I.CHEM.E. SYMPOSIUM SERIES NO. 97 BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES

Similar documents
MODELLING ANCILLARIES: WEIR COEFFICIENTS

AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE

Experimental Characterization and Modeling of Helium Dispersion in a ¼-Scale Two-Car Residential Garage

1. The principle of fluid pressure that is used in hydraulic brakes or lifts is that:

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

Experiment (13): Flow channel

EXPERIMENTAL STUDY ON HYDROGEN EXPLOSIONS IN A FULL-SCALE HYDROGEN FILLING STATION MODEL

SHAPA TECHNICAL PAPER 10 (Revised) SIZING OF EXPLOSION RELIEF VENTS DAVID BURN FIKE UK LTD

THE WAY THE VENTURI AND ORIFICES WORK

The water supply for a hydroelectric plant is a reservoir with a large surface area. An outlet pipe takes the water to a turbine.

Experiment Instructions. Circulating Pumps Training Panel

EXPLOSION RELIEF PROTECTION FOR INDUSTRIAL PLANT OF INTERMEDIATE STRENGTH

SUMMARY OF THE EXPERIMENTAL STUDIES OF COLD HELIUM PROPAGATION ALONG A SCALE MODEL OF THE LHC TUNNEL

3 1 PRESSURE. This is illustrated in Fig. 3 3.

PLEA th Conference, Opportunities, Limits & Needs Towards an environmentally responsible architecture Lima, Perú 7-9 November 2012

Quiz name: Chapter 13 Test Review - Fluids

CFD Based Approach for VCE Risk Assessment

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

EFFECTIVE DESIGN OF CONVERTER HOODS. 111 Ferguson Ct. Suite 103 Irving, Texas U.S.A. 400 Carlingview Dr. Toronto, ON M9W 5X9 Canada.

Deborah Houssin-Agbomson, Jean-Yves Letellier, Philippe Renault, Simon Jallais

3. A fluid is forced through a pipe of changing cross section as shown. In which section would the pressure of the fluid be a minimum?

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS

Applied Fluid Mechanics

A STUDY OF THE LOSSES AND INTERACTIONS BETWEEN ONE OR MORE BOW THRUSTERS AND A CATAMARAN HULL

OIL AND GAS INDUSTRY

THE EXTERNAL EXPLOSION CHARACTERISTICS OF VENTED DUST EXPLOSIONS.

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

Gerald D. Anderson. Education Technical Specialist

CONSIDERATION OF DENSITY VARIATIONS IN THE DESIGN OF A VENTILATION SYSTEM FOR ROAD TUNNELS

Accumulation of Hydrogen Released into an Enclosure Fitted With Passive Vents Experimental Results and Simple Models

A METHOD FOR ASSESSING THE CONSEQUENCES OF SMALL LEAKS IN ENCLOSURES

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

REAL LIFE GRAPHS M.K. HOME TUITION. Mathematics Revision Guides Level: GCSE Higher Tier

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

Tutorial. BOSfluids. Relief valve

Smoke and heat Ventilator Testing

NUMERICAL INVESTIGATION OF THE FLOW BEHAVIOUR IN A MODERN TRAFFIC TUNNEL IN CASE OF FIRE INCIDENT

1. All fluids are: A. gases B. liquids C. gases or liquids D. non-metallic E. transparent ans: C

Effect of airflow direction on human perception of draught

Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations

09 - Choosing /sizing a cylinder and valve

Study on Fire Plume in Large Spaces Using Ground Heating

9 Mixing. I Fundamental relations and definitions. Milan Jahoda revision Radim Petříček, Lukáš Valenz

AIRFLOW AROUND CONIC TENSILE MEMBRANE STRUCTURES

Static Fluids. **All simulations and videos required for this package can be found on my website, here:

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

Flow transients in multiphase pipelines

COURSE NUMBER: ME 321 Fluid Mechanics I Fluid statics. Course teacher Dr. M. Mahbubur Razzaque Professor Department of Mechanical Engineering BUET

Lecture Outline Chapter 15. Physics, 4 th Edition James S. Walker. Copyright 2010 Pearson Education, Inc.

