Evaluation of the Shutdown Time of Subsea Pipeline for Oil Transportation

Similar documents
The model of thermal response of Liquefied Petroleum Gas Tanks subjected to accidental heat input

SIMULATION OF ENTRAPMENTS IN LCM PROCESSES

Experimental Determination of Temperature and Pressure Profile of Oil Film of Elliptical Journal Bearing

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

Analyzing a Malfunctioning Clarifier with COMSOL s Mixture Model

ANALYSIS OF HEAT TRANSFER THROUGH EXTERNAL FINS USING CFD TOOL

CFD AND EXPERIMENTAL STUDY OF AERODYNAMIC DEGRADATION OF ICED AIRFOILS

Stress Analysis of The West -East gas pipeline with Defects Under Thermal Load

Offshore platforms survivability to underwater explosions: part I

Load Responsive Multilayer Insulation Performance Testing

Design and Optimization of Weld Neck Flange for Pressure Vessel

WP2 Fire test for toxicity of fire effluents

Tightening Evaluation of New 400A Size Metal Gasket

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Flow and Mixing in the Liquid between Bubbles

EXPERIMENTAL STUDY ON THE HYDRODYNAMIC BEHAVIORS OF TWO CONCENTRIC CYLINDERS

Elastic-Plastic Finite Element Analysis for Zhongwei--guiyang Natural Gas Pipeline Endangered by Collapse

A COMPARATIVE STUDY OF PARAFFIN WAX

EXPERIMENTAL STUDY ON BEESWAX USING WATERJET DRILLING

Numerical simulation on down-hole cone bit seals

Next Generation Quartz Pressure Gauges

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Numerical and Experimental Investigation of the Possibility of Forming the Wake Flow of Large Ships by Using the Vortex Generators

Experimental Analysis of Inclined Narrow Plate-Fins Heat Sink under Natural Convection

Investigation of Stresses in Ring Stiffened Circular Cylinder

SPE The paper gives a brief description and the experience gained with WRIPS applied to water injection wells. The main

An Innovative Solution for Water Bottling Using PET

Irrigation &Hydraulics Department lb / ft to kg/lit.

Modeling of thin strip profile during cold rolling on roll crossing and shifting mill

FEA ANALYSIS OF PRESSURE VESSEL WITHDIFFERENT TYPE OF END CONNECTIONS

Vertical Uplift Capacity of a Group of Equally Spaced Helical Screw Anchors in Sand

DESIGN AND ANALYSIS OF DIFFERENT TYPES OF FIN CONFIGURATIONS USING ANSYS

Vibrations of table tennis racket composite wood blades: modeling and experiments

Level MEASUREMENT 1/2016

ANALYSIS OF AERODYNAMIC CHARACTERISTICS OF A SUPERCRITICAL AIRFOIL FOR LOW SPEED AIRCRAFT

Evaluation of Hydropath Clearwell Technology On Carbonate Brine Scaling Using Tube Blocking Method

Free Surface Flow Simulation with ACUSIM in the Water Industry

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS

OLGA. The Dynamic Three Phase Flow Simulator. Input. Output. Mass transfer Momentum transfer Energy transfer. 9 Conservation equations

Influence of Ambient Temperature on Performance of a Joule-Thomson Refrigerator

EFFECTS OF SIDEWALL OPENINGS ON THE WIND LOADS ON PIPE-FRAMED GREENHOUSES

Golf Ball Impact: Material Characterization and Transient Simulation

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

INCLINOMETER DEVICE FOR SHIP STABILITY EVALUATION

Huntsman Polyurethanes smart simulation software. Process optimization by simulation

MEASURING A DISCHARGE COEFFICIENT OF AN ORIFICE FOR AN UNSTEADY COMPRESSIBLE FLOW

Engineering and Design Rules for Hopper Scales

Flow in a shock tube

Effect of 180 bends on gas/liquid flows in vertical upward and downward pipes

Fitness for Service Assessment of Ageing Pressure Vessel Experiencing External Corrosion: A Case Study

Flexible Metal Hose Products

17J Third Edition, January 2008 Specification for Unbonded Flexible Pipe

Numerical Simulations of a Train of Air Bubbles Rising Through Stagnant Water

STRESS ANALYSIS OF PRESSURE VESSEL WITH DIFFERENT END CONNECTIONS

VISIMIX TURBULENT. HEAT TRANSFER PROCESS IN A SEMIBATCH REACTOR

Flexible Spools Solution at Hybrid Risers Base A. Karnikian, Total and S. Tarbadar, M. Bonnissel, S. Legeay, Technip France

