscopy. think forward

LC-SPE. Organizer 3.0 User Manual. Innovation with Integrity. Version 001 NMR

Bike holder with three-point-support for mounting stand

A Quick Start Guide for the ER 4123D CW-Resonator

Techcon Systems TS1254 Pressure Pot

VLI Visible Level Interface Operation & Maintenance Manual

Agilent 1290 Infinity Pump Head Maintenance

Operating instructions - Translation of the original -

Operating instructions - Translation of the original -

Universal Gage. Multimar 844 T

BPS-2, Rev TABLE OF CONTENTS

Operating Manual. 3S-R AirElite Full Face Mask Advantage AirElite Full Face Mask Advantage 4000 AirElite Full Face Mask. AirElite - Full Face Masks

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Model Visit our website at:

Installation and Maintenance Instruction Manual

DOLOMITE Legacy. Rollator User Manual

OptiAir CA09 Pneumaticfluidizing

SOTR Special Operations Tactical Respirator

AIR INLINE METAL SHEAR

Techcon Systems TS1258 Pressure Pot

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

foldable/adjustable sawhorse

Assembly, Installation and operating. instructions for. Söll-Xenon anchorage device

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Portable Massage Table

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

Installation Instructions

USER GUIDE TO POWER ASSISTED BIKES

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

M5400 Operators Manual

User Instruction Manual

Pipettor. User Manual

CART FOR CENTURION 1500+

User Manual. Quantos Automated Dosing Liquid Module

Varipette Operating manual

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

PH01 Perfusion Cannula Manual

User manual. ZX trolley.

CP-D/CP-M Circular Polarizer for Phoroptor. User s Guide

222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions

80 Litre Suction Oil Drainer

BR 27g. Operating, assembly and maintenance instructions for discontinuous sampling valve. 1. Design, operation and dimensions:

WIKA INSTRUMENT CORPORATION

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

INSTRUCTION MANUAL. January 23, 2003, Revision 0

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

DL 8 Dome Port. Product Registration. Product Number 75340

Operating instructions - Translation of the original -

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

Tribomatic II Powder Pump

Repair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B

BNL. User Manual. Innovation with Integrity. Version. Accessories

Elcometer 123. Surface Profile Gauge. Operating Instructions

The World s Best Adductors

VL PONTOON/TRITOON DECK BRACKET 13 INSTRUCTIONS

User Guide. Tripod. flowtech 75 / 100 Tripod. Part No. S S

MoveRoll Conveyor Operating and Maintenance Manual

BSS 2 Bottle Sampling System. Instruction manual Version 1.8

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E

RayPette Plus Autoclavable Pipette. User Manual

Instrument Operating Manual

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

3/8" Dr. Air Butterfly Impact Wrench

Squeegee Unit for MRS Multi-Recovery System

RADROVER REAR RACK INSTALLATION MANUAL

Pfeiffer. Operating, assembly and maintenance instructions for discontinuous sampling valve Series 27i. 1. Design, operation and dimensions

TFS230 FLOOR STRIPPER OPERATION & MAINTENANCE

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

UNIVERSAL TUBE HOLDER SYSTEM

Portable Massage Table User Manual

deluxe toilet safety support

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

C - SERIES. Height Adjustable Portable Goal Supports. Installation & Owner s Instructions C1000 C2000. Made in the USA

Operating and maintenance manual Filter and reducing station Series / 1.0

Model ASSEMBLY and OPERATING INSTRUCTIONS

The pipettes cover a volume range from 0.1µl to 10ml.

COMPACT METAL bender 99826

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

ATS430 turbidity sensor Retractable insertion assembly

GI Series Diaphragm Pressure Gauge Guard

BSMS/2. PNK Pneumatic Module Technical Manual. Version 001 BRUKER

Instructions for use Compressed air injector with water trap

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

DM-RARD (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike. Rear Derailleur DURA-ACE RD-R9100 ULTEGRA RD-R8000

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

DM-MARD (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike REAR DERAILLEUR XTR RD-M9100 RD-M9120

12V MINI AIR COMPRESSOR

Operating Instructions. ATMOS Chair Comfort. English GA1GB Index 01

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

REMS Swing INSTRUCTION MANUAL SINGLE-HAND TUBE BENDER SWING ANCRA

Transcription:

