Agilent Dimension Software for ELSD User Manual

Similar documents
Agilent Auxiliary Gas Module AGM 2. User s Guide

Agilent 490 Micro GC Natural Gas Analyzer

Agilent 1290 Infinity Pump Head Maintenance

Agilent Flowmeter ADM1000

Video Notes. LC Troubleshooting Series Retention Time Shifts

Retention Time Locking: Concepts and Applications. Application

Agilent 1100 Series Analytical and Preparative Scale Fraction Collectors. User s Guide

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Supporting information for J. Med. Chem., 1994, 37(5), , DOI: /jm00031a018

GUIDE TO ULTRA-FAST HPLC. Quick Tips for Converting Conventional Reversed-Phase HPLC Separations to Ultra-Fast Separations

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

User Manual. Agilent 1260 Infinity Analytical- and Preparative-scale Fraction Collectors

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Agilent 1290 Infinity LC System Applications requiring the Agilent Ultra-Low Dispersion Kit

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

Oracle Utilities Meter Data Management Release Utility Reference Model MDM.Manage VEE and VEE Exceptions

The instrument will process the samples one by one till all the samples have been cleaned up.

Evaluation of linear and step gradient performance and retention time precision of the Agilent 1200 Series Rapid Resolution LC

SOP: Buck Scientific BLC-20P HPLC Operation

Carrier Gases in Capillary GC

Method Development Solutions

no peaks missing peaks too small peaks increasing retention decreasing retention

User Manual. Agilent 1260 Infinity Micro-scale Fraction Collector/Spotter

Low-Pressure Retention Time Locking with the 7890A GC. Application. Authors. Abstract. Introduction HPI

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Drilling Efficiency Utilizing Coriolis Flow Technology

Agilent G3180B Two-Way Splitter Kit

Setting a New Standard in Flash Chromatography Performance

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Trace-Level Analysis of Metanephrines in Plasma by HILIC LC-MS/MS

Fast method for Ginseng Analyses using Agilent Poroshell 120 Columns Scaled from a Traditional Method

Gas Mixing System (GMS)

Experiment GC : Analysis of BTEX by GC-FID

BETTER SAMPLE CARE. Spark Holland introduces. SPH1299 UHPLC Gradient Pump

PRODUCT MANUAL. Diver Smart Interface Cable AS346

AKTA pure 25 New Owner s Intro

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

SHIMADZU LC-10/20 PUMP

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

STARLOG. Capacitive Water Depth Probe

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Quantitative Analysis of Hydrocarbons by Gas Chromatography

GCMSD-Headspace Analysis SOP

Real-Time Smoothness Measurements on Concrete Pavements During Construction

ISO INTERNATIONAL STANDARD

Autodesk Moldflow Communicator Process settings

AN-03 Rotary valves applications

BUYER S GUIDE AQUAlogger 530WTD

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

ISO INTERNATIONAL STANDARD

PicoChip. Nanospray System. Column Care & Use Manual

Agilent 440 Fraction Collector

LC-SPE. Organizer 3.0 User Manual. Innovation with Integrity. Version 001 NMR

Gas Measurement Fundamentals Certification. Curriculum

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Ultrasonic Level Transmitter

1290 Infinity II Preparative Open-Bed Fraction Collector

Pipettor. User Manual

Now it is. easy to switch. CHS TM Steroid Profiling kit and software. Brochure not for distribution in the USA and Canada

Instruction Manual No. 742, 8/98

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

QuantityWare Working Paper. NGL & LPG Measurement Standard Comparison

Gradients in ion chromatography. Optimal separation with shorter analysis time

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

SPECIFICATIONS APCEPH1

Boyle s Law: Pressure-Volume Relationship in Gases

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA

Agilent Programmable Sample Dispenser PSD 120. User s Guide

Carrier Gases in Capillary GC

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation

REASONS FOR THE DEVELOPMENT

Prep LC Training Manual

Agilent Inlet EPC Leak Test

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

A Column-Flow Independent Configuration for QuickSwap. Application. Authors. Abstract. Introduction

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

GAS SUPPLY APPLICATION GUIDE

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Technical Data Sheet MF010-O-LC

MODELLING OF FUME EXTRACTORS C. R.

CheerSpirit.com Plug-In Pack 3 Kneeling

863 MHz 870 MHz Dipole 2 dbi Antenna for RP SMA

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

Prep LC Training Manual S.V.

