CHAPTER 3 Development and Validation of a RP-HPLC method for Dutasteride and its impurities in bulk drug

Similar documents
International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

IJPAR Vol.6 Issue 1 Jan - Mar Journal Home page:

A NOVEL RP-HPLC METHOD FOR THE QUANTIFICATION OF ICATIBANT IN FORMULATIONS

A VALIDATED STABILITY-INDICATING RP-HPLC ASSAY METHOD FOR BOLDENONE UNDECYLENATE AND ITS RELATED SUBSTANCES

International Journal of Generic Drugs ANALYTICAL METHOD PROCEDURES THIS SOP IS 'SWITCHED : OFF : ON'

Extended Application Note

International Journal of Research and Development in Pharmacy and Life Sciences. Research Article

FRANZ CELL TEST OF NANO GLUTATHIONE WITH HPLC ANALYSIS

Int. Res J Pharm. App Sci., 2012; 2(6): ISSN:

Trace-Level Analysis of Metanephrines in Plasma by HILIC LC-MS/MS

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

Research Article A Validated Method Development of Dutasteride in Human Plasma Using LC-MS/MS

Analysis of Benzenesulfonic Acid and P-Toluenesufonic Acid Esters in Genotox Monitoring using UPLC/UV-MS

Analysis of Melamine and Cyanuric Acid in Food Matrices by LC-MS/MS

Chemical Analysis for Methyltestosterone

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

The instrument should have a mass range from 2 to 2000 m/z or better Interface

SIMPLE, EFFICIENT AND SIMULTANEOUS DETERMINATION OF ANABOLIC STEROIDS IN HUMAN URINE

Simultaneous Determination of a Panel of 22 Steroids in Urine and Serum by SPE and LC-MS/MS

High speed UHPLC-MS/MS determination of multiple steroids in human serum using the Nexera MX system for multiplex analysis

SOP: Derivatized testosterone_01 Revision: 01 Date Effective: 05/17/15

Evaluation of linear and step gradient performance and retention time precision of the Agilent 1200 Series Rapid Resolution LC

Fast method for Ginseng Analyses using Agilent Poroshell 120 Columns Scaled from a Traditional Method

May 1, By John Heim,Doug Staples

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION

Sensitive Analysis of Genotoxins by HPLC-ECD Using Boron-Doped Diamond Electrochemical Cell

Development of a Clinical Research Method for the Measurement of Testosterone. Dihydrotestosterone

Improved Performance in Capillary Electrophoresis using Internal Standards

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

More Speed and Resolution for Current Methods

CORESTA RECOMMENDED METHOD Nº 67

WADA Technical Document TD2014EAAS. Endogenous Anabolic Androgenic Steroids Measurement and Reporting

APPLICATION NOTE. GC Integrated Permeation Device

GCMSD-Headspace Analysis SOP

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

Dissolution test results showing biorelevant media made from SIF Powder Original is the same as media prepared using methylene chloride

The Application of QuEChERS in the Extraction of Anabolic Steroids in Whole Blood

GUIDE TO ULTRA-FAST HPLC. Quick Tips for Converting Conventional Reversed-Phase HPLC Separations to Ultra-Fast Separations

Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs

LCMSMS Solutions For Steroid Analysis

Svensk läkemedelsstandard

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

(2 pts) Draw the line of best fit through the data and estimate the concentration of Fe in your sample solution.

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay

Agilent 1290 Infinity LC System Applications requiring the Agilent Ultra-Low Dispersion Kit

EFFECTS OF REVIVOGEN SCALP THERAPY ON TESTOSTERONE METABOLISM IN RECONSTRUCTED HUMAN EPIDERMIS

TESTOSTERONE AND ESTERS* Latest Revision: June 23, 2005

Setting a New Standard in Flash Chromatography Performance

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

DEVELOPMENT AND VALIDATION OF RP HPLC METHOD TO DETERMINE NANDROLONE PHENYLPROPIONATE IN DIFFERENT PHARMACEUTICAL FORMULATIONS

Natural Hair Transplant Medical Center, Inc Dove Street, Suite #250, Newport Beach, CA Phone

Gas chromatographic determination of 1,4-dioxane at the

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

RP-HPLC Method Development and Validation for Nitroxynil in Active Pharmaceutical Ingredient Manufacturing.

Rapid and Reliable Detection of Dissolved Gases in Water

Retention Time Locking: Concepts and Applications. Application

Synthesis, Isolation, and Characterization of Isomeric Impurity of Dutasteride.

Development of DMS and Acetonitrile, and Formaldehyde gas standards. Gwi Suk Heo, Yong Doo Kim, Mi-Eon Kim, and Hyunjin Jin

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

Integration of amino acid, acylcarnitine and steroids analysis in single FIA/LC-MS/MS platform

Syed Ghulam Musharraf 1,2* and Umair Gulzar 2

SOP: Buck Scientific BLC-20P HPLC Operation

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Technical Procedure for Drug Chemistry Gas Chromatograph/Mass Spectrometry (GC-MS)

Increasing the productivity of ICP-OES with the Thermo Scientific Qtegra ISDS Software

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

STD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015

LEVANT WORMSEED FOR HOMOEOPATHIC PREPARATIONS CINA FOR HOMOEOPATHIC PREPARATIONS

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

STUDY OF THE EFFECT OF AN EXTRACT OF Serenoa repens on the production of the 5-α reductasa enzyme

