Electrochemical Sensor

Similar documents
Electrochemical Sensor

ME3-HCL Electrochemical sensor

Electrochemical Carbon Monoxide Gas Sensor (Model:ME3-CO) Manual. Version 1.2 Valid from May 1 st 2014

Manual. MEMS Combustible Gas Sensor. Zhengzhou Winsen Electronics Technology Co., Ltd. (Model No.:GM-402B) Version: 1.0. Valid from:

MEMS VOC Gas Sensor. (Model No.:GM-503A) Manual. Version: 1.0. Valid from: Zhengzhou Winsen Electronics Technology Co.

Nemoto Sensor Engineering Company Ltd

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

Nemoto Sensor Engineering Company Ltd

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

MODEL GT820 OXYGEN SENSOR

Phosgene Sensor. Sensoric COCl2 3E 1

MD61 Thermal Conductor Gas Sensor

All Sixth Sense cells for toxic gas detection are based on electrochemical principles and can be classified as amperometric fuel cells.

an ISO9001 company TECHNICAL INFORMATION FOR SK-25F Technical Information for Figaro Oxygen Sensor SK-25F

Ozone. Sensoric O3 3E 1

USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases)

Operation manual Oxygen sensor

12/07/2016 Grove Gas Sensor(O₂) Wiki

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Grove - Gas Sensor (O2)

Item Parameter Min Typical Max Unit. VCC Working Voltage V. PH Heating consumption mw. RH Heater resistance - 31±10% - Ω

Dissolved Oxygen Guide

Operating Characteristics and Handling Manual for the NAP-55A / NAP-50A Explosive/Flammable Gas Sensor NEMOTO

O3 3E 1 F Gas Sensor Module

Transmitter CS 21 Operation Manual

GENERAL INFORMATION FOR TGS SENSORS. Technical Information on Usage of TGS Sensors for Toxic and Explosive Gas Leak Detectors

75 Allen Street Lexington, MA Minute Model & Pricing Overview Guide

Instruction and Maintenance Manual

MANUAL KPS Pressure Control Valve

Technical Data Sheet MF010-O-LC

Application Note AN-107

HTD series digital differential pressure sensors

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Sensoric 4-20 ma Transmitter Board Operation Manual

Grove - Gas Sensor(MQ9)

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Instruction and Maintenance Manual

Columbus Instruments

M iniature Amplified Pressure Sensors

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

an ISO9001 company TECHNICAL INFORMATION FOR TGS5141 Technical Information for Carbon Monoxide Sensors

PC12K Flush Diaphragm Pressure Sensor with Clamp

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

OP08 - Electrochemical 3-Electrode Un-biased Toxic Sensors CONTENTS. Introduction 2. Operating Principles 2. Recommended Circuitry 4.

an ISO9001/14001 company

Amplified Middle Pressure Sensors

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

DISSOLVED OXYGEN SENSOR BT34i

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

PC10 Piezoresistive Silicon Pressure Sensor

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

SPECIFICATION FOR APPROVAL THE PIEZOELECTRIC SOUNDER

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Specifications of Oxygen Sensor Module V-8344A

Applications Note: Use of "pentane equivalent" calibration gas mixtures

Transmitter CS 21 Operation Manual

GasSense NDIR User Manual

Coriolis Mass Flow Meter

Heavy Duty Dissolved Oxygen Meter

SX150A. Features. Typical Applications. Description

OxiQuant S. Operating Instructions

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

MS52XX-C&T SMD Pressure Sensor

Oxygen Flue Gas Analyzer BA 2000

LFE OEM TCD - Thermal Conductivity Detector

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Standard Operating Procedure for H 2 S and SO 2 Converter

COSMO INSTRUMENTS CO., LTD.

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

Operating Instructions

User Manual. µ-gard MD Electrochemical Carbon Monoxide Transmitter Serial No. MD April, 2011

MS54XX Miniature SMD Pressure Sensor

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

an ISO9001 company TECHNICAL INFORMATION FOR TGS5042 Technical Information for Carbon Monoxide Sensors

Manual of SF6 Comprehensive Tester

Best Practice Guide, Servomex 2700

PERME- OX2/230 Oxygen Transmission Rate test system

LUMAZOTE T ECHNICAL BRO CHU RE

Features. Absolute Type. For Automotive. electronics. Vdc at a. Unit. Item. Data.