Fluid Mechanics. Liquids and gases have the ability to flow They are called fluids There are a variety of LAWS that fluids obey

Ignition modelling Are our approaches aligned?

PRAGMATIC ASSESSMENT OF EXPLOSION RISKS TO THE CONTROL ROOM BUILDING OF A VINYL CHLORIDE PLANT

APPENDIX B HYDRAULIC DESIGN DATA FOR CULVERTS

PRESSURE SURGES IN PIPELINES

Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios

Old-Exam.Questions-Ch-14 T072 T071

SUMMARY PROBLEMS CAUSED BY BACKFLOW IN PIPE SYSTEMS.

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Yasuyuki Hirose 1. Abstract

Determination of the wind pressure distribution on the facade of the triangularly shaped high-rise building structure

An Investigation of Liquid Injection in Refrigeration Screw Compressors

AN INVESTIGATION OF LONGITUDINAL VENTILATION FOR SHORT ROAD TUNNELS WITH HIGH FIRE HRR

MODELLING OF FUME EXTRACTORS C. R.

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

Effect of Argon Gas Distribution on Fluid Flow in the Mold Using Time-Averaged k-ε Models

ANALYSIS OF HEAT TRANSFER THROUGH EXTERNAL FINS USING CFD TOOL

CHAPTER 7 : SMOKE METERS AND THEIR INSTALLATIONS

SIMULATIONS OF HYDROGEN RELEASES FROM A STORAGE TANKS: DISPERSION AND CONSEQUENCES OF IGNITION

ACCUMULATION OF HYDROGEN RELEASED INTO A VENTED ENCLOSURE - EXPERIMENTAL RESULTS

Comparison of Large-Scale Vented Deflagration Tests to CFD Simulations for Partially Congested Enclosures

Regents Exam Practice: Measurement, Kinematics, Free Fall, PJM, and UCM

Chapter 15 Fluid. Density

10.4 Buoyancy is a force

High Speed Rail Tunnel Aerodynamics: Transient pressure and loadings on fixed tunnel equipment

Fluid Statics. Henryk Kudela. 1 Distribution of Pressure in the Fluid 1. 2 Hydrostatic pressure 3. 3 The Measurement of the Pressure 4

Experiment 8: Minor Losses

Khosla's theory. After studying a lot of dam failure constructed based on Bligh s theory, Khosla came out with the following;

Chapter 15 Fluids. Copyright 2010 Pearson Education, Inc.

Tightening Evaluation of New 400A Size Metal Gasket

3. GRADUALLY-VARIED FLOW (GVF) AUTUMN 2018

AIAA Brush Seal Performance Evaluation. P. F. Crudgington Cross Manufacturing Co. Ltd. Devizes, ENGLAND

Lecture 7. More on BL wind profiles and turbulent eddy structures. In this lecture

Liquid -Vapor. Contacting columns

Write important assumptions used in derivation of Bernoulli s equation. Apart from an airplane wing, give an example based on Bernoulli s principle

1/4/18. Density. Density. Density

Operational Behaviour of Safety Valves with Constant Superimposed Backpressure

Study on the Influencing Factors of Gas Mixing Length in Nitrogen Displacement of Gas Pipeline Kun Huang 1,a Yan Xian 2,b Kunrong Shen 3,c

The tensile capacity of suction caissons in sand under rapid loading

FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN

Page 1

Assistant Lecturer Anees Kadhum AL Saadi

The Usage of Propeller Tunnels For Higher Efficiency and Lower Vibration. M. Burak Şamşul

Practical Modelling & Hazard Assessment of LPG & LNG Spills

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

Characterizers for control loops

PHYS 101 Previous Exam Problems


Transcription:

BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES M. R. Marshall* and P. L. Stewart-Darling* A simple mathematical model for the buoyancy driven ventilation of an enclosed space, using a two-pipe ventilation system, is described. Experimental data which support the predictions of this model are presented and practical means of achieving recommended ventilation levels are discussed. (Key words: ventilation, buoyancy, natural gas, confined spaces). INTRODUCTION The accidental release of a flammable gas or vapour from process plant housed in a building could result in the formation of potentially hazardous mixtures unless means of preventing such a situation developing are available. An effective measure is to provide sufficient ventilation air so that any credible accidental leakage can be dispersed safely. Normally, the ventilation air will be provided by natural ventilation and in most cases this will derive from the pressure differentials created across a building by the effect of wind. However, in some circumstances, natural ventilation will be dependent on buoyancy forces derived from the difference in densities of the atmosphere within and outside a building. Por example, at low wind speeds (i.e. below about 1ms -1 ) provided that ventilator openings are suitably positioned, the natural ventilation of a building will be provided mainly by buoyancy forces rather than wind effects. In addition, for the particular case of a below ground installation the provision of adequate natural ventilation will depend almost entirely on the effective use of available buoyancy forces. Normally the density difference that promotes air movement due to buoyancy will result from a difference in temperature between the atmospheres within and outside a building but the *British Gas Corporation, Midlands Research Station, Wharf Lane, Solihull, West Midlands B91 2JW. 7

density difference can also be caused by the release of a buoyant gas within a building. A simple mathematical model of buoyancy driven ventilation, based on a two-pipe ventilation system, has been developed in which the pressure differential to cause air movement is derived from the release of a buoyant gas within an enclosure. A design formula based on this simple model is used to determine the ventilator area requirement of underground pits and similar installations operated by British Gas. Use of this formula should ensure that the levels of ventilation achieved are adequate to disperse 3afely any credible natural gas leakages that occur in these installations. This paper presents the results of an experimental study of buoyancy driven ventilation (caused by the release of a buoyant gas) and the application of the data to the design of an effective natural ventilation system is discussed. MODEL OP BUOYANCY-DRIVEN VENTILATION A relationship has been derived between ventilator area, gas leakage rate and steady state gas concentration on the basis that the driving force for air movement is provided by the presence of a layer of buoyant gas-air mixture within an enclosure. The situation considered was that of an underground pit having a two-pipe ventilation system, the air inlet pipe terminating close to the floor of the pit and the outlet pipe being located at high level. (Figure 1). In deriving the relationship, it was assumed that gas released in the enclosure would produce a layer of gas-air mixture of uniform concentration extending downwards from the top of the enclosure to the level of the point of leakage (1). On this basis, a layer depth of 0-4d (where d is the depth of the enclosure) was taken to be representative. The flow of mixture out of the enclosure is given by (2): Q M = C d A eff (2AP//>m)* where, P =V Gh o and (D 1 / A Jff 1 / A i 2 n + 1 /Ag ut Optimum ventilation air flow is achieved when k± ^out and for this condition, A eff = A in A/2 = A out / /2 8

Substituting into equation (1) gives: QM = C d A in (Gh 0 A/>//>m)^ (2) The density difference is given "by: A/> =/>a [(1-Cg)/>a + Cg/g] i.e.a/> = Cg (fa. -/>g) (3) The mean density of the gases flowing out of the enclosure is: />m =/>& - Cg(/>a -/>g) (4) Hence, A/>/f = Cg(/a -/>g)/[/>a. - Cg (/a -/g)] which can be re-written as: V/A = c g (i - s)/[i - cgd-s)] (5) Any gas leakage is assumed to mix instantaneously and uniformly with the air in the enclosure. At steady-state condition, therefore: Cg = Qg/(QA + Qg) i.e. Q M = Q A + Qg = Qg/Cg (6) Substituting equation (5) and (6) into equation (2) and rearranging gives: Qg = C d k ln y/q.jh + 0.4d.VCg(1-s)/(1-Cg(1-s)). Cg (7) where the effective buoyant height ho = h + 0.4d. i.e. Qg = 1.208 A in Jh + 0.4d-7Cg/(1-0.4Cg). Cg (8) on substituting the appropriate numerical values for C<j,G- and s. When, in this paper, experimental data are compared to the predictions of the 'simple model', these predictions are based on equation (8). The total ventilator area required to safely disperse a given natural gas release (i.e. prevent the average gas concentration exceeding 25$ of the lower explosion limit) can be obtained by re-arranging equation (8) and substituting the appropriate value for Cg ( = 0.0125). The total ventilator area (i.e. A in + A out) is then: A s = 1200Qg/(h + 0.4d) (9)