ISO INTERNATIONAL STANDARD

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

CHE 4115 Chemical Processes Laboratory 2 Experiment 1. Batch Distillation

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

AKTA pure 25 New Owner s Intro

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Introduction. Experimental

Analysis of Melamine and Cyanuric Acid in Food Matrices by LC-MS/MS

Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Copyrights: Restek Corporation

Now it is. easy to switch. CHS TM Steroid Profiling kit and software. Brochure not for distribution in the USA and Canada

Precisely HPLC. Hints, Tips, Guidelines and Important Considerations. Presenters: Wilhad Reuter / Tom Breslin

EFFECTS OF CLEAROGEN ACNE LOTION ON TESTOSTERONE METABOLISM IN RECONSTRUCTED HUMAN EPIDERMIS

Determination of Selected ASTM Perfluorinated Compounds (PFCs) Using the Shimadzu LCMS No. LCMS-083. No. SSI-LCMS-083

MSD 96-Well MULTI-ARRAY Human (6E10) Abeta 40 Ultra-Sensitive Kit

Experiment GC : Analysis of BTEX by GC-FID

LUMAZOTE T ECHNICAL BRO CHU RE

DOS in Food Science & Nutrition, Manasagangotri, Mysore

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Background Statement for SEMI Draft document 4657B NEW STANDARD: SPECIFICATIONS FOR TUNGSTEN HEXAFLUORIDE (WF 6 )

M0BCore Safety Profile. Pharmaceutical form(s)/strength: 5 mg SE/H/PSUR/0002/006 Date of FAR:

Agilent Dimension Software for ELSD User Manual

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Renzo BAGNATI Mario Negri Institute of Pharmacological Research- IRCCS Milano - Italy

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

Automated Determination of Dissolved Gases in Water Anne Jurek

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

Transcription:

CHAPTER 3 Development and Validation of a RP-HPLC method for Dutasteride and its impurities in bulk drug Chapter-3 Page 101

3.1. INTRODUCTION This chapter describes the method development and validation of a RP-HPLC method for Dutasteride and its impurities in bulk drug. Active ingredients therapeutic activity, review of literature, materials and methods, development trials, validation results and summary and conclusion were covered. Dutasteride has the chemical name (5α, 17β)-N-{2,5 bis(trifluoromethyl) phenyl}-3-oxo-4-azaandrost-1-ene-17-carboxamide. It is a white solid substance with a molecular formula of C27H30N2F6O2. Dutasteride is a dual 5-α reductase inhibitor that inhibits conversion of testosterone to dihydrotestosterone (DHT). Dutasteride is FDA approved for treatment of benign prostatic hyperplasia (BPH) and is also prescribed off-label for treatment of male pattern baldness (MPB). Dutasteride is approved for the treatment of benign prostatic hyperplasia (BPH) (also known as enlarged prostate). The teratogenic effect (abnormalities of physiological development) from dutasteride is harmful to male children. Women who are pregnant should not handle the capsules, as inadvertent consumption, such as skin contact, could cause birth defects of the male fetus. The adverse effects would be similar to 5-alphareductase deficiency, where a developing male child is naturally deficient in 5-alpha reductase type II, and thus unable to synthesize it. As Dutasteride blocks the same process, developing males would have a DHT deficiency with its adverse effects as a result of the drug. Men who are taking dutasteride should not donate blood, and due to its long half-life, should also not donate blood for at least 6 months after the cessation of treatment. These precautions are to be taken in order to prevent the potential risk of causing birth defects in a pregnant woman who receives a transfusion with blood that contains Dutasteride. Analytical HPLC method has been developed for Dutasteride (1-7) and impurities. Many HPLC, LC-MS and HPTLC methods are observed in publications Chapter-3 Page 102

during method development, some of the methods are mentioned by LC-MS for blood samples and Serum samples. An HPLC method was developed for Dutasteride and impurities. Figure-3.1: Structure of Dutasteride. Chemical name : (5α, 17β)-N-{2,5 bis(trifluoromethyl) phenyl}-3-oxo-4-azaandrost-1-ene-17- carboxamide CAS Registry Number : Molecular formula : 164656-23-9 C27H30N2F6O2 Molecular weight : 528.58 Therapeutic category : benign prostatic hyperplasia (BPH) Table- 3.1: Dutasteride impurities details: S. No Impurity structure Chemical name Molecular weight Impurity-1 Chapter-3 Page 103

COOH 3-oxo-4-aza-5α-androst-1-317.42 ene-17β carboxylic acid C19H27NO3 O N H Impurity-2 O H N CF 3 17β-N-[2,5-bis O N H F 3 C (trifluoromethyl)phen yl]carbamoyl-3- hydroxy-4-azaestra- 508.46 C26H22 F6N2O2 1,3,5,7,9-pentaene Impurity-3 O N H F 3C NH CF 3 O 17α-N-[2,5-bis (trifluoromethyl)phen yl]carbamoyl-4-aza- 5α-androst-1-en-3-one 528.53 C27H30 F6N2O2 3.2. REVIEW OF LITERATURE A simple, rapid, sensitive and specific liquid chromatography tandem mass spectrometry method was developed and validated for quantification of dutasteride (I), a potent and the first specific dual inhibitor of 5_-reductase, in human plasma. The analyte and internal standard (finasteride (II)) were extracted by liquid liquid extraction with diethyl ether/ dichloromethane (70/30, v/v) using a Glas-Col Multi- Pulse Vortexer. The Chromatographic separation was performed on a reverse phase Xterra MS C18 column with a mobile phase of 10mM ammonium formate/acetonitrile (15/85, v/v, ph adjusted to 3.0 with formic acid). The protonated analyte was quantitated in positive ionization by multiple reaction Chapter-3 Page 104

