Flow Scanner. Production logging in multiphase horizontal wells

Similar documents
New power in production logging

PITFALLS OF RUNNING CONVENTIONAL PRODUCTION LOGGING IN HORIZONTAL/HIGHLY DEVIATED WELLS: A CASE STUDY

COPYRIGHT. Production Logging Flowmeter Survey Solution Guide

Cased-Hole Logging Environment

Section 2 Multiphase Flow, Flowing Well Performance

CHDT Cased Hole Dynamics Tester. Pressure testing and sampling in cased wells

PRODUCTION I (PP 414) ANALYSIS OF MAXIMUM STABLE RATE AND CHOKES RESOLVE OF OIL WELLS JOSE RODRIGUEZ CRUZADO JOHAN CHAVEZ BERNAL

HRLA High-Resolution Laterolog Array Tool. Improving the accuracy of Rt

Advanced Applications of Wireline Cased-Hole Formation Testers. Adriaan Gisolf, Vladislav Achourov, Mario Ardila, Schlumberger

Gas Lift Workshop Doha Qatar 4-88 February Gas Lift Optimisation of Long Horizontal Wells. by Juan Carlos Mantecon

Situated 250km from Muscat in

PowerDrive X6. Rotary Steerable System for high-performance drilling and accurate wellbore placement

Perforating Options Currently Available in Horizontal Shale Oil and Gas Wells. Kerry Daly, Global BD Manager- DST TCP

GEOTHERMAL WELL COMPLETION TESTS

North American sealing solutions Bridge Plug Ball Drop Frac Plug Caged Ball Frac Plug

FREQUENTLY ASKED QUESTIONS

FORMATION TESTER MOBILITY. Lachlan Finlayson, Chief Petrophysicist Petrofac Engineering & Production Services Engineering Services Consultancy

Bridge Plugs, Ball Drop & Caged Ball Plugs For Zone Isolation

PRODUCTION AND OPERATIONAL ISSUES

North Dakota Petroleum Council Re-stimulation Initiative

W I L D W E L L C O N T R O L PRESSURE BASICS AND CONCEPTS

and its weight (in newtons) when located on a planet with an acceleration of gravity equal to 4.0 ft/s 2.

International Journal of Petroleum and Geoscience Engineering Volume 03, Issue 02, Pages , 2015

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

Comparative temperature measurements in an experimental borehole heat exchanger. Vincent Badoux 1, Rita Kobler 2

COPYRIGHT. Production Logging Fundamentals. By the end of this lesson, you will be able to:

Drilling Efficiency Utilizing Coriolis Flow Technology

Wind Flow Validation Summary

B04 Guided Interpretation #4

DRILLSCENE PROACTIVE DRILLING DECISIONS

Testing Services Overview

ARTICLE. Overcome casing integrity issues in your plug-and-perf operations

STUDY OF SLUG CONTROL TECHNIQUES IN PIPELINE SYSTEMS

SCORPION HIGH-QUALITY, FULLY COMPOSITE PLUGS

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Bioreactor System ERT 314. Sidang /2011

COMPUTER PROGRAM TO ANALYZE MULTIPASS PRESSURE-TEMPERATURE-SPINNER SURVEYS. Paul Spielman Reservoir Engineer

Measurement of Velocity Profiles in Production Wells Using Spinner Surveys and Rhodamine WT Fluorescent Tracer; Geothermal Field (California)

EXPERIMENTAL RESULTS OF GUIDED WAVE TRAVEL TIME TOMOGRAPHY

Acoustic Pulse Reflectometry Brings an End to Tube Inspection Sampling By Dr. Noam Amir, Chief Technology Officer, AcousticEye

Contact Information. Progressive Optimization Service. We Provide: Street Bay #2. Grande Prairie, AB T8V - 4Z2

New generation of solid expandable liners help give operators a jump on trouble zones

Design Tapered Electric Submersible Pumps For Gassy Wells Desheng Zhou, SPE, Rajesh Sachdeva, SPE, IHS INC.

