Winter Shut Down Procedure

Similar documents
Irrigation System Winterization and Pressurization Procedures

COMPRESSOR REPLACEMENT PROCEDURE (R-134A)

AIR GAP (AG) Low Hazard High Hazard

accidents which arise due to non-observance of these instructions and the safety information herein.

INSTALLATION OPERATION MAINTENANCE

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

INSTRUCTION MANUAL FOR UNDERWATER OPERATION

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

DESIGN DATA. Dry 105a. September 5, 2008

Putting it All Together: Making Sense of Drip Irrigation UC Master Gardener Conference August 24, 2017

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING

TECHNICAL DATA. Q = C v P S

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

INSTRUCTION MANUAL FOR UNDERWATER OPERATION

INSTRUCTION MANUAL FOR UNDERWATER OPERATION

6 GAL PORTABLE OIL FREE AIR COMPRESSOR

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

Bermad Pressure Reducing. Model: 42T

Hot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)

SC6H OIL-LESS AIR COMPRESSOR

Discharge Relief Valve Operation & Maint.

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

ACCU-PULSE Installation and Operation Instructions

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

FRAGMENTATION INSTRUCTION & OPERATION HANDBOOK

HYDRAULIC CYLINDER TEST

20 GAL OIL FREE AIR COMPRESSOR

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

SILENTAIRE TECHNOLOGY

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Types 749B and R130 Changeover Manifolds

Rhino VE CE Bulk Unloader Operator s Card

AIR COMPRESSOR INSTRUCTION MANUAL. model no

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

RAM 4021 Operation Manual

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA. Trimpac 256a. October 31, 2013

FAULT CODE TROUBLESHOOTING INDEX

RESIDENTIAL IRRIGATION WORKSHOP IRRIGATION 101 AND BEYOND FOR WEST BENCH RESIDENTS

COSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

100C Air Compressor Kit

TECHNICAL DATA. Trimpac 244a. September 16, 2013

200 PSI COMPRESSORS - MODEL NUMBERS

PC1131 Electric Air Compressor

TECHNICAL DATA. than the water inlet pressure to the concentrate

ULTRA-QUIET 4 GALLON PORTABLE AIR COMPRESSOR

TECHNICAL DATA. Q= Cv S

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA Q= C. Table 1 - Specifications

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

SILENTAIRE TECHNOLOGY

IMPORTANT SAFETY INSTRUCTIONS

START UP MANUAL MADE IN USA REV US and Foreign patents and patents pending see

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Accu-Tab Systems 1000 Series by Axiall Corporation

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

NGP-250/500 Nitrogen Generator Quick Start Guide

Pneumatic Antenna Launcher mkii

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Operating Manual. Model BAC-30RT30/BAC-30DC

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

OPERATION MANUAL NTF-15

553 Series.

NORMAL OPERATING DISPLAYS GENERAL OPERATION

Smart Water Application Technologies (SWAT) TM

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

Portable Oil Lube Air Compressors

Model PSI Compressor with 3-Gallon Air Tank 12VDC

12V AIR STATION ALL-IN-ONE

Anti-flood device Model B-1

RAM 4021-DPX Operation Manual

Cable Pressurization Buffering

WHP Operations and Methods { July William M. Smethie, Jr. Lamont Doherty Geological Observatory Palisades, New York U.S.A.

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

Transcription:

Winter Shut Down Procedure Although we live in Beautiful BC, we still experience freezing temperatures. To minimize the risk of freeze damage to your irrigation system, you ll need to winterize it. Our annual Winter Shut Down Service is recommended to protect your irrigation system. The Winter Shut Down Service involves shutting off the water flow and removing all standing water from the irrigation pipes, valves, and sprinkler heads with a suitably sized air compressor. This will prevent the damage caused by frost and by the volume expansion that occurs when water turns to ice. Our service technicians perform the Winter Shut Down Service for our clients from the last week of September through to the first week of November. In order to ensure that we get to all customers before the first cold snap, we ask that you sign up in advance for our Winter Shut Down Service. (No repairs or changes can be made to your system during the Winter Shut Down Service.) Please note: Any system that is leaking badly from the main connection will be shut down from the main valve if possible. The system cannot be winterized. Repairs will be advised and quoted immediately. ** Warning: If the irrigation point of connection is not protected by a backflow device, it is not to code. This is considered an unprotected cross connection. Contaminants from the irrigation system can backflow into the potable water. Any unprotected cross connection must be noted and reported to the owner for retrofitting, repair, and testing. ** Procedures Blowing Out the Water Lines To blow out the water lines, use a 185 CFM (Cubic Foot per Minute) air compressor with a capacity of 50 to 80 PSI. 2012 Able Irrigation Ltd. All rights reserved. 1

