TEC 1/2 3/ /4 1 1/ /2 3 4 DN A B 125,5 125,

Similar documents
TEC 1/2 3/4 DN A B C 32,25 32,25 F Kg/cm 2 bar LBS - psi

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Art PRESSURE REDUCER

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

FULL FLOW GAS BALL VALVES: LONDON EN 331 APPROVED. GAS BALL VALVES

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

High Performance BSP Dial Up Pattern Pressure Reducing Valve

PRESSURE REDUCING VALVE EUROBRASS 143 FF

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Installation, commissioning and servicing instructions

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

PRESSURE REDUCING VALVE EUROBRASSBLU CR FF

Pre-adjustable pressure reducing valves with self-contained cartridge

Flanged direct acting pressure reducing valves with piston

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Pressure reducing valves Series DRV/DRVM - DRVN/DRVMN

OPERATING INSTRUCTIONS

CALEFFI. Inclined pressure reducing valves series 01024/17 GB. replaces 01024/14 GB

CLASS TLP Pressure Reducing Valve

553 Series.

C 10 Pressure Reducing Valve

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Pressure Reducing Valve for Steam Type 2333 A

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

DS06D,G Dial Set Pressure Regulating Valve

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Press Valves. Product information

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

1800C and 1800C-HC Series Service Regulators

ACCREDITED. Function. series 5360/

Regulator from 1800 B series

PULSAR4 Pressure regulating valve (Unloader)

1305 Series Pressure Reducing Regulators

CARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition

1805 Series Relief Valves

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

CASH VALVE TYPE KP BACK PRESSURE VALVES

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

excellence of Italian engineering Field adjustable PRESSURE RELIEF VALVES

Pre-adjustable pressure reducing valves

1200B2 Series Service Regulators. Instruction Manual

High Pressure Cylinder Valves

Pressure reducing valves

Function. Code Automatic filling units with pressure gauge connection Size 1/2 Code Automatic filling units with pressure gauge Size 1/2

WATER PRESSURE REDUCER (SBD)

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2

VB85/ Pressure regulating valve (Unloader)

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Microregulator 039 1/8-1/4

PULSAR4 Pressure regulating valve (Unloader)

ACCREDITED H series Inclined pressure reducing valve sizes DN 15 (1/2 ) and DN 20 (3/4 )

630 Series Regulators and Relief Valves

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

STAINLESS STEEL OVERFLOW VALVE TYPE 417

Pressure independent control valve (PICV) FLOWMATIC

Materials : Stainless steel ASTM A351 CF8M

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Materials : Forged carbon steel A105N

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

Bermad Pressure Reducing. Model: 42T

Type 4708 Supply Pressure Regulator

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL M2

Model: 43T. Bermad Pressure Relief Valve

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

ESPLOSO GENERALE TELAIO/CHASSIS SPARE PARTS XR Cod

FOAM TANK (1/2) DATA SHEET

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

DS05C,D,G Dial Set Pressure Regulating Valves

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

HERZ-Motorised flow controler

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

CALEFFI. Flow rate metering device. 683 series 01040/10 GB. Function

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

PV4 and PV6 Piston Valves

TECHNICAL DATA CAUTION

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

Forged stainless steel ASTM A182 F316

Dival 500 Pressure Regulators

Pilot Operated Pressure Reducing Valve

Standard Specifications

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref:

Pressure reducing valves Index

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

RELIABLE PROTECTION FOR A WIDE RANGE OF RESIDENTIAL, COMMERCIAL AND INDUSTRIAL APPLICATIONS. water pressure reducing valves

VARIABLE ORIFICE BALANCING VALVE PN 25 TECHNICAL DATA SHEET. Approved by*: Main features:

Thermocirc Installation and Maintenance Instructions

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Transcription:

143 B F F C A 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 DN 15 20 25 32 40 50 65 80 100 A 77 85 91 118 126 142 147 179 188 B 125,5 125,5 159 218 225 250 270 290 330 C 40 40 59 69,5 126 87 88 97,5 104,5 F 12 12 13 18 18 20 20 22 23,5 Kg/cm 2 bar 25 25 25 25 25 25 25 25 25 LBS - psi 363 363 363 363 363 363 363 363 363

143-1/2, 3/4, 1 12 10 9 8 13 14 15 11 1 7 6 5 2 3 4 Pos. DESCRIZIONE / DESCRIPTION Qt. MATERIALE / MATERIAL 1 Corpo / Body 1 Ottone nichelato / Nickel-plated brass CW617N 2 Sede / Seat 1 Acciaio inox AISI 303 / Stainless steel AISI 303 3 Asta / Stem 1 Ottone / Brass CW614N 4 Guarnizione piana / Flat seat washer 1 NBR 5 Otturatore / Shutter 1 Ottone / Brass CW614N 6 Tappo inferiore / Bottom plug 1 Ottone nichelato / Nickel-plated brass CW617N 7 O-Ring 1 NBR 8 Diaframma / Diaphragm 1 Ottone / Brass CW614N 9 Ghiera / Nut 1 Nylon 10 Molla / Spring 1 EN 10270-1 SM 11 Tappo / Cap 2 Nylon 12 Premimolla / Regulator 1 Ottone nichelato / Nickel-plated brass CW617N 13 Coperchio superiore / Upper plug 1 Ottone nichelato / Nickel-plated brass CW617N 14 O-Ring 1 NBR 15 O-Ring 1 NBR