Animal Bed Mouse Cryo User Manual Version 003 Innovation with Integrity NMR

Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means without the prior consent of the publisher. Product names used are trademarks or registered trademarks of their respective holders. December 8, 2014: Bruker Corporation Fällanden, Switzerland P/N: Z31858 DWG-Nr.: Z4D10825 003b For further technical assistance on the Animal Bed Mouse Cryo unit, please do not hesitate to contact your nearest BRUKER sales representative or contact us directly at: BRUKER Corporation Industriestrasse 26 CH-8117 Fällanden Switzerland Phone:+ 41 825 97 97 FAX:+ +41 825 94 04 E-mail:cryoprobe.service@bruker.ch Internet:www.bruker.com

Contents Contents 1 About...5 1.1 This Manual... 5 1.2 Policy Statement... 5 1.3 Symbols and Conventions... 5 2 Introduction...7 2.1 General Purpose... 7 2.2 Disclaimer... 7 2.3 Version 03.00... 7 2.4 Before You Begin... 7 2.5 The Bruker Service... 7 3 Product Overview...9 3.1 Bio Animal Bed Mouse Cryo and Mouse Position Gauge... 9 3.2 Heating Cover... 9 4 Handling...11 4.1 Provided Tools... 11 4.2 Anesthesia and Fixation... 11 4.3 Balancing Ring... 13 4.4 Lifting Mechanism... 13 4.5 Mouse Position Gauge... 14 4.6 Handling of the Bio Animal Bed Mouse Cryo on the MRI System... 15 5 Material & Cleaning...17 5.1 Material... 17 5.2 Cleaning... 17 6 Scope of Supply...19 6.1 Spare parts for Animal Bed Z114100, Z112268 and Z122287... 19 7 Contact...21 Z31858 / Rev.: 03 3

Contents 4 Z31858 / Rev.: 03

About 1 About 1.1 This Manual This manual is intended to be a reference guide for operators and service technicians. It provides detailed information about the user level maintenance and overall use of the Bruker device. The figures shown in this manual are designed to be general and informative and may not represent the specific Bruker model, component or software/firmware version you are working with. Options and accessories may or may not be illustrated in each figure. Carefully read all relevant chapters before working on the device! 1.2 Policy Statement It is the policy of Bruker to improve products as new techniques and components become available. Bruker reserves the right to change specifications at any time. Every effort has been made to avoid errors in text and figure presentation in this publication. In order to produce useful and appropriate documentation, we welcome your comments on this publication. Support engineers are advised to regularly check with Bruker for updated information. Bruker is committed to provide customers with inventive, high quality products and services that are environmentally sound. 1.3 Symbols and Conventions Safety instructions in this manual are marked with symbols. The safety instructions are introduced using indicative words which express the extent of the hazard. In order to avoid accidents, personal injury or damage to property, always observe safety instructions and proceed with care. CAUTION This combination of symbol and signal word indicates a possibly hazardous situation which could result in minor or slight injury unless avoided. Z31858 / Rev.: 03 5

About NOTICE This combination of color and signal word indicates a possibly hazardous situation which could result in damage to property or the environment unless avoided. This symbol highlights useful tips and recommendations as well as information designed to ensure efficient and smooth operation. 6 Z31858 / Rev.: 03

Introduction 2 Introduction 2.1 General Purpose The Animal Bed is suitable for magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) examinations of mouse brains using an MRI CryoProbe. It can be used within BRUKER BioSpec, PharmaScan and ClinScan systems. The Animal Bed provides a stereotactic fixation and a setup for gas anesthesia. 2.2 Disclaimer The unit should only be used for its intended purpose, as described in this manual. Use of the unit for any purpose other than that for which it is intended is taken only at the users own risk and invalidates all manufacturer warranties. Service or maintenance work on the unit must be carried out by qualified personnel. Only trained persons should operate the unit. Read this manual before operating the unit. Pay particular attention to any safety related information. When handling the animal, local regulations must be strictly adhered to. 2.3 Version 03.00 The manual is written for all Bio Animal Bed Mouse Cryo for BRUKER BioSpec, PharmaScan and ClinScan systems. 2.4 Before You Begin This user manual contains information that are necessary for a safe operation of the device. Consider all safety references! 2.5 The Bruker Service Our customer service division is available to provide technical information. For contact details see Contact on page 21. Z31858 / Rev.: 03 7