Perforating Center of Excellence TESTING SERVICES OVERVIEW

Chapter 8: Reservoir Mechanics

UNIT 2 PATTERNS OF NATURAL

Environmental Science: An Indian Journal

Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System

2007 Gas-Lift Workshop

Well Control Modeling Software Comparisons with Single Bubble Techniques in a Vertical Well

OIL AND GAS INDUSTRY

Seismic Survey Designs for Converted Waves

Bubble Tube Installations

TUTORIAL. NPSHA for those who hate that stuffy word. by Jacques Chaurette p. eng. copyright 2006

Chapter 5 HORIZONTAL DRILLING

Digiquartz Water-Balanced Pressure Sensors for AUV, ROV, and other Moving Underwater Applications

The key to connectivity

Technical Note. Determining the surface tension of liquids by measurements on pendant drops

Moyno ERT Power Sections. Operational Guidelines

3 1 PRESSURE. This is illustrated in Fig. 3 3.

Modeling Multilaterals

COMPARATIVE EVALUATION OF ARTIFICIAL LIFT METHODS ON A NIGER DELTA FIELD

DB Bridge Plug. Features. Benefits. Applications

Debris Management Drilling Tools

W I L D W E L L C O N T R O L FLUIDS

S-CO 2 Brayton Recompression Loop Design and Control

Permeability. Darcy's Law

A Successful Experience in Optimization of a Production Well in a Southern Iranian Oil Field

WELL SCAVENGER. Versatile wellbore clean-up tool for the most demanding operations

INSPECTION OF MULTI-DIAMETER PIPELINES OPERATING AT LOW PRESSURE. Stefan Vages > ROSEN Group

OCEAN DRILLING PROGRAM

APPENDIX A1 - Drilling and completion work programme

Using Gas Lift to Unload Horizontal Gas Wells

Hydraulic Optimization Worksheet for MS Excel All Versions subsequent to 5.0

Beam Pumping to Dewater Horizontal Gas Wells

The Discussion of this exercise covers the following points:

Measurement of Water in a Wet Gas

1. The principle of fluid pressure that is used in hydraulic brakes or lifts is that:

An approach to account ESP head degradation in gassy well for ESP frequency optimization

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

Coiled Tubing string Fatigue Management in High Pressure Milling Operation- Case Study

Sucker Rod Pumping Workshop Technology in a Mature Industry. September 2017 John C. Patterson Consultant Retired from ConocoPhillips (2015)

Perforations Cleanup with Surge Chambers to Increase Well Productivity SLAP Jorge Patino, Halliburton. Oct 18 th, 19 th & 20 th, 2016

Well Testing Plan. New York Marginal Well Study. Introduction. I. Tests to be Conducted. II. Testing Procedures

On-Off Connector Skirt

Next Generation Quartz Pressure Gauges

RMAG, Snowbird, UT, October 6-9, Michael Holmes, Antony M. Holmes, and Dominic I. Holmes, Digital Formation, Inc.

OLGA. The Dynamic Three Phase Flow Simulator. Input. Output. Mass transfer Momentum transfer Energy transfer. 9 Conservation equations

Plunger Fall Velocity Model

the asset can greatly increase the success rate of Coriolis technology in this application. 3 Coriolis measurement in multiphase flow

The Use of ILI In Dent Assessments

Using PV Diagram Synchronized With the Valve Functioning to Increase the Efficiency on the Reciprocating Hermetic Compressors

Coal Bed Methane (CBM) Permeability Testing

Well Testing and Modelling of Discharging Big Bore and Super Big Bore Wells

TECHNICAL BENEFITS OF CJS / RAISE HSP. Technical Advantages

PUV Wave Directional Spectra How PUV Wave Analysis Works

E02 Rigid hinged stinger with piggyback line

Tool Weight Analysis An Engineering Approach to Optimize Pressure Temperature and Spinner Data Acquisition