143-1 1/4, 1 1/2, 2, 2 1/2, 3, 4 12 9 10 8 13 14 15 16 3 2 11 5 7 6 17 1 4 18 Pos. DESCRIZIONE / DESCRIPTION Qt. MATERIALE / MATERIAL 1 Corpo / Body 1 Ottone nichelato / Nickel-plated brass CW617N 2 Sede / Seat 1 Acciaio inox AISI 303 / Stainless steel AISI 303 3 Asta / Stem 1 Ottone / Brass CW614N 4 Guarnizione piana / Flat seat washer 1 NBR 5 Otturatore / Shutter 1 Ottone / Brass CW614N 6 Tappo inferiore / Bottom plug 1 Ottone nichelato / Nickel-plated brass CW617N 7 O-Ring 1 NBR 8 Diaframma / Diaphragm 1 Ottone / Brass CW614N 9 Ghiera / Nut 1 Nylon 10 Molla / Spring 1 EN 10270-1 SM 11 Tappo / Cap 2 Nylon 12 Premimolla / Regulator 1 Ottone nichelato / Nickel-plated brass CW617N 13 Coperchio superiore / Upper plug 1 Ottone nichelato / Nickel-plated brass CW617N 14 O-Ring 1 NBR 15 Anello ferma O-Ring / Stop ring 1 Ottone / Brass CW614N 16 O-Ring 1 NBR 17 Fermo guarnizione / Stop washer 1 Ottone / Brass CW614N 18 O-Ring / O-Ring 1 NBR

PRESSURE REDUCING VALVES EUROPRESS INSTALLATION Installation For the best use and duration of the system, it is necessary to comply with the following instructions on installation, with the national regulations and with relevant local requirements. - Place of installation has to be protected from frost and has to be easily inspectable - Install the pressure reducing valve on the private water system, immediately downstream of the water meter - It would be better to install shut-off valves upstream and downstream of the pressure reducing valve, to facilitate the maintenance operations - In order to protect pressure reducing valve from overpressure, install a check valve immediately downstream of the pressure reducing valve - The right scheme of installation is shown in Fig. 5.2 - In case of water heater downstream of the pressure reducing valve, install an expansion vessel between the valve and the water heater - Pressure reducing valve is not a safety device. It would be better to install all the necessary safety relief valves. Please, duly note the downstream pressure of the reducing valve has not to be higher than the maximum working pressure of the devices installed in the private water system, in order to avoid possible damages or malfunctions. Instruction on installation 1. Before installing the pressure reducing valve, open all the outlets to flush the system and expel any air left in piping 2. Install shut-off valves upstream and downstream to facilitate maintenance operations 3. For a right flow direction, use the arrow stamped on the body 4. ITAP pressure reducing valve can be installed in either vertical or horizontal piping. It can be installed also upside down 5. Art. 143 is equipped with a threaded connection suitable for a pressure gauge. It is possible to unscrew the plug made by 6. Nylon PA6 in order to install a pressure gauge in the size of 1/4. In such a position, the pressure gauge shows the downstream pressure of the reducing valve. The whole range of ITAP pressure reducing valves are tested and adjusted with a downstream pressure of 3 bar. It is possible to change the downstream pressure by means of the adjusting device. 7. The final adjustment of the pressure reducing valve has to be carried out with a filled private water system and with all the outlets shut-off. The upstream pressure has to be at least 1 bar higher than the adjusted pressure. Adjustment of the pressure reducing valve to a downstream pressure different from the pre-adjusted one (3 bar): - Close the downstream shut-off valve - Unscrew the nylon nut (Fig. 4.1) - Adjustment is carried out by means of a tool or a screwdriver on the upper part of the device (Fig. 4.2); turn in clockwise way to increase the downstream pressure, turn in anticlockwise way to reduce the downstream pressure - Open the outlets in the private water system, in order to check the stability of the adjusted pressure - Adjust the downstream pressure with outlets totally shut-off and with water at room temperature only - Screw the nylon nut (Fig. 4.3) FIG. 4.1 FIG. 4.2 FIG. 4.3 EUROPRESS

PRESSURE REDUCING VALVES EUROPRESS Troubleshooting Increase in pressure downstream on the pressure reducing valve with a water heater in-line This problem is due to heating of the water, caused by the water heater. The pressure downstream increases, due to water expansion, as the pressure reducing valve is correctly closed. It is necessary to install an expansion vessel between the pressure reducing valve and the water heater to absorb the pressure increase (Fig. 5.1). FIG. 5.1 The pressure reducing valve does not maintain the adjusted figure In most cases, this problem is due to the presence of impurities on the valve seat, causing blow-by and consequent increase in the downstream pressure. Install an Y-strainer upstream of the pressure reducing valve. Carry-out the maintenance of the Y-strainer. Flush the water system before installing the pressure reducing valve. Flow direction Ball valve Y strainer Pressure reducing valve Check valve Ball valve EUROPRESS Subject to Change

DECLARATION OF CONFORMITY (According to EN ISO/IEC 17050-1) The ITAP S.p.A. manufacturer of valves, fittings, manifolds and accessories for thermo-sanitary plants, with head office in via Ruca 19/21 25065 Lumezzane S.S. (BS) Italy. DECLARES Under its sole responsibility that the EUROPRESS pressure reducing valves have been built according to industry standards and conform to their technical specifications, respecting the Company Quality System complies with UNI EN ISO 9001. Lumezzane 19 November 2013 Industrial Manager. 11/2013 Rev.0