EXPERIMENTAL In order to test the validity of the simple model of buoyancy driven ventilation, experiments using releases of natural gas were conducted in several vessels, which differed in both volume and shape. All of these were fitted with a two-pipe ventilation system as shown diagramatically in Figure 1. To simulate practical leakage scenarios, the natural gas was released into the test enclosures as a pressurised jet, via small nozzles ranging in diameter from 0.6mm to 4-Omm. The influence on steady state gas concentrations of the gas delivery pressure and the leak orientation, as well as the actual gas release rate, were investigated. The majority of the experiments were conducted with a vessel having dimensions of 1.23m x 1.54m x 0.92m deep and an internal volume of 1.7m 3. Using this enclosure, the effect on the steady state gas concentration of changes in pipe diameter and pipe height were investigated, for natural gas release rates between 8.10-5 and 3-3.10~ 3 m 3 s- 1. The influence of vessel volume and shape on the steady state gas concentration was investigated by conducting additional experiments in two other enclosures: a duct-like vessel 0.61m x 1.83m x 0.61m deep, of internal volume 0.68m 3, and a cubical enclosure of 3ide length 2.7m and an internal volume of approximately 20m 3. In practice, it is likely that cowls would be fitted bo the vent pipes to prevent ingress of water into an enclosure. Consequently, the effect of these on steady state gas concentrations was investigated. During an experiment the build up of gas concentration within the test enclosure was continuously monitored by means of a multi-stream rapid gas chromatograph. Sampling points were located specifically under the base of the inlet and outlet pipes, others being located at various positions throughout the enclosure volume. RESULTS _AND _DISCUSSION A typical curve of the build-up of gas concentration with time is shown in Figure 2. This illustrates clearly that a buoyancy driven flow has been established i.e. fresh air is sampled at the base of the inlet pipe and gas-air mixture is leaving the enclosure via the outlet pipe. The curve also indicates that the mixture accumulation within the enclosure is of essentially uniform concentration. Data from all the tests performed showed that the time taken to reach steady state conditions was inversely proportional the magnitudes of both the gas leakage rate and the available ventilator area (hence, the air ventilation rate). The build-up of gas concentration illustrated in Figure 2 is representative of experiments in which the flow is established 10

correctly. However, in some cases flow reversal occured; the effect of this on the gas concentration is described in a later section. M^SSi of Pipe Diameter All the tests to investigate the effect of pipe diameter on the gas build-up were carried out in the 1.7m 3 vessel, using an horizontal leak orientation in the middle of the vessel and a gas delivery pressure of 0-35bar. In any given test, the pipes were of the same diameter with heights of 4m and 3m for the outlet and inlet pipes respectively. Figure 3 summarises the variation of the measured steady state gas concentrations with gas leakage rate for each of the pipe diameters used. The trend observed is as expected from the predictions of the 'simple model' i.e. the larger the pipe diamter, the lower the final gas concentration for a given gas leakage rate. Effect of Pipe Height To determine the effect of both the relative and actual heights of the vent pipes, tests were carried out with inlet and outlet pipe heights of 1m and 2m and also 1m and 4m respectively, in addition to those in which the corresponding pipe heights were 3m and 4m. With a difference in vent pipe height of 1m (i.e. a height combination of 3m and 4m or 1m and 2m), the results obtained for the three diameters of pipe used were similar: for an outlet pipe height of 4m, the measured steady state gas concentrations were about 20$ - 30$ higher than predicted, whereas for an outlet pipe height of 2m the measured gas concentrations were approximately 20$ - 30$ lower than predicted by the simple model. Data for the 0.154m diameter pipes is presented in Figure 4- Tests carried out with a larger difference in the pipe heights (e.g. an inlet pipe height of 1m and an outlet pipe height of 4m) resulted in lower steady state gas concentrations than predicted. It is considered that the differences between measured and calculated gas concentrations may be due to frictional losses caused by flow along the vent pipes. This factor can be included in the mathematical model. However, in practice its effect on the calculation of the required ventilator area is not significant for the small leakage rates typical of real situations (i.e. up to about lo -4 ra 3 s -1 ). Effect of Vessel Geometry The influence of vessel geometry is included in the simple model only indirectly, through defining the depth of the layer of gas-air mixture as being equal to 0.4d. The effect on steady state gas concentrations of variations in vessel volume and shape is illustrated in Figure 5- It is clear that, for a given gas release rate, the measured steady state gas concentration decreases as the vessel volume is increased. This agrees with the model predictions but there is 11