monitoring with a mass spectrometer. The mass transitions m/z 529.5 to 461.5 and m/z 373.3 to 317.4 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.1 25.0 ng/ml(nano grams/milliliter) for dutasteride in human plasma. The lower limit of quantitation was 100 pg/ml(pico grams/milliliter) with a relative standard deviation less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 1.2 min for each sample made it possible to analyze a through put of more than 400 human plasma samples/ day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. The chromatography was on Waters Xterra MS C18 column (3.5µm, 50mm 3mm I.D.) at 30 C temperature. The mobile phase composition was a mixture of 10mM ammonium formate buffer/acetonitrile (15/85, v/v, ph adjusted to 3.0 with formic acid), which was pumped at a flow-rate of 0.6 ml/min. A simple, sensitive and precise RP-HPLC method was developed for the determination of dutasteride in tablet dosage form. The RP-HPLC separation was achieved on phenomenex C18 column (250 mm, ID 4.6 mm, 5 μm) using mobile phase methanol: water (90:10 v/v) at a flow rate of 1 ml/min at an ambient temperature. Quantification was achieved with photodiode array detection at 235 nm over the concentration range 1-12 μg/ml. The method was validated statistically and was applied successfully for the determination of dutasteride in tablets. Drug was retained in mobile phase consisting of acetonitrile: water (60: 40, v/v) and methanol: water (60: 40, v/v). In acetonitrile: water (90: 10, v/v) tailing in the peak was observed. Good peak symmetry and satisfactory retention time was obtained with mobile phase consisting of methanol: water (90: 10 v/v). Quantification was achieved with PDA detection at 235 nm based on peak area. The retention time of DTS obtained was 5.24±0.112. The system suitability tests for HPLC were carried out on freshly prepared solution of DTS (10 μg/ml). A simple, rapid, specific and sensitive Reverse Phase-HPLC method has been developed and validated for the simultaneous estimation of alfuzosin hydrochloride Chapter-3 Page 105

(ALF) and dutasteride (DUTA) in bulk powder and pharmaceutical dosage form. The RP-HPLC separation was performed on HiQ Sil C18HS column (4.6mm I.D. X 250 mm) using mobile phase methanol: water (90:10 v/v) at a flow rate of 1 ml/min at an ambient temperature. Quantitation by HPLC was achieved with UV detection at 244 nm based on peak area with linear calibration curves at concentration ranges 1-5 μg/ml and 4-20 μg/ml for ALF and DUTA, respectively. The limit of detections (LOD) was 0.2 μg/ml and 1 μg/ml for ALF and DUTA, respectively. The method was validated for linearity, accuracy, specificity, precision, robustness and recovery as per ICH guidelines. The method was applied for analysis of pharmaceutical dosage form and no chromatographic interference from the tablet excipients was found. Statistical data reveals that the method is accurate, repeatable and selective for the simultaneous quantitation of the above drugs in pharmaceutical dosage form and for routine analysis of raw material of drugs in quality control laboratories. Different ratios of methanol and water were tried but it was found that methanol: water in the ratio 90: 10 (v/v) at flow rate of 1 ml/min gives acceptable retention time (tr) of 6.2 min and 4.8 min for ALF and DUTA respectively. The mixed standard stock solution (10 μg/ml each of ALF and DUTA) was injected in system. The detection wavelength, 244 nm, was selected from overlain spectra of the drugs acquired form UV spectrophotometer. 3.3. OBJECTIVE The main objective of this research work is to develop simple, accurate and stability indicating RP-HPLC method for the quantification of impurities in Dutasteride. Review of literature reveals that the reported methods were qualitative and instrument methods with high analysis time and no quantification of impurities. Development and Validation of a RP-HPLC method for Dutasteride and its impurities in bulk drug. 3.4.1. Reagents & Chemicals. 3.4. MATERIALS AND METHODS Chapter-3 Page 106

a. Water : Rankem b. Acetonitrile HPLC GRADE : Rankem c. Potassium dihydrogen ortho phoshate : Rankem d. Potassium hydroxide : Rankem 3.4.2. Drug Substances: Dutasteride, impurity-1, impurity-2 and impurity-3 are gift samples received from Lupin Ltd., India. 3.4.3. Instrument details: The High Performance Liquid Chromatography using waters HPLC instrument having quaternary pumps including auto injector. This HPLC connected with PDA detector, make Waters instrument. All the components are controlled with Empower2 software. 3.4.4. Method development: Development trials were performed with all neutral buffer salts and different make HPLC columns but finally the chromatographic conditions were optimized with the potassium di potassium orthophoshate, acetonitrile, and water with simple isocratic method. 3.4.4.1 Wave length Selection: The UV spectrums were generated for Dutasteride, impurity-1, impurity-2 and impurity-3 using with Photo diode array detector (PDA). Dutasteride and its impurities were found to have varying absorption maxima over a range of wavelength. But it was found that at about 210 nm, Dutasteride and its impurities were found to have optimum UV absorption. Therefore, 210 nm was selected for the study and Quantification of Dutasteride and it s related impurities. Chapter-3 Page 107