STATISTICS BASED SYSTEM DESIGN FOR PERFORATED CLUSTERS

Fully coupled modelling of complex sand controlled completions. Michael Byrne

Transcription:

Flow Scanner Production logging in multiphase horizontal wells

Applications Multiphase flow profiling in nonvertical wells Identification of fluid and gas entries in multiphase well or liquid in gas wells Detection of fluid recirculation Stand-alone, real-time, threephase flow interpretation Benefits Unambiguous flow profiling in nonvertical wells regardless of phase mixing or recirculation More accurate flow measurements than possible with conventional logging tools in highly deviated and horizontal wells Three-phase flow rates computed in real time using dedicated algorithms Features All sensor measurements simultaneous and at the same depth Combinable with PS Platform* and other cased hole logging tools Short length for running in wells with high dogleg severity Direct, localized measurements of phase velocities and calculation of a multiphase velocity profile Full three-phase holdup answer from the same depth Scanning sensors across the vertical axis for more accurate detection of phase interfaces Measurement of mixed and segregated flow regimes Independent measurement of gas velocity in multiphase horizontal wells Detection of heavy phase recirculation downhole Software optimization and real-time display of data from all 19 sensors Caliper and relative-bearing measurements for continuous sensor location Multiphase fluid dynamics In vertical wells and wells with deviation less than 2, oil and water are mixed across the entire wellbore, with oil, the lighter phase, increasing on the upper side of the well. The velocity profile is smooth, and the water holdup profile varies gradually across the pipe. Averaged measurements across the wellbore are adequate to determine the velocity and holdup with this type of flow structure. Once deviation exceeds 2, however, the center measurements of conventional production logging tools are usually inadequate for multiphase flow profiling. For wells with deviation between 2 and 85, some portions of the wellbore have monophasic flow, but the overall flow structure is complex., the heaviest phase, segregates to the bottom of the pipe, and the mixing layer is on the upper side of the hole with dispersed bubbles of oil. is frequently recirculated at low flow rates, and the water velocity on the lower side of the hole can be negative in some areas. At high flow rates, differential acceleration of phases caused by the shear forces between the different fluids can lead to instabilities in the flow structure. This flow structure has large gradients in the velocity and holdup profiles. and water flows in wells with deviations between 85 and 95 are predominantly stratified. flows at the bottom with oil on the top. Even for flow rates as high as 2, B/D in a 5-in. [127-mm] liner, there is little mixing. At low flow rates, the flow has a strong dependence on well deviation. When gas is also present, depending on the well deviation, as many as six major flow regimes can be encountered. For a constant flow rate, the holdup and velocity profile of each phase vary with the well deviation. Biphasic experiments carried out in a controlled flow loop with equal flow rates for oil and water show the dramatic effects of borehole deviation on flow behavior. Flow regime in near-vertical well. Top Bottom 1 Holdup Top Bottom Flow regime in deviated well. 1 Holdup Top Bottom Top Bottom Flow regime in near-horizontal well. 1 Holdup Top Bottom Top Bottom

