Thermoflex Online. October 5 th, 2017 Bram Kroon

Similar documents
CHAPTER 7: THE FEEDBACK LOOP

Cycle Isolation Monitoring

Performance Monitoring Examples Monitor, Analyze, Optimize

COMPRESSORS WITH SIDE STREAM

Hazard Operability Analysis

POWER Quantifying Correction Curve Uncertainty Through Empirical Methods

FUEL GAS FIRING CONTROL RJ (Dick) Perry Safety Systems Consultant 6 June 2016

The Advancement of Pressure Independent Technology

"PROVING HOUSE LOAD OPERATION OF GAS TURBINE IN PREMIX MODE IN CASE OF GRID FLUCTUATION"

A large Layer of Protection Analysis for a Gas terminal scenarios/ cause consequence pairs

Committee on NFPA 85

Characterizers for control loops

Transmitter CS 21 Operation Manual

RICK FAUSEL, BUSINESS DEVELOPMENT ENGINEER TURBOMACHINERY CONTROL SYSTEM DESIGN OBJECTIVES

On-Stream Tightness Testing of Vacuum Process Installations

Technical Consultancy Services. Forensic Engineering and Expert Witness. ERA Technology Limited

Transmitter CS 21 Operation Manual

Steam System Best Practices 14 Best Practices for Guide Lines for Boiler Plant Log Books

deltaflowc deltaflowc Venturi or Probe

Avoiding Short Term Overheat Failures of Recovery Boiler Superheater Tubes

Advanced Test Equipment Rentals ATEC (2832) OMS 600

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Screw Compressors 11-22kW

How to Select High Pressure and Gas Bypass

Cascade control. Cascade control. 2. Cascade control - details

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

GasSense NDIR User Manual

EXPERIMENTAL SUPPORT OF THE BLEED AND FEED ACCIDENT MANAGEMENT MEASURES FOR VVER-440/213 TYPE REACTORS

Gas Turbine Performance Analysis

Benefits of Detailed Compressor Modeling in Optimizing Production from Gas-Lifted Fields. Manickam S. Nadar Greg Stephenson

FAULT DIAGNOSIS IN DEAERATOR USING FUZZY LOGIC

Inerting System Design for Medium Speed Vertical Spindle Coal Pulverizers TABLE OF CONTENTS

DISTILLATION PRESSURE CONTROL TROUBLESHOOTING THE HIDDEN PITTFALLS OF OVERDESIGN

Yokogawa Systems and PCI Training

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

SAMSON SOLUTIONS Energy and Power (Critical Applications)

MARKET OUTLOOK. Power Chemicals Petroleum Water/Wastewater Oil & Gas Pulp & Paper and more

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

Supercritical CO2 Power Cycles: Design Considerations for Concentrating Solar Power

Heat Pump Connections and Interior Piping

UsER manual for Watersens ph -REDOX

EXPERT SYSTEMS IN ULTRASONIC FLOW METERS

INTRODUCTION AND METHODS OF CMAP SOFTWARE BY IPC-ENG

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Improving distillation tower operation

Gas Accumulation Potential & Leak Detection when Converting to Gas

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers

Datasheet: K-30 ASCII Sensor

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Dynamic Analysis of a Multi-Stage Compressor Train. Augusto Garcia-Hernandez, Jeffrey A. Bennett, and Dr. Klaus Brun

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

Visualize Nitrogen Gas Consumption

Improve Reliability of Turbomachinery Lubrication and Sealing Systems

SL G3 - Fuel Conversion to Natural Gas (LP to NG) P-Kit 301

Understanding Centrifugal Compressor Capacity Controls:

Influence of real phase equilibria on the sizing of pressure relief devices

Online DGA-monitoring of power transformers

The Nitrogen Threat. The simple answer to a serious problem. 1. Why nitrogen is a risky threat to our reactors? 2. Current strategies to deal with it.