Time Pressure Dispensing

Linear Compressor Discharge Manifold Design For High Thermal Efficiency

Aidin Kazemi Daliri, Sepanta Naimi*

CHAPTER 5: VACUUM TEST WITH VERTICAL DRAINS

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

Numerical Investigation of Air Bubbles Evolution and Coalescence from Submerged Orifices Based on OpenFOAM

Copyright by Turbomachinery Laboratory, Texas A&M University

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

An approach to account ESP head degradation in gassy well for ESP frequency optimization

Autodesk Moldflow Communicator Process settings

STUDY OF SLUG CONTROL TECHNIQUES IN PIPELINE SYSTEMS

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

Flow and Heat Transfer Characteristics Over a NACA0018 Aerofoil and a Test Aerofoil A Comparative Study

Study on the Influencing Factors of Gas Mixing Length in Nitrogen Displacement of Gas Pipeline Kun Huang 1,a Yan Xian 2,b Kunrong Shen 3,c

Characteristics of Decompression Tank Internally Pressurized With Water Using OpenFOAM Syamsuri 1, a

IBP2739_10 FIELD TEST OF A FLEXIBLE PIPE INTEGRITY MONITORING SYSTEM Jean-Philippe Roques 1, Benoit Balagué 1, Dominique Dion 2, Gregoire Audouin 2

Experimental Investigation on Transient Response of Two Stage Pressure Relief Valve

AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE

Aerodynamic Performance of Trains with Different Longitudinal Section Lines under Crosswind

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints

Flow transients in multiphase pipelines

Balmoral Offshore Engineering

ANALYSIS OF THE POSITIVE FORCES EXHIBITING ON THE MOORING LINE OF COMPOSITE-TYPE SEA CAGE

Purdue e-pubs. Purdue University. Stephan Lehr Technische Universitaet Dresden. Follow this and additional works at:

Structural Design and Analysis of the New Mobile Refuge Chamber

Analysis of dilatometer test in calibration chamber

DAMAGE TO STORAGE TANKS CAUSED BY THE 2011 TOHOKU EARTHQUAKE AND TSUNAMI AND PROPOSAL FOR STRUCTURAL ASSESSMENT METHOD FOR CYLINDRICAL STORAGE TANKS

CFD Analysis ofwind Turbine Airfoil at Various Angles of Attack

FINITE ELEMENT ANALYSIS OF PIPELINE GLOBAL WALKING WITH SPANNING AND LATERAL BUCKLING

Learn more at

A New Piston Gauge to Improve the Definition of High Gas Pressure and to Facilitate the Gas to Oil Transition in a Pressure Calibration Chain

Numerical Simulation for the Internal Flow Analysis of the Linear Compressor with Improved Muffler

Fluid-Structure Interaction Analysis of a Flow Control Device

ISSN: Page 410

PVP Copyright 2009 by ASME

Simulation and Experimentation on the Contact Width of New Metal Gasket for Asbestos Substitution

A New Test Setup for Testing Polyethylene Tubes under Constant and Cyclic Internal Pressures

Figure 1 Schematic of opposing air bearing concept

The Relationship between the Depth Embedded Pipe Pile and the Force of Clamping Jaw

APPLICATION OF ACOUSTIC EMISSION DETECTION TECHNOLOGY ON MULTILAYER BINDING HIGH PRESSURE VESSEL

ADVANCES IN NDT TECHNIQUES FOR FRICTION STIR WELDING JOINTS OF AA2024

Transcription:

Evaluation of the Shutdown Time of Subsea Pipeline for Oil Transportation D. Maciel 1, N. Bouchonneau *1 1 Universidade Federal de Pernambuco, Recife, Pernambuco, Brazil *nadege.bouchonneau@gmail.com Abstract: The maintenance plan or rush-to-repair of a subsea pipeline for oil transport may result in the shutdown of the line, in other words, may stop the flow of fluid. During the shutdown, the temperature of the oil tends to decrease continuously, and the heavy molecules tend to crystallize and suspend in the oil, which increase the viscosity of the oil, and even form a paraffinic compound or freeze the production line. This work was carried out in order to analyze the temperature distribution in an insulated pipeline during its restart (transient state), work (steady state) and shutdown, and estimate the time required to reach the critical temperatures of approximately 40 and 25 ºC during the shutdown. Moreover, with the results assist the procedures of maintenance and restart, and ensure that they are safe, effective and economical. Keywords: pipeline, thermal insulation, oil transport, shutdown, finite element method. 1. Introduction Once the line is frozen during the shutdown, it is necessary to use complex time-consuming procedures and expensive methods to unlock it and restart the production. Therefore, it is important to conduct experimental and computational studies to analyze and better understand the behavior of lines submitted to a shutdown of the production and the evaluation of the time required to reach critical freezing temperatures (shutdown time), in order to present a safe, effective and economic proposal for the restart of the production. In order to study the behavior of insulated structures, simulations based on the Finite Element Method (FEM) were performed with COMSOL Multiphysics software to compare numerical results with those obtained experimentally in the literature. One expects to find values consistent with the actual obtained in the subsea oil industry, and characterize insulated pipelines in service conditions. Therefore, the main objective of this work is to develop and validate a suitable numerical model, which can predict the thermomechanical behavior of pipes with multilayer insulation subjected to conditions of ultra-deep service, and thus determine the critical time of shutdown according to the operation field. 2. Experiment 2.1. Insulated pipe structure The industrial structure (1.2 m initial length) consists of a steel pipe (internal diameter of about 180 mm, thickness about 18 mm) and a 5-layer insulating coating (total thickness 61mm) which were industrially applied by side extrusion process, detailed by Berti (04). The coating is composed of several material types: solid, adhesive polymers and syntactic foam, which is composed of hollow glass microspheres embedded in a polypropylene matrix. One advantage to combine varied materials is the possibility to obtain mechanical and thermal properties as well as good long-term behavior in water required for deep-sea application, all these properties being difficult to obtain with a single material. The multilayered system and the material thicknesses are presented in Fig. 1, taken from Bouchonneau et al. (). Material Thickness (mm) Steel pipe 18,26 Epoxy powder primer 0,25 Adhesive PP 0,25 Solid PP 3 Syntactic PP 55 Solid PP 2,5 Table 1. Composition of the insulated pipe.

also contribute to discuss the validity of the numerical modelling. 2.4. Testing facilities Figure 1. Industrial 5-layer insulation system. 2.2. Material properties Thermal and mechanical properties of each constitutive material of the test section are reported, respectively, in Tables 2 and 3, adapted from Bouchonneau et al. (). Material Thermal conductivity (W/m.K) Heat Capacity (J/kg.K) Steel pipe 45 475 Fusion bonded epoxy 0,3 00 Adhesive PP 0,22 90 Solid PP 0,22 00 Syntactic PP 0,165+ -4.T 1506,6+6,26.T Steel cap APX4 19 460 PTFE (insulating end cap) 0,24 50 Table 2. Thermal properties. For the prototype testing, a high pressure vessel (1 m diameter, 2 m height, up to 00 bar) located in IFREMER Brest was used. The pressure inside the vessel is regulated and monitored using a pressure transducer mounted at the top of the pressure vessel. The water temperature inside the pressure tank (about 15 C in this study) is also regulated and monitored during the tests. A schematic view of the coated test pipe in vertical position during testing in the pressure vessel is given in Fig. 2, taken from Bouchonneau et al. (). The number of sensors for the prototype instrumentation was limited by the number of connections available on the pressure vessel flange. The values given for the PP syntactic foam were collected from experimental measurements performed at 1 bar on small samples. In addition, for the steel pipe and the polymers, values from the literature were used as input data in the simulation. Material Density (kg/m³) Elastic modulus (GPa) Poisson coefficient Expansion coefficient (ºC -1 ) Steel pipe 7850 218 0,33 1. -5 Epoxy 10 3 0,4 5,3. -5 Adhesive PP 900 1,3 0,4 1,6. -4 Solid PP 900 1,3 0,4 1,6. -4 Syntactic 1,1-0,94. 640 PP -3.T 0,32 5. -5 Steel cap 7700 211 0,33 1. -5 PTFE 20 0,4 0,46 1,3. -4 Table 3. Mechanical properties. 2.3. In service tests Experimental tests on the industrial prototype contribute to develop and complete a multiscale approach by collecting experimental data on an entire structure tested under representative service conditions of pressure and temperature. The tests Figure 2. Schematic representation of the insulated pipe section during hyperbaric tests. 2.5. Equipment The insulated pipe section was machined at both ends to adapt two metallic steel caps in Stainless steel (APX4) covered by 0 mm thick Polytetrafluoroethylene (PTFE) insulating caps in order to limit axial heat flowlosses. The metallic caps were also equipped with connectors resistant to high external pressure. Three -channel connectors were necessary to allow the electrical supply of the inner heating system (one connector) and to collect inner sensor data (two connectors). The different elements that equipped the prototype are shown on Fig. 3, taken from Bouchonneau et al. ().