Figure- 3.2: UV Spectra of Dutasteride. Figure- 3.3: UV Spectra of impurity-1. Figure- 3.4: UV Spectra of impurity-2. Chapter-3 Page 108

Figure- 3.5: UV Spectra of impurity-3. 3.4.4.2. Selection of mobile phase and stationary phase: Dutasteride, impurity-1, impurity-2 and impurity-3 were found that different functional groups, shows different affinities with mobile phases and stationary phase. A different column with different selectivity provides good separation for method development. Two parameters were chosen to get required resolutions, separations and symmetrical peaks for Dutasteride and impurities. i.e., Selection of the mobile phase and column. 3.4.4.3. Selection of Mobile phase: Impurity-1, impurity-2 and impurity-3 were co-eluted using with different mobile phases. Dutasteride is steride derivative and the impurities of Dutasteride were having wide range of polarities and the separation of these impurities mainly depends on the column stationary phase. An isocratic method was mobile phase of buffer 0.01 di potassium dihydrogen phoshate in water ph adjusted to 4.5 and acetonitrile was suitable for the separation of Dutasteride and its related substances. Mobile phase was degassed and filtered through 0.22µm millipore filter paper. 3.4.4.4. Selection of stationary phase: Separation was achieved with Zorbax CN, 250 x 4.6mm,I.D., 5.0µm column. Different stationary phases were studied for the separation of Dutasteride such as Chapter-3 Page 109

C8 and C18 using the mobile phase specified. The experimentation was started using Zorbax C18 250 X 4.6 mm, I.D., 5.0µm column. Trail-1: The complete experiment details are as follows. Column Mobile phase-a Sample preparation Wavelength Flow rate Run time Injection volume Oven temperature Diluent Elution : Zorbax C18 250 X 4.6 mm,i.d., 5.0 µm column : Buffer and acetonitrile in the ratio of 50:50(v/v) : 5 mg in 10 ml of diluent : 210 nm : 1.0 ml/min : 26min : 20µL : 40 o C : Water and acetonitrile in the ratio of 8:2 Isocratic Figure- 3.6: Typical HPLC Chromatogram of Dutasteride using Zorbax C18 250 X 4.6 mm I.D., 5.0µm column. Observation: Dutasteride and impurity-3 are not separated while impurity-1 and impurity-2 are separated. Hence, Zorbax C18 250 X 4.6 mm I.D., 5.0µm column is not suitable for the separation of Dutasteride and impurity-3. Trail-2: The complete experiment details are as follows. Chapter-3 Page 110

Column Mobile phase Sample preparation Wavelength Flow rate Run time Injection volume Oven temperature : Zorbax C8 250 X 4.6 mm I.D., 5.0µm column : Buffer and acetonitrile in the ratio of 40:60(v/v) : 5 mg in 10 ml of diluent : 210 nm : 1.2 ml/ min : 35min : 20µL : 45 o C Diluent Elution : : Water and acetonitrile in the ratio of 2:8 Isocratic Figure- 3.7: Typical HPLC Chromatogram of Dutasteride using Zorbax C8 250 X 4.6 mm, I.D., 5.0µm column. Observation:Impurity-1 and impurity-2 are separated while Dutasteride and impurity-3 are coeluting each other. Hence, Zorbax C8 column is not suitable for the separation of Dutasteride and impurity-3. Trail-3: The complete experiment details are as follows. Column : Zorbax CN 250 X 4.6 mm,i.d., 5.0µm column Chapter-3 Page 111

Mobile Phase Sample preparation Wavelength Flow rate Oven temperature Diluent Elution Injection volume Runtime : Buffer and acetonitrile in the ratio of 50:50 v/v : 5 mg in 10 ml of diluent : 210 nm : 1.0 ml/ min : 40 o C : Water and acetonitrile in the ratio of 2:8 : Isocratic : 20µL : 35 min Figure- 3.8: Typical HPLC Chromatogram of Dutasteride using Zorbax CN Column. Observation: Dutasteride and impurity-3 are not resolved base line separation. Hence, CN column is suitable for the separation of Dutasteride and impurity-3. Need to change solvent and buffer ratio for better separation. Trail-4: The complete experiment details are as follows. Column : Zorbax CN 250 x 4.6mm,I.D., 5.0µm column Mobile phase Sample preparation : Buffer and acetonitrile in the ratio of 60:40 v/v : 5 mg in 10 ml of diluent Wavelength Run time : : 210 nm 35min Chapter-3 Page 112