Flow loop experiment with equal flow rates for oil and water. Relative speed 6, Total flow rate (B/D) 1,5 6 89 9 91 Deviation from vertical At 9 the velocities and holdups of oil and water are nearly equal. Because oil is more viscous than water, it has a slightly lower velocity. The oil holdup is slightly higher than the water holdup. As soon as the borehole deviates slightly from 9, the oil and water flow at different velocities. At high flow rates the dependence on borehole deviation is smaller because the increasing shear frictional forces against the wall and interface dominate. At deviation lower than 9 (uphill), water, the heavier phase, slows down, and oil velocity increases. The water holdup increases while the oil holdup decreases. Any gas present would start to slug. At well deviation above 9 (downhill), flow is still predominantly stratified. The water flows much faster than the oil because of its higher fluid density. The water holdup now decreases while the oil holdup increases. Why conventional production logging technology is inadequate in nonvertical wells Using production logging to accurately determine the inflow of oil, gas, and water phases is fundamental to developing optimum production strategies and designing remedial workovers. But in highly deviated wells conventional production logging tools deliver less-than-optimal results because they were developed for vertical or nearvertical wells. Downhole flow regimes in deviated boreholes can be complex and can include stratification, misting, and recirculation. Segregation, small changes in well inclination, and the flow regime influence the flow profile. Logging problems typically occur when conventional tools run in deviated wells encounter top-side bubbly flow, heavy phase recirculation, or stratified layers traveling at different speeds. Flow loop studies have also revealed the ineffectiveness of conventional logging tools in multiphase flows. Center measurements made by such tools are inadequate for describing complex flow because the most important information is located along the vertical diameter of the wellbore. Conventional tools have sensors spread out over long distances in the wellbore, making measurement of complex flow regimes even more difficult.

The solution: Flow Scanner system The Flow Scanner* horizontal and deviated well production logging system was developed especially for highly deviated and horizontal to nearhorizontal wells. On one side of the tool s retractable arm are four miniature spinners designed to measure the well fluidvelocity profile. On the other side are arrays of five electrical and five optical probes for measuring localized water and gas holdups, respectively. Additionally, a fifth miniature spinner and a sixth pair of electrical and optical probes on the tool body measure flow properties on the low side of the well. All sensor measurements are made at the same depth simultaneously. The Flow Scanner system is run eccentered, lying on the low side of the well with its arm deployed across the vertical diameter of the wellbore. The arm is extended to a length equal to the diameter of the production tubulars, so it serves as a caliper, providing the area measurements needed to calculate flow rates. The tool has a small outside diameter (OD) of 1 11 16 in.[42.9 mm], and it can be run in holes ranging from 2 7 8 in. to 9 in. [73. to 228.6 mm] using coiled tubing, wireline, or the MaxTRAC* well tractor system. Its short 16-ft [4.9-m] length makes it ideal for wells with high dogleg severity. When an even shorter toolstring is desired, the 4-ft [1.2-m] hydraulic section used for scanning and closing the tool can be removed. The system operates in temperatures to 32 F [15 C] and at pressures to 15, psi [13,425 kpa]. The Flow Scanner system is combinable with the PS Platform system and other cased hole logging tools. The Flow Scanner tool uses a maneuverable arm to deploy sensors along the vertical axis of nonvertical wells to obtain velocity and holdup measurements in mixed and segregated flow regimes. A conventional spinner measures flow in the center of the wellbore, regardless of the flow profile, whereas the Flow Scanner spinners measure velocities at five different points across the vertical axis of the wellbore. The average velocity measurement of the conventional spinner would not account for the negative velocity measured here by the bottom spinner of the Flow Scanner tool. Multiphase velocity profiling Because the Flow Scanner tool measures the velocity profile along the vertical diameter of the wellbore, it can measure velocity variations that cannot be detected using a single, centered spinner. It provides measurements of mixed and segregated flow regimes, including direct independent measurement of gas velocity in a multiphase horizontal well. The Flow Scanner tool even detects water recirculation downhole.