Figure 3. Prototype equipment. 2.6. Instrumentation The schematic representation of the fully instrumented pipe section and the location of sensors are given in Fig. 4, taken from Bouchonneau et al. (). The insulated pipe section was instrumented with six commercial temperature sensors (Pt0) specified up to 0 C minimum (accuracy of about 0.3% at 0 C), located in both inner and outer parts along the pipe length and on the caps (Fig. 4): T i ( C): inner temperature of the steel surface in the center of the pipe (one measurement); T e ( C): outer temperature of the coating surface in the center of the pipe (one measurement); T b ( C): inner temperature of the steel surface in the center of one cap (one measurement); T 0 ( C): inner temperature of the steel surface along the pipe 0 mm distant from cap (one measurement); T 50 ( C): inner temperature of the steel surface along the pipe 50 mm distant from cap (one measurement). Figure 4. Instrumentation of the industrial prototype. Besides, the outer temperature of the water in the vessel, T water ( C), was also measured using a platinium sensor. The insulated pipe section was also instrumented with four commercial heat flux sensors located in both inner and outer parts along the pipe length and the caps: φ i (W m 2 ): inner thermal flux density on the steel surface in the center of the pipe (one measurement with soft circular fluxmeter of 5 μv m 2 W 1 sensitivity specified up to 0 C); φ e (W m 2 ): outer thermal flux density on the coating surface in the center of the pipe (three measurements with a semirigid fluxmeter of 50 μv m 2 W 1 ) sensitivity specified up to 0 C and 0 bar (one measurement with a rigid fluxmeter of 30 μv m 2 W 1 sensitivity specified up to 250 C and 150 bar); φ b (W m 2 ): inner thermal flux density on the steel surface in the center of the steel cap (one measurement with rigid rectangular fluxmeter of 36 μv m 2 W 1 sensitivity specified up to 0 C). Heat flux sensors with soft flat form were selected for the internal and external pipe surfaces to reduce errors related to the difficulties in mounting rigid flat sensors. The readings obtained from all the sensors were recorded by a data acquisition unit, which could be programmed to take recordings at appropriate time intervals throughout the duration of the test. 2.7. Testing procedures For the experimental testing, a prototype structure has been instrumented and tested successively without additional pressure (external pressure of 1 bar test A) and under 300 bar hydrostatic pressure (test B), simulating inservice conditions at about 3000 m depth, at two different conditions of inner temperature, in order to study the influence of pressure and temperature on the thermal performances of the structure. Both test sequence programs are shown in Fig. 5, taken from Bouchonneau et al. (). The test sequences have been chosen in order to be representative of service conditions (pressure then temperature). In both cases, it should be emphasized that a test lasting approximately days cannot be used to predict the long term evolution of the insulation coating systems for which water uptake and creep cannot be neglected.