Injection volume : 20µL Flow rate Column temperature : 1.2 ml/ min : 40 o C Figure- 3.9: Typical HPLC Chromatogram of Dutasteride using Zorbax CN column and trail-4 method conditions. Observation: Impurity-1, impurity-2, Dutasteride and impurity-3 were separated very well. Hence, Zorbax CN 250 x 4.6mm,I.D., 5.0µm column is suitable for separation of all impurities and Dutasteride. Conclusion: Based on the above study on stationary phase, it was concluded that impurity-1, impurity-2, Dutasteride and impurity-3 were well separated from each other in column Zorbax CN 250 X 4.6mm,I.D., 5.0µm column. 3.4. 5. Optimized method: Based on the above study, the below mentioned HPLC parameters was chosen for the separation and Quantification of impurity-1, impurity-2, Dutasteride and impurity-3. Column : Zorbax CN 250 X 4.6 mm,i.d., 5.0µm column Buffer preparation : 0.01M potassium dihydrogen ortho phoshate in water Mobile phase Sample preparation : : ph adjusted to 4.5 with dil. H3PO4 Mix buffer and acetonitrile in the ratio of 40:60 5 mg in 10 ml of diluent Chapter-3 Page 113

Wavelength : 210 nm Flow rate : 1.2 ml/min Oven temperature : 40 o C Run time : 35min Diluent : Water and acetonitrile in the ratio of 2:8 Injection volume : 20 µl a) Preparation of impurity-1 stock solution: Transferred 5mg of impurity-1 in to 10 ml volumetric flask, dissolved and diluted to volume with diluent. b) Preparation of impurity-2 stock solution: Weighed accurately 5mg of impurity-2 into 10 ml volumetric flask, dissolved and diluted to volume with diluent. c) Preparation of impurity-3 stock solution: 5mg of impurity-3, transferred into 10 ml volumetric flask, dissolved and diluted to volume with diluent. d) Preparation of Sample solution: Transferred 5mg of sample into 10mL volumetric flask, dissolved and diluted to volume with diluent. e) Preparation of system suitability solution : Weighed accurately 5mg of standard into 10 ml volumetric flask, dissolved in 5 ml of diluent and added 75µL of each impurity stock solution dissolved and diluted to volume with diluent. Procedure: After equbilrated the column, separately injected 20µL of diluent as a blank, system suitability solution, 20µL of standard solution and test solution in the Liquid Chromatograph. Eliminate peaks due to the blank. System suitability criteria: The resolution between Dutasteride and impurity-3 from system suitability solution should be not less than 2.0. The tailing factor for Dutasteride should be not more than 2.0. The number of theoretical plates for Dutasteride should be not less than 3000. Table -3.2: Specification: S.No Name of the impurity Specification 01 Impurity-1 Not more than 0.15% Chapter-3 Page 114

02 Impurity-2 Not more than 0.15% 03 Impurity-3 Not more than 0.15% 04 Any other impurity Not more than 0.10% 05 Total impurities Not more than 0.50% Calculation: calculate the impurity using below formula Known impurities: % area obtained for known impurity /RRF Total impurities: % known impurities + % other unknown impurities calculated by area normalization. RRF for Impurity-1: 0.92 RRF for Impurity-2: 1.37 RRF for Impurity-3: 0.74 3.5. RESULTS AND DISCUSSION 3.5.1. Method validation: Analytical method validation was performed as per ICH (8-10) and USFDA guidelines with specificity, precision, accuracy, linearity, limit of detection, limit of quantification, ruggedness and robustness. 3.5.1.1. Related substances by HPLC: 3.5.1.2. System suitability: a) Preparation of impurity-1 stock solution: Transferred 5mg of impurity-1 into a 10 ml volumetric flask, dissolved and diluted to volume with diluent. b) Preparation of impurity-2 stock solution: Transferred 5 mg of impurity-2 into a 10 ml volumetric flask, dissolved and diluted to volume with diluent. c) Preparation of Sample solution: Weighed accurately 5mg of sample into a 10mL volumetric flask, dissolved and diluted to volume with diluent. d) Preparation of sample + all impurities spiked : Transferred 5mg of sample into a 10 ml volumetric flask, dissolved in 5mL of diluent and added 10µL of each impurity stock solution dissolved and diluted to volume with diluent. Chapter-3 Page 115

Injected all above solutions once and calculated the system suitability parameters i.e., the resolution between adjacent peaks, Tailing factor and tangent for each impurity. Conclusion: Under optimized Chromatographic conditions, impurity-1, impurity-2, impurity-3 and Dutasteride were separated well, retention times being about 3.83, 12.18, 15.9 and 13.9 min respectively. The system suitability results are given in table - 3.3. Table- 3.3: System suitability results: S. No Name Retention Relative Resolution, Theoretical Tailing time (min) retention time (Rs) plates ( N) factor (T) (min) 01 Impurity-1 3.83 0.29 --- 3604 1.1 02 Impurity-2 12.18 0.24 10.2 1317 1.06 03 Dutasteride 13.9 1.00 3.1 14878 1.1 04 Impurity-3 15.9 1.14 3.5 --- --- 3.5.1.3. Specificity: a) Acid hydrolysis: Dissolved 50mg of sample in 50mL of 5N HCl solution and kept for 24 hours at 60 C with continuous stirring and analysed after 24 hours. Observation: Dutasteride sample was stable under acid hydrolysis. b) Base hydrolysis: Dissolved 50mg of sample in 50mL of 0.1N NaOH solution and kept for 8 hours at 60 C with continuous stirring and analysed after 8 hours. Observation: Dutasteride was degraded under base hydrolysis. c) Oxidation degradation: Dissolved 50mg of sample in 50mL of 0.01% peroxide solution and kept for 3 hours at 60 C with continuous stirring and analysed after 1 hour. Observation: Dutasteride was stable under peroxide solution. Chapter-3 Page 116