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

SPD Pressure Sensor Families

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

XSL-360-5E. UV LED 5 mm TECHNICAL DATA. Absolute Maximum Ratings (T a =25 C) Specifications (If=20mA, T a =25 C) Drawing

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Selecting the right pressure sensor for your application

PRELIMINARY DATASHEET

MEC OEM. User Manual. Commercial in Confidence

MS54XX Miniature SMD Pressure Sensor

ZIRCONIA OXYGEN DETECTOR SERVICE MANUAL

Self Heating Sensing Applications

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

HLM-2000-TX Gas Transmitter User Manual

AMS 6916 Board mount pressure sensor with ratiometric analog output

Transcription:

ME3-H2 Electrochemical Sensor Manual (Model:ME3-H2) Zhengzhou Winsen Electronics Technology Co., Ltd

ME3-H2 gas sensor ME3-H2 electrochemical sensor detect gas concentration by measuring current based on the electrochemical principle, which utilizes the electrochemical oxidation process of target gas on the working electrode inside the electrolytic cell, the current produced in electrochemical reaction of the target gas are in direct proportion with its concentration while following Faraday law, then concentration of the gas could be get by measuring value of current. 1.Features * Low consumption * High precision * High sensitivity * Wide linear range * Good anti-interference ability * Excellent repeatability and stability 2 Application Widely used in industrial and environmental fields 3. Technical Parameter 4. External dimension Item Parameter Detection gas H 2 Measurement Range Max detecting 0~1000ppm 2000ppm concentration Sensitivity (0.010±0.005) µa/ppm Resolution ratio Response time(t 90 ) Bias voltage Load resistance 2ppm 90S 0mV 10Ω (recommend) Repeatability Stability(/month) Output Linearity Zero drift(-20 ~40 ) <2 % output value <2 % linear 20ppm

Storage temperature Storage Humidity -20 ~50 15 % ~90 % RH Pressure range(kpa) 90-110 Anticipated using life 2 years 5.Characterization Features of Sensitivity, response and output signal Data graph of concentration linearity features V0 Change upon Variable Temperature Sensitivity upon variable temperature

6.Basic circuit 7.Anti-Interference: ME3-H 2 sensor also responds to other gases besides target gas. Below are the response characteristics of interferential gases Gas Concentration ME3-H 2 H2S 15ppm 4ppm SO2 5ppm 0ppm CO 200 30ppm NO 35 10ppm NO2 5ppm 0.5ppm CL2 10ppm 0ppm HCL 5ppm 0ppm C2H4 100ppm 85ppm

8.Application Notes: Sensor shall Avoid organic solvent, coatings, medicine, oil and high concentration gases; All ME Sensors shall not be encapsulated completely by resin materials, and shall not immerse in pure oxygen environment, otherwise, it will damage the function of sensor; All ME sensors shall not be applied in corrosive gas environment, or the sensor will be damaged; Please test the sensitivity of gas sensors in clean atmosphere; Sensors Shall be avoided to face the gas, which flow directly from front side; To avoid to bend and break of pins; Blowhole of the sensor should not be blocked and polluted, which will cause the sensitivity decrease; Excessive impact or vibration should be avoided; Do not use the sensor when the shell is damaged; It takes some time for the sensor to return to normal state After applied in high concentration gas; Do not take apart the sensor, otherwise electrolyte leakage can cause sensor damage; Working electrode and reference electrode of the sensor shall be in short circuit when stored.; To preheat over 48hs before using and soldering forbidden; Note: To keep continual product development, we reserve right to change design features without prior notice! Zhengzhou Winsen Electronics Technology Co., Ltd Add.: NO.299 Jin Suo Road, National Hi-Tech Zone, Zhengzhou, 450001 China Tel.: 0086-371-67169097 Fax:0371-60932988 E-mail:sales@winsensor.com