The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

Similar documents
ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION MANUAL

Installation Instructions

installation instructions

Your safety and the safety of others are very important.

INSTALLATION INSTRUCTIONS

Natural Gas to L.P. Gas Conversion Kit

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

Installation Instructions For Natural Gas Conversion

Natural Gas to L.P. Gas Conversion Kit

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F29, F30, F31, F32 & F33

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F13, RXGY-F27 AND RXGY-F28

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F23, F24, F25, F26, F38, F39, F40 & F41

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

INSTALLATION INSTRUCTIONS

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation Instructions

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

/2004 US/CA

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

Installation Instructions For Propane Gas Conversion (Kit Part No ) This kit is designed for conversion to Propane Gas

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

Gas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)

INSTALLATION INSTRUCTIONS

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT

Propane Conversion Kit Instructions

USER S INFORMATION MANUAL

INSTALLATION GUIDE Gas Rangetops

SL G3. Warning

Instructions for High Altitude Conversion

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

INSTALLATION INSTRUCTIONS

Installation Instructions

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Operator: Save these instructions for future use!

Natural Gas Conversion Kit

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

G96 Series BASOTROL Dual Operator Valve

DANGER WARNING IMPORTANT

Installation Instructions

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

Parts List. Qty. Qty.

Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models

36H SERIES Combination Gas Valve

SL G3 - Fuel Conversion to Natural Gas (LP to NG) P-Kit 301

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

GAS CONVERSION KIT Installation Instructions Range/Rangetop

WARNING: FOR OUTDOOR USE ONLY

WARNING: AVERTISSEMENT. LP & HIGH ALTITUDE LP CONVERSION KIT FOR INSTALLATIONS IN the United STATES (0-10,000 Ft)

Gas Conversion Kit Pilot Ignition Heaters

INSTALLATION INSTRUCTIONS

Natural Gas Conversion Kit

Conversion instructions from natural gas to propane

Propane Conversion Kit Instruction

Installation Instructions

Propane Conversion Kit Instruction

Installation Instructions

Installation Instructions

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

VR8205S,T Direct Ignition Combination Gas Controls

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

Installation Instructions

Gas Countertop Griddle

Operator: Save these instructions for future use!

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Propane Conversion Kit Instruction

Dual Solenoid Gas Valve Installation

Operator: Save these instructions for future use!

GM-7000 Series CE Approved Gas Control Valve

Installation and Operation Instructions

BGA158 Series CE Approved Class A Shutoff Gas Valve

BGA158 Series CE Approved Class B Shutoff Gas Valve

INSTALLATION, OPERATION, SERVICE & PARTS MANUAL FOR STOCK POT RANGE MODELS VSP100, VSP200 & VSP300

G92 Series BASOTROL Automatic Pilot Gas Valve

CASUAL FIRESIDE A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR FIRE PIT FOR PROPANE AND *NATURAL GAS

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

Operator: Save these instructions for future use!

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

Operator: Save these instructions for future use!

Unipower VA Series. OEM Installation & Start Up Instructions. Variable Air Gas Burners OEM Start Up IHEA U L. Quality Designed for Proven Performance

INSTRUCTION MANUAL. Gas Salamander

JACKSON GRILLS PATIO FIRE

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

VR8305 Direct Ignition Combination Gas Control

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

INSTALLATION INSTRUCTIONS

GEN-1e CO2 Generator OVERVIEW INSTALLATION PROPANE GENERATORS ONLY NATURAL GAS GENERATORS ONLY

Installation Instructions

Gas Countertop Hot Plates

Operator: Save these instructions for future use!

For *G7 / *GC2 & GUH* / GDD* Series Furnaces & Appliances Using Honeywell Gas Valves

Operator: Save these instructions for future use!

Transcription:

ACCESSORY KIT INSTALLATION INSTRUCTIONS HIGH ALTITUDE APPLICATION CONVERSION MID-EFFICIENCY SINGLE-STAGE INDUCED COMBUSTION FURNACES MODELS: P*HU/G8T-UH/L8T-UH/FL8 UPFLOW / HORIZONTAL P*DN/G8T-DN/L8T-DN DOWNFLOW 035-14446-000 REV. A (0301) This conversion kit is to be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, an explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit. The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction. Installation must be made in accordance with American National Standard National Fuel Gas Code, ANSI Z223.1- latest edition, unless superseded by local codes. For Canadian installations, the conversion shall be carried out in accordance with the requirements of the Provincial authorities having jurisdiction and in accordance with the CAN1- B149.1 and.2 installation codes. The manufacturer accepts no responsibility for malfunctions due to improper conversions. GENERAL This instruction is intended for the conversion of new equipment only, for operation at altitudes greater than 4,500 ft. above sea level. Follow the basic unit installation instruction for all other aspects of the installation.. COMMON PARTS Description Part Number Quantity Conversion Label 035-11635-000 1 Install. Instruction. 035-14446-000 1 All units are equipped to operate up to 4,500 feet above sea level without a hgh altitude kit. Installations above 2,000 ft. must be field derated as required by the National Fuel Gas Code, ANSI Z223.1 (latest edition), or in Canada, CAN/CGA B149.1 or.2 and all other applicable local codes and utility requirements. This instruction provides the necessary information to select and install both the proper pressure switch and orifice for your specific application. Data is provided for both natural and propane (LP) gases. This high altitude pressure switch and accessory includes a special switch and other items as detailed below. Improper installation, adjustment service, or maintenance can cause injury or property damage; therefore, only a qualified installer or qualified service personnel should perform this conversion. PRESSURE SWITCH Accessory Kit Switch Part Number Pressure Setting 1PS0301 024-27669-000.35 IWG 1PS0302 024-27627-000.42 IWG 1PS0311 024-27626-000.40 IWG 1PS0312 024-27628-000.45 IWG PRESSURE SWITCH For installations below 4500 ft., refer to furnace installation instructions to properly derate applications which do not require a pressure switch change. For applications above 4,500 feet, a pressure switch change is required to provide safe and reliable operation. Table 1 indicates the correct pressure switch accessory for each unit model applied. Unitary Products Group

. Do not adjust the original pressure switch to allow operation at high altitude. Unsafe operation will result. TABLE 1: HIGH ALTITUDE PRESSURE SWITCH USAGE Input (MBH) Output (MBH) The high altitude pressure switch should be changed by following this procedure. 1. Remove the burner access door. 2. Note the location of the wires on the pressure control and then disconnect them. Remove the hose from the pressure control. 3. Remove the screws securing the pressure control and remove it from the unit. Check that the new pressure control kit is correct for your application (refer to Table 1). Install the new pressure control. 4. Replace the hose and wiring as originally connected. ORIFICE SIZE SELECTION > 4,500 To 10,000 Ft. Upflow / Horizontal & Downflow Models 40 32 1PS0301 57 46 1PS0301 80 64 1PS0301 100 80 1PS0311 115 92 1PS0311 130 104 1PS0311 160 130 1PS0301 The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion. A number of factors determine the correct orifice usage for your application. These factors include the original orifice sizing, BTU content of the gas and the altitude. For natural gas applications, contact your gas supplier for the actual BTU content (heating value) of the fuel provided at your altitude. Table 3 indicates various BTU content fuels. The standard orifice used in the furnace is shown in Table 2. Find your unit and determine the standard orifice provided. Use the BTU heating value that is nearest to your value. Read across the selected table from the standard orifice to the altitude for your application and the note the new orifice size. EXAMPLE: If your unit has a #45 orifice as standard and a heating gas value of 900 BTU/CU.FT., at an altitude of 7,000 feet a #47 orifice will provide the correct firing rate. For propane (LP) applications, Use Table 4 to select the proper high altitude orifice size. The furnace must first be converted to use propane (LP) through the use of the standard propane conversion kit accessory. After selecting the proper orifice size for your application, see Table 5 for the listing that indicates the part number for your required orifice number. The orifices may be obtained through your local Source 1 Parts Distribution Center. The high altitude orifices should be changed by the following procedure: TABLE 2: STANDARD ORIFICE USAGE Input (MBH) Output (MBH) Natural Orifice Size Propane Orifice Size Upflow/Horizontal & Downflow Models 40 32 #45 #55 57 46 #45 #56 80 64 #45 #55 100 80 #45 #55 115 92 #45 #55 120 96 #45 #56 130 105 #45 #56 160 130 #43 #54 1. Carefully remove the wires from the gas valve and note their location so they may properly replaced. Remove the four screws that hold the manifold to the manifold support bracket and slide the manifold and orifices back out of the burners. 2. Remove the main burner orifices from the manifold and discard them. 3. Install the derate main burner orifices in the manifold and tighten them. 4. Reinstall the manifold in the assembly by reversing the removal process. 2 Unitary Products Group