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

Boyle s Law: Pressure-Volume. Relationship in Gases

RayPette Plus Autoclavable Pipette. User Manual

Constant Pressure Inlet (CCN) Operator Manual

Hardware Triaxial and Consolidation Testing Systems Pressure Measurement and Control

Getting to know your Sureshotgps micro V3

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Transcription:

Agilent Dimension Software for ELSD User Manual Agilent Dimension Software for ELSD User Manual Agilent Technologies

Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws. Manual Part Number G4260-90320 Edition 06/11 Printed in Germany Agilent Technologies Hewlett-Packard-Strasse 8 76337 Waldbronn This product may be used as a component of an in vitro diagnostic system if the system is registered with the appropriate authorities and complies with the relevant regulations. Otherwise, it is intended only for general laboratory use. Warranty The material contained in this document is provided as is, and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control. Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. Restricted Rights Legend If software is for use in the performance of a U.S. Government prime contract or subcontract, Software is delivered and licensed as Commercial computer software as defined in DFAR 252.227-7014 (June 1995), or as a commercial item as defined in FAR 2.101(a) or as Restricted computer software as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Agilent Technologies standard commercial license terms, and non-dod Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data. Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. Agilent Dimension Software for ELSD User Manual

In This Book In This Book This manual contains information on the Agilent Dimension Software for ELSD. Agilent Dimension Software for ELSD User Manual 3

Contents Contents 1 Introduction 5 2 Calibration Procedure 7 Evaluating Solvent Enhancement 8 Correcting Solvent Enhancement 9 Implementing Real-Time Gas Control 11 4 Agilent Dimension Software for ELSD User Manual

Agilent Dimension Software for ELSD User Manual 1 Introduction A well-known property of aerosol-based detectors is their response dependency on mobile phase composition. For example, when using a reverse-phase gradient the response of analytes eluting at the end of the gradient will be larger than those at the beginning of the gradient. For compounds of equal concentration the response of late eluting compounds can be 2 8 x larger than those at the early part of the gradient. This enhancement in compound response across a solvent gradient is a consequence of the viscosity difference between mobile phase A and B. During a typical reverse-phase gradient, the viscosity decreases as the proportion of organic mobile phase increases. This transition of decreasing solvent viscosity affects the nebulisation process of the ELSD causing an increase in the number of droplets formed, which subsequently leads to an enhancement in the detector s response. This non-uniform response across a solvent gradient has several implications when quantifying with aerosol-based detectors: 1 A slight shift in a compound s retention time between injections will lead to poor reproducibility in area response. 2 Irreproducible gradient programs will produce poor accuracy due to variations in solvent composition. If quantifying unknown compounds (where calibration standards don t exist) using chemically dissimilar calibration standards, then this enhancement effect of the mobile phase has to be considered, otherwise large errors are observed. The Agilent 38x-ELSD has the ability to compensate for this solvent enhancement by controlling the number of particles entering the detection stage in real-time during the gradient. The detector uses an on-board timetable that can be programmed to control the detector s evaporation gas flow. Agilent Technologies 5

1 Introduction In This Book This guide outlines how to calibrate & program the Agilent 38x-ELSD, in order to overcome any solvent enhancements effects, to deliver a uniform response when running gradients. 6 Agilent Dimension Software for ELSD User Manual

Agilent Dimension Software for ELSD User Manual 2 Calibration Procedure Evaluating Solvent Enhancement 8 Correcting Solvent Enhancement 9 Implementing Real-Time Gas Control 11 In order to compensate for the solvent enhancement effect on the Agilent 38x-ELSD, a gas timetable must be developed and programmed into the detector. To achieve the appropriate gas flow timetable for the solvent gradient, the following steps must be taken: 1 Inject sample under typical LC gradient conditions. 2 Characterise ELSD gradient response for single compound under typical LC conditions. 3 Use Agilent 38x-ELSD Dimension software to formulate gas flow program. 4 Download Gas program to ELS Detector. 5 Inject sample using real-time gas control program. These procedures are described in more detail below, with real chromatographic examples. Agilent Technologies 7

2 Calibration Procedure Evaluating Solvent Enhancement Evaluating Solvent Enhancement Configure the HPLC system according to the required analytical protocol. An example of the typical hardware configuration is shown in Figure 1 on page 8. Under the required analytical conditions inject a sample or standard mixture to obtain a reference chromatogram under typical LC conditions. This provides a useful control when comparing with the data obtained under gas flow control. Figure 1 HPLC Configuration under typical operating conditions 8 Agilent Dimension Software for ELSD User Manual