Figure 5. Testing programs realized on the prototype. 3. Use of COMSOL Multiphysics The computational geometry, finite element mesh and boundary conditions of the improved model used to study the thermal insulation pipe multiple layers are presented in Fig. 6. This model follows the conditions described by Bouchonneau et al. (), which are based on following hypotheses: internal convection between the air and the inner surface of the prototype, external convection between the water and the pipeline, hydrostatic pressure of the water on external surfaces of the prototype, and internal heat flux. Besides, the model consider the presence of the connector to link the experimental sensors, located at the center of the PTFE cap and is responsible for much of the longitudinal heat loss. Depending on the test and step, different experimental conditions (temperature, pressure, etc.) are applied to the structure. Therefore, the boundary and initial conditions of the model vary depending on each experimental step, and the input data used for the model are described in Tables 4 and 5. Furthermore, the initial temperatures of 240 W models are evaluated from the result of the steady state in 1 W models. Figure 6. Geometry, mesh and boundary conditions of the improved model. Experimental Step Pressure (bar) Heat Flux (W/m²) Initial Temp. Water Temp. Coefficient of External Convection he (W/m².K) Test A/ Step 2 1 2 15,36 15,25 125 Test A/ Step 3 1 4-15,3 155 Test B/ Step 3 300 2 16,62 16,75 170 Test B/ Step 4 300 4-17,27 230 Table 4. Boundary conditions. Experimental Step Air Temp. Coefficient of Internal Convection - hi (W/m².K) Constant Temp. in the end of Connector Coefficient of Internal Convection in the Connector hi2 (W/m².K) Test A/ Step 2 30 3 15,25 0,29 Test A/ Step 3 60 3,7 15,3 0,29 Test B/ Step 3 30 3 16,75 17,6 Test B/ Step 4 60 3,7 17,27 96,7 Table 5. Complementary boundary conditions described by Bouchonneau et al. (). 4. Results 4.1. Results from the steady state of the improved model First, the stationary or operation state of the pipeline with multilayer insulation was simulated, resulting in multiple charts for each test step. Here, Fig. 7 shows the most important results, from the case of 300 bar and 240 W, the distributions of temperature, displacement, stress,

resulting from the simulations for the case of 300 bar and 240 W. 0 90 Temperature 80 70 60 50 40 30 Figure 7. Results of the steady state of the improved model (deformed scale 0:1), in the case of 300 bar e 240 W. The results of the temperature distribution in all stages of testing, shows a temperature gradient in the longitudinal direction, which indicates that there is a significant heat loss in that direction. This loss of heat is obtained mainly due to the metal cap and the connector, which have high thermal conductivity, allowing heat to pass more easily. 4.2. Results from the transient state of the improved model and comparison with the experimental Then, comparisons between the simulated and experimental temperatures of the prototype were made during the transient regime, based on the location of the temperature sensors used in the tests. These are presented in Graphs 1 and 2, resulting from the simulations for the case of 300 bar (Test B). Temperature 60 55 50 45 40 35 30 25 15 0 36000 700 8000 144000 180000 216000 2500 Tb simulação Ti simulação T0 simulação T50 simulação Te simulação Tb experimental Ti experimental T0 experimental T50 experimental Graph 1. Comparison between experimental and simulated temperatures, during the test at 300 bar and 1 W. 0 36000 700 8000 144000 180000 216000 2500 Time(s) Tb simulação Ti simulação T0 simulação T50 simulação Te simulação Tb experimento Ti experimento T0 experimento T50 experimento Te experimento Graph 2. Comparison between experimental and simulated temperatures, during the test at 300 bar and 240 W. The numerical results obtained for the improved model showed good agreement with experimental values, particularly regarding to T i and T b temperatures. Therefore, it allows to validate the thermomechanical modeling proposed in this work and the stationary state obtained in both structures. Then, shutdown simulations were performed in order to evaluate the behavior of the structure during cooling, and the hypothesis and results will be presented in paragraph 4.4. 4.3. Analysis of the heat flow loss in the connector and PTFE cap With the completion of the analysis of the improved model, it appeared interesting to evaluate the heat losses flowing through the connector and the PTFE cap. To perform this evaluation, it was necessary to integrate in line and then in surface the heat flow along the desired region of the improved model, with the help of COMSOL Multiphysics tools (see Figs. 8 and 9). Figure 8. First boundary of the heat flow loss analysis.