Each of the five miniature spinners makes a direct, localized measurement of the velocity of the fluid passing through it, enabling calculation of a multiphase velocity profile. Distinguishing hydrocarbons from water The Flow Scanner system detects water by using six low-frequency probes that measure fluid impedance. Because water conducts electric current, whereas oil and gas do not, a threshold is set that allows the tool to distinguish oil and gas from water. Each probe generates a binary signal when oil or gas bubbles in a watercontinuous phase, or droplets of water in a hydrocarbon-continuous phase, touch the probe s tip. holdup is determined by the fraction of time a probe s tip is conducting, and the water holdup profile accurately represents the flow regime in the wellbore. This methodology enables a local water holdup measurement, independent of fluid properties, without any need for calibrations. Conventional tools, on the other hand, require accurate calibration in oil and water. Furthermore the bubble count measurement the log that represents the number of nonconducting events detected during a monitoring interval can be used to locate fluid entries. Conventional tools also lack the accuracy to do this. Distinguishing gas from liquids Conventional low-frequency probes can only distinguish water from hydrocarbons, but the Flow Scanner system is also equipped with optical probes for gas detection. Its six GHOST* Gas Holdup Optical Sensor Tools are sensitive to the fluid optical refractive index. Typically gas has an index near 1, water near 1.35, and crude oil near 1.5. Because oil and water have very similar fluid indices, the optical probes are used to distinguish gas from liquid. The gas bubble count can also be obtained from the raw data and used to locate first gas entries. Optical probes allow a local gas holdup measurement without requiring calibration because their signals are binary. On the basis of the fluid optical refractive index, GHOST probes make a binary distinction between gas and liquids. Real-time flow rate and phase distribution data are continuously optimized and displayed on the Flow Scanner system monitor. Surface 9 88 Surface 92 45 Together, the optical and electrical probes deliver a full three-phase holdup answer from the same depth interval. Flow Scanner monitor box Flow Scanner software optimizes and displays the data sent uphole from the spinners and probes. Two views are constantly updated with real-time acquisition data. One view shows relative fluid velocities measured by the spinner array, while the other shows phase distribution across the pipe section. For both views, the pipe is sliced horizontally into the five layers associated with the different combinations of spinner, electrical-probe, and optical-probe measurements. Surface Surface In the spinner view, five rectangles are plotted with lengths proportional to the rotational velocities of the corresponding spinners. Each rectangle is divided into color-coded sections with widths proportional to the three phase holdups seen by the electrical and optical probes. In the cross-sectional view, each layer is color coded to represent the phase with the highest holdup seen by the probes. The holdup values of the two remaining phases are represented by proportionate numbers and sizes of bubbles. The relative positions of the sensors are also shown, with circles for the spinners and dots for the probes.

Case study: Gulf of Suez Aging reservoirs in the Gulf of Suez produce viscous oils at high water cuts through deviated to horizontal completions. Conventional production logging tools often have difficulty defining the complicated flow regimes and identifying areas for water shutoff to maximize oil recovery as a field nears its economic limit. One well with an inclination of 37 was producing with gas lift through six open intervals. Production was 2,58 B/D with 97% water cut. When a conventional production logging survey was unable to evaluate individual interval contributions or identify sources of water production, the Flow Scanner tool was deployed on wireline. The figure compares logs from the Flow Scanner and conventional production logging surveys. The Flow Scanner flow profile shows that approximately 25% of the oil and 85% of the water were being produced from perforations below X4 ft. The remainder of the water and some oil were produced from perforations at X39 ft. The two perforations above X39 ft were producing clean oil, and more than half of the oil was flowing into the top perforation. Conventional production logging sensors could not detect oil entering the top perforations because the spinner was affected by water recirculation, and the resolution of the gradiomanometer was too low for it resolve oil contributions. The conventional survey erroneously attributed 9% of the oil production to the lower perforations. On the basis of the Flow Scanner results, a workover operation was planned to optimize the oil production. After cross-referencing the log results with geologic information on the location of a sealing layer of shale, the operator set a plug at X4 ft to isolate the majority of the high water-cut zones in the bottom of the well. The resulting production of 556 BOPD and 2,532 BWPD represented an 8% increase in oil production, and payback was accomplished in less than a week. Case study: North Sea The Flow Scanner system was run in a North Sea well on coiled tubing. The well was producing 9,8 BOPD, with 2% water cut and no gas, through a 4 1 2-in. [114-mm] liner. Maximum deviation over the 2,3-ft [7-m] interval is 93. In the flow profile shown in Track 1 both oil and water were produced from the lowest perforations in the well, but the major inflow of oil was at X68 m. Production increased significantly closer to the heel of the well. The holdup profile in Track 2 shows the effect deviation has in horizontal wells. Holdup varies greatly when flow rates are low, and it lessens as flow rate increases, eventually reaching a point at which deviation has almost no effect. This proves the flow-loop tests are representative of actual conditions downhole. The Flow Scanner system identified and quantified zonal oil and water production in this well in the Gulf of Suez after conventional production logging had failed. A workover operation led to an 8% increase in oil production. Depth, ft Conventional PL Flow Scanner Conventional PL Flow Scanner Conventional PL Flow Scanner Fullbore Spinner Gradiomanometer Fluid Density Flow Profile Flow Profile Spinner Stations Density Stations rps 3 4 ft/min 4.9 g/cm 3 1.2.92 1. Fluid Density ft/min 4 Image.9 g/cm 3 1.2 -Holdup Image Flow Flow Flow Flow Well Sketch X35 X4