d) Thermal degradation: About 1 gm of Dutasteride sample is taken and kept under thermal condition i.e., at 105 C for 7days and sample collected after 48 hours and sample analyzed. Observation: Dutasteride sample is stable under thermal condition. e) Photo degradation: About 1gm of sample is taken and kept in UV chamber i.e., at 254 nm for 48 hours and sample collected after 48 hours and sample analyzed. Observation: Dutasteride sample is stable under photo condition. f) Water hydrolysis: Dissolved 50mg of sample in 100mL of water and kept for 24 hours at 70 C with continuous stirring and injected after 24 hours. Observation: Dutasteride was not degraded under water hydrolysis. Conclusion: Dutasteride samples are stable in thermal, photo degradation, acid hydrolysis, peroxide and water hydrolysis. Dutasteride was degraded under base hydrolysis. All samples are analyzed and found that degradation peaks are separated from known impurities and Dutasteride. Peak purity were established with PDA detector and proved that Dutasteride peak is pure in all above conditions. The studies are summarized in table 3.4. Table- 3.4: Dutasteride degradation data: Stressed condition Time (hrs) % Purity As such Initial 99.95 Acid hydrolysis 24 99.4 Base hydrolysis 8 94.1 Oxidation degradation 3 99.86 Thermal degradation 7 x 24 99.92 Photo degradation 48 99.63 Water hydrolysis 24 99.86 Chapter-3 Page 117

Figure- 3.10: A typical HPLC Chromatogram of acid degradation sample. Figure 3.11: A typical HPLC Chromatogram of base degradation sample. Figure- 3.12: A typical HPLC Chromatogram of oxidation degradation sample. Chapter-3 Page 118

Figure- 3.13: A typical HPLC Chromatogram of thermal degradation sample. Figure- 3.14: A typical HPLC Chromatogram of photo degradation sample. Figure- 3.15: A typical HPLC Chromatogram of water degradation sample. Chapter-3 Page 119

3.5.1.4. Limit of Detection and Limit of Quantification: a) LOD/LOQ solution-1 preparation (0.05%): Transferred 5µL of each impurity stock solutions into 10 ml volumetric flask, dissolved and diluted to volume with diluent. b) LOQ solution-2 preparation:transferred 4.0µL of impurity-1, 7.0µL of impurity-2 and 7.5 µl of impurity-3 stock solutions into 10 ml volumetric flask, dissolved and diluted to volume with diluent. c) LOD solution-1 preparation: Transferred 3.3mL of above LOQ solution-2 stock solutions into 10mL volumetric flask, dissolved and diluted to volume with diluent. Injected all above solutions and calculated the Limit of Detection and Limit of Quantification for each impurity. Conclusion: The LOD for impurity -1, impurity -2 and impurity-3 were found to be 0.0110 %, 0.022% and 0.023% respectively. The LOQ for impurity -1, impurity -2 and impurity-3 were found to be 0.04 %, 0.07% and 0.075 % respectively. The results are summarized in table - 3.5. Table- 3.5: Limit of Detection and Limit of Quantification data: Conc. Impurity -1 Impurity -2 Impurity-3 LOD 0.0110 0.022 0.023 LOQ 0.040 0.070 0.075 3.5.1.5. Precision and accuracy at Limit of Quantification level: a) Solution preparation: Transferred 40µL of impurity-1, 70µL of impurity-2 and 75µL of impurity-3 into 100mL volumetric flask, containing 50 ml of diluent dissolved and diluted to volume with diluent. Prepared six times the solution as mentioned above and injected all the above solutions each preparation once, calculated the % RSD for six preparations for each impurity. Chapter-3 Page 120

Accuracy: b) Sample + All impurities Solution preparation: Transferred 50mg of sample into 100mL volumetric flask, dissolved in 50mL of diluent and added 40µL of impurity-1, 70µL of impurity-2 and 75µL of impurity-3 dissolved and diluted to volume with diluent. c) Sample solution preparation: Transferred 50mg of sample into 100mL volumetric flask, dissolved and diluted to volume with diluent. Prepared three times the solution as mentioned above and injected each preparation once to calculate the % recovery for each impurity at Limit of Quantification level. Conclusion: The repeatability and recovery the LOQ concentrations for impurity-1, impurity-2 and impurity-3 were 3.40%, 1.98% 1.62 % and 98.60%, 103.60%, 103.00% respectively. The results are summarized in the table - 3.6. Table- 3.6: Precision and accuracy at Limit of Quantification level data: S. No Impurity % RSD (n=6) % Recovery (n=3) 1 Impurity-1 3.40 98.60 2 Impurity-2 1.98 103.60 3 Impurity-3 1.62 103.00 3.5.1.6. Linearity: a) Linearity solution-1(0.075%): 7.5µL of each impurity transferred into 10mL volumetric flask, containing 5 ml of diluent dissolved and diluted to volume with diluent. b) Linearity solution-2(0.1125%): 11.25µL of each impurity transferred into 10mL volumetric flask, containing 5 ml of diluent dissolved and diluted to volume with diluent. c) Linearity solution-3(0.15%): 15µL of each impurity transferred into 10mL volumetric flask, containing 5 ml of diluent dissolved and diluted to volume with diluent. Chapter-3 Page 121