TABLE 3: ALTITUDE/NATURAL GAS HEATING VALUE ORIFICE SELECTION Natural Gas Recommended Orifice Orifice Heating Value Shipped Altitude (Ft. Above Sea Level) (Manifold Pressure With Unit 3.5" W.C.) 0 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000 1200 BTU/CU Ft. 45 48 49 49 50 50 50 51 51 52 52 43 45 46 47 47 47 48 48 49 49 49 1100 BTU/CU.FT. 45 47 48 48 49 49 49 50 50 51 51 43 44 45 45 45 46 47 47 48 48 49 1000 BTU/CU.FT. 45 45 46 47 47 47 48 48 49 49 50 43 43 44 44 44 45 45 46 47 47 48 900 BTU/CU.FT. 45 44 45 45 45 46 47 47 48 48 49 43 42 42 43 43 43 44 44 45 46 47 800 BTU/CU.FT. 45 43 44 44 44 45 45 46 47 47 48 43 39 40 41 41 42 42 43 43 44 44 TABLE 4: ALTITUDE/PROPANE (LP) GAS HEATING VALUE ORIFICE SELECTION Propane Gas Heating Value (Manifold Pressure 10.0 W.C.) 2516 BTU/CU FT. Propane Orifice @ Sea Level Recommended Orifice Altitude (Ft. Above Sea Level) 0 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000 54 54 54 55 55 55 55 55 56 56 56 55 55 55 55 55 56 56 56 56 56 57 56 56 56 56 57 57 57 58 59 59 60 TABLE 5: ORIFICE PART NUMBERS Burner Orifices Size # Source 1 Part Number Blank 029-20423-000 41 029-20423-041 42 029-20423-042 43 029-24243-043 44 029-20423-044 45 029-20423-045 46 029-20423-046 47 029-20423-047 48 029-20423-048 49 029-20423-049 50 029-20423-050 51 029-20423-051 52 029-20423-052 55 029-20423-055 56 029-20423-056 57 029-20423-057 58 029-20423-058 59 029-20423-059 60 029-20423-060 5. Install the high altitude conversion labels as described in the LABELS sections of this instruction on page 6. 6. Refer to the unit installation instructions to complete the installation before continuing with these procedures. TESTS AND ADJUSTMENTS The following tests must be performed at the time of conversion following completion of the installation. Make sure both gas and power supplies are shut off before proceeding. 1. Connect a manometer to the pressure tap on both the inlet and outlet side of the gas valve. Connect a power supply and a gas supply to the unit, if not already connected. 2. Turn on the gas supply and bleed air from the gas supply lines at a point as close to the inlet or the gas valve as is practical. Unitary Products Group 3

3. Turn the gas valve control knob to the ON position. Make sure the space is free of gas before proceeding. 11. With the main burners ignited, check for gas leaks, especially in the following locations: gas valve inlet and outlet connections, manifold union in the burner compartment, and main burner orifices where they thread into the manifold. Repair any leaks found and recheck. Make sure the space is free of gas before proceeding. 4. Make sure unit electrical disconnect switch is in the OFF position. 5. Set the room thermostat to call for heat. 6. Turn unit electrical disconnect switch to ON. The combustion blower should start and the hot surface igniter should start glowing. 7. After air has been purged from the gas supply line, ignition should occur. Shortly after ignition, the manifold and gas inlet pressures can be checked on the manometers. Main burner ignition may be delayed on the first ignition cycle due to air in the gas manifold. 8. Adjust manifold pressure to specifications shown in Table 6. This setting will result in an input which is properly derated for your altitude. Supply gas must be within the range shown in Table 6. If required, adjust the incoming regulator spring so that the pressure falls within the range. Do not use an open flame or any source of ignition to check for leaks. 12. Operate the furnace for 15 minutes and measure the supply and return air temperatures. Verify that the temperature rise (supply air - return air rise) is within the allowable range. See the unit data plate for the minimum/maximum allowable temperature rise. If the measured rise is in excess of the maximum shown on the data plate, a higher blower speed must be selected. See the unit wiring diagram to make this change. 13. During unit operation, the main burner appearance and igniter location should be as shown below: FIGURE 1 : PROPER BURNER FLAME APPEARANCE 14. With the main burners off, disconnect the manometers and replace the plugs. Check for gas leakage at the plugs. 15. Replace all access panels. 9. Observe several ignition cycles. All main burners must ignite without delayed ignition or burning at the orifices. If delayed ignition is observed, verify that the igniter is properly mounted (not loose or crooked on bracket, and that bracket screws are not loose). 10. If burning at the orifices, excessive yellow tipping, or excessive noise is observed during any phase of main burner operation, verify unit operation. LABELS 1. Remove label 035-11635-000 from the shipping box. Check the Normal to High Altitude. NOTE: If the unit has been converted from natural gas to propane (LP), place the new label over the existing label and fill in the appropriate information. 2. Under "Rating After Conversion", write in the following: a. Orifice size, as stamped on the orifice 4 Unitary Products Group

b. Maximum inlet pressure c. Minimum inlet pressure d. Manifold pressure for both low and high inputs e. Input ratings, same as on the rating plate f. Outlet ratings, same as on the rating plate 3. Under "Changes After Conversion", write in the following: a. Kit number, located on the outside of the box. b. Unit model c. Stamp or write in the name of the organization making conversion, address, city, state, month and year. 4. Remove label backing and affix label adjacent to the Rating Plate. 5. On propane (LP) conversions, affix the corresponding gas valve label (provided in the conversion kit) to the valve. Unitary Products Group 5

6 Unitary Products Group

Unitary Products Group 7

Subject to change without notice. Printed in U.S.A. 035-14446-000 REV. A (0301) Copyright by Unitary Products Group 2001. All rights reserved. Supersedes: 650.74-N1.1V (899) Unitary 5005 Norman Product York OK Group Drive 73069