The Flow Scanner system demonstrated in this North Sea well that the effect of deviation on holdup decreases as flow rates increase. YY6 True Vertical Depth (m) YZ4 1 Flow Profile (m 3/h ) MD 1 : 4 m Perforation X X1 X2 X3 X4 X5 X6 X7 X8 Case study: Middle East A client in the Middle East wanted to test the Flow Scanner system in a well considered to be single phase. The 52 deviated well was producing 3,3 BOPD, with no water. The Flow Scanner system was run on wireline and recorded the field log shown in the figure. The relative bearing measurement (purple) in Track 1 shows that the tool kept its sensors deployed across the vertical axis with only slight movement and remained within 1 throughout the pass. Track 2 shows the holdup of each phase in the well. It clearly shows water to 1 ft below the surface. Track 3 is a velocity image. Negative velocity (recirculation) is shown in yellow, then orange, and red as it increases; increasing positive velocity (production) is shown in blue, then green, and dark green. is being produced in the middle and on the high side of the well, while water is recirculating on the low side of the well (left). Recirculation could be seen to 1 ft below the surface. Tracks 4 and 5 represent the water flow rate (negative) and the oil flow rate (positive) calculated using the default pitches for all five spinners. Tracks 6 and 7 show the gamma ray, pressure, and temperature curves recorded with the PS Platform basic measurements sonde. This Middle East well was producing 3,3 BOPD with % water cut. Holdup measurements show water to 1 ft below the surface, and the velocity image shows that the water is recirculating. PS Platform Deviation 4 ( ) 6 Cable Memorized 1 (ft/min) 1 Calibrated Caliper 5 (in.) 7 FSIT RB 2 ( ) 2 X X1 5,. 1.. Total Holdup 1. 5,. 21. 5. 2. 1..5.4.3.2.15.1.5.1.1.5.1.15.2.3.4.5 1. 2. 5. Mixture Image (full range) (m/s) Flow Rate Flow Rate Gamma Ray Well Pressure (psia) 5, Well Temperature 1, (B/D) 4, (B/D) 5, 1 25 ( F) 275

Flow Scanner Specifications OD (in. [mm]) 1.668 [42.9] Length (ft [m]) 16. [4.9] Weight (lbm [kg]) 18 [49] Temperature ( F [ C]) 32 [15] Pressure (psi [kpa]) 15, [13,425] Corrosion resistance Borehole coverage Three-phase holdup accuracy ±1% accuracy ±1% NACE Standard MR175 9% in 6-in. ID Hole size (in. [mm]) 2.875 to 9 [73. to 228.6] Min. restriction (in. [mm]) 1.813 [46.] Flow Scanner tool only. Basic measurement sonde and head add 1.2 ft [3.1 m]. An eccentralizer and swivel are also recommended in deviated wells. www.slb.com/oilfield 6-PR-39 August 26 *Mark of Schlumberger Copyright 26 Schlumberger. All rights reserved. Produced by Schlumberger Marketing Communications