d) Linearity solution-4(0.1875%): 18.75µL of each impurity transferred into 10mL volumetric flask, containing 5 ml of diluent dissolved and diluted to volume with diluent. e) Linearity solution-5(0.225%): 22.5µL of each impurity transferred into 10mL volumetric flask, containing 5 ml of diluent dissolved and diluted to volume with diluent. Injected all above solutions each preparation once and calculated the Linearity parameters i.e. correlation coefficient, slope and intercept for each impurity. Conclusion: Linearity established for impurity-1, impurity-2 and impurity-3 at 0.075%, 0.1125%, 0.15%, 0.1875%, 0.225%. The correlation coefficient (r) are more than 0.99. The above result reveal that method is linear results are summarized in purity wise table -3.7. Table- 3.7: Dutasteride impurity-1 linearity data: S. No Level (%) Concentration (%) Area of impurity-1 1 50 0.075 8898 2 75 0.1125 12656 3 100 0.15 16959 4 125 0.1875 21542 5 150 0.225 25992 Correlation coefficient(r) 0.9993 Slope 114864 Y-Intercept -20.2 (%)Y-Intercept -0.119 Chapter-3 Page 122

Figure- 3.16: Dutasteride impurity-1 linearity graph. Table- 3.8: Dutasteride impurity-2 linearity data: S. No Level (%) Concentration (%) Area of impurity-2 1 50 0.075 6400 2 75 0.1125 9284 3 100 0.15 12980 4 125 0.1875 16220 5 150 0.225 19540 Correlation coefficient(r) 0.9995 Slope 88576 Y-Intercept -401.6 (%)Y-Intercept -3.09 Chapter-3 Page 123

Figure- 3.17:Dutasteride impurity-2 linearity graph. Table- 3.9: Dutasteride impurity-3 linearity data: S. No Level (%) Concentration (%) Area of impurity-3 1 50 0.075 12200 2 75 0.1125 18587 3 100 0.15 24520 4 125 0.1875 30234 5 150 0.225 36567 Correlation coefficient(r) 0.9998 Slope 161016 Y-Intercept 269.2 (%)Y-Intercept 1.09 Chapter-3 Page 124

Figure- 3.18: Dutasteride impurity-3 linearity graph. 3.5.1.7. Accuracy: a) Accuracy solution-1 preparation (0.075%): Weighed accurately 5mg of sample into 10 ml volumetric flask, dissolved in 5mL of diluent and added 7.5µL of each impurity stock solution, dissolved and diluted to volume with diluent. Three solutions prepared as mentioned above. b) Accuracy solution-2 preparation- (0.15%): Weighed accurately 5 mg of sample into 10 ml volumetric flask, dissolved in 5mL of diluent and added 15µL of each impurity stock solution, dissolved and diluted to volume with diluent. Three solutions prepared as mentioned above. c) Accuracy solution-3 preparation (0.225%): Weighed about 10mg of sample into 10 ml volumetric flask, dissolved in 5mL of diluent and added 22.5µL of each impurity stock solution, dissolved and diluted to volume with diluent. Three solutions prepared as mentioned above. Injected each above preparation once and calculated the recovery for each impurity at each level. Conclusion: The percentage recovery of all three impurities in Dutasteride samples is shown in the table- 3.10. Chapter-3 Page 125

Table- 3.10: % Recovery in accuracy: Concentration Impurity-1(%) Impurity-2(%) Impurity-3(%) 50% 101.45 97.32 102.11 100% 96.61 102.19 99.10 150% 97.79 95.59 96.10 3.5.1.8. Precision: a) Sample preparation: About 10mg of sample into 10mL volumetric flask, dissolved and diluted to volume with diluent. b) Sample + 0.10% spiked preparation: Transferred 10mg of sample into 10mL volumetric flask, dissolved in 5mL of diluent added 10µL of each impurity stock solution dissolved and diluted to volume with diluent. Prepared the solution six times as mentioned above. Injected all above sample preparations and calculated the % RSD for each impurity. Results and discussion: The precision of the related substance method was checked by injecting six individual preparations of Dutasteride spiked with 0.10% of impurity-1, impurity-2 and impurity-3. The % RSD of the area for each of impurity-1, impurity-2 and impurity-3 were calculated. The results were summarized in the table 3.11. Table- 3.11: Precision data: Name Impurity-1 Impurity-2 Impurity-3 % RSD 3.40 1.98 1.62 3.5.1.9. Robustness: Flow variation: a) Sample solution preparation: About 5mg of sample into 10mL volumetric flask, dissolved and diluted to volume with diluent. Chapter-3 Page 126

