Long term stability tests of INO RPC prototypes

Similar documents
ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

RPC CHARACTERIZATION AND TESTING ( by S. Mathimalar, INO Student)

arxiv: v1 [physics.ins-det] 6 May 2016

The Resistive Plate Chamber detectors at the Large Hadron Collider experiments. Danube School, September 8-13, 2014 Novi Sad

Study of Mixed Gas Flow Pattern Inside RPC

Analysis of RPC Performance with Different Gas Mixture

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

HumiSys HF High Flow RH Generator

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Thermo Scientific Model 146i Principle of Operation

Assembly and Testing of RPCs in Pakistan. Hafeez Hoorani National Centre for Physics

Review of the Hall B Gas System Hardware. George Jacobs

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

arxiv: v1 [physics.ins-det] 16 Aug 2014

March Asher Operation

Pressure Automated Calibration Equipment

arxiv: v1 [hep-ex] 18 Sep 2012

Development of small, easy to build and low gas consumming timing RPCs

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Marc McMullen. Physics Detector Support Group

Constant Pressure Inlet (CCN) Operator Manual

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

GasSense NDIR User Manual

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

FPG8601 Force Balanced Piston Gauge

Columbus Instruments

Plasma Asher: March PX-500 User guide (May-30, 2017)

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.


MCQ Gas Blender 100 Series 3 Channels Gas Mixer

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Yoke Instrumentation: ILD Muon System / Tail Catcher. Valeri Saveliev IAM, RAS, Russia DESY, Germany 3 June, 2016

Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

For Multi-Parameter Meters see mvx

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Application Note AN-107

FAS-W. Features. Applications. Automatic condensation hygrometer

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

For Multi-Parameter Meters see mvx

Mass Flow Meter (MFM) for Gases

Gas Leak Measurement of TRT Barrel Module

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

ATLAS RPC QA results at INFN Lecce

VETROSON. OXY-GEN SYSTEMS (Oxygen Generating Systems) Question & Answer Brochure

Protean Instrument Corporation 231 Sam Rayburn Parkway, Lenoir City, TN TEL/FAX:

Customer Responsibilities

Mass Spec will not Autotune

Autocalibration Systems For In Situ Oxygen Analyzers

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Mass Flow Controller (MFC) for Gases

Series Environmental Chambers

Mass Flow Meter (MFM) for gases

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

BUBBLER CONTROL SYSTEM

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

All Molybdenum Hot Zone & Elements. All Insulators are made of High Alumina. Element style - 1/8 Molybdenum Wire.

Autocalibration Systems for In Situ Oxygen Analyzers

Indian Institute of Technology Kanpur Samtel Centre for Display Technologies

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Niltox Breathing Air Purifier Range

NGN Series nitrogen generator

The TOTEM Gas System

A Longterm Aging Study of the Honeycomb Drift Tubes of HERA-B Using a Circulated and Purified CF -Gas Mixture

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

Technical Data Sheet MF010-O-LC

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Mass Flow Controller (MFC) for Gases

Membrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS.

Performance of a triple-gem detector for high rate charged particle triggering

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Subsonic Wind Tunnel 300 mm

Level MEASUREMENT 1/2016

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen.

Gas density monitor With integrated transmitter Model GDM-100-TI

Instruction and Maintenance Manual

Mass Flow Controller (MFC) for Gases

LST Gas System. R. Messner May 2004 Readiness Review

FTC130 Transmitter. Operating Manual

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Transmitter CS 21 Operation Manual

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

TH-1800-T TRX-700-CNG Converter

TSE Blood Pressure Monitor Invasive series

MANUAL KPS Pressure Control Valve

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

EPP4 Pressure Regulator Basic G 1/4"

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

Best Practice Guide, Servomex 2700

Granville-Phillips Series 370 Stabil-Ion Vacuum Gauge Controller

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

DELTI. Vac. DELTI-Vac MIL. Application. Principle. Characteristic

Transcription:

Long term stability tests of INO RPC prototypes While the problem of sudden aging in the glass RPC prototypes is being investigated, a few RPCs of dimension 40 cm 30 cm were fabricated, using glass procured from Japan. The fabrication and test procedures were similar to those of the earlier prototypes. These new chambers were being operated in avalanche gas mode, in which a gas mixture of Freon (R134a) and Isobutene in the proportion 95.5:4.5 by volume. The chambers are being operated at a high voltage of 9.3KV. Since the pickup signal strength in avalanche mode is much smaller to that in streamer mode, external amplification has been provided by preamplifiers of gain 10. Rest of the electronics and data acquisition chain is again the same as that used earlier. A comprehensive monitoring system for periodically recording the RPC high voltage currents as well as the ambient parameters such as temperature, pressure and relative humidity both inside and outside the laboratory has been designed and implemented. Using this data with the RPC test data, several correlations between the ambient parameters and the RPC operating characteristics could be established. The long term stability tests were started on two chambers named J2 and J3, during September 2005. As it can be observed from the monitoring plots shown below, performance of these chambers in terms of their efficiency, chamber currents and noise rates are unchanged over the last seven months. These tests have clearly demonstrated that indeed, the quality of glass used to fabricate the RPC is the key factor for long term stability of the chamber. Currently more of these large area glass plates are being procured so that many more large area chambers using this glass could be fabricated and tested simultaneously for their long term stability.

j23 noise vs efficiency j23 noise j23 eff 100 20000 18000 90 12000 10000 85 8000 6000 80 4000 2000 75 9/30/2005 10/20/200 11/9/2005 11/29/200 12/19/200 1/8/2006 1/28/2006 2/17/2006 3/9/2006 3/29/2006 4/18/2006 5 5 5 Date time J23 noise vs current j23 noise J2 current J3 current 15000 j23 noise rate (Hz) 180 11000 9000 130 7000 80 Current (Adc - padestal) 230 13000 5000 3000 30 9/30/2005 10/20/200 11/9/2005 11/29/200 12/19/200 1/8/2006 1/28/2006 2/17/2006 3/9/2006 3/29/2006 4/18/2006 5 5 5 Date time J23 efficiency 100 j23 efficiency J2 current J3 current 180 90 130 85 80 80 75 30 9/30/2005 10/20/200 11/9/2005 11/29/200 12/19/200 1/8/2006 1/28/2006 2/17/2006 3/9/2006 3/29/2006 4/18/2006 5 5 5 Date time Figure: Long term stability monitoring plots of J2 and J3 chambers Current (Adc - padestal) 230 95 % Efficiency Noise rate (Hz) 14000 % Efficiency 95 16000

Development of 16-channel gas mixing system A sophisticated, multi-channel gas mixing and distribution system was designed and developed. It mixes four input gases viz. Argon, Freon (134A), Isobutene and SF 6 using volumetric method. The mixed gas can be supplied simultaneously into 16 individually controlled output channels. The gas flow rate in each of output channels is maintained to be identical, using flow resistors. The return gas from connected chambers is collected into a common manifold before it is finally vented out into the atmosphere. Gas flows at every stage of the system are achieved through using electrically or pneumatically operated switches or valves. The system is equipped with a host of sensors and monitoring devices and appropriate displays of various crucial operating and quality control parameters. Figure: Flow diagram of the gas system The main components and salient features of the system are: 1. Input gas purifier columns: Four (one for each input gas), in-situ rechargeable molecular sieve based columns, mounted on the input gas lines in order to absorb moister, oil traces and other contaminants from the input gases. 2. Gas mixing section: This crucial section is based on Tylan made FC-760 model Mass Flow Controllers (MFCs). Input section of these filters feature 2 micron dust filters. Flow rates of individual gases (calibrated in Standard Cubic Centimeter per Minute, SCCM) are settable from and the same are displayed on the front-panel. Small amounts of water vapour are added in the gas mixtures used for Bakelite RPCs. A provision has been made in this section for the same.

