As of 14 MARCH Set up and use of the Kestrel 4500 Applied Ballis7cs system

Similar documents
As of 4 Dec Set up and use of the Kestrel K5 Applied Ballis5cs system

How To Get Started Using Your Kestrel

nvisti Kestrel Companion Pro For Android

Kestrel LiNK Ballistics For Android and iphone - Kestrel 5700 Elite & Sportsman with LiNK

Kestrel 5700 Elite. App Quick Start Guide

USER GUIDE K es t r e l E l i t e & S p o r t s m a n Wea t h e r M e t e r s w i t h A p p l i e d B a l l i s t i c s.

Kestrel HVK Gun Loader Sofware

Hornady 4 Degree of Freedom (4 DOF) Trajectory Program

Ballistic Data Cards by Major John L. Plaster

UNITED STATES MARINE CORPS WEAPONS TRAINING BATTALION MARINE CORPS COMBAT DEVELOPMENT COMMAND QUANTICO, VIRGINIA

SPLIT HOPKINSON PRESSURE BAR OPERATIONS MANUAL 5/9/2014

USER GUIDE 1000, 2000, 2500 & 2500NV, 3000, 3500 & 3500NV, 3500DT.

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1

WELCOME TO THE REVOLUTION

Xactix XeF2 OPERATION MANUAL

ADVANCED PORTABLE LAUNCH MONITOR. ES14 User Manual

Special Rifle - Pistol Edition

Training for High Muzzle Energy (HME) zeroing on MOD Ranges

Advanced Law Enforcement Sniper Course

Shearwater GF Computer

Outbreaker Sailor Compass / Outbreaker Sailor Compass Medium Model: RA202 / RA282 User Manual TABLE OF CONTENTS

APPLICATION NOTES DELOMATIC 4, DM-4 GAS

The other thing about ranges that are tree lined on both sides like Lodi (above), Oak Ridge (below),

Besides all the normal preparation, this highlights the typical rms features

IMPACT Data Book Instructions

SAFETY SUMMARY.2 CHAPTER I - INTRODUCTION.5 CHAPTER II - OPERATING INSTRUCTIONS.12 CHAPTER III - CALCULATING OFFSET FOR SIGHT ALIGNMENT.

Temperature Controller CC24-7 ULTRA USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

An Engineering Approach to Precision Ammunition Development. Justin Pierce Design Engineer Government and International Contracts ATK Sporting Group

High Performance Electronic Components 1411 S. Roselle Rd Schaumburg, IL Fax

Pistol Targets. Page 9-5x5 Drill Target 5 shots, 5 inches, 5 yards, 5 seconds, and repeated 5 times. Perfect score is 25/25.

iregatta User Manual

AIR FLOW ANEMOMETER INSTRUCTION MANUAL

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

GolfLogix: Golf GPS. User Guide for: BlackBerry Curve. Version 1.0. Software Release , 8330, 8350i, 8800, 8820, 8830, 8900

16. Studio ScaleChem Calculations

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

RPM Test; a tale with three twists. Chapter I

GNX 20/21. Owner s Manual

WEST POINT GOLF CLUB USING THE GOLFSOFTWARE PROGRAM FOR THE DRAW AND SCORING

Name Student Activity

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

1.0 General Guide WARNING!

ClubHub. User s Guide

2016 BC PRECISION RIFLE CHAMPIONSHIP COURSE OF FIRE

What is new in CAPWAP 2014

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

Vapor Sorption Analyzer

INSTRUCTION MANUAL xbox One SPS-X3 VER 4.0

GHIN Handicap Program (GHP) Summary Instructions on How to Update Your Roster

All Sport 5000 Control Console

INTRODUCTION TO NETWORK WIND 3 MOUNTING THE UNIT 14 SELECTING THE DISPLAY MODE 5 ABBREVIATIONS AND DEFINITIONS 17

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

ISCORE INTEGRATION IOS SCORING GUIDE

VISO Manual. LARSEN & BRUSGAARD Mosevej Kirke Hyllinge, Denmark Phone: Fax:

Exercise 3. Power Versus Wind Speed EXERCISE OBJECTIVE DISCUSSION OUTLINE. Air density DISCUSSION

1)! DO NOT PROCEED BEYOND THIS MARK

CATS. User s Manual. Calibration and Training System. Targeting Validation System for the 21 st Century Long-Range Specialist

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

NKhome.com

CENTER PIVOT EVALUATION AND DESIGN

ACV-10 Automatic Control Valve

FIBA Europe Coaching Website. Manual. Practice Section

Quick Guide. SGX-CA500 Cycle Computer SGY-PM Series Power Meters

Hydro-Control V User Guide

Boyle s Law: Pressure-Volume Relationship in Gases

D OPERATION and MAINTENANCE MANUAL MILITARY ALTIMASTER MA-10 (30,000 foot COMPRESSED SCALE: FP-02093) January 3, 2008 REV 12

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

To Logon On to your tee sheet, start by opening your browser. (NOTE: Internet Explorer V. 6.0 or greater is required.)