Introduction 8 Z31858 / Rev.: 03

Product Overview 3 Product Overview 3.1 Bio Animal Bed Mouse Cryo and Mouse Position Gauge The base of the Animal Bed system (Figure 3.1) consists of a half shell made of PEEK with a diameter of 68 millimeters (Figure 3.1 (1)). [1] Animal support area of the Animal Bed where the animal is positioned [2] Rear end to guide the Animal Bed into the magnet with lifting arm mechanism to position animal under the Coilhead [3] Adjustable balancing ring [4] Mouse Position Gauge for testing the correct position of the animal Figure 3.1: Total view of the Animal Bed and Mouse Position Gauge. 3.2 Heating Cover A heating cover (Figure 3.2 (1)) to stabilize the body temperature of the mouse during investigation is provided with the Animal Bed. The heating cover has to be connected to a conventional water heating system. Figure 3.2: Animal Bed with heating cover (1). The temperature of the water heating system has to be adjusted in order to stabilize the animals physiological body temperature. Z31858 / Rev.: 03 9

Product Overview 10 Z31858 / Rev.: 03

Handling 4 Handling 4.1 Provided Tools CAUTION Risk of injury! Therefore: When tightening screws within the 0.5 mt line of the magnet only use the nonmagnetic screw driver provided with the Animal Bed! 4.2 Anesthesia and Fixation [1] White fixation screw [2] Red extension screw [3] Slotted headless screw [4] Respiration mask [5] Tooth bar [6] Ear plug [7] Heating cover [8] White screws [9] Ear plug holder [10] Mechanical stop Figure 4.1: Animal support area. [1] Respiration mask reverse [2] Slotted headless screw [3] Red extension screw [4] Silicon tube for narcotic gas supply [5] Silicon tube for narcotic gas aspiration [6] Headless screw for fixation [7] White screws Figure 4.2: Animal support area - Reverse setup. Z31858 / Rev.: 03 11

Handling [1] Silicon tube for narcotic gas supply [2] Silicon tube for narcotic gas aspiration Figure 4.3: Bottom view of the animal support area - gas supply. The animal support area consists of the following parts: Anesthetic gas supply: A passive gas anesthesia including supply and aspiration is provided within the respiration mask. The respiration mask (Figure 4.1 (4)) is connected to the two silicon tubes (supply: Figure 4.3 (1), aspiration: Figure 4.3 (2)). While in the reverse setup, the respiration mask reverse (Figure 4.2 (1)) is connected via the two silicon tubes (supply: Figure 4.2 (4), aspiration: Figure 4.2 (5)). Respiration mask (Figure 4.1) / Respiration mask reverse (Figure 4.2): The respiration masks can be shifted within a certain range. To reposition the respiration masks (Figure 4.1 (4) & Figure 4.2 (1)) loosen the white fixation screw (Figure 4.1 (1)) or the headless screw (Figure 4.2 (6)), respectively. To use the reverse setup, it is recommended to remove the respiration mask (Figure 4.1 (4)). Place the respiration mask reverse (Figure 4.2 (1)) and connect the two silicon tubes for supply (Figure 4.2 (4)) and aspiration (Figure 4.2 (5)). Tooth bar: To adjust the position of the tooth bar (Figure 4.1 (5)) apply the red extension screw (Figure 4.1 (2)) and loosen the slotted headless screw (Figure 4.1 (3)). After positioning the tooth bar fix the slotted headless screw and remove the extension screw. This procedure applies also for the respiration mask reverse, the red extension screw (Figure 4.2 (3)) can be applied and the slotted headless screw (Figure 4.2 (2)) can be loosend to shift the mask. Stereotactic fixation: Figure 4.1 (8) shows the stereotactic fixation device which is realized by ear plugs fitting into the ear canals for the top end setup, while Figure 4.2 (7) shows it for the reverse setup. The position of the ear plug within the ear canal can be adjusted by moving the complete ear plug holder (Figure 4.1 (9)) and the ear plugs (Figure 4.1 (6)) independently. To move the complete ear plug holder loosen the white screw (Figure 4.1 (8)). The ear plugs do have a thread and can be moved by using the provided non-magnetic screw driver. Mechanical stop: To adjust the position of the object to be imaged in relation to the centre of the Coilhead the mechanical stop (Figure 4.1 (10)) can be moved. To do so, turn the screw (Figure 4.5 (2)) at the end of the Animal Bed. The correct position can be checked by using the Mouse Position Gauge ("Mouse Position Gauge" on page 14). 12 Z31858 / Rev.: 03