Calibration Procedure 2 Correcting Solvent Enhancement Correcting Solvent Enhancement Having established a response profile for the sample mixture, the contribution of solvent enhancement must be determined by calibrating the solvent gradient using a single-compound. The single compound is injected directly into the ELSD under the same gradient conditions to achieve a response profile. The HPLC solvent must be re-configured for this test to allow direct injections to be made into the ELSD. The compound that elutes at the mid-point of the gradient should be used to characterize the solvent gradient. In order to make direct injections into the ELSD, but maintain the same dwell volume for the gradient program, the LC system must be configured as shown in Figure 2 on page 9. The HPLC column must be connected between the HPLC pump and auto-sampler, and the auto-sampler must be connected directly to the ELSD. Figure 2 Configuration of HPLC system for direct injection of a single compound It is recommended that repeat injections be made at 10 % time intervals across the gradient, such that for a 10 min run, injections every 1 min should be Agilent Dimension Software for ELSD User Manual 9

2 Calibration Procedure Correcting Solvent Enhancement made. Using these conditions, a chromatogram similar to that shown in Figure 3 on page 10 should be obtained. Figure 3 Direct injections of single component across a solvent gradient, with UV data 10 Agilent Dimension Software for ELSD User Manual

Calibration Procedure 2 Implementing Real-Time Gas Control Implementing Real-Time Gas Control The Agilent 38x-ELS Detector can store in memory a series of time-based events, within a single timetable. This timetable allows the operational settings of the ELSD to be changed in real-time during a run. The timetable can be used to program the gas flow, in order to compensate for the change in ELSD response across a solvent gradient. Alternatively, the timetable can be customized to create adjustable LED intensities across a sample injection for mixtures containing samples with wide concentration ranges. The single timetable, stored on-board the ELSD, is only customizable using the Agilent 38x-ELSD DIMENSION software, which is a standalone software application. NB: Once a timetable has been downloaded to the instrument, it cannot be removed. Therefore, if a timetable of events is no longer required, either the trigger cable should be disconnected (to prevent the timetable from being initiated again), or a blank timetable (with constant detector settings programmed) should be downloaded to the ELSD instead. This section describes how to use Dimension software to formulate a real-time gas program. Creating a real-time program In order to create or modify the on-board timetable, DIMENSION software must be installed on your PC. The DIMENSION software package allows you to create a timetable on a PC, which can subsequently be downloaded to the ELSD for later use. The ELSD can only store a single timetable in memory, so the DIMENSION software can be used to create & save multiple timetables that can be downloaded individually at a later date. For further information on how to use DIMENSION software, please refer to the DIMENSION software on-line help. Agilent Dimension Software for ELSD User Manual 11

2 Calibration Procedure Implementing Real-Time Gas Control Calculating the shape of the gas gradient From the data obtained in Figure 3 on page 10, whereby the gradient response profile was characterized with a single component, a gas gradient can be defined. Using the peak area data from the single component injections, the values must be normalized against the first injection to determine the change in signal response. These data are shown in Table 1 on page 12. Table 1 Data for single compound injection A B C D 1 Peak Retention Time (mins) Injection No. Peak Area (mv.min) Change in response from injection 1 0.29 1 4.7 1.00 1.44 2 5.1 1.09 2.54 3 6.9 1.47 3.68 4 7.9 1.68 4.77 5 9.8 2.09 5.93 6 10.8 2.30 7.07 7 13.6 2.89 8.22 8 17.4 3.70 9.38 9 19.1 4.06 10.53 10 18.6 3.96 For direct injections of single component across a solvent gradient, with UV data, see Figure 3 on page 10 1 Change in response from injection 1 (D) = Response at time x (C) / Response at injection 1 (C) e.g. at time 7.07, Change in response from injection 1 = 13.6 / 4.7 = 2.89 By calculating the gradual increase in peak height of the single component, the relative change in ELSD response across the gradient can be assessed. From 12 Agilent Dimension Software for ELSD User Manual

Calibration Procedure 2 Implementing Real-Time Gas Control the data in Table 1 on page 12, the ELSD response changes by a factor of 4 across the 10 min solvent gradient. Calculating the required gas flow from the data in Table 1 on page 12 requires an experimental trial and error procedure, but a very close estimate of the gas flow program to start with can be calculated. This calculation of gas flow value at each 1 min step across the gradient is shown in Table 2 on page 14. By calculating the change in ELSD response at each minute across the gradient normalized against the first injection a value for the necessary increase in gas can be determined. However, the effect of increasing gas flow does not have a linear relationship on the ELSD response because of the logarithmic response of the ELSD. Therefore to compensate for this non-linear relationship a correction factor must be applied. By dividing the predicted linear gas increment by the correction factor, E (i.e. 3 ), then a more realistic gas increase increment is obtained. From this logarithmic gas increment value the estimated gas flow across the gradient can be made, as highlighted in red within Table 2 on page 14. Agilent Dimension Software for ELSD User Manual 13