Technical Bulletin. Seametrics Smart Sensors: Barometric Compensation (with optional DTW setting) Introduction. How Pressure is Measured

[MYLAPS INTEGRATION]

CONTROL LOGIC DESCRIPTION DOCUMENT IC-410ND

Sighting in a rifle scope

Measuring Flow with. Centre County PaSEC. QC Team July P a g e

The Bianchi Match by Gwyn Roberts 2009

Boyle s Law: Pressure-Volume Relationship in Gases. PRELAB QUESTIONS (Answer on your own notebook paper)

No-Off-Season Long Range Shooting School By Kristy Titus

WARNING! Jump Number Main Window Exit Altitude Alti-Meter Mode Deployment Altitude Speed-Meter Mode...

GyroTracer. Operating Manual. North Seeking Gyroscope (Wire line mode) Version

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

WATCH COLLECTION NG701 SERIES INSTRUCTION MANUAL

Fun with Gas Laws. Prepared by Vance O. Kennedy and Ross S. Nord, Eastern Michigan University PURPOSE

Inventory User Guide

4000 Series Pocket Weather Trackers Instruction Manual

Experiment P18: Buoyant Force (Force Sensor)

Dynamic Positioning Control Augmentation for Jack-up Vessels

Making a 2700-Yard Shot

GNX 20/21. Owner s Manual

Callaway upro Golf GPS. User Guide (v1.3) 2009 Callaway Golf Company

OPTIMA 7 - BIOGAS Calibrating the gas sensors SENSOR ADJUSTMENT. Diamond Scientific 625 Peachtree St., Cocoa, Florida /Tel:

Figure 1 Example feature overview.

LX Compass module 3 Electronic compass device User manual

Precision Long Range.22LR

UNITED STATES MARINE CORPS WEAPONS TRAINING BATTALION MARINE CORPS COMBAT DEVELOPMENT COMMAND QUANTICO, VIRGINIA

Laser Tag Pro: Battle Rifle

STATION 1: HOT WHEELIN PHYSICS 1. Define Newton s First Law. 2. Describe the motion of the untaped washer when the car hits the pencils.

New Cortex Software User Guide

Owner s Manual Humiport 10/20

Cover.qxd 1/10/05 10:30 AM Page 2. user manual. diablopaintball.com

Transcription:

As of 14 MARCH 2015 Set up and use of the Kestrel 4500 Applied Ballis7cs system

Turn on Defaults into AB mode at turn on MENU Enter WX mode and scroll to BARO and set Ref al7tude to 0 so Baro reads Sta7on Pressure for Density Al7tude adjustment Note Ba5ery level defaults to 47% if in ba5ery seang - Alkaline is set but you are using a lithium ba5ery change in System Scroll to Wind SPD and hit escape back to main menu. This ensures each 7me to go to WX mode Wind SPD is first screen up. All other Environmental serngs will be done in the AB mode Environment screen. Capture / Delete Backlight, Space, Double tap Shortcut between WX and AB mode LeD Enter Up On/Off Escape/back Right Down Go to Gun selec7on, enter, and build your gun. Turn off guns not in use Escape and enter AB mode

AB mode Main opera7ng screen Eleva7on based on Range and Environment serngs MILS or MOA based on operator units selec7on Windage based on Range and environmental serngs MILS or MOA based on operator units selec7on Tgt = Target data here it displays 25 deg DOF to a 1000m target is 8.81 mils eleva7on form zero W = Wind 1 (0.57 mils) / Wind 2 (3.18 mils) hold R or right for the 1000m target IF WINDS ARE AS ENTERED IN WIND SETTING Wind serng displays wind from 2 o'clock, Wind 1 of 4mph, Wind 2 is under wind serngs 0.57 = hold Right.57 mils on the 1000m target based on a 4mph wind coming from 2 o'clock in reference to the direc7on of fire of 25 deg.