Handling Connect the tube of the narcotic gas aspiration to the specific exhaust system within the lab. The specific exhaust system has to be adjusted with the appropriate flow in order to ensure a stable anesthesia of the animal. NOTICE Hazardous situation of damaging the Coilhead due to punctiform pressure! Mouse can freeze in. Therefore: Remove the extension screw (Figure 4.1 (2)) whenever the bed is used in the Mouse Position Gauge or the MRI system. It is not allowed to position the respiration mask beyond the end of the Animal Bed otherwise the function cannot be guaranted. Place the Animal Bed in the Mouse Position Gauge to check for any possible collision with the Coilhead ("Mouse Position Gauge" on page 14). 4.3 Balancing Ring The functionality of the lifting mechanism is only guaranteed if the Animal Bed is balanced. Therefore, the balancing has to be checked and probably adjusted for each measurement. 1. Position the fully equipped Animal Bed on a flat table and check for the balancing. 2. Loosen the screw (2) and move the ring (1) so that the Animal Bed is balanced. 3. Tight the screw again. Figure 4.4: Balancing ring. 4.4 Lifting Mechanism The lifting mechanism is controlled by the blue lever (Figure 4.5 (1)) at the end of the Animal Bed. When the blue lever is positioned in the down position the lifting arm (Figure 4.6 ((1)) is counter-sunk within the Animal Bed (Figure 4.6). Moving the blue lever into the up position (Figure 4.7 (1)) lifts the front end of the Animal Bed by pushing Z31858 / Rev.: 03 13

Handling out the lifting arm (Figure 4.8 (1)). The lifting mechanism is force limited. NOTICE The blue lever has to be in the down position when installing and removing the Animal Bed in/from the Mouse Position Gauge and the MRI system! Figure 4.5: Blue lever (1) fixed in down position. Figure 4.6: The lifting arm (1) counter-suck in the Animal Bed. Figure 4.7: Blue lever (1) in up position. Figure 4.8: The lifting arm (1) is pushed out and the Animal Bed is lifted towards the Coilhead. 4.5 Mouse Position Gauge The Mouse Position Gauge (Figure 4.9) displays the real situation of placing an imaging setup underneath the Coilhead. Therefore, it does have two functions. For safety reasons it has to be used to check for any possible collision of the imaging setup and the Coilhead. Furthermore, it can be used to check for the correct position of the imaging setup in relation to the Coilhead and the functionality of the lifting mechanism. Installing the Animal Bed into the Mouse Position Gauge has to be done without significant forces. If not possible the setup has to be checked for collisions. The cross on the acrylic glass marks the centre of the Coilhead (Figure 4.9 (1)). It can be used to check for the correct position of the subject to be imaged in relation to the Coilhead. 14 Z31858 / Rev.: 03

Handling. Figure 4.9: Mouse Position Gauge for testing the correct position of the mouse. The cross marks the center of the Coilhead. 4.6 Handling of the Bio Animal Bed Mouse Cryo on the MRI System NOTICE Before installing a new imaging setup into the MRI system, any possible collision of the setup with the Coilhead has to be checked by using the Mouse Position Gauge! The CryoProbe has to be installed in the MRI system before the Animal Bed can be installed! Installation and removal of the Animal Bed is only possible when the blue lever is in the down position! Installation 1. Check for the correct installation of the CryoProbe in the MRI system before installing the Animal Bed. 2. To install the Animal Bed into the MRI system, move the blue lever into the down position. 3. The Animal Bed has to be moved into the MRI system from the patient end. 4. Constantly check for the correct rotation of the Animal Bed while moving it into the MRI system until the mechanical stop is reached. 5. Put the blue lever into the up position. Removal 1. Put the blue lever into the down position. 2. Carefully remove the Animal Bed from the MRI system. Again check for the correct rotation of the Animal Bed. Z31858 / Rev.: 03 15