Safety Measures Remember to practice caution when operating any motorized equipment. Do not stand over parts while the system is being blown out. Do not exceed 80 PSI with PVC piping or 50 PSI with polyethylene piping. Do not leave manual drain valves, valve bleed cocks, or solenoids open after the winter service. Blow Out Method 1. Shut off the irrigation water supply. 2. Open the drain on the supply line. Once the water in the line is drained, close the drain. 3. With the compressor valve in the closed position, attach the air compressor to the main line via a quick coupler, hose bib, or other type of connection located downstream of the backflow device. 4. Activate a station or zone on the controller. If access to the controller is not possible, bleed a zone in the field from the first valve box location. 5. Slowly open the valve on the compressor, gradually introducing air into the irrigation system until you reach 50 PSI. 6. Blow out the line, maintaining a constant pressure of 50 PSI. Increase the air pressure if the sprinkler heads do not pop up and seal. Never exceed 80 PSI. 7. Activate each station or zone until no water can be seen exiting the heads. Generally this takes two to four minutes per zone, depending on the size of each zone. Cycle back through each zone rather than running longer than five minutes. Compressed air moving through dry pipes can cause friction, which will create heat. The heat can cause damage, so do not run compressed air through dry pipes. 2012 Able Irrigation Ltd. All rights reserved. 2

8. Shut down the air compressor, release any air pressure that may be present, and disconnect the air line. Winterizing the DCVA Backflow Device Now winterize the Double Check Valve Assembly (DCVA) backflow device. The DCVA has two shut off valves (shown with blue handles in the illustration) and four test cocks. The method to use varies depending on whether or not there is an isolation valve before the device. Use the appropriate procedure. With Isolation Valve Before the Device If there s an isolation valve, flush the device using test cocks #1 and #4. 1. Close the #2 shut off valve on the DCVA. 2. Open the #1 shut off valve. 3. Open the isolation valve. 4. Attach the air hose to the #1 test cock. 5. Open test cocks #1 and #4. 6. Apply compressed air until all water is blown out through the #4 test cock. 7. Shut off the air compressor and remove the air hose from the #1 test cock. 8. Close test cocks #1 and #4. 9. Close the isolation valve. 2012 Able Irrigation Ltd. All rights reserved. 3

With NO Isolation Valve Before the Device If there s no isolation valve, flush the device using test cocks #2 and #4. 1. Close the #1 shut off valve on the DCVA. 2. Attach the air hose to the #2 test cock. 3. Open the #2 test cock. 4. Close the #2 shut off valve. 5. Open the #4 test cock. 6. Apply compressed air until all water is blown out through the #4 test cock. 7. Shut off the air compressor and remove the air hose from the #2 test cock. 8. Close test cocks #2 and #4. Winterizing the Controller Exterior Controllers If the controller is outside, leave it plugged in with the power on. The warmth created from the transformer will keep the internal components dry. Leave the controller in the Off position so that the solenoid valves in the field are not activated. Make a note to the client about whether or not a surge protector is present. Surge protectors help prevent damage during power outages. 2012 Able Irrigation Ltd. All rights reserved. 4

Interior Controllers If the controller is mounted indoors, leave the power on and the switch set to Off. Or Remove the battery backup and unplug the transformer. This method is recommended for older models of controllers that do not have built in surge protection or non volatile memory. Winterizing the Rain Sensor The rain sensor can also be prepared for winter. If the sensor has a cup design, remove standing water by setting the cup in the tilt down position. This will drain rain water that could freeze and crack the cup. Winterizing the Pump If an irrigation pump is present, disconnect power to the pump (if applicable) and open the lower drain plug to fully drain the chamber. There may be more than one plug. Refer to manufacturers recommendations for additional steps required to properly winterize specific pumps. 2012 Able Irrigation Ltd. All rights reserved. 5

Final Step Please make notes for the client about repairs that are needed in the spring, if any. Disclaimer Able Irrigation Ltd. provides this basic information about the winter shut down procedure for information purposes only, as a courtesy to our customers. This document provides a brief overview of steps to follow when preparing to shut down your irrigation system for the winter. Each irrigation system is unique, so the steps to follow for your system could be different. The steps followed by Able Irrigation s technicians are customized for your particular system, and are more complex and in depth. Able Irrigation is not liable for the actions taken by customers or other persons who choose to follow these steps. 2012 Able Irrigation Ltd. All rights reserved. 6