Target inputs enter TR to change / convert yards/meters enter EsNmate to determine range to target based on target size and measured mils With Tgt is highlighted hit enter to set parameters Hit escape you will be prompted to save range to target range or forget range found using esnmate Set magnenc Azimuth to target this is for Corriolis calculanon Set up or down angle (Ideg inclinanon degrees) to Target Icos inclinanon cosine will populate automancally once you input angle Range can be adjusted using the lel and right arrows on this main screen but the range will move slowly as the system is calculanng as you adjust. If you adjust range inside the target mode it moves quickly without calculanons unnl you stop. Set target Speed and DirecNon of travel Set O clock wind is coming from. Set desired wind speed 1 and 2 that will be displayed on the main screen in AB mode

Wind inputs With Wind is highlighted hit enter to set parameters Enter Wind when highlighted and use the arrow keys to change wind data Set O clock based on where the wind is coming from. Set desired wind speed 1 and 2 that will be displayed on the main screen in AB mode

Choose Coefficient G1, G7, or custom curve Switching a G1 to G7 converts G1 to G7 IF you choose a custom curve profile it locks DC, BC, Bullet Weight, Bullet Length Gun inputs With Gun highlighted hit enter to set parameters BW = Bullet Weight BD = Bullet Diameter BL = Bullet Length ZR = Zero Range BH = Bore Height Center of barrel to center of scope ZH = Zero Height offset from zero for Sup / alt ammo ZH = Zero Offset offset from zero for Sup / alt ammo RT = Rate of Twist RTD = Rate of Twist DirecNon Us the up and down arrow to Highlight the variable you want, to change use the led and right bugon to change to the desired data Select unit for Scope/ReNcle ElevaNon and Windage scale Mil/true moa/shooter moa, clicks See following page for Truing

Truing Muzzle velocity Transonic Truing the polynomial predic7ve curve make your own custom curve Transonic threshold for this gun set up ensure you are at this range or as much as 10% below (950M in this case) trans to true properly Target Range and Drop predicted based on SeAngs Truing beyond subsonic Subsonic threshold for this gun set up ensure you are at this range and beyond to true Drop Scale Factor properly Target Range and Drop predicted based on SeAngs Adjust to Actual Drop to hit target What the bullet did and enter Cal for calibrate Adjust to Actual Drop to hit target What the bullet did and enter Cal for calibrate New Muzzle velocity based on actual bullet drop New Drop Scale Factor based on actual bullet drop Accept data and return to AB home screen and it will show the new 10.50 elevanon you hit with system is now true. Confirm data by selecnng a target at midrange and ensuring elevanon is correct Accept data and the new DSF for that range will be applied to the DSF table under View DSF

When you select update Yes the Kestrel is reading the environment real- Nme and will give real- Nme data to the ballisnc engine. To guard against Solar loading, heat or cold syncing providing bad data spin the kestrel at the end of the lanyard to expose sensors to actual air temp and then immediately turn off update. While shoonng update as environment changes. Environment inputs With Environment highlighted hit enter to set parameters When the Environment is in update No the user can manipulate variables to see affects in different condinons. This is a good tool to answer quesnons on what environmental affects will do to the shoonng solunon. Simply change the variables and go back to the AB home screen to see how new variables affecnng the shoonng solunon. Enter Environment when and use the arrow keys to change data When Spin dril is Yes it automancally calculates in Spin dril. Corriolis, and Aerodynamic jump into the elevanon and wind solunon. Turn off and these variables are not calculated in to the shoonng/ wind solunon There is no need to enter into the kestrel weather mode for environment informa7on beyond reading wind speeds. All environmental necessi7es for shoo7ng are located here under environment.

Under ballisncs the precise range data can be found to the nearest meter vice in brackets in range card. Range Card Func7on Enter Range Card when highlighted and use the led and right bugons to scroll through change the last column to the range cards available data

Ballis7c Data In ballisncs, unlike in range card you get the exact variable for the exact range vice in rang increments Enter Ballis7cs when highlighted and use the Up and Down bugons to scroll through ballis7c data for the range designated Truing data True at a range between 1001m to 10% below or 900m in this case Ensure environment is updated

Normal use Turn on Do an environmental update turn on and off to prevent heart or cold loading the device Select gun Find target at transonic or up to 10% below trans Input range to target within 1 m Shoot data Calibrate MV to true the algorithm Calibrate DSF for ranges beyond Subsonic Change DOF when shoonng over 600m Spin dril on calculates spin, corriolis, aerodynamic jump turn it off and winds are pure When you swap ba5eries you do not loose your data, but Range, LaNtude default to 457m and 38 th parallel. Once trued simply range target to within 1 m and shoot the data (Ensure to conduct environmental updates as environment changes). For extreme range shots ensure you update foe shot as well as input actual DOF and LaNtude