Handling 16 Z31858 / Rev.: 03

Material & Cleaning 5 Material & Cleaning 5.1 Material The half shell of the Animal Bed system is made of PEEK. PEEK is normal fire-proof according to the guidelines of DIN 4102 B2. The maximum operating temperature should not exceed 75 C air temperature, also without mechanical load. The Animal Bed is a highly complex and delicate accessory. It should be handled with great care. Do not drop or bend the Animal Bed and avoid impact with hard objects which may scratch or damage it. 5.2 Cleaning For cleaning, neutral antistatic plastic cleaners or desinfection cleaners are recommended. Commercial household cleaners without polishing agents can be used. Never use cleaners that contain organic solvents such as benzene, acetone or chlorinated hydrocarbons. Also, alcohol cleaners in high concentration must not be used, otherwise the Animal Bed system can be severely damaged. NOTICE Cleaner containing organic solvents or alcohol can damage the Animal Bed. Therefore: Use only neutral antistatic plastic cleaners or disinfection cleaners. Commercial household cleaners without polishing agents can also be used. Z31858 / Rev.: 03 17

Material & Cleaning 18 Z31858 / Rev.: 03

Scope of Supply 6 Scope of Supply 6.1 Spare parts for Animal Bed Z114100, Z112268 and Z122287 Figure 6.1: Explosion view of the Animal Bed showing the spare parts which can be separately ordered as listed in Table 6.1 on page 19 and Table 6.2 on page 20. Scope of supply in Fig. 7.1 Part number Description Material 1a Z142282 Ear plug holder Type 1 low POM (acetal plaste) white 1b Z142283 Ear plug holder Type 2 POM black 2 Z113768 Ear plug POM black 3 28477 Screw M3 x 4 PA (polyamids) 4 24221 Connector Luer male 1.6mm PP 5 Z113760 Toothbar long 24 mm POM black 6 Z113761 Toothbar short 19 mm POM black 7 Z113763 Headless screw M3 PEEK 8a Z142284 Respiration mask mouse PMMA 8b Z142285 Respiration mask mouse PMMA reverse 9 2014 Screw M3 x 6 PA Table 6.1: Parts for Animal Bed are shown in Figure 6.1. Please check with Figure 6.1 and the table what has to be replaced or is missing. Z31858 / Rev.: 03 19

Scope of Supply Scope of supply in Fig. 7.1 Part number Description Material 10 23025 O-rings 15 x 1 PMMA 11 Z113765 Guide rail right 180 flex long PEEK 12 Z113764 Guide rail left 180 flex long PEEK 13 Z113766 Locking screw PEEK 14 Z128975 Knurled screw red M4 PA 15 T151393 Heating cover Z113800 Screw driver CUBE2PB Z31858 A bed mouse cryo operation inst. Table 6.2: Parts for Animal Bed are shown in Figure 6.1. Please check with Figure 6.1 and the table what has to be replaced or is missing. 20 Z31858 / Rev.: 03

Contact 7 Contact MRI CryoProbe Sales: BRUKER BioSpin MRI GmbH Rudolf-Plank-Str. 23 D-76275 Ettlingen Germany phone: + 49 721 5161-6500 fax: +49 721 5161-6539 email: mri@bruker-biospin.de www.bruker-biospin.com/mri MRI Support Hotlines Support Hotline Hardware phone: + 49 721 5161-6521 email: mri-hardware-support@bruker.de Support Hotline Application phone: + 49 721 5161-6621 email: mri-application-support@bruker.de MRI CryoProbe services: BRUKER AG Service Department Industriestrasse 26 CH-8117 Fällanden Switzerland phone: + 41 44 825 97 97 fax: + 41 44 825 94 04 e-mail: mricryoprobe.service@bruker.ch http://www.bruker.ch BRUKER Instruments, Inc. 44 Maning Road Billerica, MA 01821 U.S.A. phone: ++1-978-667-9580 fax:++1-978-667-0985 email: center@nmr.bruker.com http://www.bruker.com Please refer to the Model No., Serial No. and Internal Order No. in all correspondence regarding the MR system or components thereof. Z31858 / Rev.: 03 21

Contact 22 Z31858 / Rev.: 03

Revision History List Index: Date: Alteration Type: 01 15.06.2009 First Release of the Animal Mouse Bed Cryo Manual Rev.:01 02 28.03.2010 Second Release of the Animal Mouse Bed Cryo Manual Rev.:02 Two possibilities to place the animal within the bed 03 4.09.2014 Third Release of the Animal Mouse Bed Cryo Manual Rev.:03 Z31858 / Rev.: 03 iii

Bruker Corporation info@bruker.com www.bruker.com Order No: Z31858