2 Calibration Procedure Implementing Real-Time Gas Control Table 2 Data for single compound injection A B C D 1 E F 2 G 3 Peak Retention Time (mins) Single Compound Peak Area (mv.min) Change in Response vs first inj Predicted Gas flow increment (if linear) Correction Factor due to ELSD log response Predicted Gas Increment (log resp) Estimated Gas Flow Required 0.29 4.7 1.00 1.00 3 1 1.60 1.44 5.1 1.09 0.09 3 0.03 1.63 2.54 6.9 1.47 0.47 3 0.16 1.76 3.68 7.9 1.68 0.68 3 0.23 1.83 4.77 9.8 2.09 1.09 3 0.36 1.96 5.93 10.8 2.30 1.30 3 0.43 2.03 7.07 13.6 2.89 1.89 3 0.63 2.23 8.22 17.4 3.70 2.70 3 0.90 2.50 9.38 19.1 4.06 3.06 3 1.02 2.62 10.53 18.6 3.96 2.96 3 0.99 2.59 For configuration of HPLC system for direct injection of a single compound, see Figure 2 on page 9 1 Predicted Linear Gas Flow Increment (D) = Change in Response at time x (C) Change in Response at Injection 1 (C) e.g. at time 1.44, Predicted Linear Gas Flow Increment = 1.09 1.00 = 0.09 2 Predicted Log Gas Flow Increment (F) = Predicted Linear Gas Flow Increment (D) / Correction Factor (E) e.g. at time 2.54, Predicted Log Gas Flow Increment = 0.47 / 3 = 0.16 3 Estimated Gas Flow Required (G) = Initial Gas Flow at injection 1 + Predicted Log Gas Flow Increment at time x (D) e.g. at time 4.77, Estimated Gas Flow Required = 1.60 + 0.36 = 1.96 This gas flow program is a step-wise gradient and is only a guide to the required gas flow required to achieve uniformity. The next step is to input these values into Dimension software, which will interpolate between the set values and create a smooth gas transition across the gradient. 14 Agilent Dimension Software for ELSD User Manual

Calibration Procedure 2 Implementing Real-Time Gas Control Using Dimension software to develop gas program The start and end values for the gas can be inputted into Dimension to give a smooth gas profile as shown in Figure 4 on page 15. See the Dimension on-line help for further information on using Dimension. Figure 4 Gas program developed using Dimension software. Gas program from Table 2 on page 14 Having developed the initial gas profile, the program is downloaded to the ELSD and the direct injections of the single compound are repeated to assess the effect of the gas control. Figure 4 on page 15 shows the result of using the gas flow program in Figure 4 on page 15 compared to the result obtained without gas flow control as shown in Figure 3 on page 10. Agilent Dimension Software for ELSD User Manual 15

2 Calibration Procedure Implementing Real-Time Gas Control Figure 5 Re-injection of single compound using real-time gas control program. See Figure 2 on page 9 for comparison If the initial gas flow program is insufficient to control the changing peak response during the gradient, then Dimension software can be altered accordingly (i.e. by applying a different correction factor) and the new program reloaded onto the ELSD. Once this iterative process of editing and optimising the gas program has achieved the desired uniformity for the single compound injections, then the HPLC can be re-configured back to its original state as shown in Figure 1 on page 8. The ELSD stores the gas program in its memory and it is triggered by an input signal from the auto-sampler. To implement this start signal, the ELSD remote signal cable must be connected from the I/O connector on the rear of the unit to the A/S trigger cable. 16 Agilent Dimension Software for ELSD User Manual

Calibration Procedure 2 Implementing Real-Time Gas Control Agilent Dimension Software for ELSD User Manual 17

www.agilent.com In This Book The manual describes the following: Introduction Calibration Procedure Evaluating Solvent Enhancement Correcting Solvent Enhancement Implementing Real-Time Gas Control Agilent Technologies 2011 Printed in Germany 06/11 *G4260-90320* *G4260-90320* G4260-90320 Agilent Technologies