STICTION: THE HIDDEN MENACE

Flow metering in gases Introduction to COMBIMASS family

Measurement Technology

Process Control Loops

Measuring range Δp (span = 100%) Pa

TOOL BOX 033- HOSEREEL SERVICE / FAULT FINDING

Ultima. X Series Gas Monitor

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)

Model EXAxt AV550G. Averaging Oxygen Analyzer

E A C S. Engine Altitude Conditions Simulator. Technical description

Natural Gas Conditioning Skids & Equipments

ME 200 Thermodynamics I Spring 2010 (Last) (First) Thermo Number: CIRCLE YOUR LECTURE BELOW

Effect of noise in the performance of the transducers in an ultrasonic flow meter of natural gas

Prudhoe Bay Oil Production Optimization: Using Virtual Intelligence Techniques, Stage One: Neural Model Building

Data Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

BUBBLER CONTROL SYSTEM

HOW TO MANAGE VAPORIZATION IN AN ANALYTICAL SYSTEM By Dean Slejko and Tony Waters

Modelling of the Separated Geothermal Water Flow between Te Mihi flash plants

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

SL G3. Warning

Technical Service Bulletin March 2015 TSB142.01

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

CMC IMPLEMENTATION IN OBSOLETE ISKAMATIC TG CONTROL SYSTEM

KOMPRESSOREN COMPRESSORS KAESER AIR SERVICE Our Services An Overview

Remotely-installed Hydraulic Module

GAS FUEL VALVE FORM AGV5 OM 8-03

FTC130 Transmitter. Operating Manual

CONTROL VALVE TESTING

Valve Communication Solutions Axiom

The ERCB Directive 017 Overview

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

VIA ELECTRONIC FILING

Transient Analyses In Relief Systems

Transformer fault diagnosis using Dissolved Gas Analysis technology and Bayesian networks

1. Functional description. Application program usage. 1.1 General. 1.2 Behavior on bus voltage loss and bus voltage. 1.

SENSITIVITY ANALYSIS OF THE FIRST CIRCUIT OF COLD CHANNEL PIPELINE RUPTURE SIZE FOR WWER 440/270 REACTOR

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

S-CO 2 Brayton Recompression Loop Design and Control

Transcription:

Thermoflex Online October 5 th, 2017 Bram Kroon

Introduction Name Company: Department: Location Position: Thermoflex Bram Kroon Engie Energie Nederland (Generation) Eems & Lelystad Power Plant Process Engineer Eight Years of experience in Modelling (CCGT and coal fired) < - Eems: CCGT 5 x 360 MW Maxima: -> CCGT 2 x 440 MW

CONTENTS The Challenge Our Solution Used technology Output of the tool Advantages of a Thermoflex model Examples Extra s LIVE DEMO of The Tool Thermoflex Model

The Challenge The spark spreads for CCGT s are small and under pressure Actual performance needs to be as close as possible to optimal performance Availability needs to be high Small deviations in operational data can be an indicator for developing faults But the optimal performance of a CCGT is not a fixed number it depends on Load Ambient air temperature Ambient air pressure Cooling water temperature Gas quality Etc. The challenge is how to accurate and reliable monitor the performance 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 4

Our solution Use a thermodynamic model that takes all the variables into account Make real-time calculations with on-line data Model calculated data are written to PI Compare the actual measurements with the model calculated results Use trends to see the behavior in time more clearly Advantages: Fuel savings due to early alarming when small performance deviations are detected; Prevent (big) damages by being able to see that a component stays within its operating window 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 5

Technology used Thermoflex (modeling software) PI (Process database) Excel and VBA (Data exchange between Thermoflex and PI PI processbook (Visualisation) 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 6

Example of Thermoflex model. 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 7

Output of the tool (PI Processbook) Dashboard (operators) Most important indicators Alarm when deviation reality/model too high Heat Balance sheet (process specialist on site) Compare flow, temperature, pressure model and real measurement Alarm when deviation too high Trends (process specialist on site / Thermodynamic Expert) Compare measurements, performance indicator over time Analytic tool 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 8

High level view: dashboard (Main user: operator) 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 9

Second level view: Heat balance sheet, with alarms (Main user: Process responsible on site, thermodynamic expert) Measured Calculated 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 10

Third level: trends (Main user: thermodynamic expert from EOS, process specialist from site) 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 11