b) Sample + 0.10% spiked preparation: About 5mg of sample into 10mL volumetric flask, dissolved in 5mL of diluent added 10µL of each impurity stock solution dissolved and diluted to volume with diluent. Injected the above sample solution at flow rates 1.0mL/min and at 1.4mL/min and observed the system suitability parameters and impurities relative retention times and compared with 1.2mL/min results. Temperature variation: a) Sample solution preparation: Transferred 5mg of sample into 10mL volumetric flask, dissolved and diluted to volume with diluent. b) Sample + 0.10% spiked preparation: Transferred 5mg of sample into 10mL volumetric flask, dissolved in 5mL of diluent added 10µL of each impurity stock solution dissolved and diluted to volume with diluent. Injected the above sample solution at temperature 35 C and at 45 C and observed the system suitability parameters and impurities relative retention times and compared with 40 C results. Conclusion: The results are summarized in the table- 3.12. Table- 3.12: Robustness data: Parameter 35 C 45 C 1.2 1.4 As such ml/min ml/min Impurity 1 RRT 0.28 0.31 0.29 0.29 0.29 Impurity 2 RRT 0.23 0.25 0.24 0.24 0.24 Impurity 3 RRT 0.23 0.25 0.24 0.24 0.24 Theoretical plates for 12363 11614 13282 12084 14878 Dutasteride Tailing factor for Dutasteride Resolution between Impurity-2,3 and Dutasteride 1.3 1.3 1.2 1.2 1.2 2.4 2.2 2.5 2.2 2.4 Chapter-3 Page 127

3.5.1.10. Solution stability: Sample solution preparation: Weighed accurately 5 mg of sample into 10 ml volumetric flask, dissolved and diluted to volume with diluent. Injected the solution for 0 hrs(sample solution initial), 12hrs, 24 hrs and 48 hrs and performed the impurity content. Conclusion: Impurity-1, and impurity-2 is not increased and other impurities are also not observed during the solution stability and mobile phase stability experiments when performed using the related substance method. The solution stability and mobile phase stability experiment data confirms that the sample solutions and mobile phases used during the related substance determination were stable for at least 48 hours. The results are summarized in the table- 3.13. Table- 3.13: Solution stability data: Duration Impurity-1 (%) Sample solution initial Impurity-2 (%) Impurity-3 (%) Any other Total impurity (%) impurities (%) 0.01 Not detected Not detected 0.01 0.02 After 12 hrs 0.01 Not detected Not detected 0.01 0.02 After 24 hrs 0.01 Not detected Not detected 0.01 0.02 After 48 hrs 0.01 Not detected Not detected 0.01 0.02 Table- 3.14: Mobile phase stability data: Duration Impurity-1 (%) Sample solution initial Impurity-2 (%) Impurity-3 (%) Any other impurity (%) Total impurities (%) 0.01 Not detected Not detected 0.01 0.02 After 12 hrs 0.01 Not detected Not detected 0.01 0.02 After 24 hrs 0.01 Not detected Not detected 0.01 0.02 After 48 hrs 0.01 Not detected Not detected 0.01 0.02 Chapter-3 Page 128

3.5.1.11. Batch analysis: Using the above validated method, Dutasteride sample was analyzed and the data is furnished in table 3.15. Table- 3.15: Batch analysis data: Lot Number Impurity-1 Impurity-2 Impurity-3 Any other impurity Total impurities 001 0.01 0.01 Not detected 0.01 0.03 3.6. SUMMARY ANDCONCLUSION The present study describes the development of reversed phase liquid chromatographic (RPLC) method for Dutasteride in the presence of its impurities. successful separation of Dutasteride from the synthetic impurities achieved on a Inertsil CN, 250X4.6mm ID., 5.0µm column. The developed HPLC method was validated with respect to linearity, accuracy, precision, specificity and ruggedness. To ensure the quality of Dutasteride. To the best of our knowledge, validated stability indicating Liquid Chromatography method which separates all the impurities disclosed in this investigation was not studied elsewhere. This method can be used for routine analysis of production samples in bulk drugs. Chapter-3 Page 129

3.7. REFERENCES 1. N.V.S. Ramakrishna, K.N. Vishwottam, S. Puran, M. Koteshwara, S. Manoj, M Santosh.Selective and rapid liquid chromatography tandem mass spectrometry assay of dutasteride in human plasma, Journal of Chromatography B, 809(2004) 117 124. 2. Dipti B. Paterl, N.J.Patel, S.K. Patel, A.M.Prajapati and S.A.Patel.RP-HPLC method for the estimation of Dutasteride in tablet dosage form indian J Pharm Sci. 2010 Jan-Feb; 72(1): 113 116. 3. Shivprasad S. Deshmukh, Shweta S. Havele, Vaishali V. Musale, Sunil R. Dhaneshwar.Development and validation of RP-HPLC method for simultaneous estimation of Alfuzosin hydrochloride and Dutasteride in pharmaceutical dosage form Der Pharmacia Lettre, 2010, 2(6): 342-349. 4. Sethi PD, High Performance Liquid Chromatography-Quantitative analysis of Pharmaceutical Formulations, 1 st Ed., CBS Publishers & Distributors, New Delhi, India,2001. 5. ICH, Validation of Analytical Procedures: Text and methodology (Q2(R1): Internal Conference on Harmonization, IFPMA, Geneva, 2005. 6. Sweetman SC, editor. Martindale, The Complete Drug Reference. 34 th ed. London: The pharmaceutical press; 2005. P.1549. 7. Budavari S, editor. The Merck Index. 13 th ed. Whitehouse station, NJ: Merck & Co, Inc; 2001. P.3504. 8. Q1A (R2) ICH Harmonized Tripartite Guideline. Geneva, Switzerland: 2003, Feb. 9. Q2A. ICH Harmonized Tripartite Guideline. Geneva, Switzerland: 1994, Oct. 10. Q2B. ICH Harmonized Tripartite Guideline. Geneva, Switzerland: 1996, Nov. Chapter-3 Page 130