some evidence to suggest that the shape of the enclosure also has an influence. Thus, for the 20m 3 cubical vessel the measured and predicted gas concentrations were almost identical whereas concentrations measured in the smaller, non-cubical vessels were higher than expected and, in fact, increased as the ratio of Lmax: Lmin for the vessel increased. However, this apparent effect of vessel shape could also be a consequence of the initial momentum of the gas jet release, which would become less significant as the volume of the enclosure increased. Effect of Leak Source Characteristics In deriving the simple model the gas leak source characteristics were not specified i.e. no attempt was made to include such parameters as gas delivery pressure, leak orientation or the position of the gas release within an enclosure. Consequently, the influence of these factors on steady state gas concentrations was investigated experimentally. However, the data indicates that, in practice, the influence of leak source characteristics is relatively minor. Thus, measured gas concentrations were independent of the gas supply pressure over the range investigated i.e. 0.07 to 0-35 bar (Figure 6) and, whilst the leak orientation did affect the steady state gas concentration (Figure 7). the variation was limited to a maximum of about ±15$ of the mean, decreasing to about ±10$ at higher gas leakage rates. In the 1.7m 3 vessel used for the experiments, with a vertical leak orientation (upwards or downwards) the jet momentum would tend to induce an essentially upwards flow in the enclosure and, hence, assist the outward flow of gases. However, a horizontal gas release could not and this, combined with the fact that the horizontal gas releases were always directed away from the outlet pipe, might explain the higher gas concentrations obtained with this leak orientation. In a larger volume enclosure, it is anticipated that the influence of leak orientation on gas concentration would be less. Although the effect was relatively small, the influence on steady state gas concentrations of the position of the gas release within an enclosure was in general as predicted by the simple model. That is, the higher the level of the leak (and hence the shallower the layer of gas-air mixture formed) the greater the magnitude of the steady state gas concentration achieved. m Jl Reversal During some experiments, usually with high gas release rates (greater than 1.2.10-3 m 3 s _1 ), flow reversal(s) occurred - particularly under gusty wind conditions. In some cases, a steady flow pattern was never established whilst in others a reverse flow was established and maintained. i.e. fresh air was drawn into the outlet pipe and mixture flowed out of the test vessel via the (shorter) inlet pipe. The effect of this flow reversal is to reduce the effective height of the outlet pipe and hence lead to an increase in the steady state gas concentration due to the reduced flow of ventilation air. 12

Table 1 compares some measured gas concentrations obtained under 'correct' and reversed flow conditions. TABLE 1. EFFECT OF FLOW REVERSAL ON GAS CONCENTRATION Gas Leakage Rate Measured Gas Concentration {% gas-in-air) (m 3 s -1 ) Correct Flow Reversed Flow 2.4-10"" 6.5-10- 1 * 1.2. TO" 3 2. 10-3 3-3 5-7 10.5 14.0 4-3 7-0 12.0 16.0 To overcome the problem, the use of different types of cowls was investigated. These included the standard 'chinamans hat' type, a modified version of this design which has an inner inverted cone (claimed by the manufacturers to prevent back pressure in a vent pipe) and a rotating, French designed 'Aspiromatic' cowl (which was installed only on the outlet pipe). All of the cowls were successful in preventing flow reversal and, in addition, did not affect the ventilation air flow to any significant extent. The 'Aspiromatic' cowl (installed only on the oulet pipe) was particularly effective: because this rotated freely in the wind, it tended to induce gas-air mixture up the outlet pipe, hence assisting to establish flow in the correct direction. CONCLUSIONS 1. Given the assumptions inherent in the derivation of the simple mathematical model of buoyancy driven ventilation, the model predictions and experimental data were in reasonable agreement. 2. Ventilator areas calculated using this model will provide levels of ventilation adequate to disperse 3afely gas leakages of the magnitude anticipated in governor pits and similar below ground installations. (i.e. leakages up to about 10-4 m 3 s- 1 ). 3- The use of cowls on vent pipes will normally prevent flow reversal. The most effective arrangement would appear to be a 'Chinamans hat' type of cowl on the inlet pipe and an 'Aspiromatic' cowl on the outlet pipe. 13