4.4. Evaluation of the critical shutdown time Figure 9. Second boundary of the heat flow loss analysis. The results of the improved model for the case of 240 W and 300 bar, presented in the Graphs 3 and 4, show that the heat losses flowing through the connector reach.94 W, or about 4.56% of the power supplied for heating the prototype. Moreover, considering the symmetry of the model, the heat flow losses across the prototype through connectors is actually double,.88 W representing about 9.12% of heating power. Heat loss through the connector (W) Graph 3. Result of the heat flow loss across connector in the case of 240 W and 300 bar. The heat flow loss across the connector and PTFE cap reaches.53 W, or 8.55% of the heating power of the prototype. Thus, heat lost by the connector is about 53.30%, longitudinal heat loss being even more relevant in this model. Heat loss through the connector and PTFE cap (W) 12 8 6 4 2 0 25 15 5 0 0 36000 700 8000 144000 180000 216000 2500 0 36000 700 8000 144000 180000 216000 2500 Graph 4. Result of the heat flow loss across connector and PTFE cap in the case of 240 W and 300 bar. Based on the results obtained at stationary state, further simulations were performed to evaluate the behavior of the structure during a shutdown, i.e. when the internal heat flow is suddenly turned to zero. For this study, in order to evaluate the critical time of shutdown of the insulated pipe, simulations were performed to models after completion of test B/step 4 (240 W, 300 bar). Simulations with no internal heating power were then performed so that cooling of the pipeline can be analyzed in case of an emergency stop or maintenance. The results of simulated shutdown are presented in Graph 5. These curves enable to estimate the critical time to reach the shutdown temperature of 40 ºC, when the intensification of formation of paraffinic compounds occurs in the line, and at a temperature of 25 ºC, when freezing of the line occurs. Temperature ( C) 0 90 80 70 60 50 40 30 0 18000 36000 54000 700 Tb simulação Ti simulação T0 simulação T50 simulação Te simulação Graph 5. Results of the shutdown of the improved model, in the case of 300 bar e 240 W. By analyzing the results presented in Graph 5, the critical time to reach shutdown temperatures of 40 C can be evaluated to 21532.7 s or 5 h 58 min. The critical time to reach shutdown temperatures of 25 C, corresponding to the beginning of freezing of the line is 43769.9 s or 12 h 09 min. It should be emphasized that all these values were obtained by linear interpolation of the results. 6. Conclusions In this work, a thermomechanical model of an instrumented pipe has been proposed to better

represent instrumentation and experimental conditions applied to the structure. The simulation results obtained for inner and outer temperatures show good agreement with experimental data. Based on the numerical results, it was also possible to highlight relevant axial heat losses through the end caps and metallic connector. After validating the modeling, numerical simulations were performed based on the same model to simulate shutdown conditions. Based on numerical results, it could be concluded that after about 6 h of shutdown occurring in such a line of subsea oil transport, intensification will occur in the formation of paraffinic compounds, which could complicate the process of restarting the line. After about 12 h, beginning of freezing will occur in the line, preventing traditional methods of restart, based on the injection of high-pressure fluid. Therefore, such arrangements should be made in the maintenance plans and restarting of subsea lines, to ensure that the procedure taken is safe, effective and economical. COMSOL show to be a great tool to obtain rapidly estimations of critical shutdown times in pipelines, which could thus help to make quickly safe decisions about maintenance and restarting procedures. 5. LEFEBVRE, K., SAUVANT-MOYNOT, V., CHOQUEUSE, D., CHAUCHOT, P., 06. Durabilite des materiaux syntactiques d'isolation thermique et de flottabilite: des mecanismes de degradation a la modelisation des proprietes long terme. Proceedings of the Conference: Materiaux 06, Dijon, France. 6. TORRES, C. A., TREINT, F. e et al. Asphaltenes Pipeline Cleanout: A Horizontal Challenge for Coiled Tubing. SPE/ICoTA (Coiled Tubing Conference and Exhibition), The Woodlands, Texas (05). 7. WANG, R.L. Smart Choice after the Accident. Oil and Gas Pipelines, Nº 2 (). 8. Acknowledgements The authors acknowledge the support provided by the French Research Institute for Exploitation of the Brazilian National Agency of Petroleum, the Sea IFREMER, Natural Gas and Biofuels ANP (PRH26), the Petrobras and the Pernambuco Research Agency FACEPE (Projeto APQ-0775-1.08/). 7. References 1. BERTI, E., 04. Syntactic polypropylene coating solution provides thermal insulation for Bonga risers, Offshore Magazine, 64, 2. http://www.offshoremag.com/currentissue/index. cfm?p=9&v=64&i=2. 2. BOUCHONNEAU, N., SAUVANT- MOYNOT, V., CHOQUEUSE, D., GROSJEAN, F., PONCET, E., PERREUX, D., 07. Thermal insulation material for subsea pipelines: benefits of instrumented full scale testing to predict the long term thermo-mechanical behaviour. Proceedings of the Offshore Technology Conference OTC 18679, Houston, Texas, USA. 3. BOUCHONNEAU, N., SAUVANT- MOYNOT, V., CHOQUEUSE, D., GROSJEAN, F., PONCET, E., PERREUX, D. Experimental testing and modelling of an industrial insulated pipeline for deep sea application. Journal of Petroleum Science and Engineering 73, p. 1 12 (). 4. COMSOL, COMSOL Multiphysics, Multiphysics Modeling Guide (08).