3. Moisture meter: A microprocessor based SHAW capacitive type sensor with a suitable display of PPM as well dew point, is mounted on the mixed gas line to monitor the moisture content in the mixed gas. 4. Distribution unit: The mixed gas is distributed into 16 individually controlled gas outlets in parallel. This achieved by using SS capillaries of 2m in length and 200 microns in diameter, as flow resistors. A pressure sensor is mounted on this line to indicate the inside pressure of the system. A Parker made fine particle filter is mounted on this unit in order to purify the mixed gas further, before it enters the chambers. 5. Safety bubblers: These bubblers are mounted on individual output lines in order to take care of the back pressure exerted from and to protect the RPCs from damage due to over pressurising. 6. Isolation bubblers: These bubblers serve dual purpose of preventing back diffusion of air into the RPCs as well as to indicate the flow of gas through the chambers. The silicon oil levels in the safety and isolation bubblers are so chosen as per the pressure gradient calculations of the system. 7. Exhaust manifold: Return gas from all connected chambers is collected into this manifold, and a single output is provided to vent the used gas into the atmosphere. This manifold too has a pressure sensor to indicate the system pressure with reference to the ambient room pressure. 8. Remote control and monitoring: Required flow rates of individual gases can be set or monitored through a PC interface of the system. Other important system parameters such as pressures at various stages of the unit can also be monitored using this interface.

Figure: Front view of the gas system Tracking of Cosmic ray muons using INO RPC prototypes A separate laboratory has been setup for this detector, in which the newly developed gas system was installed. RPCs for this setup were fabricated using the same materials, fabrication procedures and parameters as of those fabricated for earlier studies. 2mm thick float glass of dimension 30 cm 30 cm is used. However, chambers were made using glass from different sources and manufacturers are used, in order to study the role of glass in the aging phenomenon that we have observed with earlier chambers. An RPC of this typical design is shown below.

Figure: A typical design of the RPCs used for muon tracking A suitable rack to house 12 chambers of 1 ft 2 in area was fabricated. The rack allows easy access to any individual chamber in the stack. It also integrates a spring loaded mechanism to keep the signal pickup panels pressed uniformly against the chambers. The Cosmic ray muon telescope was set up using seven scintillator paddles. These include one narrow paddle of 2cm in width to define the telescope window such that it centres on an individual signal pickup strip as well as a couple of them to veto muons which are passing outside the strip of our interest. Cosmic ray muon trigger based on appropriate coincidence of trigger paddle signals is generated using a logic circuit. A stack of 10 RPCs were mounted in the above mentioned rack such that signal pickup strips of all the chambers were well aligned geometrically. The chambers were operated in streamer gas mode, using a mixture of Argon, Isobutene and Freon in the ratio of 30:8:62 by volume, using the gas system described above. The operating high voltage for the entire tests was kept at 8.6KV. The high voltage supply current was monitored online as a quick measure of the stability of chambers.

Figure: Muon tracking setup using RPC stack The signals picked up by the pickup strips were transmitted on twisted pair cables into patch panels, where the line impedances are transformed in order to match to that of NIM electronics. The RPC strip analog signals are fed to discriminator and latch modules. Cosmic ray telescope trigger signal is used as strobe signal to these latch modules, so that they record binary information on presence of absence of signal on the RPC strip of our interest on every trigger. Counting rates of the RPC strips of interest are measured using scalers on its logic signal. The strips logic signals are also used to record the timing information of the RPC signal with reference to the Cosmic muon trigger, using TDC modules. Strips of only one pickup panel are readout.

Figure: A stack of 10 RPCs mounted in a rack Shown in Figure below some interesting tracking events recorded using the above setup. Muons arriving at different angles could be captured simply by relocating the telescope window. This has demonstrated that indeed these prototype chambers are capable of tracking Cosmic ray muons effectively. The information recorded in these tests could also be used extract other parameters of interest, such as efficiency, noise rate and timing of individual RPCs and their long term stability. Ambient parameters such as temperature, barometric pressure and relative humidity are also being monitored on-line in order to collate and correlate dependence chamber performance values on these ambient parameters. It was also established from these studies that the chambers made with Modi, Asai Float, Saint Gobian glasses suffered from the aging problem which was observed in the previous studies. However an RPC fabricated using the glass procured from Japan is surviving the long term stability tests so far.

Figure: Some interesting tracks recorded in the detector