LIST OF SYMBOLS A ē f-f - effective area of inlet and outlet ventilators (m 2 ) A^n - area of inlet ventilators (m 2 ) ^out ~ area of outlet ventilators (m 2 ) A g - total ventilator area, A in + A Qut (m 2 ) C^ - discharge coefficient (taken as 0.61) Cg - gas concentration d - depth of enclosure (ra) G - gravitational constant (9-81) (ms -2 ) h - height of outlet pipe (m) ho - effective "buoyant height (m) Lmax - maximum dimension of enclosure (m) Lmin - minimum dimension of enclosure (m) A P - pressure differential (Nm -2 ) Q_A - ventilation air flow rate (m 3 s -1 ) Qg - gas leakage rate (m 3 s -1 ) Qjd - mixture flow rate (m 3 s -1 ) s - relative density /^a. - density of air (kg.m -3 ) /9g - density of gas (kg.m -3 ) /?m - mean density of gas-air mixture (kg.m -3 ) REFERENCES 1. Marshall, M.R., 1983, 4th International Loss Prevention Symposium, Harrogate. 2. BS5925, 1980, British Standards Institution. 14

LCHEM.E. SYMPOSIUM SERIES NO. 97 OUT IN I Jf GAS-AIR MIXTURE AIR FIG. 1. SYSTEM FOR MODEL OF BUOYANCY DRIVEN VENTILATION 15

12 r GAS OFF 10-4= SAMPLE POINT AT OUTLET = SAMPLE POINT AT INLET = SAMPLE POINT AT CENTRE X = SAMPLE POINT AT BASE 10 15 20 TIME, MINUTES 25 30 FIG. 2. REPRESENTIVE FOR CORRECT CURVE OF BUILD-UP OF GAS CONCENTRATION FLOW PATTERN 20 r 18 16 ;0-051 M D= 0-103M D = ^'ts4m 14 12 10 8 EXPERIMENTAL 6 SIMPLE MODEL 4 2 GAS LEAKAGE RATE, M 3 S _1 x10" 3 FIG. 3 EFFECT OF PIPE DIAMETER ON GAS CONCENTRATION (OUTLET PIPE AM. INLET PIPE 3M ) 16

GAS LEAKAGE RATE, M 3 S 1 x 10" FIG. A. EFFECT OF PIPE HEIGHT ON GAS CONCENTRATION (0-154 M DIAMETER PIPES ) GAS LEAKAGE RATE. M 3 S~ 1 x10" 3 FIG. 5. EFFECT OF VESSEL GEOMETRY ON GAS CONCENTRATION 17

10 r 8 - = MEASURED AT 5 PSIG = MEASURED AT 1 PSIG K = SIMPLE MODEL HORIZONTAL LEAK VERTICAL LEAK i> - 2 i. GAS LEAKAGE RATE, M 3 S" 1 x 10 FIG. 6. EFFECT OF GAS PRESSURE ON GAS CONCENTRATION HORIZONTAL LEAK POSITION VERTICAL LEAK DOWNWARDS VERTICAL LEAK UPWARDS GAS LEAKAGE RATE. M*S x 10"" FIG.7. EFFECT OF DIFFERENT LEAK ORIENTATIONS ON GAS CONCENTRATION 1R