Benefits of Thermodynamic Model (Off-line) Knowledge building during model development and discovering faults Measuring failures: Wrong: ranges, calibrations, Pgauge Pabs, Gas properties, ect. Make real correction curves (ambient T,P,rel%,Tcoolw,LHV, C/H, etc.), (non commercial) It s necessary to know the exact heatrate Findings: Steam temperatures in part load were higher then design temperatures. (creep) What if studies Minimum load studies and testing: Pmin 280MW 110 MW Increase efficiency: Using: inlet air heating, flex load-path, max IGV Reduce home-load: Optimize condenser cooling water flow. Reduce feedwater pressure setpoint. Gas-preheating and building-heating on stack-loss basic design. Basic design study for new desuperheater. (Challenging design of OEM) Optimize control-loops: Developing Energie-balance Feed Forward signals Solving LP-drum-Level instabilities: Increasing minimum pressure IP steam. 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 12

Benefits of Thermodynamic Model (On-line) Detections of small deviations between model and real power plant Drifting measurements, fouling, leakages, performance deviations, parameters changes etc.. Examples of found deviations: Lower TIT temperatures after C inspection (retuned by the OEM); Influence of gas composition change on performance; Condenser air in-leakage and condenser fouling; Leaking of a desuperheater attemporation-valve; Leaking draining-valves fouling of compressor and inlet filters; On-line saved model data can be used in RCA s to find and analyze deviations afterwards.; or change operations or maintenance instructions. 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 13

Thermoflex (online) helps to maximize the performance The Flevo s drops less then 0,4% in relative efficiency after 50000 EOH According OEM the Relative Efficiency drops 1,7% after 8000 EOH. {not realistic??} Full savings since commissioning up to 9M (partly contributed by Thermoflex Model) 1,3 % x (50000 8000)hr x ~380MW x ~6100MJ/MWh x ~7 /GJ 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 14

Example of checking errors : Dashboard alarm!! measured power 3MW lower then expect: Increasing home load FL4 -> the model accuracy detects testing coolingwaterpumps FL5 350 337.118 339.655 Model accuracy: Load transient (<10MW/min) ± 1,0% Stable load ± 0,5% 340 335 330 325 320 315 310 300 20-8-2015 10:01:10 20-8-2015 13:13:45.82257 8.19 hours PI Measurement Thermoflex Output 20-8-2015 18:12:26 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 15

Example of measurement failure: After the mothball period the measured efficiency is too high. ThermoFlexOnline detected that the gas chromatograph was not working property. 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 16

Example of air leaking in condenser : After condenser repair the Terminal Temperature Difference is back to nominal: dt 3 C -> 1-3MW -> 300000 euro/yr. 9000 Repaired 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 17

Available software Steag (software: SR::EPOS;EBSILON). Used mainly on coal fired power plants General Physics (software: etapro). Possible Thermoflow (software: thermoflex). They are not active in this market. Advantage of combination of PI and Thermoflex / Elink Thermodynamic models of KA26 & GE9FA CCGT s in Thermoflex are available; All Engie power plants have the use op PI Processbook Lot of knowledge of CCGT s in house available also operational experience; Model development costs lower than the market and we keep the knowledge in house 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 18

Thermoflex Online Questions Scheduler? in VBA Session #2 Or if time 1. Live DEMO 2. ThermoFlex expert subjects 6 oct 2015 Nico Willems

Requirements to build an accurate model The design specifications of the plant components: Heat-exchangers, pumps, steam-turbine exhaustloss curves, glandsteam leakages, gas turbine cooling airflows, ect. OEM heat balances and correction curves: Only for starting modelling Understand the unit control logic s: gas turbine load path, fixed pressures. Check of key measurements and corrections: A control value is not always a physical value. (TAT corrections, TIT calculations, Flow calculations, static heights pressure transmitters) Gas heat input, mass flow and LHV Compressor air mass flow, Bellmouth calculation 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 20

TF standard GT26 has not enough outputs for TFO GT Data defined model 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 21

GT26 Heat balance first design 38 % of compressor flow is cooling air! 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 22

GT26 has a very complex Cooling flow system 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 23

MBH40 Cooling Flow leakages to MBH30 and MBH20 MBH20 is a mixture of Bleed and MHB40 cooling Compressor end Is cooled with OTC MBH40 air 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 24

Real: TIT s, TAT s and Pressure Ratio s TAT1 measurement Exhaust flow + part air from MBH30 Pressure drop SEV burner 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 25

Compressor maps not be available from OEM 4 Compressor maps 4 x 4 x10 = 160 tables export PI data Excel import in ThermoFlex 00/00/2015 PRESENTATION TITLE ( FOOTER CAN BE PERSONALIZED AS FOLLOW: INSERT / HEADER AND FOOTER") 26